SILVER MOUNTAIN REPORTS HIGH GRADE SILVER IN UNDERGROUND CHANNEL SAMPLING PROGRAM AND PROVIDES UPDATE ON STOCKPILING AT ITS RELIQUIAS PROJECT, PERU
Original announcement by tmx on
- Company
- Silver Mountain Resources Inc.
- Ticker
- AGMR
- Exchange
- TSX
- Region
- Huancavelica, Peru
- Primary commodity
- Silver
- Secondary commodities
- Lead, Zinc, Copper, Gold
- Document categories
- Drill results, Production
- Extracted
- 2026-09-13 11:18:49 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Silver Mountain Resources has reported high-grade polymetallic channel sampling results from its Reliquias Project in Huancavelica, Peru, with several intercepts showing strong to exceptional grades for silver, lead, and copper. These results, collected from underground workings on Level 340, reinforce the high-grade nature of the deposit and often exceed grades reported in the mineral resource estimate. The company is also advancing towards commercial production in Q3 2026, having stockpiled approximately 525 metric tonnes of mineralized material from ongoing rehabilitation and development activities.
Reasoning: The channel sampling program returned consistently high-grade polymetallic results, particularly for silver, lead, and copper, from underground workings, which reinforces the quality of the Reliquias deposit and supports the company's mine-readiness efforts. The disclosure of robust QA/QC procedures and QP sign-off enhances confidence in the results. The stockpiling of mineralized material is a positive step towards planned commercial production in Q3 2026.
Positive factors
- High-grade polymetallic channel sample results, particularly for silver, lead, and copper, reinforcing the quality of the Reliquias deposit.
- Confirmation of readily accessible high-grade veins at various mine levels, exceeding prior resource estimate grades.
- Comprehensive QA/QC procedures disclosed, including certified labs, standards, blanks, and duplicates, with QP sign-off.
- True width of channel samples explicitly stated by perpendicular collection method.
- Advancement towards commercial production with significant stockpiling of mineralized material.
Facts used in scoring: 80
Classification and evidence
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release details systematic and rigorous sampling and analytical protocols, including the use of certified laboratories (ALS and Certimin) and the insertion of certified control standards, blanks, and duplicates.
Evidence · text
“Silver Mountain follows systematic and rigorous sampling and analytical protocols which meet industry standards. These protocols are summarized below. ... Samples are sent by batch to the ALS and Certimin laboratories in Lima, Peru for assaying. Silver Mountain independently inserts certified control standards, fine and coarse blanks, and duplicates into the sample stream to monitor data quality.”
QP/CP Signedpositive · Story-specific tag
Qualified Person (QP) or Competent Person (CP) named and signed off — a member of a recognized professional association (e.g., AusIMM, SME, AIG, P.Geo) with relevant experience.
Why it applies: The scientific and technical content has been reviewed and approved by Antonio Cruz Bermudez, P. Geo. and Registered Member FAIG, who is a 'qualified person' as defined in NI 43-101.
Evidence · text
“The scientific and technical content in this news release has been reviewed and approved by Antonio Cruz Bermudez, P. Geo. and Registered Member FAIG, who is a "qualified person" (as defined in National Instrument 43-101 – Standards of Disclosure for Mineral Projects ) and independent of the Company for purposes of Section 1.5 of National Instrument 43-101 – Standards of Disclosure for Mineral Projects .”
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The document explicitly states that all channel samples were collected perpendicular to the veins, indicating that the reported widths represent true widths.
Evidence · text
“All samples were collected perpendicular to the veins using portable rock saws.”
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: The channel sampling is described as 'ongoing underground channel sampling' and part of 'mine-readiness work aimed at starting commercial production', which is analogous to infill or definition drilling to support production.
Evidence · text
“underground channel sampling and early-stage stockpiling of mineralized material at its Reliquias Project, located in Huancavelica, Peru . These activities are part of the Company's planned mine-readiness work aimed at starting commercial production at its Reliquias Project during Q3 of 2026.”
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The channel sample SMR-025262 returned 510 g/t Ag over 0.82m, which is an exceptional silver grade for an underground setting.
Evidence · table
“510”
Context: 0.82
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The channel sample SMR-025272 returned 414 g/t Ag over 1.04m, which is an exceptional silver grade for an underground setting.
Evidence · table
“414”
Context: 1.04
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The channel sample SMR-025272 returned 17.30% Pb over 1.04m, which is an exceptional lead grade for an underground setting.
Evidence · table
“17.30”
Context: 1.04
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The channel sample SMR-025272 returned 3.06% Cu over 1.04m, which is an exceptional copper grade for an underground setting.
