# Ramp Metals Confirms VMS Discovery at Rush Target

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890

Original source: https://money.tmx.com/en/quote/RAMP/news/7878137741026822/ramp-metals-confirms-vms-discovery-at-rush-target

Publisher: tmx

Original announcement: 2025-08-05T12:00:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Ramp Metals Inc.

- Ticker: RAMP

- Exchange: TSX

- Region: Saskatchewan

- Primary commodity: Copper

- Secondary commodities: Zinc, Silver, Gold, Lead, Cobalt

- Document categories: Drill results

- Extracted: 2026-09-16 19:13:54 UTC

Narrative sentiment: 0.80 · Bullish

## Minestarters Atlas summary

Ramp Metals Inc. announced the discovery of a significant copper-zinc VMS system at its Rush target in Saskatchewan, with high-grade intercepts including 1.21% Cu, 9.34% Zn, 5.59 g/t Ag over 3.53m in Rush-001 and 0.78% Cu, 1.91% Zn, 0.53% Pb, 12.71 g/t Ag over 27.00m in Rush-010. The company has identified multiple new high-priority targets through geophysics and plans further exploration, despite current fieldwork being delayed by a wildfire. These results are considered comparable to Foran Mining's McIlvenna Bay deposit.

Reasoning: Ramp Metals announced the discovery of a significant copper-zinc VMS system at its Rush target, with high-grade intercepts and successful step-out drilling. The company has identified new targets and is well-funded for further exploration, indicating strong potential, though true widths are not yet known and fieldwork is temporarily impacted by wildfires.

- Positive factor: Discovery of a new VMS system with significant copper-zinc mineralization

- Positive factor: High-grade intercepts reported across multiple holes

- Positive factor: Step-out drilling confirms extension of mineralization

- Positive factor: New high-priority targets identified through geophysics

- Positive factor: Company is well-capitalized for aggressive exploration

- Positive factor: Comparable to a significant regional deposit \(McIlvenna Bay\)

- Negative factor: True widths of intercepts not yet determined

- Negative factor: Assay results for only 10 of 20 holes reported

- Negative factor: Wildfire impacting planned fieldwork

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 1415

## Classification and evidence

No classification tags are available.

## Extracted facts

Stored fact records: 1415. Some facts used in scoring do not have a stored record.

## Drill Results (1415)

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-0)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 1.77 m
- From: 31.53 m
- To: 33.3 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:31.53-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.60

Context: 1.77

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.95
- Grade Unit: %
- Intercept: 1.77 m
- From: 31.53 m
- To: 33.3 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:31.53-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate zinc grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 6.95

Context: 1.77

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-2)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.99
- Grade Unit: g/t
- Intercept: 1.77 m
- From: 31.53 m
- To: 33.3 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:31.53-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 4.99

Context: 1.77

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-3)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1.77 m
- From: 31.53 m
- To: 33.3 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:31.53-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 1.77

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-4)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1.77 m
- From: 31.53 m
- To: 33.3 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:31.53-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.01

Context: 1.77

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-5)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 110
- Grade Unit: ppm
- Intercept: 1.77 m
- From: 31.53 m
- To: 33.3 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:31.53-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 110

Context: 1.77

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-6)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.21
- Grade Unit: %
- Intercept: 3.53 m
- From: 61.47 m
- To: 65 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:61.47-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong copper grade over a good length in a new VMS discovery.

- Positive factor: Strong copper grade for VMS deposit type

- Positive factor: Good intercept length

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 1.21

Context: 3.53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-7)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.34
- Grade Unit: %
- Intercept: 3.53 m
- From: 61.47 m
- To: 65 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:61.47-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong zinc grade over a good length in a new VMS discovery.

- Positive factor: Strong zinc grade for VMS deposit type

- Positive factor: Good intercept length

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 9.34

Context: 3.53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-8)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.59
- Grade Unit: g/t
- Intercept: 3.53 m
- From: 61.47 m
- To: 65 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:61.47-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 5.59

Context: 3.53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-9)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 3.53 m
- From: 61.47 m
- To: 65 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:61.47-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.03

Context: 3.53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-10)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 3.53 m
- From: 61.47 m
- To: 65 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:61.47-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 3.53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-11)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 161
- Grade Unit: ppm
- Intercept: 3.53 m
- From: 61.47 m
- To: 65 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:61.47-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 161

Context: 3.53

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-12)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.26
- Grade Unit: %
- Intercept: 0.5 m
- From: 63.5 m
- To: 64 m
- Intercept Depth: 63.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:63.5-64
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Exceptional copper grade over a narrow interval within a new VMS discovery.

- Positive factor: Exceptional copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 2.26

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-13)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.75
- Grade Unit: %
- Intercept: 0.5 m
- From: 63.5 m
- To: 64 m
- Intercept Depth: 63.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:63.5-64
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong zinc grade over a narrow interval within a new VMS discovery.

- Positive factor: Strong zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 9.75

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-14)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 63.5 m
- To: 64 m
- Intercept Depth: 63.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:63.5-64
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 7.70

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-15)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 63.5 m
- To: 64 m
- Intercept Depth: 63.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:63.5-64
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a narrow interval in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.05

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-16)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 63.5 m
- To: 64 m
- Intercept Depth: 63.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:63.5-64
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a narrow interval in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.01

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-17)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 181
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 63.5 m
- To: 64 m
- Intercept Depth: 63.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:63.5-64
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a narrow interval in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 181

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-18)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.19
- Grade Unit: %
- Intercept: 0.5 m
- From: 64.5 m
- To: 65 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:64.5-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Exceptional copper grade over a narrow interval within a new VMS discovery.

- Positive factor: Exceptional copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 2.19

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-19)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.64
- Grade Unit: %
- Intercept: 0.5 m
- From: 64.5 m
- To: 65 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:64.5-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate zinc grade over a narrow interval within a new VMS discovery.

- Positive factor: Moderate zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 4.64

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-20)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 64.5 m
- To: 65 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:64.5-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 13.20

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-21)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 64.5 m
- To: 65 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:64.5-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a narrow interval in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.04

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-22)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 64.5 m
- To: 65 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:64.5-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a narrow interval in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.04

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-23)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 95
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 64.5 m
- To: 65 m
- Intercept Depth: 64.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:64.5-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a narrow interval in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 95

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-24)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.68
- Grade Unit: %
- Intercept: 1.55 m
- From: 71.94 m
- To: 73.49 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:71.94-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.68

Context: 1.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-25)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.13
- Grade Unit: %
- Intercept: 1.55 m
- From: 71.94 m
- To: 73.49 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:71.94-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong zinc grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Strong zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 10.13

Context: 1.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-26)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.83
- Grade Unit: g/t
- Intercept: 1.55 m
- From: 71.94 m
- To: 73.49 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:71.94-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 3.83

Context: 1.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-27)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1.55 m
- From: 71.94 m
- To: 73.49 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:71.94-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 1.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-28)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1.55 m
- From: 71.94 m
- To: 73.49 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:71.94-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.03

Context: 1.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-29)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 80
- Grade Unit: ppm
- Intercept: 1.55 m
- From: 71.94 m
- To: 73.49 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:71.94-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 80

Context: 1.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-30)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 5 m
- From: 112 m
- To: 117 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak copper grade over a moderate length in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak copper grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 0.13

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-31)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 5 m
- From: 112 m
- To: 117 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Very low zinc grade over a moderate length in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Very low zinc grade

- Negative factor: True width not determined

Evidence · table

> 0.04

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-32)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.31
- Grade Unit: g/t
- Intercept: 5 m
- From: 112 m
- To: 117 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a moderate length as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 10.31

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-33)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 5 m
- From: 112 m
- To: 117 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a moderate length in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-34)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 5 m
- From: 112 m
- To: 117 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a moderate length in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.18

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-35)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 5 m
- From: 112 m
- To: 117 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a moderate length in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 15

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-36)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 1 m
- From: 112 m
- To: 113 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-113
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak copper grade over a narrow interval in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak copper grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 0.19

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-37)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 1 m
- From: 112 m
- To: 113 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-113
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Very low zinc grade over a narrow interval in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Very low zinc grade

- Negative factor: True width not determined

Evidence · table

> 0.04

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-38)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 27.2
- Grade Unit: g/t
- Intercept: 1 m
- From: 112 m
- To: 113 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-113
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 27.20

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-39)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 112 m
- To: 113 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-113
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a narrow interval in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-40)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.41
- Grade Unit: %
- Intercept: 1 m
- From: 112 m
- To: 113 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-113
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a narrow interval in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.41

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-41)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 1 m
- From: 112 m
- To: 113 m
- Intercept Depth: 112 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-001:112-113
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a narrow interval in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 11

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-42)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.99
- Grade Unit: %
- Intercept: 1.5 m
- From: 55 m
- To: 56.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:55-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong copper grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Strong copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.99

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-43)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.36
- Grade Unit: %
- Intercept: 1.5 m
- From: 55 m
- To: 56.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:55-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak zinc grade in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak zinc grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 0.36

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-44)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 31.77
- Grade Unit: g/t
- Intercept: 1.5 m
- From: 55 m
- To: 56.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:55-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 31.77

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-45)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.24
- Grade Unit: g/t
- Intercept: 1.5 m
- From: 55 m
- To: 56.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:55-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.24

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-46)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1.5 m
- From: 55 m
- To: 56.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:55-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.01

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-47)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 20
- Grade Unit: ppm
- Intercept: 1.5 m
- From: 55 m
- To: 56.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:55-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 20

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-48)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.44
- Grade Unit: %
- Intercept: 23.7 m
- From: 69.3 m
- To: 93 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade over a strong length in a new VMS discovery, indicating good continuity.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Strong intercept length, indicating good continuity

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.44

Context: 23.70

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-49)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.44
- Grade Unit: %
- Intercept: 23.7 m
- From: 69.3 m
- To: 93 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate zinc grade over a strong length in a new VMS discovery, indicating good continuity.

- Positive factor: Moderate zinc grade for VMS deposit type

- Positive factor: Strong intercept length, indicating good continuity

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 3.44

Context: 23.70

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-50)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.84
- Grade Unit: g/t
- Intercept: 23.7 m
- From: 69.3 m
- To: 93 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a strong length as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 2.84

Context: 23.70

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-51)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 23.7 m
- From: 69.3 m
- To: 93 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a strong length in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.01

Context: 23.70

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-52)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 23.7 m
- From: 69.3 m
- To: 93 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a strong length in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.08

Context: 23.70

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-53)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 39
- Grade Unit: ppm
- Intercept: 23.7 m
- From: 69.3 m
- To: 93 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a strong length in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 39

Context: 23.70

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-54)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.71
- Grade Unit: %
- Intercept: 2.67 m
- From: 69.3 m
- To: 71.97 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong copper grade within a new VMS discovery.

- Positive factor: Strong copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 1.71

Context: 2.67

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-55)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.43
- Grade Unit: %
- Intercept: 2.67 m
- From: 69.3 m
- To: 71.97 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong zinc grade within a new VMS discovery.

- Positive factor: Strong zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 10.43

Context: 2.67

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-56)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.13
- Grade Unit: g/t
- Intercept: 2.67 m
- From: 69.3 m
- To: 71.97 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 7.13

Context: 2.67

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-57)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 2.67 m
- From: 69.3 m
- To: 71.97 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.03

Context: 2.67

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-58)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 2.67 m
- From: 69.3 m
- To: 71.97 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.01

Context: 2.67

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-59)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 147
- Grade Unit: ppm
- Intercept: 2.67 m
- From: 69.3 m
- To: 71.97 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:69.3-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 147

Context: 2.67

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-60)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.65
- Grade Unit: %
- Intercept: 1 m
- From: 77.5 m
- To: 78.5 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:77.5-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.65

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-61)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.02
- Grade Unit: %
- Intercept: 1 m
- From: 77.5 m
- To: 78.5 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:77.5-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate zinc grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 3.02

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-62)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.3
- Grade Unit: g/t
- Intercept: 1 m
- From: 77.5 m
- To: 78.5 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:77.5-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 4.30

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-63)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 77.5 m
- To: 78.5 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:77.5-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-64)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 1 m
- From: 77.5 m
- To: 78.5 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:77.5-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.11

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-65)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 41
- Grade Unit: ppm
- Intercept: 1 m
- From: 77.5 m
- To: 78.5 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:77.5-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 41

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-66)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.48
- Grade Unit: %
- Intercept: 4 m
- From: 89 m
- To: 93 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:89-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.48

Context: 4.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-67)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.49
- Grade Unit: %
- Intercept: 4 m
- From: 89 m
- To: 93 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:89-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate zinc grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 4.49

Context: 4.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-68)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.16
- Grade Unit: g/t
- Intercept: 4 m
- From: 89 m
- To: 93 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:89-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 4.16

Context: 4.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-69)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 4 m
- From: 89 m
- To: 93 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:89-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 4.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-70)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 4 m
- From: 89 m
- To: 93 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:89-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.12

Context: 4.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-71)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 28
- Grade Unit: ppm
- Intercept: 4 m
- From: 89 m
- To: 93 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-002:89-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 28

Context: 4.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-72)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.76
- Grade Unit: %
- Intercept: 1.5 m
- From: 64 m
- To: 65.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.76

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-73)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.42
- Grade Unit: %
- Intercept: 1.5 m
- From: 64 m
- To: 65.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate zinc grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 5.42

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-74)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.47
- Grade Unit: g/t
- Intercept: 1.5 m
- From: 64 m
- To: 65.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 4.47

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-75)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 1.5 m
- From: 64 m
- To: 65.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.04

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-76)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1.5 m
- From: 64 m
- To: 65.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-77)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 84
- Grade Unit: ppm
- Intercept: 1.5 m
- From: 64 m
- To: 65.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 84

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-78)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.31
- Grade Unit: %
- Intercept: 0.81 m
- From: 64.69 m
- To: 65.5 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64.69-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong copper grade over a narrow interval within a new VMS discovery.

- Positive factor: Strong copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 1.31

Context: 0.81

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-79)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.61
- Grade Unit: %
- Intercept: 0.81 m
- From: 64.69 m
- To: 65.5 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64.69-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong zinc grade over a narrow interval within a new VMS discovery.

- Positive factor: Strong zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 9.61

Context: 0.81

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-80)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.77
- Grade Unit: g/t
- Intercept: 0.81 m
- From: 64.69 m
- To: 65.5 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64.69-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 7.77

Context: 0.81

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-81)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: g/t
- Intercept: 0.81 m
- From: 64.69 m
- To: 65.5 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64.69-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a narrow interval in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.07

Context: 0.81

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-82)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.81 m
- From: 64.69 m
- To: 65.5 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64.69-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a narrow interval in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.01

Context: 0.81

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-83)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 143
- Grade Unit: ppm
- Intercept: 0.81 m
- From: 64.69 m
- To: 65.5 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:64.69-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a narrow interval in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 143

Context: 0.81

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-84)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.38
- Grade Unit: %
- Intercept: 5.74 m
- From: 87.76 m
- To: 93.5 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:87.76-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade over a good length in a new VMS discovery.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Good intercept length

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.38

Context: 5.74

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-85)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.75
- Grade Unit: %
- Intercept: 5.74 m
- From: 87.76 m
- To: 93.5 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:87.76-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak zinc grade over a good length in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak zinc grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 1.75

Context: 5.74

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-86)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.45
- Grade Unit: g/t
- Intercept: 5.74 m
- From: 87.76 m
- To: 93.5 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:87.76-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a good length as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 3.45

Context: 5.74

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-87)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 5.74 m
- From: 87.76 m
- To: 93.5 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:87.76-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a good length in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.01

Context: 5.74

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-88)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 5.74 m
- From: 87.76 m
- To: 93.5 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:87.76-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a good length in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.10

Context: 5.74

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-89)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 30
- Grade Unit: ppm
- Intercept: 5.74 m
- From: 87.76 m
- To: 93.5 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:87.76-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a good length in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 30

Context: 5.74

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-90)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.9
- Grade Unit: %
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong copper grade over a narrow interval within a new VMS discovery.

- Positive factor: Strong copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.90

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-91)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.84
- Grade Unit: %
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak zinc grade over a narrow interval in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak zinc grade for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 1.84

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-92)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 8.60

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-93)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a narrow interval in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.04

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-94)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a narrow interval in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.16

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-95)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 23
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a narrow interval in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 23

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-96)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 6 m
- From: 100 m
- To: 106 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak copper grade over a good length in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak copper grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 0.18

Context: 6.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-97)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.21
- Grade Unit: %
- Intercept: 6 m
- From: 100 m
- To: 106 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak zinc grade over a good length in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak zinc grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 1.21

Context: 6.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-98)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 14.55
- Grade Unit: g/t
- Intercept: 6 m
- From: 100 m
- To: 106 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a good length as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 14.55

Context: 6.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-99)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 6 m
- From: 100 m
- To: 106 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a good length in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 6.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-100)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.82
- Grade Unit: %
- Intercept: 6 m
- From: 100 m
- To: 106 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a good length in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.82

Context: 6.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-101)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16
- Grade Unit: ppm
- Intercept: 6 m
- From: 100 m
- To: 106 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a good length in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 16

Context: 6.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-102)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 1 m
- From: 100 m
- To: 101 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak copper grade over a narrow interval in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak copper grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 0.20

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-103)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.9
- Grade Unit: %
- Intercept: 1 m
- From: 100 m
- To: 101 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate zinc grade over a narrow interval in a new VMS discovery.

- Positive factor: Moderate zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 6.90

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-104)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.4
- Grade Unit: g/t
- Intercept: 1 m
- From: 100 m
- To: 101 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 9.40

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-105)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 100 m
- To: 101 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a narrow interval in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-106)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.79
- Grade Unit: %
- Intercept: 1 m
- From: 100 m
- To: 101 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a narrow interval in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.79

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-107)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 53
- Grade Unit: ppm
- Intercept: 1 m
- From: 100 m
- To: 101 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-003:100-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a narrow interval in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 53

Context: 1.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-108)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.35
- Grade Unit: %
- Intercept: 5.5 m
- From: 65.5 m
- To: 71 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:65.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade over a good length in a new VMS discovery.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Good intercept length

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.35

Context: 5.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-109)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 5.5 m
- From: 65.5 m
- To: 71 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:65.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak zinc grade over a good length in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak zinc grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 0.29

Context: 5.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-110)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.72
- Grade Unit: g/t
- Intercept: 5.5 m
- From: 65.5 m
- To: 71 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:65.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a good length as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 2.72

Context: 5.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-111)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 5.5 m
- From: 65.5 m
- To: 71 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:65.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a good length in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 5.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-112)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 5.5 m
- From: 65.5 m
- To: 71 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:65.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a good length in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.04

Context: 5.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-113)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 5.5 m
- From: 65.5 m
- To: 71 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:65.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a good length in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 15

Context: 5.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-114)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.35
- Grade Unit: %
- Intercept: 0.5 m
- From: 67 m
- To: 67.5 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:67-67.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong copper grade over a narrow interval within a new VMS discovery.

- Positive factor: Strong copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 1.35

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-115)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 67 m
- To: 67.5 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:67-67.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak zinc grade over a narrow interval in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak zinc grade for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 2.12

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-116)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 67 m
- To: 67.5 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:67-67.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a narrow interval as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 6.70

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-117)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 67 m
- To: 67.5 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:67-67.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a narrow interval in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.03

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-118)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 67 m
- To: 67.5 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:67-67.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a narrow interval in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-119)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 37
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 67 m
- To: 67.5 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:67-67.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a narrow interval in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: Narrow intercept length

- Negative factor: True width not determined

Evidence · table

> 37

Context: 0.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-120)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.73
- Grade Unit: %
- Intercept: 2.05 m
- From: 88.2 m
- To: 90.25 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:88.2-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.73

Context: 2.05

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-121)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.02
- Grade Unit: %
- Intercept: 2.05 m
- From: 88.2 m
- To: 90.25 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:88.2-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong zinc grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Strong zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 10.02

Context: 2.05

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-122)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.76
- Grade Unit: g/t
- Intercept: 2.05 m
- From: 88.2 m
- To: 90.25 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:88.2-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 3.76

Context: 2.05

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-123)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 2.05 m
- From: 88.2 m
- To: 90.25 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:88.2-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.01

Context: 2.05

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-124)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 2.05 m
- From: 88.2 m
- To: 90.25 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:88.2-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.02

Context: 2.05

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-125)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 115
- Grade Unit: ppm
- Intercept: 2.05 m
- From: 88.2 m
- To: 90.25 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:88.2-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 115

Context: 2.05

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-126)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 5 m
- From: 97 m
- To: 102 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:97-102
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak copper grade over a moderate length in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Weak copper grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 0.13

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-127)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 5 m
- From: 97 m
- To: 102 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:97-102
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Very low zinc grade over a moderate length in a new VMS discovery.

- Positive factor: Part of a new VMS discovery

- Negative factor: Very low zinc grade

- Negative factor: True width not determined

Evidence · table

> 0.08

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-128)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 22.31
- Grade Unit: g/t
- Intercept: 5 m
- From: 97 m
- To: 102 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:97-102
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade over a moderate length as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 22.31

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-129)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: g/t
- Intercept: 5 m
- From: 97 m
- To: 102 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:97-102
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade over a moderate length in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.12

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-130)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.39
- Grade Unit: %
- Intercept: 5 m
- From: 97 m
- To: 102 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:97-102
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade over a moderate length in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.39

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-131)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8
- Grade Unit: ppm
- Intercept: 5 m
- From: 97 m
- To: 102 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:97-102
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct over a moderate length in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 8

Context: 5.00

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-132)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.29
- Grade Unit: %
- Intercept: 2.55 m
- From: 115.95 m
- To: 118.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:115.95-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong copper grade within a new VMS discovery.

