# Silver X Intersects up to 17.86 m True Width at Blenda Rubia, Advancing Scalable Mining Strategy

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b

Original source: https://money.tmx.com/en/quote/AGX/news/8202849410522032/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable-

Publisher: tmx

Original announcement: 2026-04-16T11:35:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Silver X Mining Corp.

- Ticker: AGX

- Exchange: TSX

- Region: central Peru

- Primary commodity: Silver

- Secondary commodities: Lead, Zinc, Copper

- Document categories: Drill results

- Extracted: 2026-09-13 11:05:10 UTC

Narrative sentiment: 0.80 · Bullish

## Minestarters Atlas summary

Silver X Mining Corp. announced significant drill results from its Blenda Rubia target in central Peru, highlighting true widths up to 17.86 meters and high-grade silver-polymetallic mineralization. The results suggest a broad, continuous mineralized corridor with potential for bulk-style mining, which could enhance production scale and cost efficiency at the nearby Nueva Recuperada operation. The ongoing drill program includes both step-out and infill drilling to define and expand the system.

Reasoning: The drill results from Blenda Rubia reveal significant true widths and high-grade silver-polymetallic mineralization, supporting a potential shift towards bulk-style mining which could enhance production scale and cost efficiency for Silver X. The presence of both step-out and infill drilling indicates a comprehensive approach to both expanding and defining the resource, with most true widths disclosed, increasing confidence in the results.

- Positive factor: Significant true width intercepts, particularly 17.86m in DDH-BR-003, indicating potential for bulk-style mining.

- Positive factor: High-grade silver and polymetallic mineralization, with several intercepts exceeding exceptional and strong thresholds for silver, lead, and zinc.

- Positive factor: Mineralization extends beyond discrete veins into a continuous mineralized corridor, supporting scalability.

- Positive factor: Drill program includes both step-out and infill drilling, indicating both expansion and resource definition efforts.

- Positive factor: True widths are disclosed for most significant intercepts, providing better geological understanding.

- Positive factor: Proximity to existing processing plant positions Blenda Rubia as a potential low-cost feed source.

- Negative factor: True width for DDH-BR-005 is pending, limiting the geological interpretation for this significant intercept.

- Negative factor: One interval in DDH-BR-008 is noted as 'mined-out', indicating some historical extraction.

Facts used in scoring: 161

## Classification and evidence

No classification tags are available.

## Extracted facts

Stored fact records: 161. Some facts used in scoring do not have a stored record.

## Drill Results (161)

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-0)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 103.43
- Grade Unit: g/t
- Intercept: 4.55 m
- True Width: 1.41 m
- From: 260.4 m
- To: 264.95 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:260.4-264.95
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a reasonable true width, contributing positively to the understanding of the mineralized package.

- Positive factor: Moderate silver grade \(103.43 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 1.41m is disclosed, providing good geological context.

Evidence · table

> 103.43

Context: DDH-BR-001

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.41

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-1)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.42
- Grade Unit: %
- Intercept: 4.55 m
- True Width: 1.41 m
- From: 260.4 m
- To: 264.95 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:260.4-264.95
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate lead grade over a reasonable true width, contributing positively to the understanding of the mineralized package.

- Positive factor: Moderate lead grade \(1.42% Pb\) for an epithermal deposit.

- Positive factor: True width of 1.41m is disclosed, providing good geological context.

Evidence · table

> 1.42

Context: DDH-BR-001

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.41

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-2)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 4.55 m
- True Width: 1.41 m
- From: 260.4 m
- To: 264.95 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:260.4-264.95
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low, indicating it is not a primary contributor to the value of this intercept.

- Positive factor: True width of 1.41m is disclosed, providing good geological context.

- Negative factor: Weak zinc grade \(0.04% Zn\) for an epithermal deposit.

Evidence · table

> 0.04

Context: DDH-BR-001

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.41

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-3)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.003
- Grade Unit: %
- Intercept: 4.55 m
- True Width: 1.41 m
- From: 260.4 m
- To: 264.95 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:260.4-264.95
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this intercept.

- Positive factor: True width of 1.41m is disclosed, providing good geological context.

- Negative factor: Very low copper grade \(0.003% Cu\).

Evidence · table

> 0.003

Context: DDH-BR-001

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.41

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-4)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 79.94
- Grade Unit: g/t
- Intercept: 2.7 m
- True Width: 0.83 m
- From: 260.4 m
- To: 263.1 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:260.4-263.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(79.94 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.83m is disclosed.

Evidence · table

> 79.94

Context: 260.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.83

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-5)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.87
- Grade Unit: %
- Intercept: 2.7 m
- True Width: 0.83 m
- From: 260.4 m
- To: 263.1 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:260.4-263.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak for an epithermal deposit, but contributes to the polymetallic nature of the intercept.

- Positive factor: True width of 0.83m is disclosed.

- Negative factor: Weak lead grade \(0.87% Pb\) for an epithermal deposit.

Evidence · table

> 0.87

Context: 260.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.83

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-6)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 2.7 m
- True Width: 0.83 m
- From: 260.4 m
- To: 263.1 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:260.4-263.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 0.83m is disclosed.

- Negative factor: Weak zinc grade \(0.04% Zn\) for an epithermal deposit.

Evidence · table

> 0.04

Context: 260.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.83

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-7)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.002
- Grade Unit: %
- Intercept: 2.7 m
- True Width: 0.83 m
- From: 260.4 m
- To: 263.1 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:260.4-263.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 0.83m is disclosed.

- Negative factor: Very low copper grade \(0.002% Cu\).

Evidence · table

> 0.002

Context: 260.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.83

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-8)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 175.14
- Grade Unit: g/t
- Intercept: 1.45 m
- True Width: 0.45 m
- From: 263.5 m
- To: 264.95 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:263.5-264.95
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a narrow true width, significantly contributing to the overall intercept.

- Positive factor: Strong silver grade \(175.14 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.45m is disclosed.

Evidence · table

> 175.14

Context: 263.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.45

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-9)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.82
- Grade Unit: %
- Intercept: 1.45 m
- True Width: 0.45 m
- From: 263.5 m
- To: 264.95 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:263.5-264.95
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a narrow true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(2.82% Pb\) for an epithermal deposit.

- Positive factor: True width of 0.45m is disclosed.

Evidence · table

> 2.82

Context: 263.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.45

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-10)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 1.45 m
- True Width: 0.45 m
- From: 263.5 m
- To: 264.95 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:263.5-264.95
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 0.45m is disclosed.

- Negative factor: Weak zinc grade \(0.05% Zn\) for an epithermal deposit.

Evidence · table

> 0.05

Context: 263.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.45

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-11)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-001
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.005
- Grade Unit: %
- Intercept: 1.45 m
- True Width: 0.45 m
- From: 263.5 m
- To: 264.95 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-001:263.5-264.95
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 0.45m is disclosed.

- Negative factor: Very low copper grade \(0.005% Cu\).

Evidence · table

> 0.005

Context: 263.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.45

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-12)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-002
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 102.73
- Grade Unit: g/t
- Intercept: 2.2 m
- True Width: 0.75 m
- From: 366.2 m
- To: 368.4 m
- Intercept Depth: 366.2 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-002:366.2-368.4
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a narrow true width, contributing positively to the understanding of the mineralized package.

- Positive factor: Moderate silver grade \(102.73 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.75m is disclosed.

Evidence · table

> 102.73

Context: DDH-BR-002

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.75

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-13)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-002
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.27
- Grade Unit: %
- Intercept: 2.2 m
- True Width: 0.75 m
- From: 366.2 m
- To: 368.4 m
- Intercept Depth: 366.2 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-002:366.2-368.4
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate lead grade over a narrow true width, contributing positively to the understanding of the mineralized package.