Evidence · table
“3.06”
Context: 1.04
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The channel sample SMR-025269 returned 10.70% Pb over 1.07m, which is an exceptional lead grade for an underground setting.
Evidence · table
“10.70”
Context: 1.07
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: The channel sample SMR-025269 returned 2.70% Cu over 1.07m, which is an exceptional copper grade for an underground setting.
Evidence · table
“2.70”
Context: 1.07
Extracted facts
Stored fact records: 80. Some facts used in scoring do not have a stored record.
Drill Results (80)
SMR-025269Reliquias Project · silverGrade: 336Grade Unit: g/tIntercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- SMR-025269
- Project
- Reliquias Project
- Commodity
- silver
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 336
- Grade Unit
- g/t
- Intercept
- 1.07 m
- True Width
- 1.07 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 27.34
- Metal Eq. Unit
- oz/t
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Ayayay vein returned a strong silver grade over a true width, contributing positively to the understanding of the deposit's high-grade nature and supporting mine-readiness.
Positive factors
- Strong silver grade (336 g/t) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
- High silver equivalent grade (27.34 oz/t) further enhances prospectivity.
Evidence · table
“336”
Context: 1.07
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.07
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025269Reliquias Project · leadGrade: 10.7Grade Unit: %Intercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- SMR-025269
- Project
- Reliquias Project
- Commodity
- lead
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 10.7
- Grade Unit
- %
- Intercept
- 1.07 m
- True Width
- 1.07 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Ayayay vein returned an exceptional lead grade over a true width, highlighting the polymetallic nature and high-grade potential of the deposit.
Positive factors
- Exceptional lead grade (10.70%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“10.70”
Context: 1.07
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.07
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025269Reliquias Project · zincGrade: 11.7Grade Unit: %Intercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- SMR-025269
- Project
- Reliquias Project
- Commodity
- zinc
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 11.7
- Grade Unit
- %
- Intercept
- 1.07 m
- True Width
- 1.07 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Ayayay vein returned a strong zinc grade over a true width, contributing to the overall high-grade polymetallic profile of the deposit.
Positive factors
- Strong zinc grade (11.70%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“11.70”
Context: 1.07
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.07
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025269Reliquias Project · copperGrade: 2.7Grade Unit: %Intercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- SMR-025269
- Project
- Reliquias Project
- Commodity
- copper
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 2.7
- Grade Unit
- %
- Intercept
- 1.07 m
- True Width
- 1.07 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Ayayay vein returned an exceptional copper grade over a true width, significantly enhancing the polymetallic value of the intercept.
Positive factors
- Exceptional copper grade (2.70%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“2.70”
Context: 1.07
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.07
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025269Reliquias Project · goldGrade: 0.34Grade Unit: g/tIntercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- SMR-025269
- Project
- Reliquias Project
- Commodity
- gold
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 1.07 m
- True Width
- 1.07 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: The gold grade in this channel sample is weak for an underground setting, though it contributes to the overall polymetallic nature of the intercept.
Negative factors
- Weak gold grade (0.34 g/t) for an underground channel sample.
Evidence · table
“0.34”
Context: 1.07
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.07
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025272Reliquias Project · silverGrade: 414Grade Unit: g/tIntercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- SMR-025272
- Project
- Reliquias Project
- Commodity
- silver
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 414
- Grade Unit
- g/t
- Intercept
- 1.04 m
- True Width
- 1.04 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 32.08
- Metal Eq. Unit
- oz/t
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Ayayay vein returned an exceptional silver grade over a true width, significantly reinforcing the high-grade potential of the deposit and supporting mine-readiness.
Positive factors
- Exceptional silver grade (414 g/t) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
- Very high silver equivalent grade (32.08 oz/t) further enhances prospectivity.
Evidence · table
“414”
Context: 1.04
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.04
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025272Reliquias Project · leadGrade: 17.3Grade Unit: %Intercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- SMR-025272
- Project
- Reliquias Project
- Commodity
- lead
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 17.3
- Grade Unit
- %
- Intercept
- 1.04 m
- True Width
- 1.04 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Ayayay vein returned an exceptional lead grade over a true width, significantly contributing to the high-grade polymetallic nature of the intercept.
Positive factors
- Exceptional lead grade (17.30%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“17.30”
Context: 1.04
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.04
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025272Reliquias Project · zincGrade: 8.5Grade Unit: %Intercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- SMR-025272
- Project
- Reliquias Project
- Commodity
- zinc
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 8.5
- Grade Unit
- %
- Intercept
- 1.04 m
- True Width
- 1.04 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Ayayay vein returned a moderate zinc grade over a true width, adding to the polymetallic value of the intercept.