- Positive factor: Strong copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 1.29

Context: 2.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-133)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12.38
- Grade Unit: %
- Intercept: 2.55 m
- From: 115.95 m
- To: 118.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:115.95-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Strong zinc grade within a new VMS discovery.

- Positive factor: Strong zinc grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 12.38

Context: 2.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-134)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.47
- Grade Unit: g/t
- Intercept: 2.55 m
- From: 115.95 m
- To: 118.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:115.95-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Weak silver grade as a byproduct in a new VMS discovery.

- Positive factor: Silver present as a byproduct in a new VMS discovery

- Negative factor: Weak silver grade for VMS deposit type

- Negative factor: True width not determined

Evidence · table

> 7.47

Context: 2.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-135)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 2.55 m
- From: 115.95 m
- To: 118.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:115.95-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace gold grade in a new VMS discovery.

- Positive factor: Gold present as a trace element in a new VMS discovery

- Negative factor: Very low gold grade

- Negative factor: True width not determined

Evidence · table

> 0.04

Context: 2.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-136)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 2.55 m
- From: 115.95 m
- To: 118.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:115.95-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Trace lead grade in a new VMS discovery.

- Positive factor: Lead present as a trace element in a new VMS discovery

- Negative factor: Very low lead grade

- Negative factor: True width not determined

Evidence · table

> 0.28

Context: 2.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-137)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 155
- Grade Unit: ppm
- Intercept: 2.55 m
- From: 115.95 m
- To: 118.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:115.95-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Cobalt present as a byproduct in a new VMS discovery.

- Positive factor: Cobalt present as a byproduct in a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 155

Context: 2.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-138)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.53
- Grade Unit: %
- Intercept: 1.5 m
- From: 135 m
- To: 136.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Program: exploration
- Sample Type: drill
- Group ID: Rush-009:135-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Moderate copper grade in a new VMS discovery, contributing to overall project potential.

- Positive factor: Moderate copper grade for VMS deposit type

- Positive factor: Part of a new VMS discovery

- Negative factor: True width not determined

Evidence · table

> 0.53

Context: 1.50

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-139)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12.55
- Grade Unit: %
- Intercept: 1.5 m
- From: 135 m
- To: 136.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 12.55 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 18.8 %·m is weak \(grade alone is strong; the better of the two is used\).

- Positive factor: 12.55 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 12.55

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-140)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8.7
- Grade Unit: g/t
- Intercept: 1.5 m
- From: 135 m
- To: 136.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 13.0 g/t·m is below.

- Negative factor: 8.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.70

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-141)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 1.5 m
- From: 135 m
- To: 136.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-142)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 1.5 m
- From: 135 m
- To: 136.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.6 %·m is below.

- Negative factor: 0.4 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.40

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-143)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 139
- Grade Unit: ppm
- Intercept: 1.5 m
- From: 135 m
- To: 136.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 139 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 139

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-144)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 3.75 m
- From: 172.75 m
- To: 176.5 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.7 %·m is below.

- Negative factor: 0.18 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.18

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-145)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.31
- Grade Unit: %
- Intercept: 3.75 m
- From: 172.75 m
- To: 176.5 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.31 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 19.9 %·m is weak \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.31

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-146)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.31
- Grade Unit: g/t
- Intercept: 3.75 m
- From: 172.75 m
- To: 176.5 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.31 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 12.4 g/t·m is below.

- Negative factor: 3.31 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.31

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-147)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 3.75 m
- From: 172.75 m
- To: 176.5 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-148)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 3.75 m
- From: 172.75 m
- To: 176.5 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-149)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 40
- Grade Unit: ppm
- Intercept: 3.75 m
- From: 172.75 m
- To: 176.5 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 40 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 40

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-150)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 1 m
- From: 178 m
- To: 179 m
- Intercept Depth: 178 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-151)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.35
- Grade Unit: %
- Intercept: 1 m
- From: 178 m
- To: 179 m
- Intercept Depth: 178 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.35 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 7.3 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.35

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-152)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.05
- Grade Unit: g/t
- Intercept: 1 m
- From: 178 m
- To: 179 m
- Intercept Depth: 178 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.05 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 2.05 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.05

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-153)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 1 m
- From: 178 m
- To: 179 m
- Intercept Depth: 178 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-154)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 178 m
- To: 179 m
- Intercept Depth: 178 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-155)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 43
- Grade Unit: ppm
- Intercept: 1 m
- From: 178 m
- To: 179 m
- Intercept Depth: 178 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 43 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 43

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-156)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.78
- Grade Unit: %
- Intercept: 27 m
- From: 18 m
- To: 45 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.78 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 21.1 %·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.78

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-157)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.91
- Grade Unit: %
- Intercept: 27 m
- From: 18 m
- To: 45 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.91 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 51.6 %·m is moderate \(grade alone is below; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.91

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-158)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12.71
- Grade Unit: g/t
- Intercept: 27 m
- From: 18 m
- To: 45 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 12.71 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 343.2 g/t·m is weak \(grade alone is below; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 12.71

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-159)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 27 m
- From: 18 m
- To: 45 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-160)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.53
- Grade Unit: %
- Intercept: 27 m
- From: 18 m
- To: 45 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.53 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 14.3 %·m is weak \(grade alone is below; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.53

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-161)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 40
- Grade Unit: ppm
- Intercept: 27 m
- From: 18 m
- To: 45 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 40 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-162)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.9
- Grade Unit: %
- Intercept: 4 m
- From: 21.5 m
- To: 25.5 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 3.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.90

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-163)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.99
- Grade Unit: %
- Intercept: 4 m
- From: 21.5 m
- To: 25.5 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.99 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 40.0 %·m is weak \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.99

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-164)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18.79
- Grade Unit: g/t
- Intercept: 4 m
- From: 21.5 m
- To: 25.5 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 18.79 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 75.2 g/t·m is below.

- Negative factor: 18.79 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 18.79

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-165)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 4 m
- From: 21.5 m
- To: 25.5 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-166)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.6
- Grade Unit: %
- Intercept: 4 m
- From: 21.5 m
- To: 25.5 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.6 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 10.4 %·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.60

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-167)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 85
- Grade Unit: ppm
- Intercept: 4 m
- From: 21.5 m
- To: 25.5 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 85 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 85

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-168)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.41
- Grade Unit: %
- Intercept: 10.5 m
- From: 34.5 m
- To: 45 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.41 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 14.8 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.41

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-169)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.61
- Grade Unit: %
- Intercept: 10.5 m
- From: 34.5 m
- To: 45 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.61 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 6.4 %·m is below.

- Negative factor: 0.61 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.61

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-170)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 21.39
- Grade Unit: g/t
- Intercept: 10.5 m
- From: 34.5 m
- To: 45 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 21.39 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 224.6 g/t·m is weak \(grade alone is below; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 21.39

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-171)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 10.5 m
- From: 34.5 m
- To: 45 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 1.1 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-172)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 10.5 m
- From: 34.5 m
- To: 45 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 1.6 %·m is below.

- Negative factor: 0.15 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-173)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 51
- Grade Unit: ppm
- Intercept: 10.5 m
- From: 34.5 m
- To: 45 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 51 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 51

Context: including

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-174)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.48
- Grade Unit: %
- Intercept: 2 m
- From: 94 m
- To: 96 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.48 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.0 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.48

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-175)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 2 m
- From: 94 m
- To: 96 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.05 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-176)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.99
- Grade Unit: g/t
- Intercept: 2 m
- From: 94 m
- To: 96 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.99 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 0.99 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.99

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-177)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 2 m
- From: 94 m
- To: 96 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-178)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 2 m
- From: 94 m
- To: 96 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-179)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 2 m
- From: 94 m
- To: 96 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-180)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 1 m
- From: 29 m
- To: 30 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:29-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-181)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 29 m
- To: 30 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:29-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-182)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.5
- Grade Unit: g/t
- Intercept: 1 m
- From: 29 m
- To: 30 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:29-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.5 g/t·m is below.

- Negative factor: 1.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.50

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-183)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 29 m
- To: 30 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:29-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-184)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 29 m
- To: 30 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:29-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-185)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 1 m
- From: 29 m
- To: 30 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:29-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-186)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.46
- Grade Unit: %
- Intercept: 0.47 m
- From: 31.53 m
- To: 32 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:31.53-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.46 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.46

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-187)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.76
- Grade Unit: %
- Intercept: 0.47 m
- From: 31.53 m
- To: 32 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:31.53-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.76 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.76

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-188)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.47 m
- From: 31.53 m
- To: 32 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:31.53-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.9 g/t·m is below.

- Negative factor: 4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.00

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-189)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.47 m
- From: 31.53 m
- To: 32 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:31.53-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-190)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.47 m
- From: 31.53 m
- To: 32 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:31.53-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-191)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 123
- Grade Unit: ppm
- Intercept: 0.47 m
- From: 31.53 m
- To: 32 m
- Intercept Depth: 31.53 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:31.53-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 123 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 123

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-192)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.59
- Grade Unit: %
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.59 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.59

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-193)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.34
- Grade Unit: %
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.34 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.7 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.34

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-194)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.6 g/t·m is below.

- Negative factor: 5.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.30

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-195)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-196)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-197)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 95
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 95 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 95

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-198)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.43
- Grade Unit: %
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.43 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.43

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-199)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.46
- Grade Unit: %
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.46 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.7 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.46

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-200)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.2 g/t·m is below.

- Negative factor: 4.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.40

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-201)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-202)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-203)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 129
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 129 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 129

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-204)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.12
- Grade Unit: %
- Intercept: 0.3 m
- From: 33 m
- To: 33.3 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.12 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.12

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-205)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.02
- Grade Unit: %
- Intercept: 0.3 m
- From: 33 m
- To: 33.3 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 1.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-206)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 33 m
- To: 33.3 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.1 g/t·m is below.

- Negative factor: 7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.00

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-207)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.3 m
- From: 33 m
- To: 33.3 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-208)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.3 m
- From: 33 m
- To: 33.3 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-209)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 84
- Grade Unit: ppm
- Intercept: 0.3 m
- From: 33 m
- To: 33.3 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33-33.3
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 84 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 84

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-210)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 0.7 m
- From: 33.3 m
- To: 34 m
- Intercept Depth: 33.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33.3-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.23 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.23

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-211)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.7 m
- From: 33.3 m
- To: 34 m
- Intercept Depth: 33.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33.3-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-212)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.4
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 33.3 m
- To: 34 m
- Intercept Depth: 33.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33.3-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.7 g/t·m is below.

- Negative factor: 2.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.40

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-213)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 33.3 m
- To: 34 m
- Intercept Depth: 33.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33.3-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-214)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.7 m
- From: 33.3 m
- To: 34 m
- Intercept Depth: 33.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33.3-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-215)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 19
- Grade Unit: ppm
- Intercept: 0.7 m
- From: 33.3 m
- To: 34 m
- Intercept Depth: 33.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:33.3-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 19 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 19

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-216)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.43
- Grade Unit: %
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.43 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.4 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.43

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-217)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-218)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 36
- Grade Unit: g/t
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 36 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 36.0 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 36.00

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-219)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-220)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.07
- Grade Unit: %
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.07 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 1.1 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.07

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-221)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-222)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-223)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-224)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: g/t
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 11 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 11.0 g/t·m is below.

- Negative factor: 11 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 11.00

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-225)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-226)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.39
- Grade Unit: %
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.39 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.4 %·m is below.

- Negative factor: 0.39 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.39

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-227)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 17
- Grade Unit: ppm
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 17 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 17

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-228)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- From: 55 m
- To: 56 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:55-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-229)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 1 m
- From: 55 m
- To: 56 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:55-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.07 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-230)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.8
- Grade Unit: g/t
- Intercept: 1 m
- From: 55 m
- To: 56 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:55-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.8 g/t·m is below.

- Negative factor: 2.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.80

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-231)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 55 m
- To: 56 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:55-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-232)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 55 m
- To: 56 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:55-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-233)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 1 m
- From: 55 m
- To: 56 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:55-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-234)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 1 m
- From: 56 m
- To: 57 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:56-57
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-235)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 1 m
- From: 56 m
- To: 57 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:56-57
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-236)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.4
- Grade Unit: g/t
- Intercept: 1 m
- From: 56 m
- To: 57 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:56-57
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 1.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.40

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-237)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 56 m
- To: 57 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:56-57
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-238)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 56 m
- To: 57 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:56-57
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-239)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 1 m
- From: 56 m
- To: 57 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:56-57
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-240)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.34
- Grade Unit: %
- Intercept: 0.53 m
- From: 61.47 m
- To: 62 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:61.47-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.34 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.34 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.34

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-241)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.36
- Grade Unit: %
- Intercept: 0.53 m
- From: 61.47 m
- To: 62 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:61.47-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.36 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 5.5 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 10.36 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.36

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-242)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.5
- Grade Unit: g/t
- Intercept: 0.53 m
- From: 61.47 m
- To: 62 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:61.47-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.3 g/t·m is below.

- Negative factor: 2.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.50

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-243)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 0.53 m
- From: 61.47 m
- To: 62 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:61.47-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-244)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.53 m
- From: 61.47 m
- To: 62 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:61.47-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-245)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 160
- Grade Unit: ppm
- Intercept: 0.53 m
- From: 61.47 m
- To: 62 m
- Intercept Depth: 61.47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:61.47-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 160 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 160

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-246)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.7
- Grade Unit: %
- Intercept: 0.5 m
- From: 62 m
- To: 62.5 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62-62.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.7 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.70

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-247)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.21
- Grade Unit: %
- Intercept: 0.5 m
- From: 62 m
- To: 62.5 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62-62.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.21 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.21

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-248)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 62 m
- To: 62.5 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62-62.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 2.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.80

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-249)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 62 m
- To: 62.5 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62-62.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-250)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 62 m
- To: 62.5 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62-62.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-251)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 163
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 62 m
- To: 62.5 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62-62.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 163 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 163

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-252)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.93
- Grade Unit: %
- Intercept: 0.5 m
- From: 62.5 m
- To: 63 m
- Intercept Depth: 62.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62.5-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.93 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.5 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.93

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-253)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.91
- Grade Unit: %
- Intercept: 0.5 m
- From: 62.5 m
- To: 63 m
- Intercept Depth: 62.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62.5-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.91 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 5.5 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 10.91 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.91

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-254)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 62.5 m
- To: 63 m
- Intercept Depth: 62.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62.5-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 4.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.10

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-255)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 62.5 m
- To: 63 m
- Intercept Depth: 62.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62.5-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-256)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 62.5 m
- To: 63 m
- Intercept Depth: 62.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62.5-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-257)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 175
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 62.5 m
- To: 63 m
- Intercept Depth: 62.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:62.5-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 175 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 175

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-258)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.49
- Grade Unit: %
- Intercept: 0.5 m
- From: 63 m
- To: 63.5 m
- Intercept Depth: 63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:63-63.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.49 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.7 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.49

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-259)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.82
- Grade Unit: %
- Intercept: 0.5 m
- From: 63 m
- To: 63.5 m
- Intercept Depth: 63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:63-63.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.82 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.9 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.82

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-260)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 63 m
- To: 63.5 m
- Intercept Depth: 63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:63-63.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.0 g/t·m is below.

- Negative factor: 6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.00

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-261)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 63 m
- To: 63.5 m
- Intercept Depth: 63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:63-63.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-262)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 63 m
- To: 63.5 m
- Intercept Depth: 63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:63-63.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-263)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 178
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 63 m
- To: 63.5 m
- Intercept Depth: 63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:63-63.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 178 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 178

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-264)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.61
- Grade Unit: %
- Intercept: 0.5 m
- From: 64 m
- To: 64.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:64-64.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.61 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.61

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-265)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.66
- Grade Unit: %
- Intercept: 0.5 m
- From: 64 m
- To: 64.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:64-64.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.66 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 5.3 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 10.66 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.66

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-266)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 64 m
- To: 64.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:64-64.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.5 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.00

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-267)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 64 m
- To: 64.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:64-64.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-268)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 64 m
- To: 64.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:64-64.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-269)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 177
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 64 m
- To: 64.5 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:64-64.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 177 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 177

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-270)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.27
- Grade Unit: %
- Intercept: 1 m
- From: 67 m
- To: 68 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:67-68
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.27 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.27

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-271)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 1 m
- From: 67 m
- To: 68 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:67-68
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-272)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 1 m
- From: 67 m
- To: 68 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:67-68
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.3 g/t·m is below.

- Negative factor: 1.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.30

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-273)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 67 m
- To: 68 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:67-68
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-274)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 1 m
- From: 67 m
- To: 68 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:67-68
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.05 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-275)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 1 m
- From: 67 m
- To: 68 m
- Intercept Depth: 67 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:67-68
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-276)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 0.41 m
- From: 70 m
- To: 70.41 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:70-70.41
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-277)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.68
- Grade Unit: %
- Intercept: 0.41 m
- From: 70 m
- To: 70.41 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:70-70.41
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.68 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 1.5 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.68

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-278)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 0.41 m
- From: 70 m
- To: 70.41 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:70-70.41
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.5 g/t·m is below.

- Negative factor: 1.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.10

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-279)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.41 m
- From: 70 m
- To: 70.41 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:70-70.41
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-280)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.41 m
- From: 70 m
- To: 70.41 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:70-70.41
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-281)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 71
- Grade Unit: ppm
- Intercept: 0.41 m
- From: 70 m
- To: 70.41 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:70-70.41
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 71 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 71

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-282)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.94
- Grade Unit: %
- Intercept: 0.56 m
- From: 71.94 m
- To: 72.5 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:71.94-72.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.94 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.5 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.94

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-283)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11.86
- Grade Unit: %
- Intercept: 0.56 m
- From: 71.94 m
- To: 72.5 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:71.94-72.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 11.86 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 6.6 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 11.86 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 11.86

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-284)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.4
- Grade Unit: g/t
- Intercept: 0.56 m
- From: 71.94 m
- To: 72.5 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:71.94-72.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.5 g/t·m is below.

- Negative factor: 4.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.40

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-285)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.56 m
- From: 71.94 m
- To: 72.5 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:71.94-72.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-286)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.56 m
- From: 71.94 m
- To: 72.5 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:71.94-72.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-287)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 128
- Grade Unit: ppm
- Intercept: 0.56 m
- From: 71.94 m
- To: 72.5 m
- Intercept Depth: 71.94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:71.94-72.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 128 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 128

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-288)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.59
- Grade Unit: %
- Intercept: 0.5 m
- From: 72.5 m
- To: 73 m
- Intercept Depth: 72.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:72.5-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.59 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.59

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-289)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11.66
- Grade Unit: %
- Intercept: 0.5 m
- From: 72.5 m
- To: 73 m
- Intercept Depth: 72.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:72.5-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 11.66 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 5.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 11.66 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 11.66

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-290)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 72.5 m
- To: 73 m
- Intercept Depth: 72.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:72.5-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.00

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-291)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 72.5 m
- To: 73 m
- Intercept Depth: 72.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:72.5-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-292)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 0.5 m
- From: 72.5 m
- To: 73 m
- Intercept Depth: 72.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:72.5-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.05 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-293)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 44
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 72.5 m
- To: 73 m
- Intercept Depth: 72.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:72.5-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 44 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 44

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-294)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.49
- Grade Unit: %
- Intercept: 0.49 m
- From: 73 m
- To: 73.49 m
- Intercept Depth: 73 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:73-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.49 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.49

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-295)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.6
- Grade Unit: %
- Intercept: 0.49 m
- From: 73 m
- To: 73.49 m
- Intercept Depth: 73 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:73-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.6 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.2 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.60

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-296)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.49 m
- From: 73 m
- To: 73.49 m
- Intercept Depth: 73 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:73-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.5 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.00

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-297)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.49 m
- From: 73 m
- To: 73.49 m
- Intercept Depth: 73 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:73-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-298)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.49 m
- From: 73 m
- To: 73.49 m
- Intercept Depth: 73 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:73-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-299)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 63
- Grade Unit: ppm
- Intercept: 0.49 m
- From: 73 m
- To: 73.49 m
- Intercept Depth: 73 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:73-73.49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 63 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 63

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-300)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 1 m
- From: 88 m
- To: 89 m
- Intercept Depth: 88 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:88-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-301)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 88 m
- To: 89 m
- Intercept Depth: 88 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:88-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-302)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.6
- Grade Unit: g/t
- Intercept: 1 m
- From: 88 m
- To: 89 m
- Intercept Depth: 88 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:88-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.6 g/t·m is below.

- Negative factor: 1.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.60

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-303)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 88 m
- To: 89 m
- Intercept Depth: 88 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:88-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-304)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 1 m
- From: 88 m
- To: 89 m
- Intercept Depth: 88 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:88-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-305)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: ppm
- Intercept: 1 m
- From: 88 m
- To: 89 m
- Intercept Depth: 88 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:88-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 4 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 4

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-306)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 1 m
- From: 116 m
- To: 117 m
- Intercept Depth: 116 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:116-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.26 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.26 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.26

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-307)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 116 m
- To: 117 m
- Intercept Depth: 116 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:116-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-308)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 14.4
- Grade Unit: g/t
- Intercept: 1 m
- From: 116 m
- To: 117 m
- Intercept Depth: 116 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:116-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 14.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 14.4 g/t·m is below.