- Positive factor: Moderate lead grade \(1.27% Pb\) for an epithermal deposit.

- Positive factor: True width of 0.75m is disclosed.

Evidence · table

> 1.27

Context: DDH-BR-002

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.75

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-14)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-002
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 2.2 m
- True Width: 0.75 m
- From: 366.2 m
- To: 368.4 m
- Intercept Depth: 366.2 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-002:366.2-368.4
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this intercept.

- Positive factor: True width of 0.75m is disclosed.

- Negative factor: Weak zinc grade \(0.02% Zn\) for an epithermal deposit.

Evidence · table

> 0.02

Context: DDH-BR-002

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.75

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-15)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-002
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.002
- Grade Unit: %
- Intercept: 2.2 m
- True Width: 0.75 m
- From: 366.2 m
- To: 368.4 m
- Intercept Depth: 366.2 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-002:366.2-368.4
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this intercept.

- Positive factor: True width of 0.75m is disclosed.

- Negative factor: Very low copper grade \(0.002% Cu\).

Evidence · table

> 0.002

Context: DDH-BR-002

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.75

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-16)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 79.86
- Grade Unit: g/t
- Intercept: 54.85 m
- True Width: 17.86 m
- From: 186.7 m
- To: 241.55 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:186.7-241.55
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept represents a very significant true width with a moderate silver grade, supporting the company's scalable mining strategy and indicating a broad mineralized corridor.

- Positive factor: Significant true width of 17.86m, indicating potential for bulk-style mining.

- Positive factor: Moderate silver grade \(79.86 g/t Ag\) over a very wide interval.

- Positive factor: This intercept is a key highlight of the release, confirming significant mining widths.

Evidence · table

> 79.86

Context: DDH-DDH-BR-003

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 17.86

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-17)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.77
- Grade Unit: %
- Intercept: 54.85 m
- True Width: 17.86 m
- From: 186.7 m
- To: 241.55 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:186.7-241.55
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this wide intercept.

- Positive factor: Significant true width of 17.86m is disclosed.

- Negative factor: Weak lead grade \(0.77% Pb\) for an epithermal deposit.

Evidence · table

> 0.77

Context: DDH-DDH-BR-003

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 17.86

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-18)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.13
- Grade Unit: %
- Intercept: 54.85 m
- True Width: 17.86 m
- From: 186.7 m
- To: 241.55 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:186.7-241.55
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this wide intercept.

- Positive factor: Significant true width of 17.86m is disclosed.

- Negative factor: Weak zinc grade \(0.13% Zn\) for an epithermal deposit.

Evidence · table

> 0.13

Context: DDH-DDH-BR-003

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 17.86

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-19)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.004
- Grade Unit: %
- Intercept: 54.85 m
- True Width: 17.86 m
- From: 186.7 m
- To: 241.55 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:186.7-241.55
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this wide intercept.

- Positive factor: Significant true width of 17.86m is disclosed.

- Negative factor: Very low copper grade \(0.004% Cu\).

Evidence · table

> 0.004

Context: DDH-DDH-BR-003

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 17.86

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-20)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 289.27
- Grade Unit: g/t
- Intercept: 10.8 m
- True Width: 2.8 m
- From: 187.7 m
- To: 198.5 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:187.7-198.5
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval within Vein 3 shows a strong silver grade over a good true width, significantly contributing to the overall intercept's value.

- Positive factor: Strong silver grade \(289.27 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 2.8m is disclosed.

Evidence · table

> 289.27

Context: 187.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-21)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.47
- Grade Unit: %
- Intercept: 10.8 m
- True Width: 2.8 m
- From: 187.7 m
- To: 198.5 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:187.7-198.5
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval within Vein 3 shows a moderate lead grade over a good true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(2.47% Pb\) for an epithermal deposit.

- Positive factor: True width of 2.8m is disclosed.

Evidence · table

> 2.47

Context: 187.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-22)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.34
- Grade Unit: %
- Intercept: 10.8 m
- True Width: 2.8 m
- From: 187.7 m
- To: 198.5 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:187.7-198.5
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 2.8m is disclosed.

- Negative factor: Weak zinc grade \(0.34% Zn\) for an epithermal deposit.

Evidence · table

> 0.34

Context: 187.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-23)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.003
- Grade Unit: %
- Intercept: 10.8 m
- True Width: 2.8 m
- From: 187.7 m
- To: 198.5 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:187.7-198.5
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 2.8m is disclosed.

- Negative factor: Very low copper grade \(0.003% Cu\).

Evidence · table

> 0.003

Context: 187.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-24)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 49.82
- Grade Unit: g/t
- Intercept: 2.85 m
- True Width: 0.93 m
- From: 203.5 m
- To: 206.35 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:203.5-206.35
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval within Vein 1 shows a moderate silver grade over a narrow true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(49.82 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.93m is disclosed.

Evidence · table

> 49.82

Context: 203.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.93

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-25)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.62
- Grade Unit: %
- Intercept: 2.85 m
- True Width: 0.93 m
- From: 203.5 m
- To: 206.35 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:203.5-206.35
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 0.93m is disclosed.

- Negative factor: Weak lead grade \(0.62% Pb\) for an epithermal deposit.

Evidence · table

> 0.62

Context: 203.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.93

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-26)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.18
- Grade Unit: %
- Intercept: 2.85 m
- True Width: 0.93 m
- From: 203.5 m
- To: 206.35 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:203.5-206.35
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 0.93m is disclosed.

- Negative factor: Weak zinc grade \(0.18% Zn\) for an epithermal deposit.

Evidence · table

> 0.18

Context: 203.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.93

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-27)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.003
- Grade Unit: %
- Intercept: 2.85 m
- True Width: 0.93 m
- From: 203.5 m
- To: 206.35 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:203.5-206.35
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 0.93m is disclosed.

- Negative factor: Very low copper grade \(0.003% Cu\).

Evidence · table

> 0.003

Context: 203.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.93

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-28)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 52.84
- Grade Unit: g/t
- Intercept: 9.2 m
- True Width: 3 m
- From: 206.35 m
- To: 215.55 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:206.35-215.55
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(52.84 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 3.0m is disclosed.

Evidence · table

> 52.84

Context: 206.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-29)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.65
- Grade Unit: %
- Intercept: 9.2 m
- True Width: 3 m
- From: 206.35 m
- To: 215.55 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:206.35-215.55
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 3.0m is disclosed.

- Negative factor: Weak lead grade \(0.65% Pb\) for an epithermal deposit.

Evidence · table

> 0.65

Context: 206.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-30)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 9.2 m
- True Width: 3 m
- From: 206.35 m
- To: 215.55 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:206.35-215.55
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 3.0m is disclosed.

- Negative factor: Weak zinc grade \(0.04% Zn\) for an epithermal deposit.

Evidence · table

> 0.04

Context: 206.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-31)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.007
- Grade Unit: %
- Intercept: 9.2 m
- True Width: 3 m
- From: 206.35 m
- To: 215.55 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:206.35-215.55
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 3.0m is disclosed.

- Negative factor: Very low copper grade \(0.007% Cu\).

Evidence · table

> 0.007

Context: 206.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-32)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 48.15
- Grade Unit: g/t
- Intercept: 7.6 m
- True Width: 2.47 m
- From: 217.75 m
- To: 225.35 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:217.75-225.35
- Mining Method: mixed

#### Location

- Location: Tensional veins veins
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(48.15 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 2.47m is disclosed.

Evidence · table

> 48.15

Context: 217.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.47

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-33)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 7.6 m
- True Width: 2.47 m
- From: 217.75 m
- To: 225.35 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:217.75-225.35
- Mining Method: mixed

#### Location

- Location: Tensional veins veins
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 2.47m is disclosed.