Positive factors
- Moderate zinc grade (8.50%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“8.50”
Context: 1.04
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.04
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025272Reliquias Project · copperGrade: 3.06Grade Unit: %Intercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- SMR-025272
- Project
- Reliquias Project
- Commodity
- copper
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 3.06
- Grade Unit
- %
- Intercept
- 1.04 m
- True Width
- 1.04 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Ayayay vein returned an exceptional copper grade over a true width, significantly enhancing the polymetallic value of the intercept.
Positive factors
- Exceptional copper grade (3.06%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“3.06”
Context: 1.04
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.04
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025272Reliquias Project · goldGrade: 0.28Grade Unit: g/tIntercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- SMR-025272
- Project
- Reliquias Project
- Commodity
- gold
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.28
- Grade Unit
- g/t
- Intercept
- 1.04 m
- True Width
- 1.04 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Ayayay vein
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: The gold grade in this channel sample is weak for an underground setting, though it contributes to the overall polymetallic nature of the intercept.
Negative factors
- Weak gold grade (0.28 g/t) for an underground channel sample.
Evidence · table
“0.28”
Context: 1.04
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.04
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025262Reliquias Project · silverGrade: 510Grade Unit: g/tIntercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- SMR-025262
- Project
- Reliquias Project
- Commodity
- silver
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 510
- Grade Unit
- g/t
- Intercept
- 0.82 m
- True Width
- 0.82 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 30.11
- Metal Eq. Unit
- oz/t
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_1 vein returned an exceptional silver grade over a true width, significantly reinforcing the high-grade potential of the deposit and supporting mine-readiness.
Positive factors
- Exceptional silver grade (510 g/t) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
- Very high silver equivalent grade (30.11 oz/t) further enhances prospectivity.
Evidence · table
“510”
Context: 0.82
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.82
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025262Reliquias Project · leadGrade: 7.4Grade Unit: %Intercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- SMR-025262
- Project
- Reliquias Project
- Commodity
- lead
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 7.4
- Grade Unit
- %
- Intercept
- 0.82 m
- True Width
- 0.82 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_1 vein returned a strong lead grade over a true width, contributing to the high-grade polymetallic nature of the intercept.
Positive factors
- Strong lead grade (7.40%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“7.40”
Context: 0.82
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.82
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025262Reliquias Project · zincGrade: 13.3Grade Unit: %Intercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- SMR-025262
- Project
- Reliquias Project
- Commodity
- zinc
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 13.3
- Grade Unit
- %
- Intercept
- 0.82 m
- True Width
- 0.82 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_1 vein returned a strong zinc grade over a true width, contributing to the overall high-grade polymetallic profile of the deposit.
Positive factors
- Strong zinc grade (13.30%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“13.30”
Context: 0.82
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.82
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025262Reliquias Project · copperGrade: 0.98Grade Unit: %Intercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- SMR-025262
- Project
- Reliquias Project
- Commodity
- copper
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.98
- Grade Unit
- %
- Intercept
- 0.82 m
- True Width
- 0.82 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_1 vein returned a moderate copper grade over a true width, adding to the polymetallic value of the intercept.
Positive factors
- Moderate copper grade (0.98%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“0.98”
Context: 0.82
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.82
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025262Reliquias Project · goldGrade: 0.31Grade Unit: g/tIntercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- SMR-025262
- Project
- Reliquias Project
- Commodity
- gold
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 0.82 m
- True Width
- 0.82 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: The gold grade in this channel sample is weak for an underground setting, though it contributes to the overall polymetallic nature of the intercept.
Negative factors
- Weak gold grade (0.31 g/t) for an underground channel sample.
Evidence · table
“0.31”
Context: 0.82
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.82
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025265Reliquias Project · silverGrade: 168Grade Unit: g/tIntercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- SMR-025265
- Project
- Reliquias Project
- Commodity
- silver
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 168
- Grade Unit
- g/t
- Intercept
- 1.17 m
- True Width
- 1.17 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 15.07
- Metal Eq. Unit
- oz/t
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_1 vein returned a moderate silver grade over a true width, contributing positively to the understanding of the deposit's high-grade nature.
Positive factors
- Moderate silver grade (168 g/t) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“168”
Context: 1.17
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.17
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025265Reliquias Project · leadGrade: 5.3Grade Unit: %Intercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- SMR-025265
- Project
- Reliquias Project
- Commodity
- lead
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 5.3
- Grade Unit
- %
- Intercept
- 1.17 m
- True Width
- 1.17 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_1 vein returned a moderate lead grade over a true width, adding to the polymetallic value of the intercept.
