SAGA Metals Reports Assays from R-0064 to R-0071 with Intercepts Including 52.52% Fe2O3, 7.58% TiO2, 0.428% V2O5 from 2026 Drilling at Radar Critical Minerals Project in Labrador

Original announcement by tmx on

Company
SAGA Metals Corp.
Ticker
SAGA
Exchange
TSX
Region
Labrador, Canada
Primary commodity
Iron ore
Secondary commodities
Titanium, Vanadium
Document categories
Drill results
Extracted
2026-09-12 22:23:51 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

SAGA Metals Corp. reported new assay results from eight diamond drill holes (R-0064 to R-0071) at its Radar Critical Minerals Project in Labrador, Canada, as part of an ongoing maiden Mineral Resource Estimate program. The results show consistent broad intercepts of high-grade iron, titanium, and vanadium, including up to 52.52% Fe2O3, 7.58% TiO2, and 0.428% V2O5 over 23.3 meters in hole R-0066. These new assays, combined with previously reported results, continue to define a large, consistent oxide system, supporting the potential for a sizable mineral resource.

Reasoning: The new drill results from R-0064 to R-0071 confirm consistent, broad, high-grade iron, titanium, and vanadium mineralization, validating the project's potential for a significant maiden Mineral Resource Estimate. The results are consistent with previous drilling and define the ore body well.

Positive factors

  • Consistent broad intercepts
  • High grades for iron, titanium, and vanadium
  • Definition of high-grade core and ore body limits
  • Ongoing maiden MRE program
  • Critical minerals project
  • Good infrastructure (road access, deep-water port, hydro-electric power)

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 149

Extracted facts

Stored fact records: 149. Some facts used in scoring do not have a stored record.

Drill Results (149)

R-0008iron_oreGrade: 36.21Grade Unit: %Intercept: 269.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0008
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
36.21
Grade Unit
%
Intercept
269.4 m
True Width
261.2 m
From
3.4 m
To
272 m
Hole Depth
272 m
Intercept Depth
3.4 m

Classification

Sample Type
drill
Group ID
R-0008:3.4-272

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“36.21”

Context: 269.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 261.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0008titaniumGrade: 6.57Grade Unit: %Intercept: 269.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0008
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.57
Grade Unit
%
Intercept
269.4 m
True Width
261.2 m
From
3.4 m
To
272 m
Hole Depth
272 m
Intercept Depth
3.4 m

Classification

Sample Type
drill
Group ID
R-0008:3.4-272

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“6.57”

Context: 269.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 261.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0008vanadiumGrade: 0.244Grade Unit: %Intercept: 269.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0008
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.244
Grade Unit
%
Intercept
269.4 m
True Width
261.2 m
From
3.4 m
To
272 m
Hole Depth
272 m
Intercept Depth
3.4 m

Classification

Sample Type
drill
Group ID
R-0008:3.4-272

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“0.244”

Context: 269.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 261.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0008iron_oreGrade: 46.15Grade Unit: %Intercept: 68.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0008
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
46.15
Grade Unit
%
Intercept
68.3 m
True Width
66.2 m
From
170 m
To
237.6 m
Hole Depth
272 m
Intercept Depth
3.4 m

Classification

Sample Type
drill
Group ID
R-0008:170-237.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“46.15”

Context: 68.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 66.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0008titaniumGrade: 9.21Grade Unit: %Intercept: 68.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0008
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
9.21
Grade Unit
%
Intercept
68.3 m
True Width
66.2 m
From
170 m
To
237.6 m
Hole Depth
272 m
Intercept Depth
3.4 m

Classification

Sample Type
drill
Group ID
R-0008:170-237.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“9.21”

Context: 68.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 66.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0008vanadiumGrade: 0.311Grade Unit: %Intercept: 68.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0008
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.311
Grade Unit
%
Intercept
68.3 m
True Width
66.2 m
From
170 m
To
237.6 m
Hole Depth
272 m
Intercept Depth
3.4 m

Classification

Sample Type
drill
Group ID
R-0008:170-237.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.311”

Context: 68.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 66.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0009iron_oreGrade: 39.75Grade Unit: %Intercept: 296.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0009
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
39.75
Grade Unit
%
Intercept
296.5 m
True Width
286.9 m
From
2.5 m
To
299 m
Hole Depth
299 m
Intercept Depth
2.5 m

Classification

Sample Type
drill
Group ID
R-0009:2.5-299

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a very broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Very broad intercept length
  • Good true width

Evidence · table

“39.75”

Context: 296.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 286.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0009titaniumGrade: 7.46Grade Unit: %Intercept: 296.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0009
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.46
Grade Unit
%
Intercept
296.5 m
True Width
286.9 m
From
2.5 m
To
299 m
Hole Depth
299 m
Intercept Depth
2.5 m

Classification

Sample Type
drill
Group ID
R-0009:2.5-299

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a very broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Very broad intercept length
  • Good true width

Evidence · table

“7.46”

Context: 296.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 286.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0009vanadiumGrade: 0.25Grade Unit: %Intercept: 296.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0009
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.25
Grade Unit
%
Intercept
296.5 m
True Width
286.9 m
From
2.5 m
To
299 m
Hole Depth
299 m
Intercept Depth
2.5 m

Classification

Sample Type
drill
Group ID
R-0009:2.5-299

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a very broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Very broad intercept length
  • Good true width

Evidence · table

“0.250”

Context: 296.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 286.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0009iron_oreGrade: 50.67Grade Unit: %Intercept: 87.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0009
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
50.67
Grade Unit
%
Intercept
87.2 m
True Width
84.4 m
From
94 m
To
181.2 m
Hole Depth
299 m
Intercept Depth
2.5 m

Classification

Sample Type
drill
Group ID
R-0009:94-181.2

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Significant intercept length and true width

Evidence · table

“50.67”

Context: 87.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 84.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0009titaniumGrade: 10.15Grade Unit: %Intercept: 87.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0009
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
10.15
Grade Unit
%
Intercept
87.2 m
True Width
84.4 m
From
94 m
To
181.2 m
Hole Depth
299 m
Intercept Depth
2.5 m

Classification

Sample Type
drill
Group ID
R-0009:94-181.2

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Significant intercept length and true width

Evidence · table

“10.15”

Context: 87.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 84.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0009vanadiumGrade: 0.339Grade Unit: %Intercept: 87.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0009
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.339
Grade Unit
%
Intercept
87.2 m
True Width
84.4 m
From
94 m
To
181.2 m
Hole Depth
299 m
Intercept Depth
2.5 m

Classification

Sample Type
drill
Group ID
R-0009:94-181.2

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Significant intercept length and true width

Evidence · table

“0.339”

Context: 87.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 84.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0010iron_oreGrade: 50.03Grade Unit: %Intercept: 135.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0010
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
50.03
Grade Unit
%
Intercept
135.5 m
True Width
121.7 m
From
1.5 m
To
137 m
Hole Depth
251 m
Intercept Depth
1.5 m

Classification

Sample Type
drill
Group ID
R-0010:1.5-137

Location

Azimuth
0 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a broad width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Broad intercept length and true width

Evidence · table

“50.03”

Context: 135.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 121.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0010titaniumGrade: 7.87Grade Unit: %Intercept: 135.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0010
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.87
Grade Unit
%
Intercept
135.5 m
True Width
121.7 m
From
1.5 m
To
137 m
Hole Depth
251 m
Intercept Depth
1.5 m

Classification

Sample Type
drill
Group ID
R-0010:1.5-137

Location

Azimuth
0 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a broad width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Broad intercept length and true width

Evidence · table

“7.87”

Context: 135.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 121.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0010vanadiumGrade: 0.352Grade Unit: %Intercept: 135.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0010
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.352
Grade Unit
%
Intercept
135.5 m
True Width
121.7 m
From
1.5 m
To
137 m
Hole Depth
251 m
Intercept Depth
1.5 m