- Negative factor: Weak lead grade \(0.60% Pb\) for an epithermal deposit.

Evidence · table

> 0.60

Context: 217.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.47

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-34)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.07
- Grade Unit: %
- Intercept: 7.6 m
- True Width: 2.47 m
- From: 217.75 m
- To: 225.35 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:217.75-225.35
- Mining Method: mixed

#### Location

- Location: Tensional veins veins
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 2.47m is disclosed.

- Negative factor: Weak zinc grade \(0.07% Zn\) for an epithermal deposit.

Evidence · table

> 0.07

Context: 217.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.47

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-DDH-BR-003

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-35)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-DDH-BR-003
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.003
- Grade Unit: %
- Intercept: 7.6 m
- True Width: 2.47 m
- From: 217.75 m
- To: 225.35 m
- Intercept Depth: 186.7 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-DDH-BR-003:217.75-225.35
- Mining Method: mixed

#### Location

- Location: Tensional veins veins
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 2.47m is disclosed.

- Negative factor: Very low copper grade \(0.003% Cu\).

Evidence · table

> 0.003

Context: 217.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.47

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-36)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 94.92
- Grade Unit: g/t
- Intercept: 35.35 m
- From: 443.4 m
- To: 478.75 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:443.4-478.75
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a significant apparent width, but the lack of a true width estimate reduces confidence in its actual scale.

- Positive factor: Moderate silver grade \(94.92 g/t Ag\) over a significant apparent width.

- Negative factor: True width is pending, limiting the geological interpretation and confidence in the actual thickness.

Evidence · table

> 94.92

Context: DDH-BR-005

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-37)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.82
- Grade Unit: %
- Intercept: 35.35 m
- From: 443.4 m
- To: 478.75 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:443.4-478.75
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate lead grade over a significant apparent width, but the lack of a true width estimate reduces confidence in its actual scale.

- Positive factor: Moderate lead grade \(1.82% Pb\) over a significant apparent width.

- Negative factor: True width is pending, limiting the geological interpretation and confidence in the actual thickness.

Evidence · table

> 1.82

Context: DDH-BR-005

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-38)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.25
- Grade Unit: %
- Intercept: 35.35 m
- From: 443.4 m
- To: 478.75 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:443.4-478.75
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a weak zinc grade over a significant apparent width, but the lack of a true width estimate reduces confidence in its actual scale.

- Positive factor: Weak zinc grade \(1.25% Zn\) over a significant apparent width.

- Negative factor: True width is pending, limiting the geological interpretation and confidence in the actual thickness.

Evidence · table

> 1.25

Context: DDH-BR-005

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-39)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.233
- Grade Unit: %
- Intercept: 35.35 m
- From: 443.4 m
- To: 478.75 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:443.4-478.75
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a weak copper grade over a significant apparent width, but the lack of a true width estimate reduces confidence in its actual scale.

- Positive factor: Weak copper grade \(0.233% Cu\) over a significant apparent width.

- Negative factor: True width is pending, limiting the geological interpretation and confidence in the actual thickness.

Evidence · table

> 0.233

Context: DDH-BR-005

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-40)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 105.77
- Grade Unit: g/t
- Intercept: 4.7 m
- From: 443.4 m
- To: 448.1 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:443.4-448.1
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Moderate silver grade \(105.77 g/t Ag\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 105.77

Context: 443.40

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-41)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.25
- Grade Unit: %
- Intercept: 4.7 m
- From: 443.4 m
- To: 448.1 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:443.4-448.1
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Moderate lead grade \(1.25% Pb\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 1.25

Context: 443.40

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-42)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.25
- Grade Unit: %
- Intercept: 4.7 m
- From: 443.4 m
- To: 448.1 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:443.4-448.1
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a weak zinc grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Weak zinc grade \(1.25% Zn\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 1.25

Context: 443.40

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-43)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.171
- Grade Unit: %
- Intercept: 4.7 m
- From: 443.4 m
- To: 448.1 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:443.4-448.1
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a weak copper grade, but the pending true width reduces confidence in its actual thickness.

- Negative factor: Weak copper grade \(0.171% Cu\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 0.171

Context: 443.40

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-44)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 99.43
- Grade Unit: g/t
- Intercept: 2.65 m
- From: 451.9 m
- To: 454.55 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:451.9-454.55
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Moderate silver grade \(99.43 g/t Ag\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 99.43

Context: 451.90

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-45)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.39
- Grade Unit: %
- Intercept: 2.65 m
- From: 451.9 m
- To: 454.55 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:451.9-454.55
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Moderate lead grade \(1.39% Pb\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 1.39

Context: 451.90

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-46)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.03
- Grade Unit: %
- Intercept: 2.65 m
- From: 451.9 m
- To: 454.55 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:451.9-454.55
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a weak zinc grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Weak zinc grade \(1.03% Zn\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 1.03

Context: 451.90

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-47)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.356
- Grade Unit: %
- Intercept: 2.65 m
- From: 451.9 m
- To: 454.55 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:451.9-454.55
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate copper grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Moderate copper grade \(0.356% Cu\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 0.356

Context: 451.90

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-48)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 256.35
- Grade Unit: g/t
- Intercept: 9.2 m
- From: 469.55 m
- To: 478.75 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:469.55-478.75
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Strong silver grade \(256.35 g/t Ag\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 256.35

Context: 469.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-49)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 5.48
- Grade Unit: %
- Intercept: 9.2 m
- From: 469.55 m
- To: 478.75 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:469.55-478.75
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Moderate lead grade \(5.48% Pb\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 5.48

Context: 469.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-50)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 3.4
- Grade Unit: %
- Intercept: 9.2 m
- From: 469.55 m
- To: 478.75 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:469.55-478.75
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a weak zinc grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Weak zinc grade \(3.40% Zn\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 3.40

Context: 469.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-51)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-005
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.65
- Grade Unit: %
- Intercept: 9.2 m
- From: 469.55 m
- To: 478.75 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-005:469.55-478.75
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate copper grade, but the pending true width reduces confidence in its actual thickness.

- Positive factor: Moderate copper grade \(0.65% Cu\) for an epithermal deposit.

- Negative factor: True width is pending, limiting the geological interpretation.

Evidence · table

> 0.650

Context: 469.55

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-52)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 51.32
- Grade Unit: g/t
- Intercept: 6.4 m
- True Width: 2.19 m
- From: 239.25 m
- To: 245.65 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:239.25-245.65
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing positively to the understanding of the mineralized package.

- Positive factor: Moderate silver grade \(51.32 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 2.19m is disclosed.

Evidence · table

> 51.32

Context: DDH-BR-006

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.19

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-53)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.73
- Grade Unit: %
- Intercept: 6.4 m
- True Width: 2.19 m
- From: 239.25 m
- To: 245.65 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:239.25-245.65
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this intercept.

- Positive factor: True width of 2.19m is disclosed.

- Negative factor: Weak lead grade \(0.73% Pb\) for an epithermal deposit.

Evidence · table

> 0.73

Context: DDH-BR-006

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.19

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-54)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.94
- Grade Unit: %
- Intercept: 6.4 m
- True Width: 2.19 m
- From: 239.25 m
- To: 245.65 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:239.25-245.65
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this intercept.

- Positive factor: True width of 2.19m is disclosed.

- Negative factor: Weak zinc grade \(0.94% Zn\) for an epithermal deposit.

Evidence · table

> 0.94

Context: DDH-BR-006

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.19

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-55)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.015
- Grade Unit: %
- Intercept: 6.4 m
- True Width: 2.19 m
- From: 239.25 m
- To: 245.65 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:239.25-245.65
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this intercept.