- Negative factor: 14.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 14.40

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-309)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: g/t
- Intercept: 1 m
- From: 116 m
- To: 117 m
- Intercept Depth: 116 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:116-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.07 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-310)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 1 m
- From: 116 m
- To: 117 m
- Intercept Depth: 116 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:116-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-311)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16
- Grade Unit: ppm
- Intercept: 1 m
- From: 116 m
- To: 117 m
- Intercept Depth: 116 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:116-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 16 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 16

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-312)

Rush target · copper

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 134 m
- To: 135 m
- Intercept Depth: 134 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:134-135
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-313)

Rush target · zinc

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 134 m
- To: 135 m
- Intercept Depth: 134 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:134-135
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-314)

Rush target · silver

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.8
- Grade Unit: g/t
- Intercept: 1 m
- From: 134 m
- To: 135 m
- Intercept Depth: 134 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:134-135
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 0.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.80

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-315)

Rush target · gold

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 134 m
- To: 135 m
- Intercept Depth: 134 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:134-135
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-316)

Rush target · lead

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1 m
- From: 134 m
- To: 135 m
- Intercept Depth: 134 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:134-135
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-317)

Rush target · cobalt

#### Identity

- Hole ID: Rush-001
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10
- Grade Unit: ppm
- Intercept: 1 m
- From: 134 m
- To: 135 m
- Intercept Depth: 134 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-001:134-135
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 10 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 10

Context: Rush-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-318)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 1 m
- From: 23 m
- To: 24 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:23-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.16 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-319)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 1 m
- From: 23 m
- To: 24 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:23-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-320)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: g/t
- Intercept: 1 m
- From: 23 m
- To: 24 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:23-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.0 g/t·m is below.

- Negative factor: 6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-321)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 23 m
- To: 24 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:23-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-322)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 23 m
- To: 24 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:23-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-323)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 31
- Grade Unit: ppm
- Intercept: 1 m
- From: 23 m
- To: 24 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:23-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 31 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 31

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-324)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 31 m
- To: 32 m
- Intercept Depth: 31 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:31-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-325)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 1 m
- From: 31 m
- To: 32 m
- Intercept Depth: 31 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:31-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-326)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.9
- Grade Unit: g/t
- Intercept: 1 m
- From: 31 m
- To: 32 m
- Intercept Depth: 31 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:31-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.9 g/t·m is below.

- Negative factor: 1.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.90

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-327)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 31 m
- To: 32 m
- Intercept Depth: 31 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:31-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-328)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 31 m
- To: 32 m
- Intercept Depth: 31 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:31-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-329)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 28
- Grade Unit: ppm
- Intercept: 1 m
- From: 31 m
- To: 32 m
- Intercept Depth: 31 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:31-32
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 28 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 28

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-330)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 1 m
- From: 32 m
- To: 33 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:32-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-331)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 1 m
- From: 32 m
- To: 33 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:32-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-332)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 1 m
- From: 32 m
- To: 33 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:32-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.2 g/t·m is below.

- Negative factor: 1.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.20

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-333)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 32 m
- To: 33 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:32-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-334)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 32 m
- To: 33 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:32-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-335)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 1 m
- From: 32 m
- To: 33 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:32-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-336)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 1 m
- From: 34 m
- To: 35 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:34-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.17 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-337)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 1 m
- From: 34 m
- To: 35 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:34-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-338)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 1 m
- From: 34 m
- To: 35 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:34-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.1 g/t·m is below.

- Negative factor: 1.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-339)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 34 m
- To: 35 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:34-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-340)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 34 m
- To: 35 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:34-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-341)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 20
- Grade Unit: ppm
- Intercept: 1 m
- From: 34 m
- To: 35 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:34-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 20 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 20

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-342)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 1 m
- From: 35 m
- To: 36 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:35-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-343)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 35 m
- To: 36 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:35-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-344)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 1 m
- From: 35 m
- To: 36 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:35-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.0 g/t·m is below.

- Negative factor: 1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-345)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 35 m
- To: 36 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:35-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-346)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 35 m
- To: 36 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:35-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-347)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 1 m
- From: 35 m
- To: 36 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:35-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-348)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.68
- Grade Unit: %
- Intercept: 0.84 m
- From: 43.44 m
- To: 44.28 m
- Intercept Depth: 43.44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:43.44-44.28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.68 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.68

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-349)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.84 m
- From: 43.44 m
- To: 44.28 m
- Intercept Depth: 43.44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:43.44-44.28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.06 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-350)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 51
- Grade Unit: g/t
- Intercept: 0.84 m
- From: 43.44 m
- To: 44.28 m
- Intercept Depth: 43.44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:43.44-44.28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 51 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 42.8 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 51.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-351)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 0.84 m
- From: 43.44 m
- To: 44.28 m
- Intercept Depth: 43.44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:43.44-44.28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-352)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.48
- Grade Unit: %
- Intercept: 0.84 m
- From: 43.44 m
- To: 44.28 m
- Intercept Depth: 43.44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:43.44-44.28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.48 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 2.1 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.48

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-353)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 0.84 m
- From: 43.44 m
- To: 44.28 m
- Intercept Depth: 43.44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:43.44-44.28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-354)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.15 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-355)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.06 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-356)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.2
- Grade Unit: g/t
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.2 g/t·m is below.

- Negative factor: 5.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.20

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-357)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-358)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-359)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9
- Grade Unit: ppm
- Intercept: 1 m
- From: 50 m
- To: 51 m
- Intercept Depth: 50 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:50-51
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 9 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 9

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-360)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 0.58 m
- From: 54.42 m
- To: 55 m
- Intercept Depth: 54.42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:54.42-55
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.28 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-361)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 0.58 m
- From: 54.42 m
- To: 55 m
- Intercept Depth: 54.42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:54.42-55
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-362)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.2
- Grade Unit: g/t
- Intercept: 0.58 m
- From: 54.42 m
- To: 55 m
- Intercept Depth: 54.42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:54.42-55
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.2 g/t·m is below.

- Negative factor: 7.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.20

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-363)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.58 m
- From: 54.42 m
- To: 55 m
- Intercept Depth: 54.42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:54.42-55
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-364)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.58 m
- From: 54.42 m
- To: 55 m
- Intercept Depth: 54.42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:54.42-55
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-365)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 27
- Grade Unit: ppm
- Intercept: 0.58 m
- From: 54.42 m
- To: 55 m
- Intercept Depth: 54.42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:54.42-55
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 27 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 27

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-366)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.39
- Grade Unit: %
- Intercept: 0.5 m
- From: 55 m
- To: 55.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55-55.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.39 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.7 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.39

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-367)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.46
- Grade Unit: %
- Intercept: 0.5 m
- From: 55 m
- To: 55.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55-55.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.46 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.46 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.46

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-368)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 37.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 55 m
- To: 55.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55-55.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 37.1 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 18.6 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 37.10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-369)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 55 m
- To: 55.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55-55.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.11 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-370)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 55 m
- To: 55.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55-55.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-371)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 27
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 55 m
- To: 55.5 m
- Intercept Depth: 55 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55-55.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 27 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 27

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-372)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.81
- Grade Unit: %
- Intercept: 0.5 m
- From: 55.5 m
- To: 56 m
- Intercept Depth: 55.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55.5-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.81 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.4 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.81

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-373)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.33
- Grade Unit: %
- Intercept: 0.5 m
- From: 55.5 m
- To: 56 m
- Intercept Depth: 55.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55.5-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.33 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.33

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-374)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 34.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 55.5 m
- To: 56 m
- Intercept Depth: 55.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55.5-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 34.3 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 17.1 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 34.30

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-375)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.49
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 55.5 m
- To: 56 m
- Intercept Depth: 55.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55.5-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.49 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.2 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.49

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-376)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 55.5 m
- To: 56 m
- Intercept Depth: 55.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55.5-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-377)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 55.5 m
- To: 56 m
- Intercept Depth: 55.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:55.5-56
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 16 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 16

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-378)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.77
- Grade Unit: %
- Intercept: 0.5 m
- From: 56 m
- To: 56.5 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:56-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.77 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.4 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.77

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-379)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 0.5 m
- From: 56 m
- To: 56.5 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:56-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.28 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-380)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 23.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 56 m
- To: 56.5 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:56-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 23.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 11.9 g/t·m is below.

- Negative factor: 23.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 23.90

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-381)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 56 m
- To: 56.5 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:56-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.13 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-382)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 56 m
- To: 56.5 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:56-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-383)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 56 m
- To: 56.5 m
- Intercept Depth: 56 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:56-56.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-384)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.5 m
- From: 58.5 m
- To: 59 m
- Intercept Depth: 58.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:58.5-59
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.3 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.30

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-385)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 0.5 m
- From: 58.5 m
- To: 59 m
- Intercept Depth: 58.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:58.5-59
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.18 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.18

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-386)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 58.5 m
- To: 59 m
- Intercept Depth: 58.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:58.5-59
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.3 g/t·m is below.

- Negative factor: 2.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.50

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-387)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 58.5 m
- To: 59 m
- Intercept Depth: 58.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:58.5-59
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-388)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 58.5 m
- To: 59 m
- Intercept Depth: 58.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:58.5-59
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-389)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 81
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 58.5 m
- To: 59 m
- Intercept Depth: 58.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:58.5-59
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 81 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 81

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-390)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.33
- Grade Unit: %
- Intercept: 0.5 m
- From: 59 m
- To: 59.5 m
- Intercept Depth: 59 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59-59.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.33 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.33

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-391)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 59 m
- To: 59.5 m
- Intercept Depth: 59 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59-59.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.07 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-392)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 59 m
- To: 59.5 m
- Intercept Depth: 59 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59-59.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 2.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.90

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-393)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 59 m
- To: 59.5 m
- Intercept Depth: 59 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59-59.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-394)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.5 m
- From: 59 m
- To: 59.5 m
- Intercept Depth: 59 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59-59.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-395)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 59 m
- To: 59.5 m
- Intercept Depth: 59 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59-59.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 16 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 16

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-396)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 0.5 m
- From: 59.5 m
- To: 60 m
- Intercept Depth: 59.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59.5-60
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.21 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.21

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-397)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 0.5 m
- From: 59.5 m
- To: 60 m
- Intercept Depth: 59.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59.5-60
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.05 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-398)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 59.5 m
- To: 60 m
- Intercept Depth: 59.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59.5-60
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 1.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.50

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-399)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 59.5 m
- To: 60 m
- Intercept Depth: 59.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59.5-60
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-400)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 59.5 m
- To: 60 m
- Intercept Depth: 59.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59.5-60
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-401)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 25
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 59.5 m
- To: 60 m
- Intercept Depth: 59.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:59.5-60
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 25 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 25

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-402)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 60.5 m
- To: 61 m
- Intercept Depth: 60.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:60.5-61
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-403)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 60.5 m
- To: 61 m
- Intercept Depth: 60.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:60.5-61
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-404)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 60.5 m
- To: 61 m
- Intercept Depth: 60.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:60.5-61
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.5 g/t·m is below.

- Negative factor: 1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-405)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 60.5 m
- To: 61 m
- Intercept Depth: 60.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:60.5-61
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-406)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 60.5 m
- To: 61 m
- Intercept Depth: 60.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:60.5-61
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-407)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 60.5 m
- To: 61 m
- Intercept Depth: 60.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:60.5-61
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 10 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-408)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 61 m
- To: 61.5 m
- Intercept Depth: 61 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61-61.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-409)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 61 m
- To: 61.5 m
- Intercept Depth: 61 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61-61.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-410)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 61 m
- To: 61.5 m
- Intercept Depth: 61 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61-61.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 1.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-411)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 61 m
- To: 61.5 m
- Intercept Depth: 61 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61-61.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-412)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 61 m
- To: 61.5 m
- Intercept Depth: 61 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61-61.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-413)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 61 m
- To: 61.5 m
- Intercept Depth: 61 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61-61.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 10 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-414)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 0.5 m
- From: 61.5 m
- To: 62 m
- Intercept Depth: 61.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61.5-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.15 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-415)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 61.5 m
- To: 62 m
- Intercept Depth: 61.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61.5-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.07 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-416)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 61.5 m
- To: 62 m
- Intercept Depth: 61.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61.5-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 1.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.60

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-417)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 61.5 m
- To: 62 m
- Intercept Depth: 61.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61.5-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-418)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 61.5 m
- To: 62 m
- Intercept Depth: 61.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61.5-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-419)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 17
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 61.5 m
- To: 62 m
- Intercept Depth: 61.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:61.5-62
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 17 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 17

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-420)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.83
- Grade Unit: %
- Intercept: 0.7 m
- From: 69.3 m
- To: 70 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:69.3-70
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.83 % copper is strong against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.3 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.83 % copper is strong on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.83

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-421)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.68
- Grade Unit: %
- Intercept: 0.7 m
- From: 69.3 m
- To: 70 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:69.3-70
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.68 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 7.5 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 10.68 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.68

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-422)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.4
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 69.3 m
- To: 70 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:69.3-70
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.2 g/t·m is below.

- Negative factor: 7.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.40

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-423)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 69.3 m
- To: 70 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:69.3-70
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-424)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.7 m
- From: 69.3 m
- To: 70 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:69.3-70
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-425)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 127
- Grade Unit: ppm
- Intercept: 0.7 m
- From: 69.3 m
- To: 70 m
- Intercept Depth: 69.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:69.3-70
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 127 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 127

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-426)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-427)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.85
- Grade Unit: %
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.85 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.9 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.85

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-428)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.6 g/t·m is below.

- Negative factor: 5.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.20

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-429)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-430)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-431)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 163
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 163 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 163

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-432)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.65
- Grade Unit: %
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.65 % copper is exceptional against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.3 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 2.65 % copper is exceptional on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.65

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-433)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12.73
- Grade Unit: %
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 12.73 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 6.4 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 12.73 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 12.73

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-434)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.5 g/t·m is below.

- Negative factor: 9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-435)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-436)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-437)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 158
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 158 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 158

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-438)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.22
- Grade Unit: %
- Intercept: 0.5 m
- From: 71 m
- To: 71.5 m
- Intercept Depth: 71 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71-71.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.22 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.22

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-439)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 71 m
- To: 71.5 m
- Intercept Depth: 71 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71-71.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.07 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 5.0 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 10.07 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.07

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-440)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 71 m
- To: 71.5 m
- Intercept Depth: 71 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71-71.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.0 g/t·m is below.

- Negative factor: 6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-441)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 71 m
- To: 71.5 m
- Intercept Depth: 71 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71-71.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-442)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 71 m
- To: 71.5 m
- Intercept Depth: 71 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71-71.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-443)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 171
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 71 m
- To: 71.5 m
- Intercept Depth: 71 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71-71.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 171 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 171

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-444)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.69
- Grade Unit: %
- Intercept: 0.47 m
- From: 71.5 m
- To: 71.97 m
- Intercept Depth: 71.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.5-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.69 % copper is strong against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.69 % copper is strong on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.69

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-445)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8.63
- Grade Unit: %
- Intercept: 0.47 m
- From: 71.5 m
- To: 71.97 m
- Intercept Depth: 71.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.5-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8.63 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.1 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.63

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-446)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8
- Grade Unit: g/t
- Intercept: 0.47 m
- From: 71.5 m
- To: 71.97 m
- Intercept Depth: 71.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.5-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.8 g/t·m is below.

- Negative factor: 8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-447)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: g/t
- Intercept: 0.47 m
- From: 71.5 m
- To: 71.97 m
- Intercept Depth: 71.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.5-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.09 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-448)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.47 m
- From: 71.5 m
- To: 71.97 m
- Intercept Depth: 71.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.5-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-449)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 122
- Grade Unit: ppm
- Intercept: 0.47 m
- From: 71.5 m
- To: 71.97 m
- Intercept Depth: 71.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.5-71.97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 122 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 122

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-450)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 1.03 m
- From: 71.97 m
- To: 73 m
- Intercept Depth: 71.97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.97-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.28 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-451)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 1.03 m
- From: 71.97 m
- To: 73 m
- Intercept Depth: 71.97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.97-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.3 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.30

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-452)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.4
- Grade Unit: g/t
- Intercept: 1.03 m
- From: 71.97 m
- To: 73 m
- Intercept Depth: 71.97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.97-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.5 g/t·m is below.

- Negative factor: 2.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.40

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-453)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1.03 m
- From: 71.97 m
- To: 73 m
- Intercept Depth: 71.97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.97-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-454)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 1.03 m
- From: 71.97 m
- To: 73 m
- Intercept Depth: 71.97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.97-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-455)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: ppm
- Intercept: 1.03 m
- From: 71.97 m
- To: 73 m
- Intercept Depth: 71.97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:71.97-73
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 6 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 6

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-456)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 1 m
- From: 74 m
- To: 75 m
- Intercept Depth: 74 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:74-75
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-457)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 1 m
- From: 74 m
- To: 75 m
- Intercept Depth: 74 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:74-75
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-458)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 1 m
- From: 74 m
- To: 75 m
- Intercept Depth: 74 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:74-75
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.1 g/t·m is below.

- Negative factor: 1.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-459)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 1 m
- From: 74 m
- To: 75 m
- Intercept Depth: 74 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:74-75
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-460)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 1 m
- From: 74 m
- To: 75 m
- Intercept Depth: 74 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:74-75
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-461)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7
- Grade Unit: ppm
- Intercept: 1 m
- From: 74 m
- To: 75 m
- Intercept Depth: 74 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:74-75
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 7 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 7

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-462)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 0.95 m
- From: 75 m
- To: 75.95 m
- Intercept Depth: 75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75-75.95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.25 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.25 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.25

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-463)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.61
- Grade Unit: %
- Intercept: 0.95 m
- From: 75 m
- To: 75.95 m
- Intercept Depth: 75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75-75.95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.61 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.6 %·m is below.

- Negative factor: 0.61 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.61

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-464)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.95 m
- From: 75 m
- To: 75.95 m
- Intercept Depth: 75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75-75.95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.8 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-465)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.95 m
- From: 75 m
- To: 75.95 m
- Intercept Depth: 75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75-75.95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-466)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 0.95 m
- From: 75 m
- To: 75.95 m
- Intercept Depth: 75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75-75.95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-467)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 28
- Grade Unit: ppm
- Intercept: 0.95 m
- From: 75 m
- To: 75.95 m
- Intercept Depth: 75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75-75.95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 28 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 28

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-468)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.37
- Grade Unit: %
- Intercept: 0.55 m
- From: 75.95 m
- To: 76.5 m
- Intercept Depth: 75.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75.95-76.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.37 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.37 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.37

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-469)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8.31
- Grade Unit: %
- Intercept: 0.55 m
- From: 75.95 m
- To: 76.5 m
- Intercept Depth: 75.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75.95-76.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8.31 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.31

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-470)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.55 m
- From: 75.95 m
- To: 76.5 m
- Intercept Depth: 75.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75.95-76.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.7 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-471)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.55 m
- From: 75.95 m
- To: 76.5 m
- Intercept Depth: 75.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75.95-76.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-472)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.55 m
- From: 75.95 m
- To: 76.5 m
- Intercept Depth: 75.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75.95-76.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-473)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 70
- Grade Unit: ppm
- Intercept: 0.55 m
- From: 75.95 m
- To: 76.5 m
- Intercept Depth: 75.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:75.95-76.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 70 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 70

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-474)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.27
- Grade Unit: %
- Intercept: 0.5 m
- From: 76.5 m
- To: 77 m
- Intercept Depth: 76.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:76.5-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.27 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.27

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-475)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.97
- Grade Unit: %
- Intercept: 0.5 m
- From: 76.5 m
- To: 77 m
- Intercept Depth: 76.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:76.5-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.97 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.0 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.97

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-476)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 76.5 m
- To: 77 m
- Intercept Depth: 76.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:76.5-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.9 g/t·m is below.

- Negative factor: 1.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.90

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-477)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 76.5 m
- To: 77 m
- Intercept Depth: 76.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:76.5-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-478)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 76.5 m
- To: 77 m
- Intercept Depth: 76.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:76.5-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-479)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 60
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 76.5 m
- To: 77 m
- Intercept Depth: 76.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:76.5-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 60 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 60

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-480)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.49
- Grade Unit: %
- Intercept: 0.5 m
- From: 77 m
- To: 77.5 m
- Intercept Depth: 77 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77-77.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.49 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.49

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-481)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12
- Grade Unit: %
- Intercept: 0.5 m
- From: 77 m
- To: 77.5 m
- Intercept Depth: 77 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77-77.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 12 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 6.0 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 12 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 12.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-482)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 77 m
- To: 77.5 m
- Intercept Depth: 77 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77-77.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.6 g/t·m is below.

- Negative factor: 3.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.30

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-483)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 77 m
- To: 77.5 m
- Intercept Depth: 77 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77-77.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-484)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 77 m
- To: 77.5 m
- Intercept Depth: 77 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77-77.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-485)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 88
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 77 m
- To: 77.5 m
- Intercept Depth: 77 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77-77.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 88 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 88

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-486)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.74
- Grade Unit: %
- Intercept: 0.5 m
- From: 77.5 m
- To: 78 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77.5-78
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.74 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.4 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.74

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-487)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.98
- Grade Unit: %
- Intercept: 0.5 m
- From: 77.5 m
- To: 78 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77.5-78
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.98 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.5 %·m is below.

- Negative factor: 0.98 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.98

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-488)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 77.5 m
- To: 78 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77.5-78
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.3 g/t·m is below.