Positive factors
- Moderate lead grade (5.30%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“5.30”
Context: 1.17
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.17
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025265Reliquias Project · zincGrade: 10.1Grade Unit: %Intercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- SMR-025265
- Project
- Reliquias Project
- Commodity
- zinc
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 10.1
- Grade Unit
- %
- Intercept
- 1.17 m
- True Width
- 1.17 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_1 vein returned a strong zinc grade over a true width, contributing to the overall high-grade polymetallic profile of the deposit.
Positive factors
- Strong zinc grade (10.10%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“10.10”
Context: 1.17
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.17
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025265Reliquias Project · copperGrade: 0.38Grade Unit: %Intercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- SMR-025265
- Project
- Reliquias Project
- Commodity
- copper
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.38
- Grade Unit
- %
- Intercept
- 1.17 m
- True Width
- 1.17 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_1 vein returned a moderate copper grade over a true width, adding to the polymetallic value of the intercept.
Positive factors
- Moderate copper grade (0.38%) for an underground channel sample.
Evidence · table
“0.38”
Context: 1.17
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.17
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025265Reliquias Project · goldGrade: 0.15Grade Unit: g/tIntercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- SMR-025265
- Project
- Reliquias Project
- Commodity
- gold
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 1.17 m
- True Width
- 1.17 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_1
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: The gold grade in this channel sample is weak for an underground setting, though it contributes to the overall polymetallic nature of the intercept.
Negative factors
- Weak gold grade (0.15 g/t) for an underground channel sample.
Evidence · table
“0.15”
Context: 1.17
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.17
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025248Reliquias Project · silverGrade: 82Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- SMR-025248
- Project
- Reliquias Project
- Commodity
- silver
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 82
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.65 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 7.69
- Metal Eq. Unit
- oz/t
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_2 vein returned a weak silver grade over a true width, contributing to the polymetallic profile of the deposit.
Positive factors
- Weak silver grade (82 g/t) for an underground channel sample, but still within economic range for polymetallic veins.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“82”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.65
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025248Reliquias Project · leadGrade: 3.2Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- SMR-025248
- Project
- Reliquias Project
- Commodity
- lead
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 3.2
- Grade Unit
- %
- Intercept
- 0.65 m
- True Width
- 0.65 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_2 vein returned a moderate lead grade over a true width, adding to the polymetallic value of the intercept.
Positive factors
- Moderate lead grade (3.20%) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“3.20”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.65
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025248Reliquias Project · zincGrade: 4.1Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- SMR-025248
- Project
- Reliquias Project
- Commodity
- zinc
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 4.1
- Grade Unit
- %
- Intercept
- 0.65 m
- True Width
- 0.65 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_2 vein returned a weak zinc grade over a true width, contributing to the overall polymetallic profile of the deposit.
Positive factors
- Weak zinc grade (4.10%) for an underground channel sample, but still contributes to polymetallic value.
Evidence · table
“4.10”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.65
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025248Reliquias Project · copperGrade: 0.24Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- SMR-025248
- Project
- Reliquias Project
- Commodity
- copper
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.24
- Grade Unit
- %
- Intercept
- 0.65 m
- True Width
- 0.65 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_2 vein returned a weak copper grade over a true width, contributing to the polymetallic value of the intercept.
Positive factors
- Weak copper grade (0.24%) for an underground channel sample.
Evidence · table
“0.24”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.65
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025248Reliquias Project · goldGrade: 0.26Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- SMR-025248
- Project
- Reliquias Project
- Commodity
- gold
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 0.65 m
- True Width
- 0.65 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: The gold grade in this channel sample is weak for an underground setting, though it contributes to the overall polymetallic nature of the intercept.
Negative factors
- Weak gold grade (0.26 g/t) for an underground channel sample.
Evidence · table
“0.26”
Context: 0.65
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.65
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025259Reliquias Project · silverGrade: 114Grade Unit: g/tIntercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- SMR-025259
- Project
- Reliquias Project
- Commodity
- silver
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 114
- Grade Unit
- g/t
- Intercept
- 0.97 m
- True Width
- 0.97 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8
- Metal Eq. Unit
- oz/t
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_2 vein returned a moderate silver grade over a true width, contributing positively to the understanding of the deposit's high-grade nature.
Positive factors
- Moderate silver grade (114 g/t) for an underground channel sample.
- True width disclosed, indicating accurate representation of mineralization.
Evidence · table
“114”
Context: 0.97
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025259Reliquias Project · leadGrade: 2.43Grade Unit: %Intercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- SMR-025259
- Project
- Reliquias Project
- Commodity
- lead
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 2.43
- Grade Unit
- %
- Intercept
- 0.97 m
- True Width
- 0.97 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_2 vein returned a weak lead grade over a true width, adding to the polymetallic value of the intercept.