Classification

Sample Type
drill
Group ID
R-0010:1.5-137

Location

Azimuth
0 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a broad width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Broad intercept length and true width

Evidence · table

“0.352”

Context: 135.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 121.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0011iron_oreGrade: 39.49Grade Unit: %Intercept: 95.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0011
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
39.49
Grade Unit
%
Intercept
95.2 m
True Width
50.8 m
From
58.1 m
To
153.3 m
Hole Depth
251 m
Intercept Depth
46.46 m

Classification

Sample Type
drill
Group ID
R-0011:58.1-153.3

Location

Azimuth
0 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“39.49”

Context: 95.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 50.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0011titaniumGrade: 6.49Grade Unit: %Intercept: 95.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0011
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.49
Grade Unit
%
Intercept
95.2 m
True Width
50.8 m
From
58.1 m
To
153.3 m
Hole Depth
251 m
Intercept Depth
46.46 m

Classification

Sample Type
drill
Group ID
R-0011:58.1-153.3

Location

Azimuth
0 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“6.49”

Context: 95.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 50.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0011vanadiumGrade: 0.222Grade Unit: %Intercept: 95.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0011
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.222
Grade Unit
%
Intercept
95.2 m
True Width
50.8 m
From
58.1 m
To
153.3 m
Hole Depth
251 m
Intercept Depth
46.46 m

Classification

Sample Type
drill
Group ID
R-0011:58.1-153.3

Location

Azimuth
0 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“0.222”

Context: 95.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 50.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0012iron_oreGrade: 27.39Grade Unit: %Intercept: 75.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0012
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
27.39
Grade Unit
%
Intercept
75.2 m
True Width
39.6 m
From
3.8 m
To
79 m
Hole Depth
194 m
Intercept Depth
3.9 m

Classification

Sample Type
drill
Group ID
R-0012:3.8-79

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept length of iron mineralization, but the grade is lower and it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“27.39”

Context: 75.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 39.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0012titaniumGrade: 4.87Grade Unit: %Intercept: 75.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0012
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
4.87
Grade Unit
%
Intercept
75.2 m
True Width
39.6 m
From
3.8 m
To
79 m
Hole Depth
194 m
Intercept Depth
3.9 m

Classification

Sample Type
drill
Group ID
R-0012:3.8-79

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept length of titanium mineralization, but the grade is lower and it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“4.87”

Context: 75.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 39.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0012vanadiumGrade: 0.116Grade Unit: %Intercept: 75.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0012
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.116
Grade Unit
%
Intercept
75.2 m
True Width
39.6 m
From
3.8 m
To
79 m
Hole Depth
194 m
Intercept Depth
3.9 m

Classification

Sample Type
drill
Group ID
R-0012:3.8-79

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept length of vanadium mineralization, but the grade is lower and it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“0.116”

Context: 75.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 39.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0013iron_oreGrade: 37.08Grade Unit: %Intercept: 111.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0013
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
37.08
Grade Unit
%
Intercept
111.5 m
True Width
97.9 m
From
9.5 m
To
121 m
Hole Depth
251 m
Intercept Depth
9.5 m

Classification

Sample Type
drill
Group ID
R-0013:9.5-121

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“37.08”

Context: 111.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 97.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0013titaniumGrade: 5.14Grade Unit: %Intercept: 111.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0013
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.14
Grade Unit
%
Intercept
111.5 m
True Width
97.9 m
From
9.5 m
To
121 m
Hole Depth
251 m
Intercept Depth
9.5 m

Classification

Sample Type
drill
Group ID
R-0013:9.5-121

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“5.14”

Context: 111.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 97.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0013vanadiumGrade: 0.242Grade Unit: %Intercept: 111.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0013
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.242
Grade Unit
%
Intercept
111.5 m
True Width
97.9 m
From
9.5 m
To
121 m
Hole Depth
251 m
Intercept Depth
9.5 m

Classification

Sample Type
drill
Group ID
R-0013:9.5-121

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“0.242”

Context: 111.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 97.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0014iron_oreGrade: 36.17Grade Unit: %Intercept: 41.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0014
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
36.17
Grade Unit
%
Intercept
41.2 m
True Width
14.9 m
From
8.8 m
To
50 m
Hole Depth
272 m
Intercept Depth
8.8 m

Classification

Sample Type
drill
Group ID
R-0014:8.8-50

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“36.17”

Context: 41.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 14.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0014titaniumGrade: 6.36Grade Unit: %Intercept: 41.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0014
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.36
Grade Unit
%
Intercept
41.2 m
True Width
14.9 m
From
8.8 m
To
50 m
Hole Depth
272 m
Intercept Depth
8.8 m

Classification

Sample Type
drill
Group ID
R-0014:8.8-50

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“6.36”

Context: 41.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 14.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0014vanadiumGrade: 0.188Grade Unit: %Intercept: 41.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0014
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.188
Grade Unit
%
Intercept
41.2 m
True Width
14.9 m
From
8.8 m
To
50 m
Hole Depth
272 m
Intercept Depth
8.8 m

Classification

Sample Type
drill
Group ID
R-0014:8.8-50

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“0.188”

Context: 41.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 14.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0015iron_oreGrade: 38.56Grade Unit: %Intercept: 100.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0015
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
38.56
Grade Unit
%
Intercept
100.7 m
True Width
88.9 m
From
73.3 m
To
174 m
Hole Depth
263 m
Intercept Depth
77 m

Classification

Sample Type
drill
Group ID
R-0015:73.3-174

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“38.56”

Context: 100.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 88.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0015titaniumGrade: 6.8Grade Unit: %Intercept: 100.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0015
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.8
Grade Unit
%
Intercept
100.7 m
True Width
88.9 m
From
73.3 m
To
174 m
Hole Depth
263 m
Intercept Depth
77 m

Classification

Sample Type
drill
Group ID
R-0015:73.3-174

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“6.80”

Context: 100.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 88.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0015vanadiumGrade: 0.229Grade Unit: %Intercept: 100.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0015
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.229
Grade Unit
%
Intercept
100.7 m
True Width
88.9 m
From
73.3 m
To
174 m
Hole Depth
263 m
Intercept Depth
77 m

Classification

Sample Type
drill
Group ID
R-0015:73.3-174

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“0.229”

Context: 100.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 88.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0016iron_oreGrade: 52.05Grade Unit: %Intercept: 50.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0016
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
52.05
Grade Unit
%
Intercept
50.6 m
True Width
47.1 m
From
44 m
To
94.6 m
Hole Depth
206 m
Intercept Depth
44 m

Classification

Sample Type
drill
Group ID
R-0016:44-94.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“52.05”

Context: 50.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 47.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0016titaniumGrade: 7.21Grade Unit: %Intercept: 50.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0016
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.21
Grade Unit
%
Intercept
50.6 m
True Width
47.1 m
From
44 m
To
94.6 m
Hole Depth
206 m
Intercept Depth
44 m

Classification

Sample Type
drill
Group ID
R-0016:44-94.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“7.21”

Context: 50.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 47.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0016vanadiumGrade: 0.375Grade Unit: %Intercept: 50.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0016
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.375
Grade Unit
%
Intercept
50.6 m
True Width
47.1 m
From
44 m
To
94.6 m
Hole Depth
206 m
Intercept Depth
44 m

Classification

Sample Type
drill
Group ID
R-0016:44-94.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.375”

Context: 50.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 47.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0017iron_oreGrade: 51.86Grade Unit: %Intercept: 90 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0017
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
51.86
Grade Unit
%
Intercept
90 m
True Width
73 m
From
50.6 m
To
140.6 m
Hole Depth
161 m
Intercept Depth
50.6 m

Classification

Sample Type
drill
Group ID
R-0017:50.6-140.6

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Significant intercept length and true width

Evidence · table

“51.86”