- Positive factor: True width of 2.19m is disclosed.

- Negative factor: Very low copper grade \(0.015% Cu\).

Evidence · table

> 0.015

Context: DDH-BR-006

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.19

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-56)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 151.6
- Grade Unit: g/t
- Intercept: 1.1 m
- True Width: 0.38 m
- From: 239.25 m
- To: 240.35 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:239.25-240.35
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a narrow true width, contributing significantly to the overall intercept.

- Positive factor: Strong silver grade \(151.60 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.38m is disclosed.

Evidence · table

> 151.60

Context: 239.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.38

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-57)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.72
- Grade Unit: %
- Intercept: 1.1 m
- True Width: 0.38 m
- From: 239.25 m
- To: 240.35 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:239.25-240.35
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a narrow true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(1.72% Pb\) for an epithermal deposit.

- Positive factor: True width of 0.38m is disclosed.

Evidence · table

> 1.72

Context: 239.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.38

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-58)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.98
- Grade Unit: %
- Intercept: 1.1 m
- True Width: 0.38 m
- From: 239.25 m
- To: 240.35 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:239.25-240.35
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 0.38m is disclosed.

- Negative factor: Weak zinc grade \(0.98% Zn\) for an epithermal deposit.

Evidence · table

> 0.98

Context: 239.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.38

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-59)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.051
- Grade Unit: %
- Intercept: 1.1 m
- True Width: 0.38 m
- From: 239.25 m
- To: 240.35 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:239.25-240.35
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 0.38m is disclosed.

- Negative factor: Weak copper grade \(0.051% Cu\) for an epithermal deposit.

Evidence · table

> 0.051

Context: 239.25

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.38

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-60)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 113.64
- Grade Unit: g/t
- Intercept: 1.1 m
- True Width: 0.38 m
- From: 243.35 m
- To: 244.45 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:243.35-244.45
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, contributing significantly to the overall intercept.

- Positive factor: Moderate silver grade \(113.64 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.38m is disclosed.

Evidence · table

> 113.64

Context: 243.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.38

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-61)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.86
- Grade Unit: %
- Intercept: 1.1 m
- True Width: 0.38 m
- From: 243.35 m
- To: 244.45 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:243.35-244.45
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a narrow true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(1.86% Pb\) for an epithermal deposit.

- Positive factor: True width of 0.38m is disclosed.

Evidence · table

> 1.86

Context: 243.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.38

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-62)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 3.98
- Grade Unit: %
- Intercept: 1.1 m
- True Width: 0.38 m
- From: 243.35 m
- To: 244.45 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:243.35-244.45
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a weak zinc grade over a narrow true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Weak zinc grade \(3.98% Zn\) for an epithermal deposit.

- Positive factor: True width of 0.38m is disclosed.

Evidence · table

> 3.98

Context: 243.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.38

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-63)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-006
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.003
- Grade Unit: %
- Intercept: 1.1 m
- True Width: 0.38 m
- From: 243.35 m
- To: 244.45 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-006:243.35-244.45
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 0.38m is disclosed.

- Negative factor: Very low copper grade \(0.003% Cu\).

Evidence · table

> 0.003

Context: 243.35

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.38

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-64)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 92.35
- Grade Unit: g/t
- Intercept: 8.17 m
- True Width: 1.42 m
- From: 275.77 m
- To: 283.94 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:275.77-283.94
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing positively to the understanding of the mineralized package.

- Positive factor: Moderate silver grade \(92.35 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 1.42m is disclosed.

Evidence · table

> 92.35

Context: DDH-BR-007

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.42

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-65)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.73
- Grade Unit: %
- Intercept: 8.17 m
- True Width: 1.42 m
- From: 275.77 m
- To: 283.94 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:275.77-283.94
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this intercept.

- Positive factor: True width of 1.42m is disclosed.

- Negative factor: Weak lead grade \(0.73% Pb\) for an epithermal deposit.

Evidence · table

> 0.73

Context: DDH-BR-007

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.42

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-66)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 8.17 m
- True Width: 1.42 m
- From: 275.77 m
- To: 283.94 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:275.77-283.94
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this intercept.

- Positive factor: True width of 1.42m is disclosed.

- Negative factor: Weak zinc grade \(0.04% Zn\) for an epithermal deposit.

Evidence · table

> 0.04

Context: DDH-BR-007

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.42

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-67)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.002
- Grade Unit: %
- Intercept: 8.17 m
- True Width: 1.42 m
- From: 275.77 m
- To: 283.94 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:275.77-283.94
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this intercept.

- Positive factor: True width of 1.42m is disclosed.

- Negative factor: Very low copper grade \(0.002% Cu\).

Evidence · table

> 0.002

Context: DDH-BR-007

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.42

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-68)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 78.94
- Grade Unit: g/t
- Intercept: 3.98 m
- True Width: 0.69 m
- From: 275.77 m
- To: 279.75 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:275.77-279.75
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(78.94 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.69m is disclosed.

Evidence · table

> 78.94

Context: 275.77

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.69

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-69)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.59
- Grade Unit: %
- Intercept: 3.98 m
- True Width: 0.69 m
- From: 275.77 m
- To: 279.75 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:275.77-279.75
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 0.69m is disclosed.

- Negative factor: Weak lead grade \(0.59% Pb\) for an epithermal deposit.

Evidence · table

> 0.59

Context: 275.77

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.69

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-70)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 3.98 m
- True Width: 0.69 m
- From: 275.77 m
- To: 279.75 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:275.77-279.75
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 0.69m is disclosed.

- Negative factor: Weak zinc grade \(0.01% Zn\) for an epithermal deposit.

Evidence · table

> 0.01

Context: 275.77

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.69

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-71)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 3.98 m
- True Width: 0.69 m
- From: 275.77 m
- To: 279.75 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:275.77-279.75
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 0.69m is disclosed.

- Negative factor: Very low copper grade \(0.00% Cu\).

Evidence · table

> 0.000

Context: 275.77

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.69

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-72)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 288.67
- Grade Unit: g/t
- Intercept: 0.9 m
- True Width: 0.16 m
- From: 279.75 m
- To: 280.65 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:279.75-280.65
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a narrow true width, significantly contributing to the overall intercept's value.

- Positive factor: Strong silver grade \(288.67 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.16m is disclosed.

Evidence · table

> 288.67

Context: 279.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-73)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.19
- Grade Unit: %
- Intercept: 0.9 m
- True Width: 0.16 m
- From: 279.75 m
- To: 280.65 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:279.75-280.65
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a narrow true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(2.19% Pb\) for an epithermal deposit.

- Positive factor: True width of 0.16m is disclosed.

Evidence · table

> 2.19

Context: 279.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-74)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 0.9 m
- True Width: 0.16 m
- From: 279.75 m
- To: 280.65 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:279.75-280.65
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 0.16m is disclosed.

- Negative factor: Weak zinc grade \(0.02% Zn\) for an epithermal deposit.

Evidence · table

> 0.02

Context: 279.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-75)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 0.9 m
- True Width: 0.16 m
- From: 279.75 m
- To: 280.65 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:279.75-280.65
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 0.16m is disclosed.

- Negative factor: Very low copper grade \(0.00% Cu\).

Evidence · table

> 0.000

Context: 279.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-76)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 53.37
- Grade Unit: g/t
- Intercept: 1.8 m
- True Width: 0.31 m
- From: 280.65 m
- To: 282.45 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:280.65-282.45
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(53.37 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.31m is disclosed.

Evidence · table

> 53.37

Context: 280.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.31

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-77)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.35
- Grade Unit: %
- Intercept: 1.8 m
- True Width: 0.31 m
- From: 280.65 m
- To: 282.45 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:280.65-282.45
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 0.31m is disclosed.