Positive factors
- Weak lead grade (2.43%) for an underground channel sample, but still contributes to polymetallic value.
Evidence · table
“2.43”
Context: 0.97
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025259Reliquias Project · zincGrade: 4.1Grade Unit: %Intercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- SMR-025259
- Project
- Reliquias Project
- Commodity
- zinc
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 4.1
- Grade Unit
- %
- Intercept
- 0.97 m
- True Width
- 0.97 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_2 vein returned a weak zinc grade over a true width, contributing to the overall polymetallic profile of the deposit.
Positive factors
- Weak zinc grade (4.10%) for an underground channel sample, but still contributes to polymetallic value.
Evidence · table
“4.10”
Context: 0.97
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025259Reliquias Project · copperGrade: 0.32Grade Unit: %Intercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- SMR-025259
- Project
- Reliquias Project
- Commodity
- copper
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 0.97 m
- True Width
- 0.97 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Tensional Ayay_2 vein returned a weak copper grade over a true width, contributing to the polymetallic value of the intercept.
Positive factors
- Weak copper grade (0.32%) for an underground channel sample.
Evidence · table
“0.32”
Context: 0.97
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025259Reliquias Project · goldGrade: 0.09Grade Unit: g/tIntercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- SMR-025259
- Project
- Reliquias Project
- Commodity
- gold
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.97 m
- True Width
- 0.97 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Tensional Ayay_2
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: The gold grade in this channel sample is weak for an underground setting, though it contributes to the overall polymetallic nature of the intercept.
Negative factors
- Weak gold grade (0.09 g/t) for an underground channel sample.
Evidence · table
“0.09”
Context: 0.97
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.97
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025251Reliquias Project · silverGrade: 16Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- SMR-025251
- Project
- Reliquias Project
- Commodity
- silver
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 16
- Grade Unit
- g/t
- Intercept
- 0.9 m
- True Width
- 0.9 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.13
- Metal Eq. Unit
- oz/t
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Matacaballo vein returned a weak silver grade over a true width, indicating lower mineralization compared to other veins.
Negative factors
- Weak silver grade (16 g/t) for an underground channel sample, below typical economic thresholds.
Evidence · table
“16”
Context: 0.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025251Reliquias Project · leadGrade: 0.33Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- SMR-025251
- Project
- Reliquias Project
- Commodity
- lead
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 0.9 m
- True Width
- 0.9 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Matacaballo vein returned a weak lead grade over a true width, indicating lower mineralization compared to other veins.
Negative factors
- Weak lead grade (0.33%) for an underground channel sample, below typical economic thresholds.
Evidence · table
“0.33”
Context: 0.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025251Reliquias Project · zincGrade: 0.53Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- SMR-025251
- Project
- Reliquias Project
- Commodity
- zinc
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.53
- Grade Unit
- %
- Intercept
- 0.9 m
- True Width
- 0.9 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Matacaballo vein returned a weak zinc grade over a true width, indicating lower mineralization compared to other veins.
Negative factors
- Weak zinc grade (0.53%) for an underground channel sample, below typical economic thresholds.
Evidence · table
“0.53”
Context: 0.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025251Reliquias Project · copperGrade: 0.03Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- SMR-025251
- Project
- Reliquias Project
- Commodity
- copper
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 0.9 m
- True Width
- 0.9 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Matacaballo vein returned a weak copper grade over a true width, indicating lower mineralization compared to other veins.
Negative factors
- Weak copper grade (0.03%) for an underground channel sample, below typical economic thresholds.
Evidence · table
“0.03”
Context: 0.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025251Reliquias Project · goldGrade: 0.04Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- SMR-025251
- Project
- Reliquias Project
- Commodity
- gold
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 0.9 m
- True Width
- 0.9 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: The gold grade in this channel sample is weak for an underground setting, indicating lower mineralization compared to other veins.
Negative factors
- Weak gold grade (0.04 g/t) for an underground channel sample, below typical economic thresholds.
Evidence · table
“0.04”
Context: 0.90
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.9
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025255Reliquias Project · silverGrade: 29Grade Unit: g/tIntercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- SMR-025255
- Project
- Reliquias Project
- Commodity
- silver
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 29
- Grade Unit
- g/t
- Intercept
- 0.44 m
- True Width
- 0.44 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1.61
- Metal Eq. Unit
- oz/t
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Matacaballo vein returned a weak silver grade over a true width, indicating lower mineralization compared to other veins.
Negative factors
- Weak silver grade (29 g/t) for an underground channel sample, below typical economic thresholds.