Context: 90.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 73

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0017titaniumGrade: 6.76Grade Unit: %Intercept: 90 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0017
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.76
Grade Unit
%
Intercept
90 m
True Width
73 m
From
50.6 m
To
140.6 m
Hole Depth
161 m
Intercept Depth
50.6 m

Classification

Sample Type
drill
Group ID
R-0017:50.6-140.6

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Significant intercept length and true width

Evidence · table

“6.76”

Context: 90.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 73

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0017vanadiumGrade: 0.417Grade Unit: %Intercept: 90 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0017
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.417
Grade Unit
%
Intercept
90 m
True Width
73 m
From
50.6 m
To
140.6 m
Hole Depth
161 m
Intercept Depth
50.6 m

Classification

Sample Type
drill
Group ID
R-0017:50.6-140.6

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Significant intercept length and true width

Evidence · table

“0.417”

Context: 90.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 73

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0018iron_oreGrade: 42.64Grade Unit: %Intercept: 70.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0018
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
42.64
Grade Unit
%
Intercept
70.3 m
True Width
44.1 m
From
44.7 m
To
115 m
Hole Depth
188 m
Intercept Depth
44.7 m

Classification

Sample Type
drill
Group ID
R-0018:44.7-115

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“42.64”

Context: 70.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 44.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0018titaniumGrade: 5.66Grade Unit: %Intercept: 70.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0018
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.66
Grade Unit
%
Intercept
70.3 m
True Width
44.1 m
From
44.7 m
To
115 m
Hole Depth
188 m
Intercept Depth
44.7 m

Classification

Sample Type
drill
Group ID
R-0018:44.7-115

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“5.66”

Context: 70.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 44.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0018vanadiumGrade: 0.288Grade Unit: %Intercept: 70.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0018
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.288
Grade Unit
%
Intercept
70.3 m
True Width
44.1 m
From
44.7 m
To
115 m
Hole Depth
188 m
Intercept Depth
44.7 m

Classification

Sample Type
drill
Group ID
R-0018:44.7-115

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“0.288”

Context: 70.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 44.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0019iron_oreGrade: 49.51Grade Unit: %Intercept: 45.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0019
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
49.51
Grade Unit
%
Intercept
45.7 m
True Width
41.6 m
From
66.6 m
To
112.3 m
Hole Depth
182 m
Intercept Depth
66.6 m

Classification

Sample Type
drill
Group ID
R-0019:66.6-112.3

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“49.51”

Context: 45.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 41.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0019titaniumGrade: 6.56Grade Unit: %Intercept: 45.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0019
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.56
Grade Unit
%
Intercept
45.7 m
True Width
41.6 m
From
66.6 m
To
112.3 m
Hole Depth
182 m
Intercept Depth
66.6 m

Classification

Sample Type
drill
Group ID
R-0019:66.6-112.3

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“6.56”

Context: 45.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 41.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0019vanadiumGrade: 0.374Grade Unit: %Intercept: 45.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0019
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.374
Grade Unit
%
Intercept
45.7 m
True Width
41.6 m
From
66.6 m
To
112.3 m
Hole Depth
182 m
Intercept Depth
66.6 m

Classification

Sample Type
drill
Group ID
R-0019:66.6-112.3

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.374”

Context: 45.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 41.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0020iron_oreGrade: 37.62Grade Unit: %Intercept: 40.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0020
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
37.62
Grade Unit
%
Intercept
40.7 m
True Width
31.1 m
From
87.3 m
To
128 m
Hole Depth
206 m
Intercept Depth
50.8 m

Classification

Sample Type
drill
Group ID
R-0020:87.3-128

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“37.62”

Context: 40.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 31.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0020titaniumGrade: 4.93Grade Unit: %Intercept: 40.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0020
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
4.93
Grade Unit
%
Intercept
40.7 m
True Width
31.1 m
From
87.3 m
To
128 m
Hole Depth
206 m
Intercept Depth
50.8 m

Classification

Sample Type
drill
Group ID
R-0020:87.3-128

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“4.93”

Context: 40.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 31.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0020vanadiumGrade: 0.239Grade Unit: %Intercept: 40.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0020
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.239
Grade Unit
%
Intercept
40.7 m
True Width
31.1 m
From
87.3 m
To
128 m
Hole Depth
206 m
Intercept Depth
50.8 m

Classification

Sample Type
drill
Group ID
R-0020:87.3-128

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“0.239”

Context: 40.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 31.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0021iron_oreGrade: 53.18Grade Unit: %Intercept: 31.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0021
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
53.18
Grade Unit
%
Intercept
31.4 m
True Width
16.5 m
From
96 m
To
127.4 m
Hole Depth
152 m
Intercept Depth
81.3 m

Classification

Sample Type
drill
Group ID
R-0021:96-127.4

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length

Evidence · table

“53.18”

Context: 31.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0021titaniumGrade: 7.08Grade Unit: %Intercept: 31.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0021
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.08
Grade Unit
%
Intercept
31.4 m
True Width
16.5 m
From
96 m
To
127.4 m
Hole Depth
152 m
Intercept Depth
81.3 m

Classification

Sample Type
drill
Group ID
R-0021:96-127.4

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length

Evidence · table

“7.08”

Context: 31.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0021vanadiumGrade: 0.414Grade Unit: %Intercept: 31.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0021
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.414
Grade Unit
%
Intercept
31.4 m
True Width
16.5 m
From
96 m
To
127.4 m
Hole Depth
152 m
Intercept Depth
81.3 m

Classification

Sample Type
drill
Group ID
R-0021:96-127.4

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length

Evidence · table

“0.414”

Context: 31.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 16.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0022iron_oreGrade: 49.4Grade Unit: %Intercept: 30.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0022
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
49.4
Grade Unit
%
Intercept
30.6 m
True Width
28.6 m
From
62 m
To
92.6 m
Hole Depth
149 m
Intercept Depth
22.5 m

Classification

Sample Type
drill
Group ID
R-0022:62-92.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“49.4”

Context: 30.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 28.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0022titaniumGrade: 6.61Grade Unit: %Intercept: 30.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0022
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.61
Grade Unit
%
Intercept
30.6 m
True Width
28.6 m
From
62 m
To
92.6 m
Hole Depth
149 m
Intercept Depth
22.5 m

Classification

Sample Type
drill
Group ID
R-0022:62-92.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“6.61”

Context: 30.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 28.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0022vanadiumGrade: 0.373Grade Unit: %Intercept: 30.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0022
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.373
Grade Unit
%
Intercept
30.6 m
True Width
28.6 m
From
62 m
To
92.6 m
Hole Depth
149 m
Intercept Depth
22.5 m

Classification

Sample Type
drill
Group ID
R-0022:62-92.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.373”

Context: 30.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 28.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0023iron_oreGrade: 45.5Grade Unit: %Intercept: 86 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0023
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
45.5
Grade Unit
%
Intercept
86 m
True Width
54 m
From
100.5 m
To
186.5 m
Hole Depth
272 m
Intercept Depth
100.5 m

Classification

Sample Type
drill
Group ID
R-0023:100.5-186.5

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“45.5”

Context: 86.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 54

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0023titaniumGrade: 5.5Grade Unit: %Intercept: 86 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0023
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.5
Grade Unit
%
Intercept
86 m
True Width
54 m
From
100.5 m
To
186.5 m
Hole Depth
272 m
Intercept Depth
100.5 m

Classification

Sample Type
drill
Group ID
R-0023:100.5-186.5

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“5.5”

Context: 86.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 54

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0023vanadiumGrade: 0.367Grade Unit: %Intercept: 86 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0023
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.367
Grade Unit
%
Intercept
86 m
True Width
54 m
From
100.5 m
To
186.5 m
Hole Depth
272 m
Intercept Depth
100.5 m

Classification

Sample Type
drill
Group ID
R-0023:100.5-186.5

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“0.367”