- Negative factor: 4.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.60

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-489)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 77.5 m
- To: 78 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77.5-78
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-490)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 77.5 m
- To: 78 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77.5-78
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-491)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 25
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 77.5 m
- To: 78 m
- Intercept Depth: 77.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:77.5-78
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 25 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 25

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-492)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.57
- Grade Unit: %
- Intercept: 0.5 m
- From: 78 m
- To: 78.5 m
- Intercept Depth: 78 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.57 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.57

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-493)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.05
- Grade Unit: %
- Intercept: 0.5 m
- From: 78 m
- To: 78.5 m
- Intercept Depth: 78 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.05 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 2.5 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.05

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-494)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 78 m
- To: 78.5 m
- Intercept Depth: 78 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-495)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 78 m
- To: 78.5 m
- Intercept Depth: 78 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-496)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 0.5 m
- From: 78 m
- To: 78.5 m
- Intercept Depth: 78 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.09 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-497)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 56
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 78 m
- To: 78.5 m
- Intercept Depth: 78 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78-78.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 56 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 56

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-498)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 78.5 m
- To: 79 m
- Intercept Depth: 78.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78.5-79
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-499)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.54
- Grade Unit: %
- Intercept: 0.5 m
- From: 78.5 m
- To: 79 m
- Intercept Depth: 78.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78.5-79
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.54 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.8 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.54

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-500)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 78.5 m
- To: 79 m
- Intercept Depth: 78.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78.5-79
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-501)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 78.5 m
- To: 79 m
- Intercept Depth: 78.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78.5-79
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-502)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 0.5 m
- From: 78.5 m
- To: 79 m
- Intercept Depth: 78.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78.5-79
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.21 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.21

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-503)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 55
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 78.5 m
- To: 79 m
- Intercept Depth: 78.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:78.5-79
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 55 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 55

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-504)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 0.5 m
- From: 79 m
- To: 79.5 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79-79.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.15 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-505)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.69
- Grade Unit: %
- Intercept: 0.5 m
- From: 79 m
- To: 79.5 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79-79.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.69 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.3 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.69

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-506)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 79 m
- To: 79.5 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79-79.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.0 g/t·m is below.

- Negative factor: 6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-507)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 79 m
- To: 79.5 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79-79.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-508)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.34
- Grade Unit: %
- Intercept: 0.5 m
- From: 79 m
- To: 79.5 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79-79.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.34 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.34 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.34

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-509)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 78
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 79 m
- To: 79.5 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79-79.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 78 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 78

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-510)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 0.5 m
- From: 79.5 m
- To: 80 m
- Intercept Depth: 79.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79.5-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.28 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-511)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 0.5 m
- From: 79.5 m
- To: 80 m
- Intercept Depth: 79.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79.5-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.25 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.25 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.25

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-512)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 79.5 m
- To: 80 m
- Intercept Depth: 79.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79.5-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 1.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.50

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-513)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 79.5 m
- To: 80 m
- Intercept Depth: 79.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79.5-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-514)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 0.5 m
- From: 79.5 m
- To: 80 m
- Intercept Depth: 79.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79.5-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.05 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-515)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 79.5 m
- To: 80 m
- Intercept Depth: 79.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:79.5-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-516)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 82 m
- To: 82.5 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82-82.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.11 % copper is strong against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.1 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 2.11 % copper is strong on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.11

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-517)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.31
- Grade Unit: %
- Intercept: 0.5 m
- From: 82 m
- To: 82.5 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82-82.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.31 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.2 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.31

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-518)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 82 m
- To: 82.5 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82-82.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.0 g/t·m is below.

- Negative factor: 8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-519)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 82 m
- To: 82.5 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82-82.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-520)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 0.5 m
- From: 82 m
- To: 82.5 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82-82.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.05 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-521)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 52
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 82 m
- To: 82.5 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82-82.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 52 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 52

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-522)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 82.5 m
- To: 83 m
- Intercept Depth: 82.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82.5-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-523)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 82.5 m
- To: 83 m
- Intercept Depth: 82.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82.5-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.6 %·m is below.

- Negative factor: 1.1 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-524)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 82.5 m
- To: 83 m
- Intercept Depth: 82.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82.5-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.5 g/t·m is below.

- Negative factor: 1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-525)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 82.5 m
- To: 83 m
- Intercept Depth: 82.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82.5-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-526)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 82.5 m
- To: 83 m
- Intercept Depth: 82.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82.5-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-527)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 82.5 m
- To: 83 m
- Intercept Depth: 82.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:82.5-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 12 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 12

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-528)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 83.5 m
- To: 84 m
- Intercept Depth: 83.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:83.5-84
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-529)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.91
- Grade Unit: %
- Intercept: 0.5 m
- From: 83.5 m
- To: 84 m
- Intercept Depth: 83.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:83.5-84
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.91 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.5 %·m is below.

- Negative factor: 0.91 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.91

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-530)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 83.5 m
- To: 84 m
- Intercept Depth: 83.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:83.5-84
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.4 g/t·m is below.

- Negative factor: 0.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.80

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-531)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 83.5 m
- To: 84 m
- Intercept Depth: 83.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:83.5-84
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-532)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 83.5 m
- To: 84 m
- Intercept Depth: 83.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:83.5-84
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-533)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 27
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 83.5 m
- To: 84 m
- Intercept Depth: 83.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:83.5-84
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 27 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 27

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-534)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 0.5 m
- From: 84 m
- To: 84.5 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84-84.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.19 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.19

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-535)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.73
- Grade Unit: %
- Intercept: 0.5 m
- From: 84 m
- To: 84.5 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84-84.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.73 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.4 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.73

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-536)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 84 m
- To: 84.5 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84-84.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 1.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.60

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-537)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 84 m
- To: 84.5 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84-84.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-538)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 0.5 m
- From: 84 m
- To: 84.5 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84-84.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.05 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-539)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 84
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 84 m
- To: 84.5 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84-84.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 84 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 84

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-540)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.76 m
- From: 84.5 m
- To: 85.26 m
- Intercept Depth: 84.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84.5-85.26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.3 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.30

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-541)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.92
- Grade Unit: %
- Intercept: 0.76 m
- From: 84.5 m
- To: 85.26 m
- Intercept Depth: 84.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84.5-85.26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.92 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 1.5 %·m is below.

- Negative factor: 1.92 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.92

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-542)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 0.76 m
- From: 84.5 m
- To: 85.26 m
- Intercept Depth: 84.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84.5-85.26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.5 g/t·m is below.

- Negative factor: 2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-543)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.76 m
- From: 84.5 m
- To: 85.26 m
- Intercept Depth: 84.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84.5-85.26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-544)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.76 m
- From: 84.5 m
- To: 85.26 m
- Intercept Depth: 84.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84.5-85.26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-545)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 30
- Grade Unit: ppm
- Intercept: 0.76 m
- From: 84.5 m
- To: 85.26 m
- Intercept Depth: 84.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:84.5-85.26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 30 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 30

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-546)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.31
- Grade Unit: %
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.31 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.31 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.31

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-547)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-548)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.6
- Grade Unit: g/t
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.6 g/t·m is below.

- Negative factor: 1.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.60

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-549)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-550)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-551)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-552)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.58
- Grade Unit: %
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.58 % copper is strong against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.58 % copper is strong on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.58

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-553)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.61
- Grade Unit: %
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.61 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.3 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.61

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-554)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.5 g/t·m is below.

- Negative factor: 7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-555)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-556)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-557)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 44
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 44 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 44

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-558)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.83
- Grade Unit: %
- Intercept: 0.75 m
- From: 91.25 m
- To: 92 m
- Intercept Depth: 91.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:91.25-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.83 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.83

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-559)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 17.08
- Grade Unit: %
- Intercept: 0.75 m
- From: 91.25 m
- To: 92 m
- Intercept Depth: 91.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:91.25-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 17.08 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 12.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 17.08 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 17.08

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-560)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.3
- Grade Unit: g/t
- Intercept: 0.75 m
- From: 91.25 m
- To: 92 m
- Intercept Depth: 91.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:91.25-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.0 g/t·m is below.

- Negative factor: 5.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.30

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-561)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.75 m
- From: 91.25 m
- To: 92 m
- Intercept Depth: 91.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:91.25-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-562)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.75 m
- From: 91.25 m
- To: 92 m
- Intercept Depth: 91.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:91.25-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-563)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 76
- Grade Unit: ppm
- Intercept: 0.75 m
- From: 91.25 m
- To: 92 m
- Intercept Depth: 91.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:91.25-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 76 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 76

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-564)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- From: 92 m
- To: 93 m
- Intercept Depth: 92 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:92-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-565)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.65
- Grade Unit: %
- Intercept: 1 m
- From: 92 m
- To: 93 m
- Intercept Depth: 92 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:92-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.65 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 1.6 %·m is below.

- Negative factor: 1.65 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.65

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-566)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: g/t
- Intercept: 1 m
- From: 92 m
- To: 93 m
- Intercept Depth: 92 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:92-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.0 g/t·m is below.

- Negative factor: 6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.00

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-567)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 92 m
- To: 93 m
- Intercept Depth: 92 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:92-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-568)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 1 m
- From: 92 m
- To: 93 m
- Intercept Depth: 92 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:92-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.23 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.23

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-569)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 1 m
- From: 92 m
- To: 93 m
- Intercept Depth: 92 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:92-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-570)

Rush target · copper

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 95 m
- To: 96 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:95-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-571)

Rush target · zinc

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 1 m
- From: 95 m
- To: 96 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:95-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-572)

Rush target · silver

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.8
- Grade Unit: g/t
- Intercept: 1 m
- From: 95 m
- To: 96 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:95-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 0.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.80

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-573)

Rush target · gold

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 95 m
- To: 96 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:95-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-574)

Rush target · lead

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 1 m
- From: 95 m
- To: 96 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:95-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.09 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-575)

Rush target · cobalt

#### Identity

- Hole ID: Rush-002
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10
- Grade Unit: ppm
- Intercept: 1 m
- From: 95 m
- To: 96 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-002:95-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 10 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 10

Context: Rush-002

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-576)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 1 m
- From: 47 m
- To: 48 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:47-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.25 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.25 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.25

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-577)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 1 m
- From: 47 m
- To: 48 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:47-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.06 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-578)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16.1
- Grade Unit: g/t
- Intercept: 1 m
- From: 47 m
- To: 48 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:47-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 16.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 16.1 g/t·m is below.

- Negative factor: 16.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 16.10

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-579)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 1 m
- From: 47 m
- To: 48 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:47-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-580)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.48
- Grade Unit: %
- Intercept: 1 m
- From: 47 m
- To: 48 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:47-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.48 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.5 %·m is below.

- Negative factor: 0.48 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.48

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-581)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 14
- Grade Unit: ppm
- Intercept: 1 m
- From: 47 m
- To: 48 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:47-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 14 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 14

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-582)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 1 m
- From: 48 m
- To: 49 m
- Intercept Depth: 48 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:48-49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-583)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 48 m
- To: 49 m
- Intercept Depth: 48 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:48-49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-584)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13.4
- Grade Unit: g/t
- Intercept: 1 m
- From: 48 m
- To: 49 m
- Intercept Depth: 48 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:48-49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 13.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 13.4 g/t·m is below.

- Negative factor: 13.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.40

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-585)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 48 m
- To: 49 m
- Intercept Depth: 48 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:48-49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-586)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.47
- Grade Unit: %
- Intercept: 1 m
- From: 48 m
- To: 49 m
- Intercept Depth: 48 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:48-49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.47 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.5 %·m is below.

- Negative factor: 0.47 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.47

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-587)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 1 m
- From: 48 m
- To: 49 m
- Intercept Depth: 48 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:48-49
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-588)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.22 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.22

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-589)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-590)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16.2
- Grade Unit: g/t
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 16.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 16.2 g/t·m is below.

- Negative factor: 16.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 16.20

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-591)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-592)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.47
- Grade Unit: %
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.47 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.5 %·m is below.

- Negative factor: 0.47 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.47

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-593)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 14
- Grade Unit: ppm
- Intercept: 1 m
- From: 49 m
- To: 50 m
- Intercept Depth: 49 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:49-50
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 14 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 14

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-594)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-595)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-596)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.7
- Grade Unit: g/t
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.7 g/t·m is below.

- Negative factor: 6.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.70

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-597)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-598)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.37
- Grade Unit: %
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.37 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.4 %·m is below.

- Negative factor: 0.37 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.37

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-599)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 21
- Grade Unit: ppm
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 21 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 21

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-600)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 0.69 m
- From: 64 m
- To: 64.69 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64-64.69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-601)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.49
- Grade Unit: %
- Intercept: 0.69 m
- From: 64 m
- To: 64.69 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64-64.69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.49 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.49 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.49

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-602)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.6
- Grade Unit: g/t
- Intercept: 0.69 m
- From: 64 m
- To: 64.69 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64-64.69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.4 g/t·m is below.

- Negative factor: 0.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.60

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-603)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.69 m
- From: 64 m
- To: 64.69 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64-64.69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-604)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.69 m
- From: 64 m
- To: 64.69 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64-64.69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-605)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 0.69 m
- From: 64 m
- To: 64.69 m
- Intercept Depth: 64 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64-64.69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-606)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.19
- Grade Unit: %
- Intercept: 0.31 m
- From: 64.69 m
- To: 65 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64.69-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.19 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.4 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.19

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-607)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8.67
- Grade Unit: %
- Intercept: 0.31 m
- From: 64.69 m
- To: 65 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64.69-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8.67 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 2.7 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.67

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-608)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.4
- Grade Unit: g/t
- Intercept: 0.31 m
- From: 64.69 m
- To: 65 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64.69-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.3 g/t·m is below.

- Negative factor: 7.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.40

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-609)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: g/t
- Intercept: 0.31 m
- From: 64.69 m
- To: 65 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64.69-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.13 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-610)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.31 m
- From: 64.69 m
- To: 65 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64.69-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-611)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 152
- Grade Unit: ppm
- Intercept: 0.31 m
- From: 64.69 m
- To: 65 m
- Intercept Depth: 64.69 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:64.69-65
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 152 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 152

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-612)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.39
- Grade Unit: %
- Intercept: 0.5 m
- From: 65 m
- To: 65.5 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:65-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.39 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.7 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.39

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-613)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 65 m
- To: 65.5 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:65-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.2 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 5.1 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 10.2 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.20

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-614)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 65 m
- To: 65.5 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:65-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.0 g/t·m is below.

- Negative factor: 8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.00

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-615)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 65 m
- To: 65.5 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:65-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-616)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 65 m
- To: 65.5 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:65-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-617)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 138
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 65 m
- To: 65.5 m
- Intercept Depth: 65 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:65-65.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 138 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 138

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-618)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 1 m
- From: 76 m
- To: 77 m
- Intercept Depth: 76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:76-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.15 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-619)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 1 m
- From: 76 m
- To: 77 m
- Intercept Depth: 76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:76-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.17 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-620)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.7
- Grade Unit: g/t
- Intercept: 1 m
- From: 76 m
- To: 77 m
- Intercept Depth: 76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:76-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.7 g/t·m is below.

- Negative factor: 1.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.70

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-621)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 76 m
- To: 77 m
- Intercept Depth: 76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:76-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-622)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 1 m
- From: 76 m
- To: 77 m
- Intercept Depth: 76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:76-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.08 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-623)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12
- Grade Unit: ppm
- Intercept: 1 m
- From: 76 m
- To: 77 m
- Intercept Depth: 76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:76-77
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 12 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 12

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-624)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- From: 84 m
- To: 85 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:84-85
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-625)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 1 m
- From: 84 m
- To: 85 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:84-85
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.28 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-626)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 1 m
- From: 84 m
- To: 85 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:84-85
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.9 g/t·m is below.

- Negative factor: 0.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.90

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-627)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 1 m
- From: 84 m
- To: 85 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:84-85
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-628)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 1 m
- From: 84 m
- To: 85 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:84-85
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.15 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-629)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 1 m
- From: 84 m
- To: 85 m
- Intercept Depth: 84 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:84-85
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-630)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.43
- Grade Unit: %
- Intercept: 1.24 m
- From: 87.76 m
- To: 89 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:87.76-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.43 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.5 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.43

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-631)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.5
- Grade Unit: %
- Intercept: 1.24 m
- From: 87.76 m
- To: 89 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:87.76-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.6 %·m is below.

- Negative factor: 0.5 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.50

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-632)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.7
- Grade Unit: g/t
- Intercept: 1.24 m
- From: 87.76 m
- To: 89 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:87.76-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.8 g/t·m is below.

- Negative factor: 4.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.70

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-633)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1.24 m
- From: 87.76 m
- To: 89 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:87.76-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-634)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 1.24 m
- From: 87.76 m
- To: 89 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:87.76-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.15 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-635)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 29
- Grade Unit: ppm
- Intercept: 1.24 m
- From: 87.76 m
- To: 89 m
- Intercept Depth: 87.76 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:87.76-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 29 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 29

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-636)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.18 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.18

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-637)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.32
- Grade Unit: %
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.32 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 1.3 %·m is below.

- Negative factor: 1.32 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.32

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-638)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.4
- Grade Unit: g/t
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 1.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.40

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-639)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-640)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.08 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-641)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16
- Grade Unit: ppm
- Intercept: 1 m
- From: 89 m
- To: 90 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:89-90
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 16 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 16

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-642)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.28 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-643)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.56
- Grade Unit: %
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.56 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.8 %·m is below.

- Negative factor: 1.56 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.56

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-644)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 1.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.20

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-645)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-646)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-647)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 51
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 90 m
- To: 90.5 m
- Intercept Depth: 90 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90-90.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 51 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 51

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-648)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.47
- Grade Unit: %
- Intercept: 0.5 m
- From: 90.5 m
- To: 91 m
- Intercept Depth: 90.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90.5-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.47 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.47

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-649)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.28
- Grade Unit: %
- Intercept: 0.5 m
- From: 90.5 m
- To: 91 m
- Intercept Depth: 90.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90.5-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.28 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 1.1 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.28

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-650)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 90.5 m
- To: 91 m
- Intercept Depth: 90.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90.5-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.5 g/t·m is below.

- Negative factor: 7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.00

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-651)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 90.5 m
- To: 91 m
- Intercept Depth: 90.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90.5-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-652)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 0.5 m
- From: 90.5 m
- To: 91 m
- Intercept Depth: 90.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90.5-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.16 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-653)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 38
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 90.5 m
- To: 91 m
- Intercept Depth: 90.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:90.5-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 38 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 38

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-654)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 0.5 m
- From: 91 m
- To: 91.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91-91.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.23 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.23

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-655)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.89
- Grade Unit: %
- Intercept: 0.5 m
- From: 91 m
- To: 91.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91-91.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.89 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.4 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.89

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-656)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 91 m
- To: 91.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91-91.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.0 g/t·m is below.

- Negative factor: 2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.00

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-657)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 91 m
- To: 91.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91-91.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-658)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 91 m
- To: 91.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91-91.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-659)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 71
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 91 m
- To: 91.5 m
- Intercept Depth: 91 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91-91.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 71 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 71

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-660)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.87
- Grade Unit: %
- Intercept: 0.5 m
- From: 91.5 m
- To: 92 m
- Intercept Depth: 91.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91.5-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.87 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.4 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.87

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-661)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.98
- Grade Unit: %
- Intercept: 0.5 m
- From: 91.5 m
- To: 92 m
- Intercept Depth: 91.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91.5-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.98 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.5 %·m is below.

- Negative factor: 0.98 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.98

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-662)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 91.5 m
- To: 92 m
- Intercept Depth: 91.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91.5-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.8 g/t·m is below.

- Negative factor: 3.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.50

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-663)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 91.5 m
- To: 92 m
- Intercept Depth: 91.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91.5-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-664)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.5 m
- From: 91.5 m
- To: 92 m
- Intercept Depth: 91.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91.5-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-665)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 91.5 m
- To: 92 m
- Intercept Depth: 91.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:91.5-92
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-666)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 92.5 m
- To: 93 m
- Intercept Depth: 92.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:92.5-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-667)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.38
- Grade Unit: %
- Intercept: 0.5 m
- From: 92.5 m
- To: 93 m
- Intercept Depth: 92.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:92.5-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.38 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.7 %·m is below.

- Negative factor: 1.38 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.38

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-668)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 92.5 m
- To: 93 m
- Intercept Depth: 92.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:92.5-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 1.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.60

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-669)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 92.5 m
- To: 93 m
- Intercept Depth: 92.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:92.5-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-670)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 92.5 m
- To: 93 m
- Intercept Depth: 92.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:92.5-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-671)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 29
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 92.5 m
- To: 93 m
- Intercept Depth: 92.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:92.5-93
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 29 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 29

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-672)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.29 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.29 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.29

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-673)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-674)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 27.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 27.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 13.8 g/t·m is below.

- Negative factor: 27.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 27.50

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-675)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-676)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.73
- Grade Unit: %
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.73 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.4 %·m is below.

- Negative factor: 0.73 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.73

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-677)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-678)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-679)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.07 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-680)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 20.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 20.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 10.1 g/t·m is below.

- Negative factor: 20.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 20.20

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-681)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-682)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.81
- Grade Unit: %
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.81 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.4 %·m is below.

- Negative factor: 0.81 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.81

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-683)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-684)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.24
- Grade Unit: %
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.24 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.24

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-685)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-686)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.00

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-687)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-688)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.19 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.19

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-689)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-690)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.19 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.19

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-691)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-692)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.1 g/t·m is below.

- Negative factor: 2.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.10

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-693)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-694)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-695)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 118
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 118 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 118

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-696)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 0.5 m
- From: 97.5 m
- To: 98 m
- Intercept Depth: 97.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:97.5-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-697)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.61
- Grade Unit: %
- Intercept: 0.5 m
- From: 97.5 m
- To: 98 m
- Intercept Depth: 97.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:97.5-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.61 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.61 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.61

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-698)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 97.5 m
- To: 98 m
- Intercept Depth: 97.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:97.5-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 1.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.20

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-699)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 97.5 m
- To: 98 m
- Intercept Depth: 97.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:97.5-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-700)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 97.5 m
- To: 98 m
- Intercept Depth: 97.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:97.5-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-701)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 97.5 m
- To: 98 m
- Intercept Depth: 97.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:97.5-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 8 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 8

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-702)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 0.5 m
- From: 98 m
- To: 98.5 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98-98.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.21 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.21

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-703)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.99
- Grade Unit: %
- Intercept: 0.5 m
- From: 98 m
- To: 98.5 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98-98.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.99 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.5 %·m is below.