Evidence · table
“29”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025255Reliquias Project · leadGrade: 0.11Grade Unit: %Intercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- SMR-025255
- Project
- Reliquias Project
- Commodity
- lead
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 0.44 m
- True Width
- 0.44 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Matacaballo vein returned a weak lead grade over a true width, indicating lower mineralization compared to other veins.
Negative factors
- Weak lead grade (0.11%) for an underground channel sample, below typical economic thresholds.
Evidence · table
“0.11”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025255Reliquias Project · zincGrade: 0.75Grade Unit: %Intercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- SMR-025255
- Project
- Reliquias Project
- Commodity
- zinc
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.75
- Grade Unit
- %
- Intercept
- 0.44 m
- True Width
- 0.44 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Matacaballo vein returned a weak zinc grade over a true width, indicating lower mineralization compared to other veins.
Negative factors
- Weak zinc grade (0.75%) for an underground channel sample, below typical economic thresholds.
Evidence · table
“0.75”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025255Reliquias Project · copperGrade: 0.04Grade Unit: %Intercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- SMR-025255
- Project
- Reliquias Project
- Commodity
- copper
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 0.44 m
- True Width
- 0.44 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: This channel sample from the Matacaballo vein returned a weak copper grade over a true width, indicating lower mineralization compared to other veins.
Negative factors
- Weak copper grade (0.04%) for an underground channel sample, below typical economic thresholds.
Evidence · table
“0.04”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
SMR-025255Reliquias Project · goldGrade: 0.07Grade Unit: g/tIntercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- SMR-025255
- Project
- Reliquias Project
- Commodity
- gold
- Region
- peru
- Reported Region
- Huancavelica, Peru
- Ticker
- AGMR
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 0.44 m
- True Width
- 0.44 m
Classification
- Program
- resource
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Matacaballo
- Loc. Source
- document
QA/QC
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: The gold grade in this channel sample is weak for an underground setting, indicating lower mineralization compared to other veins.
Negative factors
- Weak gold grade (0.07 g/t) for an underground channel sample, below typical economic thresholds.
Evidence · table
“0.07”
Context: 0.44
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.44
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "resource"
CN-07Reliquias · silverGrade: 336Grade Unit: g/tIntercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- CN-07
- Project
- Reliquias
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 336
- Grade Unit
- g/t
- Intercept
- 1.07 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 336 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 359.5 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 336 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“336”
Context: CN-07
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-07Reliquias · leadGrade: 10.7Grade Unit: %Intercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- CN-07
- Project
- Reliquias
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 10.7
- Grade Unit
- %
- Intercept
- 1.07 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 10.7 % lead is exceptional against the default band [10, 6, 3, 1] %. Grade×width 11.4 %·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 10.7 % lead is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“10.70”
Context: CN-07
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-07Reliquias · zincGrade: 11.7Grade Unit: %Intercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- CN-07
- Project
- Reliquias
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 11.7
- Grade Unit
- %
- Intercept
- 1.07 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 11.7 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 12.5 %·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 11.7 % zinc is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“11.70”
Context: CN-07
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-07Reliquias · copperGrade: 2.7Grade Unit: %Intercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- CN-07
- Project
- Reliquias
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 2.7
- Grade Unit
- %
- Intercept
- 1.07 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 2.7 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 2.9 %·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 2.7 % copper is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.70”
Context: CN-07
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-07Reliquias · goldGrade: 0.34Grade Unit: g/tIntercept: 1.07 mView all detailsHide details
Identity
- Hole ID
- CN-07
- Project
- Reliquias
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.34
- Grade Unit
- g/t
- Intercept
- 1.07 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.34 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.4 g/t·m is below.
Negative factors
- 0.34 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.34”
Context: CN-07
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-08Reliquias · silverGrade: 414Grade Unit: g/tIntercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- CN-08
- Project
- Reliquias
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 414
- Grade Unit
- g/t
- Intercept
- 1.04 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 414 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 430.6 g/t·m is weak (grade alone is strong; the better of the two is used).
Positive factors
- 414 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“414”
Context: CN-08
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-08Reliquias · leadGrade: 17.3Grade Unit: %Intercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- CN-08
- Project
- Reliquias
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 17.3
- Grade Unit
- %
- Intercept
- 1.04 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 17.3 % lead is exceptional against the default band [10, 6, 3, 1] %. Grade×width 18.0 %·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 17.3 % lead is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“17.30”
Context: CN-08
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-08Reliquias · zincGrade: 8.5Grade Unit: %Intercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- CN-08
- Project
- Reliquias
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 8.5
- Grade Unit
- %
- Intercept
- 1.04 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 8.5 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 8.8 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.50”
Context: CN-08
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-08Reliquias · copperGrade: 3.06Grade Unit: %Intercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- CN-08
- Project
- Reliquias
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 3.06
- Grade Unit
- %
- Intercept
- 1.04 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 3.06 % copper is exceptional against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 3.2 %·m is below (grade alone is exceptional; the better of the two is used).