Context: 86.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 54

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0024iron_oreGrade: 49.08Grade Unit: %Intercept: 91 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0024
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
49.08
Grade Unit
%
Intercept
91 m
True Width
58.7 m
From
112 m
To
203 m
Hole Depth
248 m
Intercept Depth
108.9 m

Classification

Sample Type
drill
Group ID
R-0024:112-203

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Significant intercept length and true width

Evidence · table

“49.08”

Context: 91.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 58.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0024titaniumGrade: 6.23Grade Unit: %Intercept: 91 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0024
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.23
Grade Unit
%
Intercept
91 m
True Width
58.7 m
From
112 m
To
203 m
Hole Depth
248 m
Intercept Depth
108.9 m

Classification

Sample Type
drill
Group ID
R-0024:112-203

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Significant intercept length and true width

Evidence · table

“6.23”

Context: 91.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 58.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0024vanadiumGrade: 0.39Grade Unit: %Intercept: 91 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0024
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.39
Grade Unit
%
Intercept
91 m
True Width
58.7 m
From
112 m
To
203 m
Hole Depth
248 m
Intercept Depth
108.9 m

Classification

Sample Type
drill
Group ID
R-0024:112-203

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Significant intercept length and true width

Evidence · table

“0.39”

Context: 91.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 58.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0024iron_oreGrade: 54.2Grade Unit: %Intercept: 44 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0024
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
54.2
Grade Unit
%
Intercept
44 m
True Width
28.4 m
From
142 m
To
186 m
Hole Depth
248 m
Intercept Depth
108.9 m

Classification

Sample Type
drill
Group ID
R-0024:142-186

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“54.2”

Context: 44.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 28.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0024titaniumGrade: 7.07Grade Unit: %Intercept: 44 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0024
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.07
Grade Unit
%
Intercept
44 m
True Width
28.4 m
From
142 m
To
186 m
Hole Depth
248 m
Intercept Depth
108.9 m

Classification

Sample Type
drill
Group ID
R-0024:142-186

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“7.07”

Context: 44.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 28.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0024vanadiumGrade: 0.443Grade Unit: %Intercept: 44 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0024
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.443
Grade Unit
%
Intercept
44 m
True Width
28.4 m
From
142 m
To
186 m
Hole Depth
248 m
Intercept Depth
108.9 m

Classification

Sample Type
drill
Group ID
R-0024:142-186

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.443”

Context: 44.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 28.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0025iron_oreGrade: 41.36Grade Unit: %Intercept: 81.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0025
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
41.36
Grade Unit
%
Intercept
81.7 m
True Width
58.5 m
From
141.3 m
To
223 m
Hole Depth
275 m
Intercept Depth
123 m

Classification

Sample Type
drill
Group ID
R-0025:141.3-223

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“41.36”

Context: 81.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 58.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0025titaniumGrade: 5.18Grade Unit: %Intercept: 81.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0025
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.18
Grade Unit
%
Intercept
81.7 m
True Width
58.5 m
From
141.3 m
To
223 m
Hole Depth
275 m
Intercept Depth
123 m

Classification

Sample Type
drill
Group ID
R-0025:141.3-223

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“5.18”

Context: 81.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 58.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0025vanadiumGrade: 0.309Grade Unit: %Intercept: 81.7 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0025
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.309
Grade Unit
%
Intercept
81.7 m
True Width
58.5 m
From
141.3 m
To
223 m
Hole Depth
275 m
Intercept Depth
123 m

Classification

Sample Type
drill
Group ID
R-0025:141.3-223

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“0.309”

Context: 81.7

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 58.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0025iron_oreGrade: 47.38Grade Unit: %Intercept: 33 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0025
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
47.38
Grade Unit
%
Intercept
33 m
True Width
23.7 m
From
168 m
To
201 m
Hole Depth
275 m
Intercept Depth
123 m

Classification

Sample Type
drill
Group ID
R-0025:168-201

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“47.38”

Context: 33.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 23.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0025titaniumGrade: 6.01Grade Unit: %Intercept: 33 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0025
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.01
Grade Unit
%
Intercept
33 m
True Width
23.7 m
From
168 m
To
201 m
Hole Depth
275 m
Intercept Depth
123 m

Classification

Sample Type
drill
Group ID
R-0025:168-201

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“6.01”

Context: 33.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 23.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0025vanadiumGrade: 0.384Grade Unit: %Intercept: 33 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0025
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.384
Grade Unit
%
Intercept
33 m
True Width
23.7 m
From
168 m
To
201 m
Hole Depth
275 m
Intercept Depth
123 m

Classification

Sample Type
drill
Group ID
R-0025:168-201

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.384”

Context: 33.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 23.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0026iron_oreGrade: 38.16Grade Unit: %Intercept: 47.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0026
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
38.16
Grade Unit
%
Intercept
47.3 m
True Width
27.7 m
From
141.7 m
To
189 m
Hole Depth
302 m
Intercept Depth
108.8 m

Classification

Sample Type
drill
Group ID
R-0026:141.7-189

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“38.16”

Context: 47.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 27.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0026titaniumGrade: 4.65Grade Unit: %Intercept: 47.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0026
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
4.65
Grade Unit
%
Intercept
47.3 m
True Width
27.7 m
From
141.7 m
To
189 m
Hole Depth
302 m
Intercept Depth
108.8 m

Classification

Sample Type
drill
Group ID
R-0026:141.7-189

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“4.65”

Context: 47.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 27.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0026vanadiumGrade: 0.288Grade Unit: %Intercept: 47.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0026
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.288
Grade Unit
%
Intercept
47.3 m
True Width
27.7 m
From
141.7 m
To
189 m
Hole Depth
302 m
Intercept Depth
108.8 m

Classification

Sample Type
drill
Group ID
R-0026:141.7-189

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“0.288”

Context: 47.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 27.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0026iron_oreGrade: 52.39Grade Unit: %Intercept: 20.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0026
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
52.39
Grade Unit
%
Intercept
20.5 m
True Width
12 m
From
110.9 m
To
131.4 m
Hole Depth
302 m
Intercept Depth
108.8 m

Classification

Sample Type
drill
Group ID
R-0026:110.9-131.4

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“52.39”

Context: 20.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 12

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0026titaniumGrade: 6.55Grade Unit: %Intercept: 20.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0026
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.55
Grade Unit
%
Intercept
20.5 m
True Width
12 m
From
110.9 m
To
131.4 m
Hole Depth
302 m
Intercept Depth
108.8 m

Classification

Sample Type
drill
Group ID
R-0026:110.9-131.4

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“6.55”

Context: 20.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 12

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0026vanadiumGrade: 0.449Grade Unit: %Intercept: 20.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0026
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.449
Grade Unit
%
Intercept
20.5 m
True Width
12 m
From
110.9 m
To
131.4 m
Hole Depth
302 m
Intercept Depth
108.8 m

Classification

Sample Type
drill
Group ID
R-0026:110.9-131.4

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.449”

Context: 20.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 12

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0027iron_oreGrade: 42.74Grade Unit: %Intercept: 80.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0027
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
42.74
Grade Unit
%
Intercept
80.8 m
True Width
63.4 m
From
81.2 m
To
162 m
Hole Depth
221 m
Intercept Depth
81.3 m

Classification

Sample Type
drill
Group ID
R-0027:81.2-162

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“42.74”

Context: 80.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 63.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0027titaniumGrade: 5.18Grade Unit: %Intercept: 80.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0027
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.18
Grade Unit
%
Intercept
80.8 m
True Width
63.4 m
From
81.2 m
To
162 m
Hole Depth
221 m
Intercept Depth
81.3 m

Classification

Sample Type
drill
Group ID
R-0027:81.2-162

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“5.18”