- Negative factor: 0.99 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.99

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-704)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 98 m
- To: 98.5 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98-98.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 2.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.80

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-705)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 98 m
- To: 98.5 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98-98.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-706)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 98 m
- To: 98.5 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98-98.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-707)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 98 m
- To: 98.5 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98-98.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 9 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 9

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-708)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 0.5 m
- From: 98.5 m
- To: 99 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98.5-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.22 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.22

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-709)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1
- Grade Unit: %
- Intercept: 0.5 m
- From: 98.5 m
- To: 99 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98.5-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.5 %·m is below.

- Negative factor: 1 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.00

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-710)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 98.5 m
- To: 99 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98.5-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.6 g/t·m is below.

- Negative factor: 3.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.30

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-711)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 98.5 m
- To: 99 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98.5-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-712)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 0.5 m
- From: 98.5 m
- To: 99 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98.5-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.15 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-713)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 98.5 m
- To: 99 m
- Intercept Depth: 98.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:98.5-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 7 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 7

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-714)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99-99.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-715)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 0.5 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99-99.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.17 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-716)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99-99.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.5 g/t·m is below.

- Negative factor: 4.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.90

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-717)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99-99.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-718)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 0.5 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99-99.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.28 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-719)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 99 m
- To: 99.5 m
- Intercept Depth: 99 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99-99.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-720)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.24
- Grade Unit: %
- Intercept: 0.5 m
- From: 99.5 m
- To: 100 m
- Intercept Depth: 99.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99.5-100
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.24 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.24

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-721)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 99.5 m
- To: 100 m
- Intercept Depth: 99.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99.5-100
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-722)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 99.5 m
- To: 100 m
- Intercept Depth: 99.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99.5-100
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.1 g/t·m is below.

- Negative factor: 4.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.20

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-723)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 99.5 m
- To: 100 m
- Intercept Depth: 99.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99.5-100
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-724)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.27
- Grade Unit: %
- Intercept: 0.5 m
- From: 99.5 m
- To: 100 m
- Intercept Depth: 99.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99.5-100
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.27 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.27

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-725)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 14
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 99.5 m
- To: 100 m
- Intercept Depth: 99.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:99.5-100
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 14 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 14

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-726)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 0.5 m
- From: 100 m
- To: 100.5 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100-100.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.18 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.18

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-727)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.18
- Grade Unit: %
- Intercept: 0.5 m
- From: 100 m
- To: 100.5 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100-100.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.18 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 2.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.18

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-728)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 100 m
- To: 100.5 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100-100.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 13 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.5 g/t·m is below.

- Negative factor: 13 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.00

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-729)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 100 m
- To: 100.5 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100-100.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-730)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 100 m
- To: 100.5 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100-100.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.01 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 0.5 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-731)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 100 m
- To: 100.5 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100-100.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 16 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 16

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-732)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 0.5 m
- From: 100.5 m
- To: 101 m
- Intercept Depth: 100.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100.5-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.22 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.22

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-733)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8.62
- Grade Unit: %
- Intercept: 0.5 m
- From: 100.5 m
- To: 101 m
- Intercept Depth: 100.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100.5-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8.62 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.3 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.62

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-734)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 100.5 m
- To: 101 m
- Intercept Depth: 100.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100.5-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.9 g/t·m is below.

- Negative factor: 5.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.80

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-735)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 100.5 m
- To: 101 m
- Intercept Depth: 100.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100.5-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-736)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.57
- Grade Unit: %
- Intercept: 0.5 m
- From: 100.5 m
- To: 101 m
- Intercept Depth: 100.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100.5-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.57 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.57 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.57

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-737)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 89
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 100.5 m
- To: 101 m
- Intercept Depth: 100.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:100.5-101
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 89 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 89

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-738)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 1 m
- From: 102 m
- To: 103 m
- Intercept Depth: 102 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:102-103
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.22 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.22

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-739)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 102 m
- To: 103 m
- Intercept Depth: 102 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:102-103
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-740)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18.8
- Grade Unit: g/t
- Intercept: 1 m
- From: 102 m
- To: 103 m
- Intercept Depth: 102 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:102-103
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 18.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 18.8 g/t·m is below.

- Negative factor: 18.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 18.80

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-741)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 102 m
- To: 103 m
- Intercept Depth: 102 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:102-103
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-742)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.97
- Grade Unit: %
- Intercept: 1 m
- From: 102 m
- To: 103 m
- Intercept Depth: 102 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:102-103
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.97 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 1.0 %·m is below.

- Negative factor: 0.97 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.97

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-743)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 1 m
- From: 102 m
- To: 103 m
- Intercept Depth: 102 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:102-103
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-744)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 1 m
- From: 103 m
- To: 104 m
- Intercept Depth: 103 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:103-104
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.16 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-745)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 1 m
- From: 103 m
- To: 104 m
- Intercept Depth: 103 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:103-104
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-746)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.8
- Grade Unit: g/t
- Intercept: 1 m
- From: 103 m
- To: 104 m
- Intercept Depth: 103 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:103-104
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 10.8 g/t·m is below.

- Negative factor: 10.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.80

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-747)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 103 m
- To: 104 m
- Intercept Depth: 103 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:103-104
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-748)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.99
- Grade Unit: %
- Intercept: 1 m
- From: 103 m
- To: 104 m
- Intercept Depth: 103 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:103-104
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.99 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 1.0 %·m is below.

- Negative factor: 0.99 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.99

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-749)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12
- Grade Unit: ppm
- Intercept: 1 m
- From: 103 m
- To: 104 m
- Intercept Depth: 103 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:103-104
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 12 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 12

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-750)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- From: 104 m
- To: 105 m
- Intercept Depth: 104 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:104-105
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-751)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 1 m
- From: 104 m
- To: 105 m
- Intercept Depth: 104 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:104-105
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.06 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-752)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.5
- Grade Unit: g/t
- Intercept: 1 m
- From: 104 m
- To: 105 m
- Intercept Depth: 104 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:104-105
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 10.5 g/t·m is below.

- Negative factor: 10.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.50

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-753)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 104 m
- To: 105 m
- Intercept Depth: 104 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:104-105
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-754)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.57
- Grade Unit: %
- Intercept: 1 m
- From: 104 m
- To: 105 m
- Intercept Depth: 104 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:104-105
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.57 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.6 %·m is below.

- Negative factor: 0.57 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.57

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-755)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9
- Grade Unit: ppm
- Intercept: 1 m
- From: 104 m
- To: 105 m
- Intercept Depth: 104 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:104-105
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 9 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 9

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-756)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 1 m
- From: 105 m
- To: 106 m
- Intercept Depth: 105 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:105-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.32 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.32

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-757)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 1 m
- From: 105 m
- To: 106 m
- Intercept Depth: 105 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:105-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.06 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-758)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 35.3
- Grade Unit: g/t
- Intercept: 1 m
- From: 105 m
- To: 106 m
- Intercept Depth: 105 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:105-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 35.3 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 35.3 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 35.30

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-759)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 1 m
- From: 105 m
- To: 106 m
- Intercept Depth: 105 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:105-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-760)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.33
- Grade Unit: %
- Intercept: 1 m
- From: 105 m
- To: 106 m
- Intercept Depth: 105 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:105-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.33 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 1.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.33

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-761)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7
- Grade Unit: ppm
- Intercept: 1 m
- From: 105 m
- To: 106 m
- Intercept Depth: 105 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:105-106
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 7 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 7

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-762)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 1 m
- From: 107 m
- To: 108 m
- Intercept Depth: 107 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:107-108
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-763)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.81
- Grade Unit: %
- Intercept: 1 m
- From: 107 m
- To: 108 m
- Intercept Depth: 107 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:107-108
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.81 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.8 %·m is below.

- Negative factor: 0.81 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.81

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-764)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 1 m
- From: 107 m
- To: 108 m
- Intercept Depth: 107 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:107-108
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.3 g/t·m is below.

- Negative factor: 1.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.30

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-765)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 107 m
- To: 108 m
- Intercept Depth: 107 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:107-108
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-766)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 1 m
- From: 107 m
- To: 108 m
- Intercept Depth: 107 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:107-108
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.23 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.23

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-767)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 17
- Grade Unit: ppm
- Intercept: 1 m
- From: 107 m
- To: 108 m
- Intercept Depth: 107 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:107-108
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 17 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 17

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-768)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 1 m
- From: 108 m
- To: 109 m
- Intercept Depth: 108 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:108-109
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.17 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-769)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 1 m
- From: 108 m
- To: 109 m
- Intercept Depth: 108 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:108-109
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.26 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.26 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.26

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-770)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 14.1
- Grade Unit: g/t
- Intercept: 1 m
- From: 108 m
- To: 109 m
- Intercept Depth: 108 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:108-109
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 14.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 14.1 g/t·m is below.

- Negative factor: 14.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 14.10

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-771)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 1 m
- From: 108 m
- To: 109 m
- Intercept Depth: 108 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:108-109
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-772)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.43
- Grade Unit: %
- Intercept: 1 m
- From: 108 m
- To: 109 m
- Intercept Depth: 108 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:108-109
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.43 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.4 %·m is below.

- Negative factor: 0.43 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.43

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-773)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9
- Grade Unit: ppm
- Intercept: 1 m
- From: 108 m
- To: 109 m
- Intercept Depth: 108 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:108-109
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 9 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 9

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-774)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- From: 110 m
- To: 111 m
- Intercept Depth: 110 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:110-111
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-775)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.46
- Grade Unit: %
- Intercept: 1 m
- From: 110 m
- To: 111 m
- Intercept Depth: 110 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:110-111
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.46 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 1.5 %·m is below.

- Negative factor: 1.46 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.46

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-776)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.6
- Grade Unit: g/t
- Intercept: 1 m
- From: 110 m
- To: 111 m
- Intercept Depth: 110 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:110-111
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.6 g/t·m is below.

- Negative factor: 1.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.60

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-777)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 1 m
- From: 110 m
- To: 111 m
- Intercept Depth: 110 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:110-111
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-778)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.31
- Grade Unit: %
- Intercept: 1 m
- From: 110 m
- To: 111 m
- Intercept Depth: 110 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:110-111
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.31 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.31 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.31

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-779)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9
- Grade Unit: ppm
- Intercept: 1 m
- From: 110 m
- To: 111 m
- Intercept Depth: 110 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:110-111
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 9 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 9

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-780)

Rush target · copper

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 1 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:120-121
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.22 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.22

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-781)

Rush target · zinc

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:120-121
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-782)

Rush target · silver

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12.7
- Grade Unit: g/t
- Intercept: 1 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:120-121
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 12.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 12.7 g/t·m is below.

- Negative factor: 12.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 12.70

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-783)

Rush target · gold

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:120-121
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-784)

Rush target · lead

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.56
- Grade Unit: %
- Intercept: 1 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:120-121
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.56 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.6 %·m is below.

- Negative factor: 0.56 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.56

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-785)

Rush target · cobalt

#### Identity

- Hole ID: Rush-003
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12
- Grade Unit: ppm
- Intercept: 1 m
- From: 120 m
- To: 121 m
- Intercept Depth: 120 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-003:120-121
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 12 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 12

Context: Rush-003

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-786)

Rush target · copper

#### Identity

- Hole ID: Rush-004
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-004:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.17 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-004

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-787)

Rush target · zinc

#### Identity

- Hole ID: Rush-004
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-004:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-004

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-788)

Rush target · silver

#### Identity

- Hole ID: Rush-004
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.8
- Grade Unit: g/t
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-004:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 0.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.80

Context: Rush-004

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-789)

Rush target · gold

#### Identity

- Hole ID: Rush-004
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-004:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-004

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-790)

Rush target · lead

#### Identity

- Hole ID: Rush-004
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-004:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-004

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-791)

Rush target · cobalt

#### Identity

- Hole ID: Rush-004
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 17
- Grade Unit: ppm
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-004:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 17 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 17

Context: Rush-004

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-792)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 1 m
- From: 22 m
- To: 23 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:22-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.18 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.18

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-793)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 22 m
- To: 23 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:22-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-794)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.3
- Grade Unit: g/t
- Intercept: 1 m
- From: 22 m
- To: 23 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:22-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 7.3 g/t·m is below.

- Negative factor: 7.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.30

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-795)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 22 m
- To: 23 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:22-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-796)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 22 m
- To: 23 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:22-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-797)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 1 m
- From: 22 m
- To: 23 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:22-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-798)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-799)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-800)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.2 g/t·m is below.

- Negative factor: 1.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.20

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-801)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-802)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-803)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 1 m
- From: 41 m
- To: 42 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:41-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-804)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 1 m
- From: 51 m
- To: 52 m
- Intercept Depth: 51 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:51-52
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.16 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-805)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 1 m
- From: 51 m
- To: 52 m
- Intercept Depth: 51 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:51-52
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-806)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 1 m
- From: 51 m
- To: 52 m
- Intercept Depth: 51 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:51-52
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.3 g/t·m is below.

- Negative factor: 1.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.30

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-807)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 51 m
- To: 52 m
- Intercept Depth: 51 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:51-52
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-808)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 51 m
- To: 52 m
- Intercept Depth: 51 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:51-52
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-809)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 1 m
- From: 51 m
- To: 52 m
- Intercept Depth: 51 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:51-52
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-810)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 52 m
- To: 53 m
- Intercept Depth: 52 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:52-53
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-811)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 52 m
- To: 53 m
- Intercept Depth: 52 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:52-53
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-812)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.4
- Grade Unit: g/t
- Intercept: 1 m
- From: 52 m
- To: 53 m
- Intercept Depth: 52 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:52-53
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 1.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.40

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-813)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 52 m
- To: 53 m
- Intercept Depth: 52 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:52-53
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-814)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 52 m
- To: 53 m
- Intercept Depth: 52 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:52-53
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-815)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12
- Grade Unit: ppm
- Intercept: 1 m
- From: 52 m
- To: 53 m
- Intercept Depth: 52 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:52-53
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 12 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 12

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-816)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.16 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-817)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.06 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-818)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.6
- Grade Unit: g/t
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.6 g/t·m is below.

- Negative factor: 2.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.60

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-819)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-820)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-821)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 21
- Grade Unit: ppm
- Intercept: 1 m
- From: 62 m
- To: 63 m
- Intercept Depth: 62 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:62-63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 21 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 21

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-822)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.34
- Grade Unit: %
- Intercept: 0.5 m
- From: 65.5 m
- To: 66 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:65.5-66
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.34 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.34 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.34

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-823)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 0.5 m
- From: 65.5 m
- To: 66 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:65.5-66
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-824)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 65.5 m
- To: 66 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:65.5-66
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 2.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.90

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-825)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 65.5 m
- To: 66 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:65.5-66
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-826)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 65.5 m
- To: 66 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:65.5-66
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-827)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 29
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 65.5 m
- To: 66 m
- Intercept Depth: 65.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:65.5-66
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 29 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 29

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-828)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.51
- Grade Unit: %
- Intercept: 0.5 m
- From: 66 m
- To: 66.5 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66-66.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.51 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.51

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-829)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 0.5 m
- From: 66 m
- To: 66.5 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66-66.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.05 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-830)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 66 m
- To: 66.5 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66-66.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.7 g/t·m is below.

- Negative factor: 5.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.40

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-831)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 66 m
- To: 66.5 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66-66.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-832)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 66 m
- To: 66.5 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66-66.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-833)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 33
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 66 m
- To: 66.5 m
- Intercept Depth: 66 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66-66.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 33 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 33

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-834)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 0.5 m
- From: 66.5 m
- To: 67 m
- Intercept Depth: 66.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66.5-67
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.29 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.29 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.29

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-835)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.24
- Grade Unit: %
- Intercept: 0.5 m
- From: 66.5 m
- To: 67 m
- Intercept Depth: 66.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66.5-67
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.24 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.24

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-836)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 66.5 m
- To: 67 m
- Intercept Depth: 66.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66.5-67
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.1 g/t·m is below.

- Negative factor: 2.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.10

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-837)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 66.5 m
- To: 67 m
- Intercept Depth: 66.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66.5-67
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-838)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 66.5 m
- To: 67 m
- Intercept Depth: 66.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66.5-67
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-839)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 66.5 m
- To: 67 m
- Intercept Depth: 66.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:66.5-67
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 8 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 8

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-840)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 0.5 m
- From: 68 m
- To: 68.5 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68-68.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.28 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-841)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.24
- Grade Unit: %
- Intercept: 0.5 m
- From: 68 m
- To: 68.5 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68-68.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.24 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.24

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-842)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 68 m
- To: 68.5 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68-68.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.1 g/t·m is below.

- Negative factor: 2.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.30

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-843)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 68 m
- To: 68.5 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68-68.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-844)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 68 m
- To: 68.5 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68-68.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-845)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 68 m
- To: 68.5 m
- Intercept Depth: 68 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68-68.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 6 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 6

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-846)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.36
- Grade Unit: %
- Intercept: 0.5 m
- From: 68.5 m
- To: 69 m
- Intercept Depth: 68.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68.5-69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.36 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.36 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.36

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-847)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 68.5 m
- To: 69 m
- Intercept Depth: 68.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68.5-69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-848)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 68.5 m
- To: 69 m
- Intercept Depth: 68.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68.5-69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.9 g/t·m is below.

- Negative factor: 5.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.80

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-849)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 68.5 m
- To: 69 m
- Intercept Depth: 68.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68.5-69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-850)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 68.5 m
- To: 69 m
- Intercept Depth: 68.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68.5-69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-851)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 68.5 m
- To: 69 m
- Intercept Depth: 68.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:68.5-69
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-852)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-853)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-854)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-855)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-856)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 70 m
- To: 70.5 m
- Intercept Depth: 70 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70-70.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 7 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 7

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-857)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.43
- Grade Unit: %
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.43 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.43

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-858)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-859)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.3 g/t·m is below.

- Negative factor: 2.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.60

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-860)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-861)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-862)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 70.5 m
- To: 71 m
- Intercept Depth: 70.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:70.5-71
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-863)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 0.7 m
- From: 87.5 m
- To: 88.2 m
- Intercept Depth: 87.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:87.5-88.2
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.15 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-864)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 0.7 m
- From: 87.5 m
- To: 88.2 m
- Intercept Depth: 87.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:87.5-88.2
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.21 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.21

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-865)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 87.5 m
- To: 88.2 m
- Intercept Depth: 87.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:87.5-88.2
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 0.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.90

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-866)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.7 m
- From: 87.5 m
- To: 88.2 m
- Intercept Depth: 87.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:87.5-88.2
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-867)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.7 m
- From: 87.5 m
- To: 88.2 m
- Intercept Depth: 87.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:87.5-88.2
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-868)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12
- Grade Unit: ppm
- Intercept: 0.7 m
- From: 87.5 m
- To: 88.2 m
- Intercept Depth: 87.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:87.5-88.2
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 12 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 12

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-869)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.73
- Grade Unit: %
- Intercept: 0.8 m
- From: 88.2 m
- To: 89 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:88.2-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.73 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.73

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-870)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.18
- Grade Unit: %
- Intercept: 0.8 m
- From: 88.2 m
- To: 89 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:88.2-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.18 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 8.1 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 10.18 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.18

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-871)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 88.2 m
- To: 89 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:88.2-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.2 g/t·m is below.

- Negative factor: 4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-872)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.8 m
- From: 88.2 m
- To: 89 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:88.2-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-873)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.8 m
- From: 88.2 m
- To: 89 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:88.2-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-874)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 91
- Grade Unit: ppm
- Intercept: 0.8 m
- From: 88.2 m
- To: 89 m
- Intercept Depth: 88.2 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:88.2-89
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 91 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 91

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-875)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.57
- Grade Unit: %
- Intercept: 0.5 m
- From: 89 m
- To: 89.5 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89-89.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.57 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.57

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-876)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.51
- Grade Unit: %
- Intercept: 0.5 m
- From: 89 m
- To: 89.5 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89-89.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.51 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.8 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.51

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-877)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 89 m
- To: 89.5 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89-89.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.5 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-878)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 89 m
- To: 89.5 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89-89.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-879)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 89 m
- To: 89.5 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89-89.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-880)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 105
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 89 m
- To: 89.5 m
- Intercept Depth: 89 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89-89.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 105 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 105

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-881)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.84
- Grade Unit: %
- Intercept: 0.75 m
- From: 89.5 m
- To: 90.25 m
- Intercept Depth: 89.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89.5-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.84 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.84

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-882)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.19
- Grade Unit: %
- Intercept: 0.75 m
- From: 89.5 m
- To: 90.25 m
- Intercept Depth: 89.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89.5-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.19 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 7.6 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 10.19 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.19

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-883)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.75 m
- From: 89.5 m
- To: 90.25 m
- Intercept Depth: 89.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89.5-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.0 g/t·m is below.

- Negative factor: 4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-884)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.75 m
- From: 89.5 m
- To: 90.25 m
- Intercept Depth: 89.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89.5-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-885)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.75 m
- From: 89.5 m
- To: 90.25 m
- Intercept Depth: 89.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89.5-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-886)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 147
- Grade Unit: ppm
- Intercept: 0.75 m
- From: 89.5 m
- To: 90.25 m
- Intercept Depth: 89.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:89.5-90.25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 147 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 147

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-887)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 0.75 m
- From: 90.25 m
- To: 91 m
- Intercept Depth: 90.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:90.25-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.17 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-888)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 0.75 m
- From: 90.25 m
- To: 91 m
- Intercept Depth: 90.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:90.25-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.4 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.40

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-889)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.8
- Grade Unit: g/t
- Intercept: 0.75 m
- From: 90.25 m
- To: 91 m
- Intercept Depth: 90.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:90.25-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 0.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.80

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-890)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.75 m
- From: 90.25 m
- To: 91 m
- Intercept Depth: 90.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:90.25-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-891)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.75 m
- From: 90.25 m
- To: 91 m
- Intercept Depth: 90.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:90.25-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-892)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7
- Grade Unit: ppm
- Intercept: 0.75 m
- From: 90.25 m
- To: 91 m
- Intercept Depth: 90.25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:90.25-91
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 7 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 7

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-893)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- From: 96 m
- To: 97 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:96-97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-894)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 1 m
- From: 96 m
- To: 97 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:96-97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-895)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9
- Grade Unit: g/t
- Intercept: 1 m
- From: 96 m
- To: 97 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:96-97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 9.0 g/t·m is below.