Positive factors
- 3.06 % copper is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.06”
Context: CN-08
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-08Reliquias · goldGrade: 0.28Grade Unit: g/tIntercept: 1.04 mView all detailsHide details
Identity
- Hole ID
- CN-08
- Project
- Reliquias
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.28
- Grade Unit
- g/t
- Intercept
- 1.04 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.28 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.28 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.28”
Context: CN-08
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-05Reliquias · silverGrade: 510Grade Unit: g/tIntercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- CN-05
- Project
- Reliquias
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 510
- Grade Unit
- g/t
- Intercept
- 0.82 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 510 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 418.2 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 510 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“510”
Context: CN-05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-05Reliquias · leadGrade: 7.4Grade Unit: %Intercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- CN-05
- Project
- Reliquias
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 7.4
- Grade Unit
- %
- Intercept
- 0.82 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 7.4 % lead is strong against the default band [10, 6, 3, 1] %. Grade×width 6.1 %·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 7.4 % lead is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.40”
Context: CN-05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-05Reliquias · zincGrade: 13.3Grade Unit: %Intercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- CN-05
- Project
- Reliquias
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 13.3
- Grade Unit
- %
- Intercept
- 0.82 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 13.3 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 10.9 %·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 13.3 % zinc is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“13.30”
Context: CN-05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-05Reliquias · copperGrade: 0.98Grade Unit: %Intercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- CN-05
- Project
- Reliquias
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.98
- Grade Unit
- %
- Intercept
- 0.82 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.98 % copper is moderate against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.8 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.98”
Context: CN-05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-05Reliquias · goldGrade: 0.31Grade Unit: g/tIntercept: 0.82 mView all detailsHide details
Identity
- Hole ID
- CN-05
- Project
- Reliquias
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 0.82 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.31 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.3 g/t·m is below.
Negative factors
- 0.31 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.31”
Context: CN-05
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-06Reliquias · silverGrade: 168Grade Unit: g/tIntercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- CN-06
- Project
- Reliquias
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 168
- Grade Unit
- g/t
- Intercept
- 1.17 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 168 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 196.6 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“168”
Context: CN-06
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-06Reliquias · leadGrade: 5.3Grade Unit: %Intercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- CN-06
- Project
- Reliquias
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 5.3
- Grade Unit
- %
- Intercept
- 1.17 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 5.3 % lead is moderate against the default band [10, 6, 3, 1] %. Grade×width 6.2 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“5.30”
Context: CN-06
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-06Reliquias · zincGrade: 10.1Grade Unit: %Intercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- CN-06
- Project
- Reliquias
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 10.1
- Grade Unit
- %
- Intercept
- 1.17 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 10.1 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 11.8 %·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 10.1 % zinc is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“10.10”
Context: CN-06
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-06Reliquias · copperGrade: 0.38Grade Unit: %Intercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- CN-06
- Project
- Reliquias
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.38
- Grade Unit
- %
- Intercept
- 1.17 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.38 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.4 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.38”
Context: CN-06
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-06Reliquias · goldGrade: 0.15Grade Unit: g/tIntercept: 1.17 mView all detailsHide details
Identity
- Hole ID
- CN-06
- Project
- Reliquias
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.15
- Grade Unit
- g/t
- Intercept
- 1.17 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.15 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.15 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.15”
Context: CN-06
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-01Reliquias · silverGrade: 82Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- CN-01
- Project
- Reliquias
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 82
- Grade Unit
- g/t
- Intercept
- 0.65 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 82 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 53.3 g/t·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“82”
Context: CN-01
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-01Reliquias · leadGrade: 3.2Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- CN-01
- Project
- Reliquias
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 3.2
- Grade Unit
- %
- Intercept
- 0.65 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 3.2 % lead is moderate against the default band [10, 6, 3, 1] %. Grade×width 2.1 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.20”
Context: CN-01
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-01Reliquias · zincGrade: 4.1Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- CN-01
- Project
- Reliquias
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 4.1
- Grade Unit
- %
- Intercept
- 0.65 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 4.1 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 2.7 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.10”
Context: CN-01
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-01Reliquias · copperGrade: 0.24Grade Unit: %Intercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- CN-01
- Project
- Reliquias
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.24
- Grade Unit
- %
- Intercept
- 0.65 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.24 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.2 %·m is below.