Context: 80.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 63.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0027vanadiumGrade: 0.32Grade Unit: %Intercept: 80.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0027
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.32
Grade Unit
%
Intercept
80.8 m
True Width
63.4 m
From
81.2 m
To
162 m
Hole Depth
221 m
Intercept Depth
81.3 m

Classification

Sample Type
drill
Group ID
R-0027:81.2-162

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“0.320”

Context: 80.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 63.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0028iron_oreGrade: 42.39Grade Unit: %Intercept: 105.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0028
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
42.39
Grade Unit
%
Intercept
105.3 m
True Width
54.5 m
From
105.7 m
To
211 m
Hole Depth
230 m
Intercept Depth
105.1 m

Classification

Sample Type
drill
Group ID
R-0028:105.7-211

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Broad intercept length

Evidence · table

“42.39”

Context: 105.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 54.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0028titaniumGrade: 5.4Grade Unit: %Intercept: 105.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0028
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.4
Grade Unit
%
Intercept
105.3 m
True Width
54.5 m
From
105.7 m
To
211 m
Hole Depth
230 m
Intercept Depth
105.1 m

Classification

Sample Type
drill
Group ID
R-0028:105.7-211

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Broad intercept length

Evidence · table

“5.40”

Context: 105.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 54.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0028vanadiumGrade: 0.306Grade Unit: %Intercept: 105.3 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0028
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.306
Grade Unit
%
Intercept
105.3 m
True Width
54.5 m
From
105.7 m
To
211 m
Hole Depth
230 m
Intercept Depth
105.1 m

Classification

Sample Type
drill
Group ID
R-0028:105.7-211

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Broad intercept length

Evidence · table

“0.306”

Context: 105.3

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 54.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0028iron_oreGrade: 49.43Grade Unit: %Intercept: 38 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0028
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
49.43
Grade Unit
%
Intercept
38 m
True Width
19.7 m
From
144 m
To
182 m
Hole Depth
230 m
Intercept Depth
105.1 m

Classification

Sample Type
drill
Group ID
R-0028:144-182

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length

Evidence · table

“49.43”

Context: 38.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 19.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0028titaniumGrade: 6.5Grade Unit: %Intercept: 38 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0028
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.5
Grade Unit
%
Intercept
38 m
True Width
19.7 m
From
144 m
To
182 m
Hole Depth
230 m
Intercept Depth
105.1 m

Classification

Sample Type
drill
Group ID
R-0028:144-182

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length

Evidence · table

“6.50”

Context: 38.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 19.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0028vanadiumGrade: 0.382Grade Unit: %Intercept: 38 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0028
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.382
Grade Unit
%
Intercept
38 m
True Width
19.7 m
From
144 m
To
182 m
Hole Depth
230 m
Intercept Depth
105.1 m

Classification

Sample Type
drill
Group ID
R-0028:144-182

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length

Evidence · table

“0.382”

Context: 38.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 19.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0029iron_oreGrade: 44.41Grade Unit: %Intercept: 106.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0029
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
44.41
Grade Unit
%
Intercept
106.8 m
True Width
95.5 m
From
65.2 m
To
172 m
Hole Depth
214 m
Intercept Depth
65.2 m

Classification

Sample Type
drill
Group ID
R-0029:65.2-172

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“44.41”

Context: 106.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 95.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0029titaniumGrade: 5.36Grade Unit: %Intercept: 106.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0029
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.36
Grade Unit
%
Intercept
106.8 m
True Width
95.5 m
From
65.2 m
To
172 m
Hole Depth
214 m
Intercept Depth
65.2 m

Classification

Sample Type
drill
Group ID
R-0029:65.2-172

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“5.36”

Context: 106.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 95.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0029vanadiumGrade: 0.341Grade Unit: %Intercept: 106.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0029
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.341
Grade Unit
%
Intercept
106.8 m
True Width
95.5 m
From
65.2 m
To
172 m
Hole Depth
214 m
Intercept Depth
65.2 m

Classification

Sample Type
drill
Group ID
R-0029:65.2-172

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“0.341”

Context: 106.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 95.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0029iron_oreGrade: 53.02Grade Unit: %Intercept: 38.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0029
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
53.02
Grade Unit
%
Intercept
38.8 m
True Width
34.7 m
From
65.2 m
To
104 m
Hole Depth
214 m
Intercept Depth
65.2 m

Classification

Sample Type
drill
Group ID
R-0029:65.2-104

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“53.02”

Context: 38.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 34.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0029titaniumGrade: 6.46Grade Unit: %Intercept: 38.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0029
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.46
Grade Unit
%
Intercept
38.8 m
True Width
34.7 m
From
65.2 m
To
104 m
Hole Depth
214 m
Intercept Depth
65.2 m

Classification

Sample Type
drill
Group ID
R-0029:65.2-104

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“6.46”

Context: 38.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 34.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0029vanadiumGrade: 0.441Grade Unit: %Intercept: 38.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0029
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.441
Grade Unit
%
Intercept
38.8 m
True Width
34.7 m
From
65.2 m
To
104 m
Hole Depth
214 m
Intercept Depth
65.2 m

Classification

Sample Type
drill
Group ID
R-0029:65.2-104

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.441”

Context: 38.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 34.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0030iron_oreGrade: 42.57Grade Unit: %Intercept: 90.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0030
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
42.57
Grade Unit
%
Intercept
90.9 m
True Width
49.5 m
From
83.1 m
To
174 m
Hole Depth
209 m
Intercept Depth
83.1 m

Classification

Sample Type
drill
Group ID
R-0030:83.1-174

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“42.57”

Context: 90.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 49.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0030titaniumGrade: 5.4Grade Unit: %Intercept: 90.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0030
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.4
Grade Unit
%
Intercept
90.9 m
True Width
49.5 m
From
83.1 m
To
174 m
Hole Depth
209 m
Intercept Depth
83.1 m

Classification

Sample Type
drill
Group ID
R-0030:83.1-174

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“5.40”

Context: 90.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 49.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0030vanadiumGrade: 0.303Grade Unit: %Intercept: 90.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0030
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.303
Grade Unit
%
Intercept
90.9 m
True Width
49.5 m
From
83.1 m
To
174 m
Hole Depth
209 m
Intercept Depth
83.1 m

Classification

Sample Type
drill
Group ID
R-0030:83.1-174

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“0.303”

Context: 90.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 49.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0030iron_oreGrade: 50.81Grade Unit: %Intercept: 18.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0030
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
50.81
Grade Unit
%
Intercept
18.6 m
True Width
10.2 m
From
83.1 m
To
101.7 m
Hole Depth
209 m
Intercept Depth
83.1 m

Classification

Sample Type
drill
Group ID
R-0030:83.1-101.7

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“50.81”

Context: 18.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0030titaniumGrade: 6.56Grade Unit: %Intercept: 18.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0030
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.56
Grade Unit
%
Intercept
18.6 m
True Width
10.2 m
From
83.1 m
To
101.7 m
Hole Depth
209 m
Intercept Depth
83.1 m

Classification

Sample Type
drill
Group ID
R-0030:83.1-101.7

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“6.56”

Context: 18.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0030vanadiumGrade: 0.398Grade Unit: %Intercept: 18.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0030
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.398
Grade Unit
%
Intercept
18.6 m
True Width
10.2 m
From
83.1 m
To
101.7 m
Hole Depth
209 m
Intercept Depth
83.1 m

Classification

Sample Type
drill
Group ID
R-0030:83.1-101.7

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.398”

Context: 18.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 10.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0031iron_oreGrade: 38.11Grade Unit: %Intercept: 108.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0031
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
38.11
Grade Unit
%
Intercept
108.2 m
True Width
87.2 m
From
63.4 m
To
171.6 m
Hole Depth
215 m
Intercept Depth
63.4 m

Classification

Sample Type
drill
Group ID
R-0031:63.4-171.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“38.11”