- Negative factor: 9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-896)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 1 m
- From: 96 m
- To: 97 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:96-97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-897)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 1 m
- From: 96 m
- To: 97 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:96-97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.29 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.29 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.29

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-898)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 1 m
- From: 96 m
- To: 97 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:96-97
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-899)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.33
- Grade Unit: %
- Intercept: 1 m
- From: 97 m
- To: 98 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:97-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.33 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.33

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-900)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 1 m
- From: 97 m
- To: 98 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:97-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.07 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-901)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 40
- Grade Unit: g/t
- Intercept: 1 m
- From: 97 m
- To: 98 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:97-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 40 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 40.0 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 40.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-902)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.27
- Grade Unit: g/t
- Intercept: 1 m
- From: 97 m
- To: 98 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:97-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.3 g/t·m is below.

- Negative factor: 0.27 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.27

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-903)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.8
- Grade Unit: %
- Intercept: 1 m
- From: 97 m
- To: 98 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:97-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.8 %·m is below.

- Negative factor: 0.8 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.80

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-904)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 1 m
- From: 97 m
- To: 98 m
- Intercept Depth: 97 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:97-98
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-905)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 1 m
- From: 98 m
- To: 99 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:98-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.17 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-906)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- From: 98 m
- To: 99 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:98-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-907)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2
- Grade Unit: g/t
- Intercept: 1 m
- From: 98 m
- To: 99 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:98-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-908)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 98 m
- To: 99 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:98-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-909)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 1 m
- From: 98 m
- To: 99 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:98-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.06 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-910)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 1 m
- From: 98 m
- To: 99 m
- Intercept Depth: 98 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:98-99
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-911)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.05
- Grade Unit: %
- Intercept: 0.55 m
- From: 115.95 m
- To: 116.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:115.95-116.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.05 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.05

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-912)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.65
- Grade Unit: %
- Intercept: 0.55 m
- From: 115.95 m
- To: 116.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:115.95-116.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.65 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.2 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.65

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-913)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.8
- Grade Unit: g/t
- Intercept: 0.55 m
- From: 115.95 m
- To: 116.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:115.95-116.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.5 g/t·m is below.

- Negative factor: 2.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.80

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-914)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.55 m
- From: 115.95 m
- To: 116.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:115.95-116.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-915)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.55 m
- From: 115.95 m
- To: 116.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:115.95-116.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-916)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 105
- Grade Unit: ppm
- Intercept: 0.55 m
- From: 115.95 m
- To: 116.5 m
- Intercept Depth: 115.95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:115.95-116.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 105 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 105

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-917)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.49
- Grade Unit: %
- Intercept: 0.5 m
- From: 116.5 m
- To: 117 m
- Intercept Depth: 116.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:116.5-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.49 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.49

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-918)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13.43
- Grade Unit: %
- Intercept: 0.5 m
- From: 116.5 m
- To: 117 m
- Intercept Depth: 116.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:116.5-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 13.43 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 6.7 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 13.43 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.43

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-919)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 116.5 m
- To: 117 m
- Intercept Depth: 116.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:116.5-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.5 g/t·m is below.

- Negative factor: 7.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.10

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-920)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 116.5 m
- To: 117 m
- Intercept Depth: 116.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:116.5-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-921)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.45
- Grade Unit: %
- Intercept: 0.5 m
- From: 116.5 m
- To: 117 m
- Intercept Depth: 116.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:116.5-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.45 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.45 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.45

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-922)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 182
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 116.5 m
- To: 117 m
- Intercept Depth: 116.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:116.5-117
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 182 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 182

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-923)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 0.5 m
- From: 117 m
- To: 117.5 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117-117.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.60

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-924)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 7.93
- Grade Unit: %
- Intercept: 0.5 m
- From: 117 m
- To: 117.5 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117-117.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 7.93 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.0 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 7.93

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-925)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 117 m
- To: 117.5 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117-117.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 1.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.10

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-926)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 117 m
- To: 117.5 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117-117.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-927)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 117 m
- To: 117.5 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117-117.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-928)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 203
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 117 m
- To: 117.5 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117-117.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 203 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 203

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-929)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.22
- Grade Unit: %
- Intercept: 0.5 m
- From: 117.5 m
- To: 118 m
- Intercept Depth: 117.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117.5-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.22 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.22

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-930)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15.78
- Grade Unit: %
- Intercept: 0.5 m
- From: 117.5 m
- To: 118 m
- Intercept Depth: 117.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117.5-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 15.78 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 7.9 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 15.78 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 15.78

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-931)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 117.5 m
- To: 118 m
- Intercept Depth: 117.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117.5-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.4 g/t·m is below.

- Negative factor: 6.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.80

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-932)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 117.5 m
- To: 118 m
- Intercept Depth: 117.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117.5-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-933)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.24
- Grade Unit: %
- Intercept: 0.5 m
- From: 117.5 m
- To: 118 m
- Intercept Depth: 117.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117.5-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.24 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.24

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-934)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 165
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 117.5 m
- To: 118 m
- Intercept Depth: 117.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:117.5-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 165 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 165

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-935)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 118 m
- To: 118.5 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.11 % copper is exceptional against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.6 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 3.11 % copper is exceptional on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.11

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-936)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 17.57
- Grade Unit: %
- Intercept: 0.5 m
- From: 118 m
- To: 118.5 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 17.57 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 8.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 17.57 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 17.57

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-937)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 20
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 118 m
- To: 118.5 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 20 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 10.0 g/t·m is below.

- Negative factor: 20 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 20.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-938)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 118 m
- To: 118.5 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.1 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-939)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.64
- Grade Unit: %
- Intercept: 0.5 m
- From: 118 m
- To: 118.5 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.64 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.64 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.64

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-940)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 126
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 118 m
- To: 118.5 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118-118.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 126 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 126

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-941)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 0.5 m
- From: 118.5 m
- To: 119 m
- Intercept Depth: 118.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118.5-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.17 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-942)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.3
- Grade Unit: %
- Intercept: 0.5 m
- From: 118.5 m
- To: 119 m
- Intercept Depth: 118.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118.5-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.3 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 1.6 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.30

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-943)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 118.5 m
- To: 119 m
- Intercept Depth: 118.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118.5-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.3 g/t·m is below.

- Negative factor: 2.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.50

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-944)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 118.5 m
- To: 119 m
- Intercept Depth: 118.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118.5-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-945)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 0.5 m
- From: 118.5 m
- To: 119 m
- Intercept Depth: 118.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118.5-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-946)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 40
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 118.5 m
- To: 119 m
- Intercept Depth: 118.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:118.5-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 40 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 40

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-947)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 1 m
- From: 121 m
- To: 122 m
- Intercept Depth: 121 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:121-122
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.18 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.18

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-948)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 1 m
- From: 121 m
- To: 122 m
- Intercept Depth: 121 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:121-122
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-949)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 1 m
- From: 121 m
- To: 122 m
- Intercept Depth: 121 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:121-122
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.9 g/t·m is below.

- Negative factor: 0.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.90

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-950)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 121 m
- To: 122 m
- Intercept Depth: 121 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:121-122
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-951)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 1 m
- From: 121 m
- To: 122 m
- Intercept Depth: 121 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:121-122
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-952)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8
- Grade Unit: ppm
- Intercept: 1 m
- From: 121 m
- To: 122 m
- Intercept Depth: 121 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:121-122
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 8 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 8

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-953)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 1 m
- From: 124 m
- To: 125 m
- Intercept Depth: 124 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:124-125
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.16 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-954)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 124 m
- To: 125 m
- Intercept Depth: 124 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:124-125
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-955)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 124 m
- To: 125 m
- Intercept Depth: 124 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:124-125
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-956)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 1 m
- From: 124 m
- To: 125 m
- Intercept Depth: 124 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:124-125
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-957)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9
- Grade Unit: ppm
- Intercept: 1 m
- From: 124 m
- To: 125 m
- Intercept Depth: 124 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:124-125
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 9 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 9

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-958)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 126 m
- To: 127 m
- Intercept Depth: 126 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:126-127
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-959)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 1 m
- From: 126 m
- To: 127 m
- Intercept Depth: 126 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:126-127
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.07 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-960)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 126 m
- To: 127 m
- Intercept Depth: 126 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:126-127
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-961)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 1 m
- From: 126 m
- To: 127 m
- Intercept Depth: 126 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:126-127
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.05 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-962)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 1 m
- From: 126 m
- To: 127 m
- Intercept Depth: 126 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:126-127
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-963)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 1 m
- From: 127 m
- To: 128 m
- Intercept Depth: 127 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:127-128
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-964)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 1 m
- From: 127 m
- To: 128 m
- Intercept Depth: 127 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:127-128
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-965)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.6
- Grade Unit: g/t
- Intercept: 1 m
- From: 127 m
- To: 128 m
- Intercept Depth: 127 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:127-128
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 0.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.60

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-966)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 127 m
- To: 128 m
- Intercept Depth: 127 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:127-128
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-967)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 1 m
- From: 127 m
- To: 128 m
- Intercept Depth: 127 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:127-128
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.05 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-968)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 1 m
- From: 127 m
- To: 128 m
- Intercept Depth: 127 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:127-128
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-969)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.59
- Grade Unit: %
- Intercept: 0.5 m
- From: 135 m
- To: 135.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-135.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.59 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.59

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-970)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.64
- Grade Unit: %
- Intercept: 0.5 m
- From: 135 m
- To: 135.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-135.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.64 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.64 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.64

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-971)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 135 m
- To: 135.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-135.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.0 g/t·m is below.

- Negative factor: 5.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.90

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-972)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 135 m
- To: 135.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-135.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-973)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 135 m
- To: 135.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-135.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-974)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 46
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 135 m
- To: 135.5 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135-135.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 46 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 46

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-975)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.45
- Grade Unit: %
- Intercept: 0.5 m
- From: 135.5 m
- To: 136 m
- Intercept Depth: 135.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135.5-136
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.45 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.45

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-976)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.8
- Grade Unit: %
- Intercept: 0.5 m
- From: 135.5 m
- To: 136 m
- Intercept Depth: 135.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135.5-136
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.4 %·m is below.

- Negative factor: 0.8 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.80

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-977)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 135.5 m
- To: 136 m
- Intercept Depth: 135.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135.5-136
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.2 g/t·m is below.

- Negative factor: 4.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.40

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-978)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 135.5 m
- To: 136 m
- Intercept Depth: 135.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135.5-136
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-979)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 135.5 m
- To: 136 m
- Intercept Depth: 135.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135.5-136
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-980)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 42
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 135.5 m
- To: 136 m
- Intercept Depth: 135.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:135.5-136
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 42 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 42

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-981)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.54
- Grade Unit: %
- Intercept: 0.5 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:136-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.54 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.54

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-982)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 0.5 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:136-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-983)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:136-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.5 g/t·m is below.

- Negative factor: 4.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.90

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-984)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:136-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-985)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:136-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-986)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 136 m
- To: 136.5 m
- Intercept Depth: 136 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:136-136.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 12 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 12

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-987)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 1 m
- From: 140 m
- To: 141 m
- Intercept Depth: 140 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:140-141
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-988)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 140 m
- To: 141 m
- Intercept Depth: 140 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:140-141
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-989)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.8
- Grade Unit: g/t
- Intercept: 1 m
- From: 140 m
- To: 141 m
- Intercept Depth: 140 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:140-141
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 0.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.80

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-990)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 1 m
- From: 140 m
- To: 141 m
- Intercept Depth: 140 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:140-141
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-991)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 140 m
- To: 141 m
- Intercept Depth: 140 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:140-141
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-992)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 22
- Grade Unit: ppm
- Intercept: 1 m
- From: 140 m
- To: 141 m
- Intercept Depth: 140 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:140-141
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 22 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 22

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-993)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 0.88 m
- From: 172.75 m
- To: 173.63 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-173.63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.23 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.23

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-994)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11.61
- Grade Unit: %
- Intercept: 0.88 m
- From: 172.75 m
- To: 173.63 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-173.63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 11.61 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 10.2 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 11.61 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 11.61

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-995)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.88 m
- From: 172.75 m
- To: 173.63 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-173.63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.6 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-996)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.88 m
- From: 172.75 m
- To: 173.63 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-173.63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-997)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.88 m
- From: 172.75 m
- To: 173.63 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-173.63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-998)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 67
- Grade Unit: ppm
- Intercept: 0.88 m
- From: 172.75 m
- To: 173.63 m
- Intercept Depth: 172.75 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:172.75-173.63
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 67 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 67

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-999)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 0.37 m
- From: 173.63 m
- To: 174 m
- Intercept Depth: 173.63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:173.63-174
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.12 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1000)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.65
- Grade Unit: %
- Intercept: 0.37 m
- From: 173.63 m
- To: 174 m
- Intercept Depth: 173.63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:173.63-174
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.65 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 1.0 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.65

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1001)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 0.37 m
- From: 173.63 m
- To: 174 m
- Intercept Depth: 173.63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:173.63-174
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.5 g/t·m is below.

- Negative factor: 1.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.30

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1002)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.37 m
- From: 173.63 m
- To: 174 m
- Intercept Depth: 173.63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:173.63-174
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1003)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.37 m
- From: 173.63 m
- To: 174 m
- Intercept Depth: 173.63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:173.63-174
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1004)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 20
- Grade Unit: ppm
- Intercept: 0.37 m
- From: 173.63 m
- To: 174 m
- Intercept Depth: 173.63 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:173.63-174
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 20 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 20

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1005)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.24
- Grade Unit: %
- Intercept: 0.5 m
- From: 175 m
- To: 175.5 m
- Intercept Depth: 175 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175-175.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.24 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.24

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1006)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.35
- Grade Unit: %
- Intercept: 0.5 m
- From: 175 m
- To: 175.5 m
- Intercept Depth: 175 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175-175.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.35 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 1.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.35

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1007)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 175 m
- To: 175.5 m
- Intercept Depth: 175 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175-175.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.5 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1008)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 175 m
- To: 175.5 m
- Intercept Depth: 175 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175-175.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1009)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 175 m
- To: 175.5 m
- Intercept Depth: 175 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175-175.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1010)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 25
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 175 m
- To: 175.5 m
- Intercept Depth: 175 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175-175.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 25 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 25

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1011)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.5 m
- From: 175.5 m
- To: 176 m
- Intercept Depth: 175.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175.5-176
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.3 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.30

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1012)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.82
- Grade Unit: %
- Intercept: 0.5 m
- From: 175.5 m
- To: 176 m
- Intercept Depth: 175.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175.5-176
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.82 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 2.4 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.82

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1013)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 175.5 m
- To: 176 m
- Intercept Depth: 175.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175.5-176
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.0 g/t·m is below.

- Negative factor: 6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1014)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 175.5 m
- To: 176 m
- Intercept Depth: 175.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175.5-176
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1015)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 175.5 m
- To: 176 m
- Intercept Depth: 175.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175.5-176
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1016)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 51
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 175.5 m
- To: 176 m
- Intercept Depth: 175.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:175.5-176
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 51 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 51

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1017)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 0.5 m
- From: 176 m
- To: 176.5 m
- Intercept Depth: 176 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:176-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.16 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1018)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.69
- Grade Unit: %
- Intercept: 0.5 m
- From: 176 m
- To: 176.5 m
- Intercept Depth: 176 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:176-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.69 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.69 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.69

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1019)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 176 m
- To: 176.5 m
- Intercept Depth: 176 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:176-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.3 g/t·m is below.

- Negative factor: 6.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.50

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1020)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 176 m
- To: 176.5 m
- Intercept Depth: 176 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:176-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1021)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 176 m
- To: 176.5 m
- Intercept Depth: 176 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:176-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1022)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 176 m
- To: 176.5 m
- Intercept Depth: 176 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:176-176.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1023)

Rush target · copper

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 178.5 m
- To: 179 m
- Intercept Depth: 178.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178.5-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1024)

Rush target · zinc

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10
- Grade Unit: %
- Intercept: 0.5 m
- From: 178.5 m
- To: 179 m
- Intercept Depth: 178.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178.5-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 5.0 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 10 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1025)

Rush target · silver

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 178.5 m
- To: 179 m
- Intercept Depth: 178.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178.5-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.5 g/t·m is below.

- Negative factor: 3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.00

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1026)

Rush target · gold

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 178.5 m
- To: 179 m
- Intercept Depth: 178.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178.5-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1027)

Rush target · lead

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 178.5 m
- To: 179 m
- Intercept Depth: 178.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178.5-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1028)

Rush target · cobalt

#### Identity

- Hole ID: Rush-009
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 52
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 178.5 m
- To: 179 m
- Intercept Depth: 178.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-009:178.5-179
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 52 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 52

Context: Rush-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1029)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 16 m
- To: 17 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:16-17
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1030)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 1 m
- From: 16 m
- To: 17 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:16-17
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1031)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.7
- Grade Unit: g/t
- Intercept: 1 m
- From: 16 m
- To: 17 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:16-17
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.7 g/t·m is below.

- Negative factor: 0.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.70

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1032)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 1 m
- From: 16 m
- To: 17 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:16-17
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1033)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 1 m
- From: 16 m
- To: 17 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:16-17
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1034)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: ppm
- Intercept: 1 m
- From: 16 m
- To: 17 m
- Intercept Depth: 16 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:16-17
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 6 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 6

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1035)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.44
- Grade Unit: %
- Intercept: 0.5 m
- From: 18 m
- To: 18.5 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-18.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.44 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.44

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1036)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 18 m
- To: 18.5 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-18.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1037)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 18 m
- To: 18.5 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-18.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.9 g/t·m is below.

- Negative factor: 9.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.80

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1038)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 18 m
- To: 18.5 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-18.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.09 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1039)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 18 m
- To: 18.5 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-18.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1040)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 41
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 18 m
- To: 18.5 m
- Intercept Depth: 18 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18-18.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 41 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 41

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1041)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 0.5 m
- From: 18.5 m
- To: 19 m
- Intercept Depth: 18.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18.5-19
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.22 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.22

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1042)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 18.5 m
- To: 19 m
- Intercept Depth: 18.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18.5-19
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.07 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1043)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 18.5 m
- To: 19 m
- Intercept Depth: 18.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18.5-19
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.9 g/t·m is below.

- Negative factor: 1.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.90

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1044)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 18.5 m
- To: 19 m
- Intercept Depth: 18.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18.5-19
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.04 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1045)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 18.5 m
- To: 19 m
- Intercept Depth: 18.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18.5-19
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1046)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 28
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 18.5 m
- To: 19 m
- Intercept Depth: 18.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:18.5-19
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 28 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 28

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1047)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 19 m
- To: 19.5 m
- Intercept Depth: 19 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19-19.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1048)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 0.5 m
- From: 19 m
- To: 19.5 m
- Intercept Depth: 19 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19-19.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1049)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 19 m
- To: 19.5 m
- Intercept Depth: 19 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19-19.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.0 g/t·m is below.

- Negative factor: 6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1050)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 19 m
- To: 19.5 m
- Intercept Depth: 19 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19-19.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1051)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 0.5 m
- From: 19 m
- To: 19.5 m
- Intercept Depth: 19 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19-19.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1052)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 17
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 19 m
- To: 19.5 m
- Intercept Depth: 19 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19-19.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 17 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 17

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1053)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.5 m
- From: 19.5 m
- To: 20 m
- Intercept Depth: 19.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19.5-20
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.3 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1054)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 0.5 m
- From: 19.5 m
- To: 20 m
- Intercept Depth: 19.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19.5-20
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1055)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 19.5 m
- To: 20 m
- Intercept Depth: 19.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19.5-20
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1056)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 19.5 m
- To: 20 m
- Intercept Depth: 19.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19.5-20
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.12 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1057)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 19.5 m
- To: 20 m
- Intercept Depth: 19.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19.5-20
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1058)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 19.5 m
- To: 20 m
- Intercept Depth: 19.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:19.5-20
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1059)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 0.5 m
- From: 20.5 m
- To: 21 m
- Intercept Depth: 20.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:20.5-21
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.18 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.18

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1060)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.5 m
- From: 20.5 m
- To: 21 m
- Intercept Depth: 20.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:20.5-21
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.3 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1061)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 20.5 m
- To: 21 m
- Intercept Depth: 20.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:20.5-21
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.5 g/t·m is below.