- Negative factor: Weak lead grade \(0.35% Pb\) for an epithermal deposit.

Evidence · table

> 0.35

Context: 280.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.31

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-78)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1.8 m
- True Width: 0.31 m
- From: 280.65 m
- To: 282.45 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:280.65-282.45
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 0.31m is disclosed.

- Negative factor: Weak zinc grade \(0.01% Zn\) for an epithermal deposit.

Evidence · table

> 0.01

Context: 280.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.31

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-79)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-007
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.001
- Grade Unit: %
- Intercept: 1.8 m
- True Width: 0.31 m
- From: 280.65 m
- To: 282.45 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-007:280.65-282.45
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 0.31m is disclosed.

- Negative factor: Very low copper grade \(0.001% Cu\).

Evidence · table

> 0.001

Context: 280.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.31

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-80)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 43.87
- Grade Unit: g/t
- Intercept: 7.65 m
- True Width: 2.74 m
- From: 110.25 m
- To: 117.9 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:110.25-117.9
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate silver grade over a good true width, contributing positively to the understanding of the mineralized package.

- Positive factor: Moderate silver grade \(43.87 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 2.74m is disclosed.

Evidence · table

> 43.87

Context: DDH-BR-008

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.74

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-81)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.04
- Grade Unit: %
- Intercept: 7.65 m
- True Width: 2.74 m
- From: 110.25 m
- To: 117.9 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:110.25-117.9
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept shows a moderate lead grade over a good true width, contributing positively to the understanding of the mineralized package.

- Positive factor: Moderate lead grade \(2.04% Pb\) for an epithermal deposit.

- Positive factor: True width of 2.74m is disclosed.

Evidence · table

> 2.04

Context: DDH-BR-008

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.74

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-82)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.87
- Grade Unit: %
- Intercept: 7.65 m
- True Width: 2.74 m
- From: 110.25 m
- To: 117.9 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:110.25-117.9
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this intercept.

- Positive factor: Weak zinc grade \(1.87% Zn\) for an epithermal deposit.

- Positive factor: True width of 2.74m is disclosed.

Evidence · table

> 1.87

Context: DDH-BR-008

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.74

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-83)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.217
- Grade Unit: %
- Intercept: 7.65 m
- True Width: 2.74 m
- From: 110.25 m
- To: 117.9 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:110.25-117.9
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is weak but contributes to the polymetallic nature of this intercept.

- Positive factor: True width of 2.74m is disclosed.

- Negative factor: Weak copper grade \(0.217% Cu\) for an epithermal deposit.

Evidence · table

> 0.217

Context: DDH-BR-008

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.74

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-84)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 80.2
- Grade Unit: g/t
- Intercept: 13 m
- True Width: 4.66 m
- From: 135 m
- To: 148 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:135-148
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, contributing positively to the overall intercept.

- Positive factor: Moderate silver grade \(80.20 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 4.66m is disclosed.

Evidence · table

> 80.20

Context: 135.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4.66

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-85)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.05
- Grade Unit: %
- Intercept: 13 m
- True Width: 4.66 m
- From: 135 m
- To: 148 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:135-148
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a good true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(1.05% Pb\) for an epithermal deposit.

- Positive factor: True width of 4.66m is disclosed.

Evidence · table

> 1.05

Context: 135.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4.66

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-86)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.37
- Grade Unit: %
- Intercept: 13 m
- True Width: 4.66 m
- From: 135 m
- To: 148 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:135-148
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: Weak zinc grade \(2.37% Zn\) for an epithermal deposit.

- Positive factor: True width of 4.66m is disclosed.

Evidence · table

> 2.37

Context: 135.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4.66

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-87)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.011
- Grade Unit: %
- Intercept: 13 m
- True Width: 4.66 m
- From: 135 m
- To: 148 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:135-148
- Mining Method: mixed

#### Location

- Location: Undiff.
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 4.66m is disclosed.

- Negative factor: Very low copper grade \(0.011% Cu\).

Evidence · table

> 0.011

Context: 135.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4.66

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-88)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 273.82
- Grade Unit: g/t
- Intercept: 3.45 m
- True Width: 1.24 m
- From: 135 m
- To: 138.45 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:135-138.45
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval within Vein 3 shows a strong silver grade over a good true width, significantly contributing to the overall intercept's value.

- Positive factor: Strong silver grade \(273.82 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 1.24m is disclosed.

Evidence · table

> 273.82

Context: 135.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.24

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-89)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 3.22
- Grade Unit: %
- Intercept: 3.45 m
- True Width: 1.24 m
- From: 135 m
- To: 138.45 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:135-138.45
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval within Vein 3 shows a moderate lead grade over a good true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(3.22% Pb\) for an epithermal deposit.

- Positive factor: True width of 1.24m is disclosed.

Evidence · table

> 3.22

Context: 135.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.24

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-90)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 7.97
- Grade Unit: %
- Intercept: 3.45 m
- True Width: 1.24 m
- From: 135 m
- To: 138.45 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:135-138.45
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval within Vein 3 shows a moderate zinc grade over a good true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate zinc grade \(7.97% Zn\) for an epithermal deposit.

- Positive factor: True width of 1.24m is disclosed.

Evidence · table

> 7.97

Context: 135.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.24

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-91)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.016
- Grade Unit: %
- Intercept: 3.45 m
- True Width: 1.24 m
- From: 135 m
- To: 138.45 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:135-138.45
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 1.24m is disclosed.

- Negative factor: Very low copper grade \(0.016% Cu\).

Evidence · table

> 0.016

Context: 135.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.24

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-92)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 37.96
- Grade Unit: g/t
- Intercept: 1.28 m
- True Width: 0.5 m
- From: 146.72 m
- To: 148 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:146.72-148
- Mining Method: mixed

#### Location

- Location: Tensional veins veins
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a narrow true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(37.96 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.5m is disclosed.

Evidence · table

> 37.96

Context: 146.72

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.5

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-93)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.68
- Grade Unit: %
- Intercept: 1.28 m
- True Width: 0.5 m
- From: 146.72 m
- To: 148 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:146.72-148
- Mining Method: mixed

#### Location

- Location: Tensional veins veins
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 0.5m is disclosed.

- Negative factor: Weak lead grade \(0.68% Pb\) for an epithermal deposit.

Evidence · table

> 0.68

Context: 146.72

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.5

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-94)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.7
- Grade Unit: %
- Intercept: 1.28 m
- True Width: 0.5 m
- From: 146.72 m
- To: 148 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:146.72-148
- Mining Method: mixed

#### Location

- Location: Tensional veins veins
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 0.5m is disclosed.

- Negative factor: Weak zinc grade \(0.70% Zn\) for an epithermal deposit.

Evidence · table

> 0.70

Context: 146.72

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.5

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-008

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-95)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-008
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1.28 m
- True Width: 0.5 m
- From: 146.72 m
- To: 148 m
- Intercept Depth: 110.25 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-008:146.72-148
- Mining Method: mixed

#### Location

- Location: Tensional veins veins
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 0.5m is disclosed.

- Negative factor: Very low copper grade \(0.01% Cu\).

Evidence · table

> 0.010

Context: 146.72

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.5

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-96)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 38.51
- Grade Unit: g/t
- Intercept: 50.98 m
- True Width: 16.6 m
- From: 163.5 m
- To: 214.48 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:163.5-214.48
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept represents a very significant true width with a moderate silver grade, supporting the company's scalable mining strategy and indicating a broad mineralized corridor.

- Positive factor: Significant true width of 16.6m, indicating potential for bulk-style mining.

- Positive factor: Moderate silver grade \(38.51 g/t Ag\) over a very wide interval.