Negative factors
- 0.24 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.24”
Context: CN-01
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-01Reliquias · goldGrade: 0.26Grade Unit: g/tIntercept: 0.65 mView all detailsHide details
Identity
- Hole ID
- CN-01
- Project
- Reliquias
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.26
- Grade Unit
- g/t
- Intercept
- 0.65 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.26 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.2 g/t·m is below.
Negative factors
- 0.26 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.26”
Context: CN-01
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-04Reliquias · silverGrade: 114Grade Unit: g/tIntercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- CN-04
- Project
- Reliquias
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 114
- Grade Unit
- g/t
- Intercept
- 0.97 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 114 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 110.6 g/t·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“114”
Context: CN-04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-04Reliquias · leadGrade: 2.43Grade Unit: %Intercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- CN-04
- Project
- Reliquias
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 2.43
- Grade Unit
- %
- Intercept
- 0.97 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 2.43 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 2.4 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.43”
Context: CN-04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-04Reliquias · zincGrade: 4.1Grade Unit: %Intercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- CN-04
- Project
- Reliquias
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 4.1
- Grade Unit
- %
- Intercept
- 0.97 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 4.1 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 4.0 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.10”
Context: CN-04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-04Reliquias · copperGrade: 0.32Grade Unit: %Intercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- CN-04
- Project
- Reliquias
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.32
- Grade Unit
- %
- Intercept
- 0.97 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.32 % copper is weak against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.3 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.32”
Context: CN-04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-04Reliquias · goldGrade: 0.09Grade Unit: g/tIntercept: 0.97 mView all detailsHide details
Identity
- Hole ID
- CN-04
- Project
- Reliquias
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 0.97 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.09 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.09 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.09”
Context: CN-04
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-02Reliquias · silverGrade: 16Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- CN-02
- Project
- Reliquias
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 16
- Grade Unit
- g/t
- Intercept
- 0.9 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 16 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 14.4 g/t·m is below.
Negative factors
- 16 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“16”
Context: CN-02
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-02Reliquias · leadGrade: 0.33Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- CN-02
- Project
- Reliquias
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.33
- Grade Unit
- %
- Intercept
- 0.9 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.33 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.
Negative factors
- 0.33 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.33”
Context: CN-02
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-02Reliquias · zincGrade: 0.53Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- CN-02
- Project
- Reliquias
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.53
- Grade Unit
- %
- Intercept
- 0.9 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.53 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.5 %·m is below.
Negative factors
- 0.53 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.53”
Context: CN-02
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-02Reliquias · copperGrade: 0.03Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- CN-02
- Project
- Reliquias
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.03
- Grade Unit
- %
- Intercept
- 0.9 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.03 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.03 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.03”
Context: CN-02
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-02Reliquias · goldGrade: 0.04Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- CN-02
- Project
- Reliquias
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.04
- Grade Unit
- g/t
- Intercept
- 0.9 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0.04 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: CN-02
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-03Reliquias · silverGrade: 29Grade Unit: g/tIntercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- CN-03
- Project
- Reliquias
- Commodity
- silver
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 29
- Grade Unit
- g/t
- Intercept
- 0.44 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 29 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 12.8 g/t·m is below.
Negative factors
- 29 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“29”
Context: CN-03
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-03Reliquias · leadGrade: 0.11Grade Unit: %Intercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- CN-03
- Project
- Reliquias
- Commodity
- lead
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.11
- Grade Unit
- %
- Intercept
- 0.44 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.11 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.11 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.11”
Context: CN-03
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-03Reliquias · zincGrade: 0.75Grade Unit: %Intercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- CN-03
- Project
- Reliquias
- Commodity
- zinc
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.75
- Grade Unit
- %
- Intercept
- 0.44 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.75 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.
Negative factors
- 0.75 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.75”
Context: CN-03
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-03Reliquias · copperGrade: 0.04Grade Unit: %Intercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- CN-03
- Project
- Reliquias
- Commodity
- copper
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.04
- Grade Unit
- %
- Intercept
- 0.44 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.04 % copper is below against the default band [2.5, 1, 0.5, 0.25] %. Grade×width 0.0 %·m is below.
Negative factors
- 0.04 % copper is below the weak threshold (0.25 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.04”
Context: CN-03
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
CN-03Reliquias · goldGrade: 0.07Grade Unit: g/tIntercept: 0.44 mView all detailsHide details
Identity
- Hole ID
- CN-03
- Project
- Reliquias
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- AGMR
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 0.44 m
Classification
- Sample Type
- channel
- Mining Method
- underground
QA/QC
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2025-11-27T00:00:00.000Z
Reasoning: Expanded from assay table. 0.07 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.0 g/t·m is below.
Negative factors
- 0.07 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.07”
Context: CN-03
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.