- Negative factor: 0.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.90

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1062)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 20.5 m
- To: 21 m
- Intercept Depth: 20.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:20.5-21
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1063)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 0.5 m
- From: 20.5 m
- To: 21 m
- Intercept Depth: 20.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:20.5-21
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.17 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1064)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 20.5 m
- To: 21 m
- Intercept Depth: 20.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:20.5-21
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1065)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 21 m
- To: 21.5 m
- Intercept Depth: 21 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21-21.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1066)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.47
- Grade Unit: %
- Intercept: 0.5 m
- From: 21 m
- To: 21.5 m
- Intercept Depth: 21 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21-21.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.47 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 1.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.47

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1067)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 21 m
- To: 21.5 m
- Intercept Depth: 21 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21-21.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 1.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1068)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 21 m
- To: 21.5 m
- Intercept Depth: 21 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21-21.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1069)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 0.5 m
- From: 21 m
- To: 21.5 m
- Intercept Depth: 21 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21-21.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.19 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.19

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1070)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 38
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 21 m
- To: 21.5 m
- Intercept Depth: 21 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21-21.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 38 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 38

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1071)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.55
- Grade Unit: %
- Intercept: 0.5 m
- From: 21.5 m
- To: 22 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-22
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.55 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.55

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1072)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13.97
- Grade Unit: %
- Intercept: 0.5 m
- From: 21.5 m
- To: 22 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-22
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 13.97 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 7.0 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 13.97 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.97

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1073)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 37.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 21.5 m
- To: 22 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-22
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 37.7 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 18.9 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 37.70

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1074)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 21.5 m
- To: 22 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-22
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1075)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.62
- Grade Unit: %
- Intercept: 0.5 m
- From: 21.5 m
- To: 22 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-22
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.62 % lead is moderate against the default band \[10, 6, 3, 1\] %. Grade×width 2.8 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.62

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1076)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 100
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 21.5 m
- To: 22 m
- Intercept Depth: 21.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:21.5-22
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 100 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 100

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1077)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 0.5 m
- From: 22 m
- To: 22.5 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22-22.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.21 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.21

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1078)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.58
- Grade Unit: %
- Intercept: 0.5 m
- From: 22 m
- To: 22.5 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22-22.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.58 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 3.3 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.58

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1079)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 22 m
- To: 22.5 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22-22.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.3 g/t·m is below.

- Negative factor: 10.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1080)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 22 m
- To: 22.5 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22-22.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1081)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.33
- Grade Unit: %
- Intercept: 0.5 m
- From: 22 m
- To: 22.5 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22-22.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.33 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 0.7 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.33

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1082)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 20
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 22 m
- To: 22.5 m
- Intercept Depth: 22 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22-22.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 20 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1083)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.27
- Grade Unit: %
- Intercept: 0.5 m
- From: 22.5 m
- To: 23 m
- Intercept Depth: 22.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22.5-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.27 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.27

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1084)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 19.34
- Grade Unit: %
- Intercept: 0.5 m
- From: 22.5 m
- To: 23 m
- Intercept Depth: 22.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22.5-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 19.34 % zinc is exceptional against the default band \[18, 10, 5, 2\] %. Grade×width 9.7 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 19.34 % zinc is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 19.34

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1085)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 54
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 22.5 m
- To: 23 m
- Intercept Depth: 22.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22.5-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 54 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 27.0 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 54.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1086)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 22.5 m
- To: 23 m
- Intercept Depth: 22.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22.5-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1087)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8.77
- Grade Unit: %
- Intercept: 0.5 m
- From: 22.5 m
- To: 23 m
- Intercept Depth: 22.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22.5-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8.77 % lead is strong against the default band \[10, 6, 3, 1\] %. Grade×width 4.4 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 8.77 % lead is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.77

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1088)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 112
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 22.5 m
- To: 23 m
- Intercept Depth: 22.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:22.5-23
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 112 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 112

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1089)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.37
- Grade Unit: %
- Intercept: 0.5 m
- From: 23 m
- To: 23.5 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23-23.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.37 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.37 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.37

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1090)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13.53
- Grade Unit: %
- Intercept: 0.5 m
- From: 23 m
- To: 23.5 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23-23.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 13.53 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 6.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 13.53 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.53

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1091)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 19.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 23 m
- To: 23.5 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23-23.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 19.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 9.8 g/t·m is below.

- Negative factor: 19.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 19.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1092)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 23 m
- To: 23.5 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23-23.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1093)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.75
- Grade Unit: %
- Intercept: 0.5 m
- From: 23 m
- To: 23.5 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23-23.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.75 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 1.4 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.75

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1094)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 108
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 23 m
- To: 23.5 m
- Intercept Depth: 23 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23-23.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 108 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 108

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1095)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.99
- Grade Unit: %
- Intercept: 0.5 m
- From: 23.5 m
- To: 24 m
- Intercept Depth: 23.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23.5-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.99 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.5 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.99

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1096)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.55
- Grade Unit: %
- Intercept: 0.5 m
- From: 23.5 m
- To: 24 m
- Intercept Depth: 23.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23.5-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.55 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.8 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.55

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1097)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 23.5 m
- To: 24 m
- Intercept Depth: 23.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23.5-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.0 g/t·m is below.

- Negative factor: 4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1098)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 23.5 m
- To: 24 m
- Intercept Depth: 23.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23.5-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1099)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 23.5 m
- To: 24 m
- Intercept Depth: 23.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23.5-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1100)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 110
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 23.5 m
- To: 24 m
- Intercept Depth: 23.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:23.5-24
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 110 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 110

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1101)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.34
- Grade Unit: %
- Intercept: 0.5 m
- From: 24 m
- To: 24.5 m
- Intercept Depth: 24 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24-24.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.34 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.34 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.34

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1102)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.06
- Grade Unit: %
- Intercept: 0.5 m
- From: 24 m
- To: 24.5 m
- Intercept Depth: 24 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24-24.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.06 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 4.5 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.06

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1103)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 24 m
- To: 24.5 m
- Intercept Depth: 24 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24-24.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.4 g/t·m is below.

- Negative factor: 2.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.70

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1104)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 24 m
- To: 24.5 m
- Intercept Depth: 24 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24-24.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1105)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 0.5 m
- From: 24 m
- To: 24.5 m
- Intercept Depth: 24 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24-24.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.17 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1106)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 79
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 24 m
- To: 24.5 m
- Intercept Depth: 24 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24-24.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 79 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 79

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1107)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.38
- Grade Unit: %
- Intercept: 0.5 m
- From: 24.5 m
- To: 25 m
- Intercept Depth: 24.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24.5-25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.38 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.7 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.38

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1108)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.15
- Grade Unit: %
- Intercept: 0.5 m
- From: 24.5 m
- To: 25 m
- Intercept Depth: 24.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24.5-25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.15 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 1.1 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1109)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 24.5 m
- To: 25 m
- Intercept Depth: 24.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24.5-25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 8.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.3 g/t·m is below.

- Negative factor: 8.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1110)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 24.5 m
- To: 25 m
- Intercept Depth: 24.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24.5-25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1111)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.86
- Grade Unit: %
- Intercept: 0.5 m
- From: 24.5 m
- To: 25 m
- Intercept Depth: 24.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24.5-25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.86 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.4 %·m is below.

- Negative factor: 0.86 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.86

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1112)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 63
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 24.5 m
- To: 25 m
- Intercept Depth: 24.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:24.5-25
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 63 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 63

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1113)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.06
- Grade Unit: %
- Intercept: 0.5 m
- From: 25 m
- To: 25.5 m
- Intercept Depth: 25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.06 % copper is exceptional against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.5 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 3.06 % copper is exceptional on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.06

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1114)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.76
- Grade Unit: %
- Intercept: 0.5 m
- From: 25 m
- To: 25.5 m
- Intercept Depth: 25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.76 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 2.9 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.76

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1115)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 25 m
- To: 25.5 m
- Intercept Depth: 25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 13.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.7 g/t·m is below.

- Negative factor: 13.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1116)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 25 m
- To: 25.5 m
- Intercept Depth: 25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1117)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 25 m
- To: 25.5 m
- Intercept Depth: 25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.12 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 0.6 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.12

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1118)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 84
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 25 m
- To: 25.5 m
- Intercept Depth: 25 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25-25.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 84 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 84

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1119)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 0.5 m
- From: 25.5 m
- To: 26 m
- Intercept Depth: 25.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25.5-26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.32 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.32

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1120)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 0.5 m
- From: 25.5 m
- To: 26 m
- Intercept Depth: 25.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25.5-26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.32 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.32

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1121)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 25.5 m
- To: 26 m
- Intercept Depth: 25.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25.5-26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.6 g/t·m is below.

- Negative factor: 5.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1122)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 25.5 m
- To: 26 m
- Intercept Depth: 25.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25.5-26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1123)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.5
- Grade Unit: %
- Intercept: 0.5 m
- From: 25.5 m
- To: 26 m
- Intercept Depth: 25.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25.5-26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.5 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1124)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 25.5 m
- To: 26 m
- Intercept Depth: 25.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:25.5-26
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1125)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 0.5 m
- From: 26 m
- To: 26.5 m
- Intercept Depth: 26 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26-26.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.25 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.25 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.25

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1126)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.92
- Grade Unit: %
- Intercept: 0.5 m
- From: 26 m
- To: 26.5 m
- Intercept Depth: 26 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26-26.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.92 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 1.0 %·m is below.

- Negative factor: 1.92 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.92

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1127)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 26 m
- To: 26.5 m
- Intercept Depth: 26 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26-26.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.1 g/t·m is below.

- Negative factor: 2.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1128)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 26 m
- To: 26.5 m
- Intercept Depth: 26 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26-26.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1129)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 0.5 m
- From: 26 m
- To: 26.5 m
- Intercept Depth: 26 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26-26.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.25 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.25 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.25

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1130)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 19
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 26 m
- To: 26.5 m
- Intercept Depth: 26 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26-26.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 19 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 19

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1131)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.38
- Grade Unit: %
- Intercept: 0.5 m
- From: 26.5 m
- To: 27 m
- Intercept Depth: 26.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26.5-27
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.38 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.38 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.38

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1132)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.67
- Grade Unit: %
- Intercept: 0.5 m
- From: 26.5 m
- To: 27 m
- Intercept Depth: 26.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26.5-27
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.67 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.8 %·m is below.

- Negative factor: 1.67 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.67

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1133)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 26.5 m
- To: 27 m
- Intercept Depth: 26.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26.5-27
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.3 g/t·m is below.

- Negative factor: 2.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1134)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 26.5 m
- To: 27 m
- Intercept Depth: 26.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26.5-27
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1135)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 26.5 m
- To: 27 m
- Intercept Depth: 26.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26.5-27
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1136)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 27
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 26.5 m
- To: 27 m
- Intercept Depth: 26.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:26.5-27
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 27 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 27

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1137)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 0.5 m
- From: 27 m
- To: 27.5 m
- Intercept Depth: 27 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27-27.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.21 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.21

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1138)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 0.5 m
- From: 27 m
- To: 27.5 m
- Intercept Depth: 27 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27-27.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.4 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1139)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 27 m
- To: 27.5 m
- Intercept Depth: 27 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27-27.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.7 g/t·m is below.

- Negative factor: 1.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1140)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 27 m
- To: 27.5 m
- Intercept Depth: 27 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27-27.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1141)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 0.5 m
- From: 27 m
- To: 27.5 m
- Intercept Depth: 27 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27-27.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.09 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1142)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 27 m
- To: 27.5 m
- Intercept Depth: 27 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27-27.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1143)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 0.5 m
- From: 27.5 m
- To: 28 m
- Intercept Depth: 27.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27.5-28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.22 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.22

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1144)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 0.5 m
- From: 27.5 m
- To: 28 m
- Intercept Depth: 27.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27.5-28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.15 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1145)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 9.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 27.5 m
- To: 28 m
- Intercept Depth: 27.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27.5-28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 9.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 4.9 g/t·m is below.

- Negative factor: 9.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 9.80

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1146)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 27.5 m
- To: 28 m
- Intercept Depth: 27.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27.5-28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1147)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.9
- Grade Unit: %
- Intercept: 0.5 m
- From: 27.5 m
- To: 28 m
- Intercept Depth: 27.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27.5-28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.5 %·m is below.

- Negative factor: 0.9 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.90

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1148)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 27.5 m
- To: 28 m
- Intercept Depth: 27.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:27.5-28
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1149)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 28 m
- To: 28.5 m
- Intercept Depth: 28 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28-28.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1150)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 28 m
- To: 28.5 m
- Intercept Depth: 28 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28-28.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1151)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 28 m
- To: 28.5 m
- Intercept Depth: 28 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28-28.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.2 g/t·m is below.

- Negative factor: 4.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1152)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 28 m
- To: 28.5 m
- Intercept Depth: 28 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28-28.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1153)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 0.5 m
- From: 28 m
- To: 28.5 m
- Intercept Depth: 28 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28-28.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.32 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.32

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1154)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 28 m
- To: 28.5 m
- Intercept Depth: 28 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28-28.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 5 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 5

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1155)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 0.5 m
- From: 28.5 m
- To: 29 m
- Intercept Depth: 28.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28.5-29
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.21 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.21

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1156)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.47
- Grade Unit: %
- Intercept: 0.5 m
- From: 28.5 m
- To: 29 m
- Intercept Depth: 28.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28.5-29
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.47 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.47 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.47

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1157)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 28.5 m
- To: 29 m
- Intercept Depth: 28.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28.5-29
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.7 g/t·m is below.

- Negative factor: 5.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1158)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 28.5 m
- To: 29 m
- Intercept Depth: 28.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28.5-29
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1159)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.38
- Grade Unit: %
- Intercept: 0.5 m
- From: 28.5 m
- To: 29 m
- Intercept Depth: 28.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28.5-29
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.38 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.38 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.38

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1160)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 28.5 m
- To: 29 m
- Intercept Depth: 28.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:28.5-29
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1161)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 29 m
- To: 29.5 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29-29.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1162)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.66
- Grade Unit: %
- Intercept: 0.5 m
- From: 29 m
- To: 29.5 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29-29.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.66 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.66 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.66

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1163)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 29 m
- To: 29.5 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29-29.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 1.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1164)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 29 m
- To: 29.5 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29-29.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1165)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 0.5 m
- From: 29 m
- To: 29.5 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29-29.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1166)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 8
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 29 m
- To: 29.5 m
- Intercept Depth: 29 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29-29.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 8 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 8

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1167)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.33
- Grade Unit: %
- Intercept: 0.5 m
- From: 29.5 m
- To: 30 m
- Intercept Depth: 29.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29.5-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.33 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.33

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1168)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.76
- Grade Unit: %
- Intercept: 0.5 m
- From: 29.5 m
- To: 30 m
- Intercept Depth: 29.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29.5-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.76 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.4 %·m is below.

- Negative factor: 0.76 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.76

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1169)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 29.5 m
- To: 30 m
- Intercept Depth: 29.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29.5-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.1 g/t·m is below.

- Negative factor: 2.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1170)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 29.5 m
- To: 30 m
- Intercept Depth: 29.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29.5-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1171)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 29.5 m
- To: 30 m
- Intercept Depth: 29.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29.5-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1172)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 29.5 m
- To: 30 m
- Intercept Depth: 29.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:29.5-30
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1173)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.16 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1174)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1175)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.8 g/t·m is below.

- Negative factor: 3.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.60

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1176)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1177)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.07 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1178)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 32 m
- To: 32.5 m
- Intercept Depth: 32 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32-32.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1179)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1180)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.05 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1181)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.5 g/t·m is below.

- Negative factor: 1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1182)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1183)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1184)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 21
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 32.5 m
- To: 33 m
- Intercept Depth: 32.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:32.5-33
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 21 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 21

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1185)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 33 m
- To: 33.5 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33-33.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1186)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.5 m
- From: 33 m
- To: 33.5 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33-33.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1187)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 33 m
- To: 33.5 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33-33.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 6.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.2 g/t·m is below.

- Negative factor: 6.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 6.40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1188)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 33 m
- To: 33.5 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33-33.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1189)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.52
- Grade Unit: %
- Intercept: 0.5 m
- From: 33 m
- To: 33.5 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33-33.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.52 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.52 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.52

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1190)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 33 m
- To: 33.5 m
- Intercept Depth: 33 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33-33.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1191)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.36
- Grade Unit: %
- Intercept: 0.5 m
- From: 33.5 m
- To: 34 m
- Intercept Depth: 33.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33.5-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.36 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.36 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.36

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1192)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 33.5 m
- To: 34 m
- Intercept Depth: 33.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33.5-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1193)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 33.5 m
- To: 34 m
- Intercept Depth: 33.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33.5-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.0 g/t·m is below.

- Negative factor: 10.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1194)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 33.5 m
- To: 34 m
- Intercept Depth: 33.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33.5-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1195)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.5 m
- From: 33.5 m
- To: 34 m
- Intercept Depth: 33.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33.5-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.3 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1196)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 33.5 m
- To: 34 m
- Intercept Depth: 33.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:33.5-34
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1197)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 0.5 m
- From: 34 m
- To: 34.5 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34-34.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.32 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.32

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1198)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.39
- Grade Unit: %
- Intercept: 0.5 m
- From: 34 m
- To: 34.5 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34-34.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.39 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.39 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.39

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1199)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 34 m
- To: 34.5 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34-34.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.3 g/t·m is below.

- Negative factor: 2.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.60

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1200)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 34 m
- To: 34.5 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34-34.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1201)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 34 m
- To: 34.5 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34-34.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1202)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 53
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 34 m
- To: 34.5 m
- Intercept Depth: 34 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34-34.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 53 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 53

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1203)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.5
- Grade Unit: %
- Intercept: 0.5 m
- From: 34.5 m
- To: 35 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.5 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1204)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.2
- Grade Unit: %
- Intercept: 0.5 m
- From: 34.5 m
- To: 35 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.2 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.2 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1205)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 34.5 m
- To: 35 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.8 g/t·m is below.

- Negative factor: 3.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1206)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 34.5 m
- To: 35 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1207)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 34.5 m
- To: 35 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1208)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 29
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 34.5 m
- To: 35 m
- Intercept Depth: 34.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:34.5-35
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 29 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 29

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1209)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.66
- Grade Unit: %
- Intercept: 0.5 m
- From: 35 m
- To: 35.5 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35-35.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.66 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.66

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1210)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.33
- Grade Unit: %
- Intercept: 0.5 m
- From: 35 m
- To: 35.5 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35-35.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.33 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.33

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1211)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 35 m
- To: 35.5 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35-35.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 10.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.1 g/t·m is below.

- Negative factor: 10.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 10.20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1212)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 35 m
- To: 35.5 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35-35.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1213)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.17
- Grade Unit: %
- Intercept: 0.5 m
- From: 35 m
- To: 35.5 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35-35.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.17 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.17 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.17

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1214)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 35 m
- To: 35.5 m
- Intercept Depth: 35 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35-35.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1215)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.71
- Grade Unit: %
- Intercept: 0.5 m
- From: 35.5 m
- To: 36 m
- Intercept Depth: 35.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35.5-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.71 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.4 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.71

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1216)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 0.5 m
- From: 35.5 m
- To: 36 m
- Intercept Depth: 35.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35.5-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.19 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.19

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1217)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 35.5 m
- To: 36 m
- Intercept Depth: 35.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35.5-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.0 g/t·m is below.

- Negative factor: 5.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.90

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1218)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 35.5 m
- To: 36 m
- Intercept Depth: 35.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35.5-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1219)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 35.5 m
- To: 36 m
- Intercept Depth: 35.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35.5-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1220)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 34
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 35.5 m
- To: 36 m
- Intercept Depth: 35.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:35.5-36
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 34 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 34

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1221)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.54
- Grade Unit: %
- Intercept: 0.5 m
- From: 36 m
- To: 36.5 m
- Intercept Depth: 36 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36-36.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.54 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.54

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1222)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 0.5 m
- From: 36 m
- To: 36.5 m
- Intercept Depth: 36 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36-36.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1223)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 36 m
- To: 36.5 m
- Intercept Depth: 36 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36-36.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 15.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 7.9 g/t·m is below.

- Negative factor: 15.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 15.80

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1224)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 36 m
- To: 36.5 m
- Intercept Depth: 36 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36-36.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.09 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1225)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.21
- Grade Unit: %
- Intercept: 0.5 m
- From: 36 m
- To: 36.5 m
- Intercept Depth: 36 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36-36.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.21 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.21

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1226)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 30
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 36 m
- To: 36.5 m
- Intercept Depth: 36 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36-36.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 30 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1227)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 36.5 m
- To: 37 m
- Intercept Depth: 36.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36.5-37
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.11 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.11

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1228)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 0.5 m
- From: 36.5 m
- To: 37 m
- Intercept Depth: 36.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36.5-37
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.16 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1229)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 24.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 36.5 m
- To: 37 m
- Intercept Depth: 36.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36.5-37
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 24.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 12.4 g/t·m is below.

- Negative factor: 24.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 24.80

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1230)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 36.5 m
- To: 37 m
- Intercept Depth: 36.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36.5-37
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.09 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1231)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.33
- Grade Unit: %
- Intercept: 0.5 m
- From: 36.5 m
- To: 37 m
- Intercept Depth: 36.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36.5-37
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.33 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.33

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1232)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 31
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 36.5 m
- To: 37 m
- Intercept Depth: 36.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:36.5-37
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 31 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 31

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1233)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.13
- Grade Unit: %
- Intercept: 0.5 m
- From: 37 m
- To: 37.5 m
- Intercept Depth: 37 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37-37.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.13 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1234)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.93
- Grade Unit: %
- Intercept: 0.5 m
- From: 37 m
- To: 37.5 m
- Intercept Depth: 37 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37-37.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.93 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.5 %·m is below.

- Negative factor: 0.93 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.93

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1235)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 21.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 37 m
- To: 37.5 m
- Intercept Depth: 37 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37-37.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 21.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 10.8 g/t·m is below.

- Negative factor: 21.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 21.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1236)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 37 m
- To: 37.5 m
- Intercept Depth: 37 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37-37.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.08 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1237)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.25
- Grade Unit: %
- Intercept: 0.5 m
- From: 37 m
- To: 37.5 m
- Intercept Depth: 37 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37-37.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.25 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.25 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.25

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1238)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 31
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 37 m
- To: 37.5 m
- Intercept Depth: 37 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37-37.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 31 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 31

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1239)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.77
- Grade Unit: %
- Intercept: 0.5 m
- From: 37.5 m
- To: 38 m
- Intercept Depth: 37.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37.5-38
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.77 % copper is exceptional against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.4 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 2.77 % copper is exceptional on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.77

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1240)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.98
- Grade Unit: %
- Intercept: 0.5 m
- From: 37.5 m
- To: 38 m
- Intercept Depth: 37.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37.5-38
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.98 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 1.0 %·m is below.