Evidence · table

> 38.51

Context: DDH-BR-009

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 16.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-97)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.77
- Grade Unit: %
- Intercept: 50.98 m
- True Width: 16.6 m
- From: 163.5 m
- To: 214.48 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:163.5-214.48
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is weak but contributes to the polymetallic nature of this wide intercept.

- Positive factor: Significant true width of 16.6m is disclosed.

- Negative factor: Weak lead grade \(0.77% Pb\) for an epithermal deposit.

Evidence · table

> 0.77

Context: DDH-BR-009

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 16.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-98)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.54
- Grade Unit: %
- Intercept: 50.98 m
- True Width: 16.6 m
- From: 163.5 m
- To: 214.48 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:163.5-214.48
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this wide intercept.

- Positive factor: Significant true width of 16.6m is disclosed.

- Negative factor: Weak zinc grade \(0.54% Zn\) for an epithermal deposit.

Evidence · table

> 0.54

Context: DDH-BR-009

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 16.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-99)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.007
- Grade Unit: %
- Intercept: 50.98 m
- True Width: 16.6 m
- From: 163.5 m
- To: 214.48 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:163.5-214.48
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this wide intercept.

- Positive factor: Significant true width of 16.6m is disclosed.

- Negative factor: Very low copper grade \(0.007% Cu\).

Evidence · table

> 0.007

Context: DDH-BR-009

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 16.6

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-100)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 196.82
- Grade Unit: g/t
- Intercept: 2.22 m
- True Width: 0.72 m
- From: 166.4 m
- To: 168.62 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:166.4-168.62
- Mining Method: mixed

#### Location

- Location: Tensional 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a strong silver grade over a narrow true width, contributing significantly to the overall intercept.

- Positive factor: Strong silver grade \(196.82 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 0.72m is disclosed.

Evidence · table

> 196.82

Context: 166.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.72

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-101)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 4.37
- Grade Unit: %
- Intercept: 2.22 m
- True Width: 0.72 m
- From: 166.4 m
- To: 168.62 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:166.4-168.62
- Mining Method: mixed

#### Location

- Location: Tensional 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a narrow true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(4.37% Pb\) for an epithermal deposit.

- Positive factor: True width of 0.72m is disclosed.

Evidence · table

> 4.37

Context: 166.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.72

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-102)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.52
- Grade Unit: %
- Intercept: 2.22 m
- True Width: 0.72 m
- From: 166.4 m
- To: 168.62 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:166.4-168.62
- Mining Method: mixed

#### Location

- Location: Tensional 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a weak zinc grade over a narrow true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Weak zinc grade \(2.52% Zn\) for an epithermal deposit.

- Positive factor: True width of 0.72m is disclosed.

Evidence · table

> 2.52

Context: 166.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.72

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-103)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.079
- Grade Unit: %
- Intercept: 2.22 m
- True Width: 0.72 m
- From: 166.4 m
- To: 168.62 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:166.4-168.62
- Mining Method: mixed

#### Location

- Location: Tensional 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: True width of 0.72m is disclosed.

- Negative factor: Weak copper grade \(0.079% Cu\) for an epithermal deposit.

Evidence · table

> 0.079

Context: 166.40

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.72

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-104)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 94.8
- Grade Unit: g/t
- Intercept: 5.42 m
- True Width: 1.76 m
- From: 175.65 m
- To: 181.07 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:175.65-181.07
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(94.80 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 1.76m is disclosed.

Evidence · table

> 94.80

Context: 175.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-105)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.42
- Grade Unit: %
- Intercept: 5.42 m
- True Width: 1.76 m
- From: 175.65 m
- To: 181.07 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:175.65-181.07
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a good true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(1.42% Pb\) for an epithermal deposit.

- Positive factor: True width of 1.76m is disclosed.

Evidence · table

> 1.42

Context: 175.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-106)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.37
- Grade Unit: %
- Intercept: 5.42 m
- True Width: 1.76 m
- From: 175.65 m
- To: 181.07 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:175.65-181.07
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: Weak zinc grade \(1.37% Zn\) for an epithermal deposit.

- Positive factor: True width of 1.76m is disclosed.

Evidence · table

> 1.37

Context: 175.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-107)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.001
- Grade Unit: %
- Intercept: 5.42 m
- True Width: 1.76 m
- From: 175.65 m
- To: 181.07 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:175.65-181.07
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 1.76m is disclosed.

- Negative factor: Very low copper grade \(0.001% Cu\).

Evidence · table

> 0.001

Context: 175.65

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.76

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-108)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 3.95
- Grade Unit: g/t
- Intercept: 4 m
- True Width: 1.17 m
- From: 190.75 m
- To: 194.75 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:190.75-194.75
- Mining Method: mixed

#### Location

- Location: Tensional 3-1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a very low silver grade, indicating it is not a significant contributor to the overall intercept's value.

- Positive factor: True width of 1.17m is disclosed.

- Negative factor: Very weak silver grade \(3.95 g/t Ag\) for an epithermal deposit.

Evidence · table

> 3.95

Context: 190.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.17

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-109)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 4 m
- True Width: 1.17 m
- From: 190.75 m
- To: 194.75 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:190.75-194.75
- Mining Method: mixed

#### Location

- Location: Tensional 3-1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 1.17m is disclosed.

- Negative factor: Very weak lead grade \(0.10% Pb\) for an epithermal deposit.

Evidence · table

> 0.10

Context: 190.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.17

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-110)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 4 m
- True Width: 1.17 m
- From: 190.75 m
- To: 194.75 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:190.75-194.75
- Mining Method: mixed

#### Location

- Location: Tensional 3-1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 1.17m is disclosed.

- Negative factor: Very weak zinc grade \(0.10% Zn\) for an epithermal deposit.

Evidence · table

> 0.10

Context: 190.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.17

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-111)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.003
- Grade Unit: %
- Intercept: 4 m
- True Width: 1.17 m
- From: 190.75 m
- To: 194.75 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:190.75-194.75
- Mining Method: mixed

#### Location

- Location: Tensional 3-1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 1.17m is disclosed.

- Negative factor: Very low copper grade \(0.003% Cu\).

Evidence · table

> 0.003

Context: 190.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.17

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-112)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 121.16
- Grade Unit: g/t
- Intercept: 4.68 m
- True Width: 1.37 m
- From: 209.8 m
- To: 214.48 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:209.8-214.48
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(121.16 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 1.37m is disclosed.

Evidence · table

> 121.16

Context: 209.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.37

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-113)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.44
- Grade Unit: %
- Intercept: 4.68 m
- True Width: 1.37 m
- From: 209.8 m
- To: 214.48 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:209.8-214.48
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a good true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(1.44% Pb\) for an epithermal deposit.

- Positive factor: True width of 1.37m is disclosed.

Evidence · table

> 1.44

Context: 209.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.37

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-114)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.12
- Grade Unit: %
- Intercept: 4.68 m
- True Width: 1.37 m
- From: 209.8 m
- To: 214.48 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:209.8-214.48
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is very low and does not significantly contribute to the value of this sub-interval.

- Positive factor: True width of 1.37m is disclosed.

- Negative factor: Weak zinc grade \(0.12% Zn\) for an epithermal deposit.

Evidence · table

> 0.12

Context: 209.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.37

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-115)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-009
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.006
- Grade Unit: %
- Intercept: 4.68 m
- True Width: 1.37 m
- From: 209.8 m
- To: 214.48 m
- Intercept Depth: 163.5 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-009:209.8-214.48
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 1.37m is disclosed.

- Negative factor: Very low copper grade \(0.006% Cu\).

Evidence · table

> 0.006

Context: 209.80

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.37

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-116)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 74.76
- Grade Unit: g/t
- Intercept: 20.03 m
- True Width: 6.85 m
- From: 165.04 m
- To: 185.07 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:165.04-185.07
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This intercept represents a significant true width with a moderate silver grade, supporting the company's scalable mining strategy and indicating a broad mineralized corridor.