Context: 108.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 87.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0031titaniumGrade: 5.13Grade Unit: %Intercept: 108.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0031
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.13
Grade Unit
%
Intercept
108.2 m
True Width
87.2 m
From
63.4 m
To
171.6 m
Hole Depth
215 m
Intercept Depth
63.4 m

Classification

Sample Type
drill
Group ID
R-0031:63.4-171.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“5.13”

Context: 108.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 87.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0031vanadiumGrade: 0.254Grade Unit: %Intercept: 108.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0031
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.254
Grade Unit
%
Intercept
108.2 m
True Width
87.2 m
From
63.4 m
To
171.6 m
Hole Depth
215 m
Intercept Depth
63.4 m

Classification

Sample Type
drill
Group ID
R-0031:63.4-171.6

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“0.254”

Context: 108.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 87.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0031iron_oreGrade: 42.71Grade Unit: %Intercept: 43.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0031
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
42.71
Grade Unit
%
Intercept
43.1 m
True Width
34.7 m
From
97 m
To
140.1 m
Hole Depth
215 m
Intercept Depth
63.4 m

Classification

Sample Type
drill
Group ID
R-0031:97-140.1

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“42.71”

Context: 43.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 34.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0031titaniumGrade: 5.88Grade Unit: %Intercept: 43.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0031
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.88
Grade Unit
%
Intercept
43.1 m
True Width
34.7 m
From
97 m
To
140.1 m
Hole Depth
215 m
Intercept Depth
63.4 m

Classification

Sample Type
drill
Group ID
R-0031:97-140.1

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“5.88”

Context: 43.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 34.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0031vanadiumGrade: 0.309Grade Unit: %Intercept: 43.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0031
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.309
Grade Unit
%
Intercept
43.1 m
True Width
34.7 m
From
97 m
To
140.1 m
Hole Depth
215 m
Intercept Depth
63.4 m

Classification

Sample Type
drill
Group ID
R-0031:97-140.1

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“0.309”

Context: 43.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 34.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0032iron_oreGrade: 37.13Grade Unit: %Intercept: 144.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0032
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
37.13
Grade Unit
%
Intercept
144.2 m
True Width
135.3 m
From
53.8 m
To
198 m
Hole Depth
263 m
Intercept Depth
53.8 m

Classification

Sample Type
drill
Group ID
R-0032:53.8-198

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“37.13”

Context: 144.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 135.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0032titaniumGrade: 5.04Grade Unit: %Intercept: 144.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0032
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.04
Grade Unit
%
Intercept
144.2 m
True Width
135.3 m
From
53.8 m
To
198 m
Hole Depth
263 m
Intercept Depth
53.8 m

Classification

Sample Type
drill
Group ID
R-0032:53.8-198

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“5.04”

Context: 144.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 135.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0032vanadiumGrade: 0.234Grade Unit: %Intercept: 144.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0032
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.234
Grade Unit
%
Intercept
144.2 m
True Width
135.3 m
From
53.8 m
To
198 m
Hole Depth
263 m
Intercept Depth
53.8 m

Classification

Sample Type
drill
Group ID
R-0032:53.8-198

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“0.234”

Context: 144.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 135.3

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0032iron_oreGrade: 44.68Grade Unit: %Intercept: 56 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0032
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
44.68
Grade Unit
%
Intercept
56 m
True Width
52.6 m
From
114 m
To
170 m
Hole Depth
263 m
Intercept Depth
53.8 m

Classification

Sample Type
drill
Group ID
R-0032:114-170

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“44.68”

Context: 56.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0032titaniumGrade: 6.5Grade Unit: %Intercept: 56 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0032
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.5
Grade Unit
%
Intercept
56 m
True Width
52.6 m
From
114 m
To
170 m
Hole Depth
263 m
Intercept Depth
53.8 m

Classification

Sample Type
drill
Group ID
R-0032:114-170

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“6.50”

Context: 56.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0032vanadiumGrade: 0.294Grade Unit: %Intercept: 56 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0032
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.294
Grade Unit
%
Intercept
56 m
True Width
52.6 m
From
114 m
To
170 m
Hole Depth
263 m
Intercept Depth
53.8 m

Classification

Sample Type
drill
Group ID
R-0032:114-170

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“0.294”

Context: 56.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 52.6

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0033iron_oreGrade: 44.07Grade Unit: %Intercept: 100.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0033
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
44.07
Grade Unit
%
Intercept
100.6 m
True Width
77.5 m
From
67.4 m
To
168 m
Hole Depth
251 m
Intercept Depth
67.7 m

Classification

Sample Type
drill
Group ID
R-0033:67.4-168

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“44.07”

Context: 100.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 77.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0033titaniumGrade: 6.38Grade Unit: %Intercept: 100.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0033
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.38
Grade Unit
%
Intercept
100.6 m
True Width
77.5 m
From
67.4 m
To
168 m
Hole Depth
251 m
Intercept Depth
67.7 m

Classification

Sample Type
drill
Group ID
R-0033:67.4-168

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“6.38”

Context: 100.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 77.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0033vanadiumGrade: 0.286Grade Unit: %Intercept: 100.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0033
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.286
Grade Unit
%
Intercept
100.6 m
True Width
77.5 m
From
67.4 m
To
168 m
Hole Depth
251 m
Intercept Depth
67.7 m

Classification

Sample Type
drill
Group ID
R-0033:67.4-168

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“0.286”

Context: 100.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 77.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0033iron_oreGrade: 48.03Grade Unit: %Intercept: 56 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0033
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
48.03
Grade Unit
%
Intercept
56 m
True Width
43.1 m
From
97 m
To
153 m
Hole Depth
251 m
Intercept Depth
67.7 m

Classification

Sample Type
drill
Group ID
R-0033:97-153

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“48.03”

Context: 56.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 43.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0033titaniumGrade: 7.25Grade Unit: %Intercept: 56 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0033
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.25
Grade Unit
%
Intercept
56 m
True Width
43.1 m
From
97 m
To
153 m
Hole Depth
251 m
Intercept Depth
67.7 m

Classification

Sample Type
drill
Group ID
R-0033:97-153

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“7.25”

Context: 56.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 43.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0033vanadiumGrade: 0.304Grade Unit: %Intercept: 56 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0033
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.304
Grade Unit
%
Intercept
56 m
True Width
43.1 m
From
97 m
To
153 m
Hole Depth
251 m
Intercept Depth
67.7 m

Classification

Sample Type
drill
Group ID
R-0033:97-153

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.304”

Context: 56.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 43.1

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0034iron_oreGrade: 43.19Grade Unit: %Intercept: 126.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0034
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
43.19
Grade Unit
%
Intercept
126.2 m
True Width
124 m
From
68.8 m
To
195 m
Hole Depth
230 m
Intercept Depth
48.7 m

Classification

Sample Type
drill
Group ID
R-0034:68.8-195

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“43.19”

Context: 126.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 124

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0034titaniumGrade: 6.05Grade Unit: %Intercept: 126.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0034
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.05
Grade Unit
%
Intercept
126.2 m
True Width
124 m
From
68.8 m
To
195 m
Hole Depth
230 m
Intercept Depth
48.7 m

Classification

Sample Type
drill
Group ID
R-0034:68.8-195

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“6.05”

Context: 126.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 124

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0034vanadiumGrade: 0.293Grade Unit: %Intercept: 126.2 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0034
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.293
Grade Unit
%
Intercept
126.2 m
True Width
124 m
From
68.8 m
To
195 m
Hole Depth
230 m
Intercept Depth
48.7 m

Classification

Sample Type
drill
Group ID
R-0034:68.8-195

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“0.293”

Context: 126.2

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 124

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0034iron_oreGrade: 48.61Grade Unit: %Intercept: 63.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0034
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
48.61
Grade Unit
%
Intercept
63.9 m
True Width
62.8 m
From
106.1 m
To
170 m
Hole Depth
230 m
Intercept Depth
48.7 m

