Signature Resources Reports First Drill Results from Winter Drill Program; New Potential Zone Intersected

Original announcement by tmx on

Company
Signature Resources Ltd.
Ticker
SGU
Exchange
TSX
Region
Northwestern Ontario, Canada
Primary commodity
Gold
Secondary commodities
None reported
Document categories
Drill results
Extracted
2026-09-14 22:58:49 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Signature Resources announced initial drill results from its winter program at the Lingman Lake gold deposit, confirming its geological model and intersecting a new potential mineralized zone. The program included two diamond drillholes, LM 25-01 and LM 25-02, which returned multiple narrow gold intercepts, with a highest grade of 3.33 g/t Au over 1 meter. Additionally, hole LM 25-04 encountered a strong quartz-chlorite-carbonate vein breccia system with sulphide mineralization over approximately 19 meters, coinciding with a 1,700-meter VLF conductor, indicating a new exploration target.

Reasoning: Signature Resources reported initial drill results from its winter program, confirming geological modeling and intersecting a new potential mineralized zone (LM 25-04) with a 1,700m strike length, which is a significant exploration upside. While individual gold grades from LM 25-01 and LM 25-02 are generally narrow and below moderate for an underground deposit, the highest grade of 3.33 g/t Au is above the 75th percentile for similar deposit types. QA/QC is well-disclosed with QP sign-off and certified labs, enhancing confidence in the data.

Positive factors

  • New potential mineralized zone identified with significant strike length
  • Confirms geological model for known mineralization
  • QA/QC procedures are disclosed and robust
  • Qualified Person (QP) has signed off on technical content
  • Certified laboratory (SGS) used for assaying

Negative factors

  • Individual intercept grades are generally below moderate for an underground gold system
  • No true width disclosed for reported intercepts
  • Assay delays impacting data compilation

Facts used in scoring: 33

Classification and evidence

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release explicitly states that Signature Resources maintains an industry standard Quality Assurance / Quality Control (QA/QC) program, mentions SGS as a certified laboratory, and details the insertion of blanks, reference materials, and pulp duplicates.

Evidence · text

“Signature Resources maintains an industry standard Quality Assurance / Quality Control (QA/QC) program at the Lingman Lake Project to ensure sampling and analysis of all exploration work is conducted in accordance with best practices. ... SGS is a certified laboratory and also have internal quality control ("QC") programs that include insertion of reagent blanks, reference materials, and pulp duplicates.”

QP/CP Signedpositive · Story-specific tag

Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.

Why it applies: The press release states that Mr. Walter Hanych, P. Geo, consultant and Head Geologist, is a Qualified Person under NI 43-101 regulations and has reviewed and approved the scientific and technical content.

Evidence · text

“The scientific and technical content of this press release have been reviewed and approved by Mr. Walter Hanych, P. Geo, consultant and Head Geologist, is a Qualified Persons under NI 43-101 regulations.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: Footnotes for both drill holes explicitly state that 'Reported widths are drill intercepts (core Lengths)', indicating that true widths are not provided.

Evidence · text

“Reported widths are drill intercepts (core Lengths)”

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The document highlights the intersection of a 'New Potential Zone' in hole LM 25-04, located approximately 250 m south of historic drilling, which represents an extension beyond previously known mineralization.

Evidence · text

“New Potential Zone Intersected ... located approximately 250 m south of the historic drilling.”

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: The first two drillholes, LM 25-01 and LM 25-02, were designed to test zones approximately 150 meters down dip on the eastern edge of the known resource mineralization, which is characteristic of infill or extension drilling within an existing resource area.

Evidence · text

“Both holes were designed to test the zones ~150 metre ("m") down dip on the eastern edge of the known resource mineralization.”

Below Moderate Grade Interceptsnegative · Story-specific tag

No canonical definition is currently available.

Why it applies: The highest reported gold grade is 3.33 g/t Au over 1 meter. For an underground gold deposit, a moderate grade is typically 4 g/t Au, placing this intercept below that threshold.

Evidence · table

“3.33”

Context: LM25-02

Extracted facts

Stored fact records: 33. Some facts used in scoring do not have a stored record.

Drill Results (33)

LM24-05-25-01Lingman Lake · goldGrade: 0.22Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.22
Grade Unit
g/t
Intercept
1 m
From
478 m
To
479 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:478-479
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.22 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.22”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.14Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.14
Grade Unit
g/t
Intercept
1 m
From
480 m
To
481 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:480-481
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.14 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.14”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.18Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.18
Grade Unit
g/t
Intercept
1 m
From
488 m
To
489 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:488-489
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.18 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.18”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.95Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.95
Grade Unit
g/t
Intercept
1 m
From
515 m
To
516 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:515-516
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.95 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.95”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 2.51Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
2.51
Grade Unit
g/t
Intercept
1 m
From
530 m
To
531 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:530-531
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 2.51 g/t Au is at the lower end of the 'weak' threshold for underground gold, confirming mineralization at depth but remaining narrow.