- Positive factor: Significant true width of 6.85m, indicating potential for bulk-style mining.

- Positive factor: Moderate silver grade \(74.76 g/t Ag\) over a wide interval.

Evidence · table

> 74.76

Context: DDH-BR-010

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 6.85

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-117)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.44
- Grade Unit: %
- Intercept: 20.03 m
- True Width: 6.85 m
- From: 165.04 m
- To: 185.07 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:165.04-185.07
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The lead grade is moderate and contributes to the polymetallic nature of this wide intercept.

- Positive factor: Moderate lead grade \(2.44% Pb\) for an epithermal deposit.

- Positive factor: Significant true width of 6.85m is disclosed.

Evidence · table

> 2.44

Context: DDH-BR-010

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 6.85

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-118)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.6
- Grade Unit: %
- Intercept: 20.03 m
- True Width: 6.85 m
- From: 165.04 m
- To: 185.07 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:165.04-185.07
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this wide intercept.

- Positive factor: Significant true width of 6.85m is disclosed.

- Negative factor: Weak zinc grade \(0.60% Zn\) for an epithermal deposit.

Evidence · table

> 0.60

Context: DDH-BR-010

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 6.85

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-119)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.004
- Grade Unit: %
- Intercept: 20.03 m
- True Width: 6.85 m
- From: 165.04 m
- To: 185.07 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:165.04-185.07
- Mining Method: mixed

#### Location

- Location: Comp. pkg
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this wide intercept.

- Positive factor: Significant true width of 6.85m is disclosed.

- Negative factor: Very low copper grade \(0.004% Cu\).

Evidence · table

> 0.004

Context: DDH-BR-010

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 6.85

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-120)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 95.35
- Grade Unit: g/t
- Intercept: 5.99 m
- True Width: 1.65 m
- From: 165.04 m
- To: 171.03 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:165.04-171.03
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(95.35 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 1.65m is disclosed.

Evidence · table

> 95.35

Context: 165.04

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.65

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-121)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.98
- Grade Unit: %
- Intercept: 5.99 m
- True Width: 1.65 m
- From: 165.04 m
- To: 171.03 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:165.04-171.03
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a good true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(1.98% Pb\) for an epithermal deposit.

- Positive factor: True width of 1.65m is disclosed.

Evidence · table

> 1.98

Context: 165.04

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.65

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-122)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.59
- Grade Unit: %
- Intercept: 5.99 m
- True Width: 1.65 m
- From: 165.04 m
- To: 171.03 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:165.04-171.03
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: Weak zinc grade \(0.59% Zn\) for an epithermal deposit.

- Positive factor: True width of 1.65m is disclosed.

Evidence · table

> 0.59

Context: 165.04

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.65

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-123)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.007
- Grade Unit: %
- Intercept: 5.99 m
- True Width: 1.65 m
- From: 165.04 m
- To: 171.03 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:165.04-171.03
- Mining Method: mixed

#### Location

- Location: Vein 3
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 1.65m is disclosed.

- Negative factor: Very low copper grade \(0.007% Cu\).

Evidence · table

> 0.007

Context: 165.04

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.65

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-124)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 55.5
- Grade Unit: g/t
- Intercept: 5.35 m
- True Width: 1.47 m
- From: 171.03 m
- To: 176.38 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:171.03-176.38
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate silver grade over a good true width, contributing to the overall intercept.

- Positive factor: Moderate silver grade \(55.50 g/t Ag\) for an epithermal deposit.

- Positive factor: True width of 1.47m is disclosed.

Evidence · table

> 55.50

Context: 171.03

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.47

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-125)

Blenda Rubia · lead

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.55
- Grade Unit: %
- Intercept: 5.35 m
- True Width: 1.47 m
- From: 171.03 m
- To: 176.38 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:171.03-176.38
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: This sub-interval shows a moderate lead grade over a good true width, contributing to the polymetallic nature of the intercept.

- Positive factor: Moderate lead grade \(2.55% Pb\) for an epithermal deposit.

- Positive factor: True width of 1.47m is disclosed.

Evidence · table

> 2.55

Context: 171.03

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.47

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-126)

Blenda Rubia · zinc

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.29
- Grade Unit: %
- Intercept: 5.35 m
- True Width: 1.47 m
- From: 171.03 m
- To: 176.38 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:171.03-176.38
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The zinc grade is weak but contributes to the polymetallic nature of this sub-interval.

- Positive factor: Weak zinc grade \(1.29% Zn\) for an epithermal deposit.

- Positive factor: True width of 1.47m is disclosed.

Evidence · table

> 1.29

Context: 171.03

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.47

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-127)

Blenda Rubia · copper

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.005
- Grade Unit: %
- Intercept: 5.35 m
- True Width: 1.47 m
- From: 171.03 m
- To: 176.38 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:171.03-176.38
- Mining Method: mixed

#### Location

- Location: Veinlet fill
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: The copper grade is negligible and does not contribute to the economic value of this sub-interval.

- Positive factor: True width of 1.47m is disclosed.

- Negative factor: Very low copper grade \(0.005% Cu\).

Evidence · table

> 0.005

Context: 171.03

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.47

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### DDH-BR-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-128)

Blenda Rubia · silver

#### Identity

- Hole ID: DDH-BR-010
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 72.43
- Grade Unit: g/t
- Intercept: 8.69 m
- True Width: 3.81 m
- From: 176.38 m
- To: 185.07 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Program: mixed
- Sample Type: drill
- Group ID: DDH-BR-010:176.38-185.07
- Mining Method: mixed

#### Location

- Location: Vein 1
- Loc. Source: document

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

- Positive factor: Moderate silver grade \(72.43 g/t Ag\) for an epithermal deposit.

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.81

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-129)

Blenda Rubia · silver

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 79.94
- Grade Unit: g/t
- Intercept: 2.7 m
- From: 260.4 m
- To: 263.1 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::260.4-263.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 79.94 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 215.8 g/t·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 79.94

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-130)

Blenda Rubia · lead

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.87
- Grade Unit: %
- Intercept: 2.7 m
- From: 260.4 m
- To: 263.1 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::260.4-263.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.87 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 2.3 %·m is below.

- Negative factor: 0.87 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.87

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-131)

Blenda Rubia · zinc

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.04
- Grade Unit: %
- Intercept: 2.7 m
- From: 260.4 m
- To: 263.1 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::260.4-263.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.04 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.04 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.04

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-132)

Blenda Rubia · copper

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.002
- Grade Unit: %
- Intercept: 2.7 m
- From: 260.4 m
- To: 263.1 m
- Intercept Depth: 260.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::260.4-263.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.002 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.002 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.002

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-133)

Blenda Rubia · silver

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 289.27
- Grade Unit: g/t
- Intercept: 10.8 m
- From: 187.7 m
- To: 198.5 m
- Intercept Depth: 187.7 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::187.7-198.5
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 289.27 g/t silver is strong against the default band \[500, 200, 100, 30\] g/t. Grade×width 3124.1 g/t·m is strong.

- Positive factor: 289.27 g/t silver is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 289.27

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-134)

Blenda Rubia · lead

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.47
- Grade Unit: %
- Intercept: 10.8 m
- From: 187.7 m
- To: 198.5 m
- Intercept Depth: 187.7 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::187.7-198.5
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 2.47 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 26.7 %·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.47

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-135)

Blenda Rubia · zinc

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.34
- Grade Unit: %
- Intercept: 10.8 m
- From: 187.7 m
- To: 198.5 m
- Intercept Depth: 187.7 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::187.7-198.5
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.34 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 3.7 %·m is below.