Classification

Sample Type
drill
Group ID
R-0034:106.1-170

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“48.61”

Context: 63.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 62.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0034titaniumGrade: 7.01Grade Unit: %Intercept: 63.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0034
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.01
Grade Unit
%
Intercept
63.9 m
True Width
62.8 m
From
106.1 m
To
170 m
Hole Depth
230 m
Intercept Depth
48.7 m

Classification

Sample Type
drill
Group ID
R-0034:106.1-170

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“7.01”

Context: 63.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 62.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0034vanadiumGrade: 0.344Grade Unit: %Intercept: 63.9 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0034
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.344
Grade Unit
%
Intercept
63.9 m
True Width
62.8 m
From
106.1 m
To
170 m
Hole Depth
230 m
Intercept Depth
48.7 m

Classification

Sample Type
drill
Group ID
R-0034:106.1-170

Location

Azimuth
38 °
Dip
-60 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.344”

Context: 63.9

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 62.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0035iron_oreGrade: 30.98Grade Unit: %Intercept: 13.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0035
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
30.98
Grade Unit
%
Intercept
13.5 m
True Width
9.9 m
From
8.5 m
To
22 m
Hole Depth
97 m
Intercept Depth
8.5 m

Classification

Sample Type
drill
Group ID
R-0035:8.5-22

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a moderate intercept of iron mineralization, but it is a previously reported result.

Evidence · table

“30.98”

Context: 13.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0035titaniumGrade: 2.93Grade Unit: %Intercept: 13.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0035
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
2.93
Grade Unit
%
Intercept
13.5 m
True Width
9.9 m
From
8.5 m
To
22 m
Hole Depth
97 m
Intercept Depth
8.5 m

Classification

Sample Type
drill
Group ID
R-0035:8.5-22

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a moderate intercept of titanium mineralization, but it is a previously reported result.

Evidence · table

“2.93”

Context: 13.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0035vanadiumGrade: 0.193Grade Unit: %Intercept: 13.5 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0035
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.193
Grade Unit
%
Intercept
13.5 m
True Width
9.9 m
From
8.5 m
To
22 m
Hole Depth
97 m
Intercept Depth
8.5 m

Classification

Sample Type
drill
Group ID
R-0035:8.5-22

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a moderate intercept of vanadium mineralization, but it is a previously reported result.

Evidence · table

“0.193”

Context: 13.5

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 9.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0036iron_oreGrade: 45.34Grade Unit: %Intercept: 73 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0036
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
45.34
Grade Unit
%
Intercept
73 m
True Width
36.5 m
From
55 m
To
128 m
Hole Depth
209 m
Intercept Depth
47.4 m

Classification

Sample Type
drill
Group ID
R-0036:55-128

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“45.34”

Context: 73.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 36.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0036titaniumGrade: 6.31Grade Unit: %Intercept: 73 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0036
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.31
Grade Unit
%
Intercept
73 m
True Width
36.5 m
From
55 m
To
128 m
Hole Depth
209 m
Intercept Depth
47.4 m

Classification

Sample Type
drill
Group ID
R-0036:55-128

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“6.31”

Context: 73.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 36.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0036vanadiumGrade: 0.345Grade Unit: %Intercept: 73 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0036
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.345
Grade Unit
%
Intercept
73 m
True Width
36.5 m
From
55 m
To
128 m
Hole Depth
209 m
Intercept Depth
47.4 m

Classification

Sample Type
drill
Group ID
R-0036:55-128

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length

Evidence · table

“0.345”

Context: 73.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 36.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0036iron_oreGrade: 50.46Grade Unit: %Intercept: 34 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0036
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
50.46
Grade Unit
%
Intercept
34 m
True Width
17 m
From
80 m
To
114 m
Hole Depth
209 m
Intercept Depth
47.4 m

Classification

Sample Type
drill
Group ID
R-0036:80-114

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length

Evidence · table

“50.46”

Context: 34.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0036titaniumGrade: 7.21Grade Unit: %Intercept: 34 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0036
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.21
Grade Unit
%
Intercept
34 m
True Width
17 m
From
80 m
To
114 m
Hole Depth
209 m
Intercept Depth
47.4 m

Classification

Sample Type
drill
Group ID
R-0036:80-114

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length

Evidence · table

“7.21”

Context: 34.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0036vanadiumGrade: 0.395Grade Unit: %Intercept: 34 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0036
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.395
Grade Unit
%
Intercept
34 m
True Width
17 m
From
80 m
To
114 m
Hole Depth
209 m
Intercept Depth
47.4 m

Classification

Sample Type
drill
Group ID
R-0036:80-114

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a good width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length

Evidence · table

“0.395”

Context: 34.0

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 17

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0037iron_oreGrade: 45.93Grade Unit: %Intercept: 50.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0037
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
45.93
Grade Unit
%
Intercept
50.8 m
True Width
41.9 m
From
52.2 m
To
103 m
Hole Depth
206 m
Intercept Depth
42.6 m

Classification

Sample Type
drill
Group ID
R-0037:52.2-103

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“45.93”

Context: 50.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 41.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0037titaniumGrade: 6.46Grade Unit: %Intercept: 50.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0037
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.46
Grade Unit
%
Intercept
50.8 m
True Width
41.9 m
From
52.2 m
To
103 m
Hole Depth
206 m
Intercept Depth
42.6 m

Classification

Sample Type
drill
Group ID
R-0037:52.2-103

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“6.46”

Context: 50.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 41.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0037vanadiumGrade: 0.348Grade Unit: %Intercept: 50.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0037
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.348
Grade Unit
%
Intercept
50.8 m
True Width
41.9 m
From
52.2 m
To
103 m
Hole Depth
206 m
Intercept Depth
42.6 m

Classification

Sample Type
drill
Group ID
R-0037:52.2-103

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“0.348”

Context: 50.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 41.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0038iron_oreGrade: 41.23Grade Unit: %Intercept: 100.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0038
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
41.23
Grade Unit
%
Intercept
100.8 m
True Width
73.7 m
From
45.4 m
To
146.2 m
Hole Depth
182 m
Intercept Depth
45.4 m

Classification

Sample Type
drill
Group ID
R-0038:45.4-146.2

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of iron mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“41.23”

Context: 100.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 73.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0038titaniumGrade: 5.21Grade Unit: %Intercept: 100.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0038
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.21
Grade Unit
%
Intercept
100.8 m
True Width
73.7 m
From
45.4 m
To
146.2 m
Hole Depth
182 m
Intercept Depth
45.4 m

Classification

Sample Type
drill
Group ID
R-0038:45.4-146.2

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of titanium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“5.21”

Context: 100.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 73.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0038vanadiumGrade: 0.302Grade Unit: %Intercept: 100.8 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0038
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.302
Grade Unit
%
Intercept
100.8 m
True Width
73.7 m
From
45.4 m
To
146.2 m
Hole Depth
182 m
Intercept Depth
45.4 m

Classification

Sample Type
drill
Group ID
R-0038:45.4-146.2

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a broad intercept of vanadium mineralization with good true width, but it is a previously reported result.