Positive factors

  • Confirms mineralization at depth
  • Grade is at the lower end of the 'weak' threshold for underground gold
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Apparent width only

Evidence · table

“2.51”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.26Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.26
Grade Unit
g/t
Intercept
1 m
From
531 m
To
532 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:531-532
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.26 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.26”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.26Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.26
Grade Unit
g/t
Intercept
1 m
From
537 m
To
538 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:537-538
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.26 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.26”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.15Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.15
Grade Unit
g/t
Intercept
1 m
From
538 m
To
539 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:538-539
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.15 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.15”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.11Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
1 m
From
543 m
To
544 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:543-544
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.11 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.11”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.5Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.5
Grade Unit
g/t
Intercept
1 m
From
547 m
To
548 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:547-548
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.5 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.5”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.16Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.16
Grade Unit
g/t
Intercept
1 m
From
548 m
To
549 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:548-549
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.16 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.16”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.1Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
1 m
From
554 m
To
555 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:554-555
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.1 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.1”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.19Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.19
Grade Unit
g/t
Intercept
1 m
From
561 m
To
562 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:561-562
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.19 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.19”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM24-05-25-01Lingman Lake · goldGrade: 0.2Grade Unit: g/tIntercept: 1 mHistorical resultNeeds review: historical_restatementView all details
Link to this fact

Identity

Hole ID
LM24-05-25-01
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.2
Grade Unit
g/t
Intercept
1 m
From
563 m
To
564 m
Hole Depth
599 m
Intercept Depth
478 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM24-05-25-01:563-564
Mining Method
underground

Location

Location
North Zone
Azimuth
180 °
Dip
-45 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
Yes
Review Reason
historical_restatement
Interp. Status
scored
Historical
Yes
Historical Source Date
2005-01-01T00:00:00.000Z

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.2 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.2”

Context: LM24-05-25-01

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.11Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
1 m
From
279 m
To
280 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:279-280
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.11 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.11”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.17Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.17
Grade Unit
g/t
Intercept
1 m
From
280 m
To
281 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:280-281
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.17 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.17”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.27Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.27
Grade Unit
g/t
Intercept
1 m
From
281 m
To
282 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:281-282
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.27 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.27”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.39Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.39
Grade Unit
g/t
Intercept
1 m
From
315 m
To
316 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:315-316
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.39 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.39”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.1Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
1 m
From
316 m
To
317 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:316-317
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.1 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.1”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.33Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.33
Grade Unit
g/t
Intercept
1 m
From
324 m
To
325 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:324-325
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.33 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.33”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.12Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.12
Grade Unit
g/t
Intercept
1 m
From
325 m
To
326 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:325-326
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.12 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.12”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.11Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
1 m
From
326 m
To
327 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:326-327
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.11 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.11”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.28Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.28
Grade Unit
g/t
Intercept
1 m
From
328 m
To
329 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:328-329
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.28 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.28”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.96Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.96
Grade Unit
g/t
Intercept
1 m
From
348 m
To
349 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:348-349
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.96 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.96”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.11Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.11
Grade Unit
g/t
Intercept
1 m
From
350 m
To
351 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:350-351
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.11 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.11”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.13Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.13
Grade Unit
g/t
Intercept
1 m
From
405 m
To
406 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:405-406
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.13 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.13”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 3.33Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
3.33
Grade Unit
g/t
Intercept
1 m
From
410 m
To
411 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:410-411
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 3.33 g/t Au is above the 'weak' threshold for underground gold, confirming mineralization at depth, but remains narrow and below the 'moderate' threshold.

Positive factors

  • Confirms mineralization at depth
  • Grade is above the 'weak' threshold for underground gold
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Apparent width only
  • Grade is below 'moderate' threshold for underground gold

Evidence · table

“3.33”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.12Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.12
Grade Unit
g/t
Intercept
1 m
From
418 m
To
419 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:418-419
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.12 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.12”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.12Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.12
Grade Unit
g/t
Intercept
1 m
From
438 m
To
439 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:438-439
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.12 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.12”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.19Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.19
Grade Unit
g/t
Intercept
1 m
From
464 m
To
465 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:464-465
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.19 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.19”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.95Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.95
Grade Unit
g/t
Intercept
1 m
From
468 m
To
469 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:468-469
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.95 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.95”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.66Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.66
Grade Unit
g/t
Intercept
1 m
From
469 m
To
470 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:469-470
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.66 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.66”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

LM25-02Lingman Lake · goldGrade: 0.4Grade Unit: g/tIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
LM25-02
Project
Lingman Lake
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
SGU

Geometry

Grade
0.4
Grade Unit
g/t
Intercept
1 m
From
470 m
To
471 m
Hole Depth
530 m
Intercept Depth
279 m

Classification

Program
mixed
Sample Type
drill
Group ID
LM25-02:470-471
Mining Method
underground

Location

Location
North Zone
Azimuth
360 °
Dip
-60 °
Loc. Source
document

QA/QC

Laboratory
SGS Red Lake and SGS Burnaby
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Compositing

Cutoff Grade
0.1
Cutoff Unit
g/t

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-02-13T00:00:00.000Z

Reasoning: This 1-meter intercept of 0.4 g/t Au confirms mineralization at depth but is low grade and narrow, typical of the reported fluctuations in the system.

Positive factors

  • Confirms mineralization at depth
  • QA/QC disclosed and robust

Negative factors

  • Narrow intercept length
  • Low grade for underground gold deposit
  • Apparent width only

Evidence · table

“0.4”

Context: LM25-02

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

Nearology Playneutral

Value premise rests on proximity to a known deposit rather than own results.

Why it applies: proximity is offered as the value premise: "In November 2023, Wataynikaneyap Power energized a new 115kV high tension transmission line within 40 km of the historic"

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.