- Negative factor: 0.34 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.34

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-136)

Blenda Rubia · copper

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.003
- Grade Unit: %
- Intercept: 10.8 m
- From: 187.7 m
- To: 198.5 m
- Intercept Depth: 187.7 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::187.7-198.5
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.003 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.003 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.003

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-137)

Blenda Rubia · silver

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 105.77
- Grade Unit: g/t
- Intercept: 4.7 m
- From: 443.4 m
- To: 448.1 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::443.4-448.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 105.77 g/t silver is moderate against the default band \[500, 200, 100, 30\] g/t. Grade×width 497.1 g/t·m is weak \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 105.77

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-138)

Blenda Rubia · lead

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.25
- Grade Unit: %
- Intercept: 4.7 m
- From: 443.4 m
- To: 448.1 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::443.4-448.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.25 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 5.9 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.25

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-139)

Blenda Rubia · zinc

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.25
- Grade Unit: %
- Intercept: 4.7 m
- From: 443.4 m
- To: 448.1 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::443.4-448.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.25 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 5.9 %·m is below.

- Negative factor: 1.25 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.25

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-140)

Blenda Rubia · copper

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.171
- Grade Unit: %
- Intercept: 4.7 m
- From: 443.4 m
- To: 448.1 m
- Intercept Depth: 443.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::443.4-448.1
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.171 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.8 %·m is below.

- Negative factor: 0.171 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.171

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-141)

Blenda Rubia · silver

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 151.6
- Grade Unit: g/t
- Intercept: 1.1 m
- From: 239.25 m
- To: 240.35 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::239.25-240.35
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 151.6 g/t silver is moderate against the default band \[500, 200, 100, 30\] g/t. Grade×width 166.8 g/t·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 151.60

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-142)

Blenda Rubia · lead

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.72
- Grade Unit: %
- Intercept: 1.1 m
- From: 239.25 m
- To: 240.35 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::239.25-240.35
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.72 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 1.9 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.72

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-143)

Blenda Rubia · zinc

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.98
- Grade Unit: %
- Intercept: 1.1 m
- From: 239.25 m
- To: 240.35 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::239.25-240.35
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.98 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 1.1 %·m is below.

- Negative factor: 0.98 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.98

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-144)

Blenda Rubia · copper

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.051
- Grade Unit: %
- Intercept: 1.1 m
- From: 239.25 m
- To: 240.35 m
- Intercept Depth: 239.25 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::239.25-240.35
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.051 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.051 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.051

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-145)

Blenda Rubia · silver

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 78.94
- Grade Unit: g/t
- Intercept: 3.98 m
- From: 275.77 m
- To: 279.75 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::275.77-279.75
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 78.94 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 314.2 g/t·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 78.94

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-146)

Blenda Rubia · lead

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.59
- Grade Unit: %
- Intercept: 3.98 m
- From: 275.77 m
- To: 279.75 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::275.77-279.75
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.59 % lead is below against the default band \[10, 6, 3, 1\] %. Grade×width 2.3 %·m is below.

- Negative factor: 0.59 % lead is below the weak threshold \(1 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.59

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-147)

Blenda Rubia · zinc

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 3.98 m
- From: 275.77 m
- To: 279.75 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::275.77-279.75
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-148)

Blenda Rubia · copper

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0
- Grade Unit: %
- Intercept: 3.98 m
- From: 275.77 m
- To: 279.75 m
- Intercept Depth: 275.77 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::275.77-279.75
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.000

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-149)

Blenda Rubia · silver

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 80.2
- Grade Unit: g/t
- Intercept: 13 m
- From: 135 m
- To: 148 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::135-148
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 80.2 g/t silver is moderate against the default band \[500, 200, 100, 30\] g/t. Grade×width 1042.6 g/t·m is moderate \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 80.20

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-150)

Blenda Rubia · lead

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.05
- Grade Unit: %
- Intercept: 13 m
- From: 135 m
- To: 148 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::135-148
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.05 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 13.7 %·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.05

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-151)

Blenda Rubia · zinc

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.37
- Grade Unit: %
- Intercept: 13 m
- From: 135 m
- To: 148 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::135-148
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 2.37 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 30.8 %·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.37

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-152)

Blenda Rubia · copper

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.011
- Grade Unit: %
- Intercept: 13 m
- From: 135 m
- To: 148 m
- Intercept Depth: 135 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::135-148
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.011 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.011 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.011

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-153)

Blenda Rubia · silver

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 196.82
- Grade Unit: g/t
- Intercept: 2.22 m
- From: 166.4 m
- To: 168.62 m
- Intercept Depth: 166.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::166.4-168.62
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 196.82 g/t silver is moderate against the default band \[500, 200, 100, 30\] g/t. Grade×width 436.9 g/t·m is weak \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 196.82

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-154)

Blenda Rubia · lead

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 4.37
- Grade Unit: %
- Intercept: 2.22 m
- From: 166.4 m
- To: 168.62 m
- Intercept Depth: 166.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::166.4-168.62
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 4.37 % lead is moderate against the default band \[10, 6, 3, 1\] %. Grade×width 9.7 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 4.37

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-155)

Blenda Rubia · zinc

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 2.52
- Grade Unit: %
- Intercept: 2.22 m
- From: 166.4 m
- To: 168.62 m
- Intercept Depth: 166.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::166.4-168.62
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 2.52 % zinc is weak against the default band \[18, 10, 5, 2\] %. Grade×width 5.6 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.52

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-156)

Blenda Rubia · copper

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.079
- Grade Unit: %
- Intercept: 2.22 m
- From: 166.4 m
- To: 168.62 m
- Intercept Depth: 166.4 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::166.4-168.62
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.079 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.079 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.079

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-157)

Blenda Rubia · silver

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: silver
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 95.35
- Grade Unit: g/t
- Intercept: 5.99 m
- From: 165.04 m
- To: 171.03 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::165.04-171.03
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 95.35 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 571.1 g/t·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 95.35

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-158)

Blenda Rubia · lead

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: lead
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 1.98
- Grade Unit: %
- Intercept: 5.99 m
- From: 165.04 m
- To: 171.03 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::165.04-171.03
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 1.98 % lead is weak against the default band \[10, 6, 3, 1\] %. Grade×width 11.9 %·m is weak.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.98

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-159)

Blenda Rubia · zinc

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: zinc
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.59
- Grade Unit: %
- Intercept: 5.99 m
- From: 165.04 m
- To: 171.03 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::165.04-171.03
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.59 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 3.5 %·m is below.

- Negative factor: 0.59 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.59

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes:

[Link to this fact](https://atlas-extractions.minestarters.com/news/silver-x-intersects-up-to-17-86-m-true-width-at-blenda-rubia-advancing-scalable--50622a67-c9eb-4c55-ac19-f6af77b2982b#fact-drill-facts-160)

Blenda Rubia · copper

#### Identity

- Hole ID: Includes:
- Project: Blenda Rubia
- Commodity: copper
- Region: peru
- Reported Region: peru
- Ticker: AGX

#### Geometry

- Grade: 0.007
- Grade Unit: %
- Intercept: 5.99 m
- From: 165.04 m
- To: 171.03 m
- Intercept Depth: 165.04 m

#### Classification

- Deposit Type: epithermal
- Sample Type: drill
- Group ID: Includes::165.04-171.03
- Mining Method: mixed

#### QA/QC

- Laboratory: Bureau Veritas \(Peru\)
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks, duplicates, check\_assays

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-04-16T00:00:00.000Z

Reasoning: Expanded from assay table. 0.007 % copper is below against the default band \[2.5, 1, 0.5, 0.25\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.007 % copper is below the weak threshold \(0.25 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.007

Context: Includes:

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