Positive factors

  • Broad intercept length
  • Good true width

Evidence · table

“0.302”

Context: 100.8

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 73.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0038iron_oreGrade: 46.2Grade Unit: %Intercept: 42.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0038
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
46.2
Grade Unit
%
Intercept
42.4 m
True Width
31 m
From
103.9 m
To
146.2 m
Hole Depth
182 m
Intercept Depth
45.4 m

Classification

Sample Type
drill
Group ID
R-0038:103.9-146.2

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“46.20”

Context: 42.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 31

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0038titaniumGrade: 6.35Grade Unit: %Intercept: 42.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0038
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.35
Grade Unit
%
Intercept
42.4 m
True Width
31 m
From
103.9 m
To
146.2 m
Hole Depth
182 m
Intercept Depth
45.4 m

Classification

Sample Type
drill
Group ID
R-0038:103.9-146.2

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Good intercept length and true width

Evidence · table

“6.35”

Context: 42.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 31

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0038vanadiumGrade: 0.364Grade Unit: %Intercept: 42.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0038
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.364
Grade Unit
%
Intercept
42.4 m
True Width
31 m
From
103.9 m
To
146.2 m
Hole Depth
182 m
Intercept Depth
45.4 m

Classification

Sample Type
drill
Group ID
R-0038:103.9-146.2

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Good intercept length and true width

Evidence · table

“0.364”

Context: 42.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 31

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0039iron_oreGrade: 47.42Grade Unit: %Intercept: 110.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0039
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
47.42
Grade Unit
%
Intercept
110.1 m
True Width
106.5 m
From
84 m
To
194 m
Hole Depth
251 m
Intercept Depth
84 m

Classification

Sample Type
drill
Group ID
R-0039:84-194

Location

Azimuth
218 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a broad width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Broad intercept length and true width

Evidence · table

“47.42”

Context: 110.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 106.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0039titaniumGrade: 5.95Grade Unit: %Intercept: 110.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0039
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.95
Grade Unit
%
Intercept
110.1 m
True Width
106.5 m
From
84 m
To
194 m
Hole Depth
251 m
Intercept Depth
84 m

Classification

Sample Type
drill
Group ID
R-0039:84-194

Location

Azimuth
218 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a broad width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Broad intercept length and true width

Evidence · table

“5.95”

Context: 110.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 106.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0039vanadiumGrade: 0.354Grade Unit: %Intercept: 110.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0039
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.354
Grade Unit
%
Intercept
110.1 m
True Width
106.5 m
From
84 m
To
194 m
Hole Depth
251 m
Intercept Depth
84 m

Classification

Sample Type
drill
Group ID
R-0039:84-194

Location

Azimuth
218 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a broad width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Broad intercept length and true width

Evidence · table

“0.354”

Context: 110.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 106.5

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0039iron_oreGrade: 58.15Grade Unit: %Intercept: 52.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0039
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
58.15
Grade Unit
%
Intercept
52.1 m
True Width
50.4 m
From
97 m
To
149.1 m
Hole Depth
251 m
Intercept Depth
84 m

Classification

Sample Type
drill
Group ID
R-0039:97-149.1

Location

Azimuth
218 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is an exceptional grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • Exceptional grade iron
  • Significant intercept length and true width

Evidence · table

“58.15”

Context: 52.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 50.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0039titaniumGrade: 7.68Grade Unit: %Intercept: 52.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0039
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.68
Grade Unit
%
Intercept
52.1 m
True Width
50.4 m
From
97 m
To
149.1 m
Hole Depth
251 m
Intercept Depth
84 m

Classification

Sample Type
drill
Group ID
R-0039:97-149.1

Location

Azimuth
218 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is an exceptional grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • Exceptional grade titanium
  • Significant intercept length and true width

Evidence · table

“7.68”

Context: 52.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 50.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0039vanadiumGrade: 0.459Grade Unit: %Intercept: 52.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0039
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.459
Grade Unit
%
Intercept
52.1 m
True Width
50.4 m
From
97 m
To
149.1 m
Hole Depth
251 m
Intercept Depth
84 m

Classification

Sample Type
drill
Group ID
R-0039:97-149.1

Location

Azimuth
218 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is an exceptional grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • Exceptional grade vanadium
  • Significant intercept length and true width

Evidence · table

“0.459”

Context: 52.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 50.4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0039iron_oreGrade: 45.88Grade Unit: %Intercept: 27.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0039
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
45.88
Grade Unit
%
Intercept
27.6 m
True Width
26.7 m
From
166.4 m
To
194 m
Hole Depth
251 m
Intercept Depth
84 m

Classification

Sample Type
drill
Group ID
R-0039:166.4-194

Location

Azimuth
218 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of iron mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“45.88”

Context: 27.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 26.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0039titaniumGrade: 5.85Grade Unit: %Intercept: 27.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0039
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
5.85
Grade Unit
%
Intercept
27.6 m
True Width
26.7 m
From
166.4 m
To
194 m
Hole Depth
251 m
Intercept Depth
84 m

Classification

Sample Type
drill
Group ID
R-0039:166.4-194

Location

Azimuth
218 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of titanium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“5.85”

Context: 27.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 26.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0039vanadiumGrade: 0.35Grade Unit: %Intercept: 27.6 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0039
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.35
Grade Unit
%
Intercept
27.6 m
True Width
26.7 m
From
166.4 m
To
194 m
Hole Depth
251 m
Intercept Depth
84 m

Classification

Sample Type
drill
Group ID
R-0039:166.4-194

Location

Azimuth
218 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a good intercept of vanadium mineralization, but it is a previously reported result.

Positive factors

  • Good intercept length and true width

Evidence · table

“0.350”

Context: 27.6

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 26.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0040iron_oreGrade: 51.2Grade Unit: %Intercept: 45.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0040
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
51.2
Grade Unit
%
Intercept
45.1 m
True Width
31.9 m
From
84.9 m
To
130 m
Hole Depth
170 m
Intercept Depth
38.3 m

Classification

Sample Type
drill
Group ID
R-0040:84.9-130

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Significant intercept length and true width

Evidence · table

“51.20”

Context: 45.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 31.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0040titaniumGrade: 7.94Grade Unit: %Intercept: 45.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0040
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
7.94
Grade Unit
%
Intercept
45.1 m
True Width
31.9 m
From
84.9 m
To
130 m
Hole Depth
170 m
Intercept Depth
38.3 m

Classification

Sample Type
drill
Group ID
R-0040:84.9-130

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade titanium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade titanium
  • Significant intercept length and true width

Evidence · table

“7.94”

Context: 45.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 31.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0040vanadiumGrade: 0.34Grade Unit: %Intercept: 45.1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0040
Commodity
vanadium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
0.34
Grade Unit
%
Intercept
45.1 m
True Width
31.9 m
From
84.9 m
To
130 m
Hole Depth
170 m
Intercept Depth
38.3 m

Classification

Sample Type
drill
Group ID
R-0040:84.9-130

Location

Azimuth
38 °
Dip
-70 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade vanadium intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade vanadium
  • Significant intercept length and true width

Evidence · table

“0.340”

Context: 45.1

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 31.9

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0041iron_oreGrade: 47.97Grade Unit: %Intercept: 46.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0041
Commodity
iron_ore
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
47.97
Grade Unit
%
Intercept
46.4 m
True Width
34.7 m
From
6.6 m
To
53 m
Hole Depth
100 m
Intercept Depth
6.6 m

Classification

Sample Type
drill
Group ID
R-0041:6.6-53

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Reasoning: This is a high-grade iron intercept over a significant width, but it is a previously reported result.

Positive factors

  • High-grade iron
  • Good intercept length and true width

Evidence · table

“47.97”

Context: 46.4

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 34.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

R-0041titaniumGrade: 6.49Grade Unit: %Intercept: 46.4 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
R-0041
Commodity
titanium
Region
canada
Reported Region
canada
Ticker
SAGA

Geometry

Grade
6.49
Grade Unit
%
Intercept
46.4 m
True Width
34.7 m
From
6.6 m
To
53 m
Hole Depth
100 m
Intercept Depth
6.6 m

Classification

Sample Type
drill
Group ID
R-0041:6.6-53

Location

Azimuth
38 °
Dip
-45 °

QA/QC

Laboratory
Impact Global Solutions (IGS)
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes

Dates

Event date
2026-09-10T00:00:00.000Z

Positive factors

  • High-grade titanium

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 34.7

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Stale Data Re-releasenegative

Historical results re-announced with no new assays or reinterpretation — low genuine novelty.

Why it applies: the fact restates a prior release

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.