- Negative factor: 1.98 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.98

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1241)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 39
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 37.5 m
- To: 38 m
- Intercept Depth: 37.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37.5-38
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 39 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 19.5 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 39.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1242)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 37.5 m
- To: 38 m
- Intercept Depth: 37.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37.5-38
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.18 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.18

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1243)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.31
- Grade Unit: %
- Intercept: 0.5 m
- From: 37.5 m
- To: 38 m
- Intercept Depth: 37.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37.5-38
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.31 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.31 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.31

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1244)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 56
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 37.5 m
- To: 38 m
- Intercept Depth: 37.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:37.5-38
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 56 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 56

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1245)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 38 m
- To: 38.5 m
- Intercept Depth: 38 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38-38.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.04 % copper is strong against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.0 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 2.04 % copper is strong on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1246)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 38 m
- To: 38.5 m
- Intercept Depth: 38 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38-38.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.01 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.5 %·m is below.

- Negative factor: 1.01 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1247)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16.2
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 38 m
- To: 38.5 m
- Intercept Depth: 38 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38-38.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 16.2 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 8.1 g/t·m is below.

- Negative factor: 16.2 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 16.20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1248)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 38 m
- To: 38.5 m
- Intercept Depth: 38 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38-38.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.11 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1249)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 38 m
- To: 38.5 m
- Intercept Depth: 38 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38-38.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1250)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 98
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 38 m
- To: 38.5 m
- Intercept Depth: 38 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38-38.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 98 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 98

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1251)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.37
- Grade Unit: %
- Intercept: 0.5 m
- From: 38.5 m
- To: 39 m
- Intercept Depth: 38.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38.5-39
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.37 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.7 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.37

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1252)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.52
- Grade Unit: %
- Intercept: 0.5 m
- From: 38.5 m
- To: 39 m
- Intercept Depth: 38.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38.5-39
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.52 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.52 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.52

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1253)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 38.5 m
- To: 39 m
- Intercept Depth: 38.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38.5-39
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 13.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 7.0 g/t·m is below.

- Negative factor: 13.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 13.90

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1254)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 38.5 m
- To: 39 m
- Intercept Depth: 38.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38.5-39
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.07 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1255)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.5 m
- From: 38.5 m
- To: 39 m
- Intercept Depth: 38.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38.5-39
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1256)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 53
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 38.5 m
- To: 39 m
- Intercept Depth: 38.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:38.5-39
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 53 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 53

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1257)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 39 m
- To: 39.5 m
- Intercept Depth: 39 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39-39.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.11 % copper is strong against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.1 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 2.11 % copper is strong on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.11

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1258)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.09
- Grade Unit: %
- Intercept: 0.5 m
- From: 39 m
- To: 39.5 m
- Intercept Depth: 39 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39-39.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.5 %·m is below.

- Negative factor: 1.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.09

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1259)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 21.5
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 39 m
- To: 39.5 m
- Intercept Depth: 39 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39-39.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 21.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 10.8 g/t·m is below.

- Negative factor: 21.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 21.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1260)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 39 m
- To: 39.5 m
- Intercept Depth: 39 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39-39.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.15 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1261)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 39 m
- To: 39.5 m
- Intercept Depth: 39 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39-39.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1262)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 138
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 39 m
- To: 39.5 m
- Intercept Depth: 39 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39-39.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 138 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 138

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1263)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.14
- Grade Unit: %
- Intercept: 0.5 m
- From: 39.5 m
- To: 40 m
- Intercept Depth: 39.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39.5-40
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.14 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.6 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.14

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1264)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.49
- Grade Unit: %
- Intercept: 0.5 m
- From: 39.5 m
- To: 40 m
- Intercept Depth: 39.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39.5-40
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.49 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.49 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.49

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1265)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11.9
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 39.5 m
- To: 40 m
- Intercept Depth: 39.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39.5-40
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 11.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.0 g/t·m is below.

- Negative factor: 11.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 11.90

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1266)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.18
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 39.5 m
- To: 40 m
- Intercept Depth: 39.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39.5-40
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.18 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.18 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.18

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1267)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 39.5 m
- To: 40 m
- Intercept Depth: 39.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39.5-40
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1268)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 54
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 39.5 m
- To: 40 m
- Intercept Depth: 39.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:39.5-40
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 54 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 54

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1269)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.52
- Grade Unit: %
- Intercept: 0.5 m
- From: 40 m
- To: 40.5 m
- Intercept Depth: 40 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:40-40.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.52 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.52

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1270)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 0.5 m
- From: 40 m
- To: 40.5 m
- Intercept Depth: 40 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:40-40.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.23 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.23

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1271)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 5.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 40 m
- To: 40.5 m
- Intercept Depth: 40 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:40-40.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 5.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 2.9 g/t·m is below.

- Negative factor: 5.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 5.80

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1272)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 40 m
- To: 40.5 m
- Intercept Depth: 40 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:40-40.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1273)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 40 m
- To: 40.5 m
- Intercept Depth: 40 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:40-40.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1274)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 44
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 40 m
- To: 40.5 m
- Intercept Depth: 40 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:40-40.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 44 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 44

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1275)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.85
- Grade Unit: %
- Intercept: 0.5 m
- From: 41 m
- To: 41.5 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41-41.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.85 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.4 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.85

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1276)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.09
- Grade Unit: %
- Intercept: 0.5 m
- From: 41 m
- To: 41.5 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41-41.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.5 %·m is below.

- Negative factor: 1.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.09

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1277)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 41 m
- To: 41.5 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41-41.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 18.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 9.2 g/t·m is below.

- Negative factor: 18.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 18.40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1278)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 41 m
- To: 41.5 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41-41.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.08 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1279)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 0.5 m
- From: 41 m
- To: 41.5 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41-41.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.16 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1280)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 59
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 41 m
- To: 41.5 m
- Intercept Depth: 41 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41-41.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 59 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 59

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1281)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.55
- Grade Unit: %
- Intercept: 0.5 m
- From: 41.5 m
- To: 42 m
- Intercept Depth: 41.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41.5-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.55 % copper is strong against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.8 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.55 % copper is strong on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.55

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1282)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.69
- Grade Unit: %
- Intercept: 0.5 m
- From: 41.5 m
- To: 42 m
- Intercept Depth: 41.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41.5-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.69 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.69 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.69

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1283)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 84.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 41.5 m
- To: 42 m
- Intercept Depth: 41.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41.5-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 84.3 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 42.1 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 84.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1284)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.24
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 41.5 m
- To: 42 m
- Intercept Depth: 41.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41.5-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.24 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.24 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.24

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1285)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.27
- Grade Unit: %
- Intercept: 0.5 m
- From: 41.5 m
- To: 42 m
- Intercept Depth: 41.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41.5-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.27 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 0.6 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.27

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1286)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 42
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 41.5 m
- To: 42 m
- Intercept Depth: 41.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:41.5-42
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 42 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 42

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1287)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.8
- Grade Unit: %
- Intercept: 0.5 m
- From: 42 m
- To: 42.5 m
- Intercept Depth: 42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42-42.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.8 % copper is exceptional against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.4 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 2.8 % copper is exceptional on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.80

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1288)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.08
- Grade Unit: %
- Intercept: 0.5 m
- From: 42 m
- To: 42.5 m
- Intercept Depth: 42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42-42.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.08 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 1.0 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.08

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1289)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 55
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 42 m
- To: 42.5 m
- Intercept Depth: 42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42-42.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 55 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 27.5 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 55.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1290)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.14
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 42 m
- To: 42.5 m
- Intercept Depth: 42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42-42.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.14 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1291)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 42 m
- To: 42.5 m
- Intercept Depth: 42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42-42.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1292)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 62
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 42 m
- To: 42.5 m
- Intercept Depth: 42 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42-42.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 62 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 62

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1293)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.95
- Grade Unit: %
- Intercept: 0.5 m
- From: 42.5 m
- To: 43 m
- Intercept Depth: 42.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42.5-43
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.95 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.5 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.95

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1294)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.16
- Grade Unit: %
- Intercept: 0.5 m
- From: 42.5 m
- To: 43 m
- Intercept Depth: 42.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42.5-43
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.16 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.16 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.16

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1295)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 12.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 42.5 m
- To: 43 m
- Intercept Depth: 42.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42.5-43
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 12.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 6.2 g/t·m is below.

- Negative factor: 12.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 12.40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1296)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 42.5 m
- To: 43 m
- Intercept Depth: 42.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42.5-43
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1297)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 42.5 m
- To: 43 m
- Intercept Depth: 42.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42.5-43
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1298)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 71
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 42.5 m
- To: 43 m
- Intercept Depth: 42.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:42.5-43
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 71 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 71

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1299)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.92
- Grade Unit: %
- Intercept: 0.5 m
- From: 43 m
- To: 43.5 m
- Intercept Depth: 43 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43-43.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.92 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.5 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.92

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1300)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 0.5 m
- From: 43 m
- To: 43.5 m
- Intercept Depth: 43 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43-43.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.29 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.29 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.29

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1301)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11.4
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 43 m
- To: 43.5 m
- Intercept Depth: 43 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43-43.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 11.4 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 5.7 g/t·m is below.

- Negative factor: 11.4 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 11.40

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1302)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 43 m
- To: 43.5 m
- Intercept Depth: 43 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43-43.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.06 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1303)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 43 m
- To: 43.5 m
- Intercept Depth: 43 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43-43.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1304)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 29
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 43 m
- To: 43.5 m
- Intercept Depth: 43 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43-43.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 29 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 29

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1305)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.86
- Grade Unit: %
- Intercept: 0.5 m
- From: 43.5 m
- To: 44 m
- Intercept Depth: 43.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43.5-44
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.86 % copper is strong against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.9 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 1.86 % copper is strong on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.86

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1306)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.35
- Grade Unit: %
- Intercept: 0.5 m
- From: 43.5 m
- To: 44 m
- Intercept Depth: 43.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43.5-44
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.35 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.35 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.35

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1307)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 43.5 m
- To: 44 m
- Intercept Depth: 43.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43.5-44
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 16.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 8.2 g/t·m is below.

- Negative factor: 16.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 16.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1308)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 43.5 m
- To: 44 m
- Intercept Depth: 43.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43.5-44
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.08 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1309)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 43.5 m
- To: 44 m
- Intercept Depth: 43.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43.5-44
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1310)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 43
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 43.5 m
- To: 44 m
- Intercept Depth: 43.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:43.5-44
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 43 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 43

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1311)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4.09
- Grade Unit: %
- Intercept: 0.5 m
- From: 44 m
- To: 44.5 m
- Intercept Depth: 44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44-44.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 4.09 % copper is exceptional against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 2.0 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 4.09 % copper is exceptional on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.09

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1312)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.49
- Grade Unit: %
- Intercept: 0.5 m
- From: 44 m
- To: 44.5 m
- Intercept Depth: 44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44-44.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.49 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.49 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.49

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1313)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 44
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 44 m
- To: 44.5 m
- Intercept Depth: 44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44-44.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 44 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 22.0 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 44.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1314)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.32
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 44 m
- To: 44.5 m
- Intercept Depth: 44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44-44.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.2 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.32

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1315)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 44 m
- To: 44.5 m
- Intercept Depth: 44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44-44.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1316)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 67
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 44 m
- To: 44.5 m
- Intercept Depth: 44 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44-44.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 67 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 67

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1317)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 2.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 44.5 m
- To: 45 m
- Intercept Depth: 44.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 2.01 % copper is strong against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.0 %·m is below \(grade alone is strong; the better of the two is used\).

- Positive factor: 2.01 % copper is strong on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1318)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.36
- Grade Unit: %
- Intercept: 0.5 m
- From: 44.5 m
- To: 45 m
- Intercept Depth: 44.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.36 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.36 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.36

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1319)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 44.5 m
- To: 45 m
- Intercept Depth: 44.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 16 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 8.0 g/t·m is below.

- Negative factor: 16 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 16.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1320)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 44.5 m
- To: 45 m
- Intercept Depth: 44.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1321)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 44.5 m
- To: 45 m
- Intercept Depth: 44.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1322)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 45
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 44.5 m
- To: 45 m
- Intercept Depth: 44.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:44.5-45
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 45 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 45

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1323)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 0.5 m
- From: 45 m
- To: 45.5 m
- Intercept Depth: 45 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45-45.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1324)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 45 m
- To: 45.5 m
- Intercept Depth: 45 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45-45.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1325)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 45 m
- To: 45.5 m
- Intercept Depth: 45 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45-45.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.7 g/t·m is below.

- Negative factor: 1.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1326)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 45 m
- To: 45.5 m
- Intercept Depth: 45 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45-45.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1327)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.06
- Grade Unit: %
- Intercept: 0.5 m
- From: 45 m
- To: 45.5 m
- Intercept Depth: 45 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45-45.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.06 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.06

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1328)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 45 m
- To: 45.5 m
- Intercept Depth: 45 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45-45.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1329)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 0.5 m
- From: 45.5 m
- To: 46 m
- Intercept Depth: 45.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45.5-46
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.22 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.22

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1330)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 45.5 m
- To: 46 m
- Intercept Depth: 45.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45.5-46
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1331)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 45.5 m
- To: 46 m
- Intercept Depth: 45.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45.5-46
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.8 g/t·m is below.

- Negative factor: 1.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.70

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1332)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 45.5 m
- To: 46 m
- Intercept Depth: 45.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45.5-46
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1333)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 45.5 m
- To: 46 m
- Intercept Depth: 45.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45.5-46
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1334)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 20
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 45.5 m
- To: 46 m
- Intercept Depth: 45.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:45.5-46
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 20 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 20

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1335)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 0.5 m
- From: 47 m
- To: 47.5 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47-47.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.23 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.23

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1336)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 47 m
- To: 47.5 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47-47.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1337)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 47 m
- To: 47.5 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47-47.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.8 g/t·m is below.

- Negative factor: 3.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.60

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1338)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 47 m
- To: 47.5 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47-47.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1339)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 47 m
- To: 47.5 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47-47.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1340)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 16
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 47 m
- To: 47.5 m
- Intercept Depth: 47 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47-47.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 16 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 16

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1341)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 0.5 m
- From: 47.5 m
- To: 48 m
- Intercept Depth: 47.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47.5-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.19 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.19

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1342)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 47.5 m
- To: 48 m
- Intercept Depth: 47.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47.5-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1343)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.7
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 47.5 m
- To: 48 m
- Intercept Depth: 47.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47.5-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.7 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.9 g/t·m is below.

- Negative factor: 3.7 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.70

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1344)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 47.5 m
- To: 48 m
- Intercept Depth: 47.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47.5-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1345)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 47.5 m
- To: 48 m
- Intercept Depth: 47.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47.5-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1346)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 19
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 47.5 m
- To: 48 m
- Intercept Depth: 47.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:47.5-48
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 19 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 19

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1347)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 1 m
- From: 79 m
- To: 80 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:79-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.12 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.12 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.12

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1348)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 1 m
- From: 79 m
- To: 80 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:79-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1349)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.6
- Grade Unit: g/t
- Intercept: 1 m
- From: 79 m
- To: 80 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:79-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 0.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.60

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1350)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 1 m
- From: 79 m
- To: 80 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:79-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1351)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 79 m
- To: 80 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:79-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1352)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 1 m
- From: 79 m
- To: 80 m
- Intercept Depth: 79 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:79-80
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1353)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 1 m
- From: 81 m
- To: 82 m
- Intercept Depth: 81 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:81-82
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1354)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 81 m
- To: 82 m
- Intercept Depth: 81 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:81-82
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1355)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 81 m
- To: 82 m
- Intercept Depth: 81 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:81-82
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1356)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 81 m
- To: 82 m
- Intercept Depth: 81 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:81-82
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1357)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 6
- Grade Unit: ppm
- Intercept: 1 m
- From: 81 m
- To: 82 m
- Intercept Depth: 81 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:81-82
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 6 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 6

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1358)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 1 m
- From: 82 m
- To: 83 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:82-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.13 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1359)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 82 m
- To: 83 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:82-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1360)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1 m
- From: 82 m
- To: 83 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:82-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1361)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 82 m
- To: 83 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:82-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1362)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10
- Grade Unit: ppm
- Intercept: 1 m
- From: 82 m
- To: 83 m
- Intercept Depth: 82 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:82-83
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 10 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1363)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1364)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1365)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1366)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1367)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 4
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 93 m
- To: 93.5 m
- Intercept Depth: 93 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93-93.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 4 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 4

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1368)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 0.5 m
- From: 93.5 m
- To: 94 m
- Intercept Depth: 93.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93.5-94
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.28 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1369)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 0.5 m
- From: 93.5 m
- To: 94 m
- Intercept Depth: 93.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93.5-94
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.09 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.09 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.09

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1370)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.6
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 93.5 m
- To: 94 m
- Intercept Depth: 93.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93.5-94
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.6 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.3 g/t·m is below.

- Negative factor: 0.6 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.60

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1371)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 93.5 m
- To: 94 m
- Intercept Depth: 93.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93.5-94
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1372)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 93.5 m
- To: 94 m
- Intercept Depth: 93.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93.5-94
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1373)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 18
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 93.5 m
- To: 94 m
- Intercept Depth: 93.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:93.5-94
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 18 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 18

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1374)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.64
- Grade Unit: %
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.64 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.64

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1375)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.08
- Grade Unit: %
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.08 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.08 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.08

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1376)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.7 g/t·m is below.

- Negative factor: 1.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1377)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1378)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1379)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 19
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 94 m
- To: 94.5 m
- Intercept Depth: 94 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94-94.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 19 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 19

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1380)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.56
- Grade Unit: %
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.56 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.3 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.56

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1381)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1382)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.3
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.3 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.7 g/t·m is below.

- Negative factor: 1.3 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1383)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1384)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1385)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 13
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 94.5 m
- To: 95 m
- Intercept Depth: 94.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:94.5-95
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 13 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 13

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1386)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.29
- Grade Unit: %
- Intercept: 0.5 m
- From: 95 m
- To: 95.5 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95-95.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.29 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.29 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.29

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1387)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 95 m
- To: 95.5 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95-95.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1388)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 95 m
- To: 95.5 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95-95.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1389)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.5 m
- From: 95 m
- To: 95.5 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95-95.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1390)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 15
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 95 m
- To: 95.5 m
- Intercept Depth: 95 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95-95.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 15 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1391)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.41
- Grade Unit: %
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.41 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.41

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1392)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.07 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.07 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.07

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1393)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 1.1
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 1.1 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.6 g/t·m is below.

- Negative factor: 1.1 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1394)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1395)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.00

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1396)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 26
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 95.5 m
- To: 96 m
- Intercept Depth: 95.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:95.5-96
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 26 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 26

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1397)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.3
- Grade Unit: %
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.3 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.3 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.30

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1398)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.02 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1399)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.8
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.8 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.4 g/t·m is below.

- Negative factor: 0.8 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.80

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1400)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1401)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1402)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 10
- Grade Unit: ppm
- Intercept: 0.5 m
- From: 96 m
- To: 96.5 m
- Intercept Depth: 96 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:96-96.5
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 10 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 10

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1403)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.22
- Grade Unit: %
- Intercept: 1 m
- From: 117 m
- To: 118 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:117-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.22 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.22

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1404)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.15
- Grade Unit: %
- Intercept: 1 m
- From: 117 m
- To: 118 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:117-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.15 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.15 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.15

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1405)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 3.5
- Grade Unit: g/t
- Intercept: 1 m
- From: 117 m
- To: 118 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:117-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 3.5 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 3.5 g/t·m is below.

- Negative factor: 3.5 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.50

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1406)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.05
- Grade Unit: g/t
- Intercept: 1 m
- From: 117 m
- To: 118 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:117-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.05 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1407)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 117 m
- To: 118 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:117-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1408)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 11
- Grade Unit: ppm
- Intercept: 1 m
- From: 117 m
- To: 118 m
- Intercept Depth: 117 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:117-118
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 11 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 11

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1409)

Rush target · copper

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: copper
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.11
- Grade Unit: %
- Intercept: 1 m
- From: 118 m
- To: 119 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:118-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.11 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.11 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.11

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1410)

Rush target · zinc

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: zinc
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 1 m
- From: 118 m
- To: 119 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:118-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.03 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1411)

Rush target · silver

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: silver
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.9
- Grade Unit: g/t
- Intercept: 1 m
- From: 118 m
- To: 119 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:118-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.9 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.9 g/t·m is below.

- Negative factor: 0.9 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.90

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1412)

Rush target · gold

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: gold
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.02
- Grade Unit: g/t
- Intercept: 1 m
- From: 118 m
- To: 119 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:118-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.02 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.02 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.02

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1413)

Rush target · lead

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: lead
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1 m
- From: 118 m
- To: 119 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:118-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Rush-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/ramp-metals-confirms-vms-discovery-at-rush-target--c13ee5ed-f94e-47db-901f-bda5ee887890#fact-drill-facts-1414)

Rush target · cobalt

#### Identity

- Hole ID: Rush-010
- Project: Rush target
- Commodity: cobalt
- Region: canada\_sk
- Reported Region: canada\_sk
- Ticker: RAMP

#### Geometry

- Grade: 26
- Grade Unit: ppm
- Intercept: 1 m
- From: 118 m
- To: 119 m
- Intercept Depth: 118 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Rush-010:118-119
- Mining Method: unknown

#### QA/QC

- QA/QC Disclosed: Yes
- Lab Certified: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Metal Equivalent

- Assumptions Disclosed: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2025-08-05T00:00:00.000Z

Reasoning: Expanded from assay table: 26 ppm cobalt, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the cobalt rubric unit %; not scored.

Evidence · table

> 26

Context: Rush-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
