Silverco Mining Intersects High-Grade Silver at Cusi, Including 1,100 g/t Ag over 10.3 Metres
Original announcement by tmx on
- Company
- Silverco Mining Ltd.
- Ticker
- SICO
- Exchange
- TSX
- Region
- Chihuahua, Mexico
- Primary commodity
- Silver
- Secondary commodities
- Gold, Lead, Zinc
- Document categories
- Drill results
- Extracted
- 2026-09-14 22:40:58 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Silverco Mining Ltd. announced high-grade drill results from its 100%-owned Cusi Property in Chihuahua, Mexico, as part of its 2026 diamond drill program. Key intercepts from the Promontorio zone include 1,100 g/t silver and 1.61 g/t gold over 10.3 metres in hole UGCU26-08, with a bonanza sub-interval of 6,350 g/t silver and 16.15 g/t gold over 0.7 metres. These infill and expansion results are aimed at optimizing mine planning and enhancing economics for the planned Q4 2026 production restart, also suggesting significant untested vertical extent at depth within the epithermal system.
Reasoning: The document reports multiple high-grade silver and gold intercepts, notably 1,100 g/t Ag and 1.61 g/t Au over 10.3 metres in hole UGCU26-08, including bonanza grades of 6,350 g/t Ag and 16.15 g/t Au over 0.7 metres. These results significantly exceed average resource grades and directly support the planned mine restart and resource expansion.
Positive factors
- Bonanza silver and gold grades
- Significant intercept widths
- Infill drilling supports mine plan optimization
- Potential for vertical extension of epithermal system
- True width estimated and disclosed
- Comprehensive QA/QC disclosure
Low confidence — this extraction should be reviewed alongside the original source.
Facts used in scoring: 68
Classification and evidence
Bonanza Interceptpositive
Exceptionally high-grade zone, well above the deposit-type norm.
Why it applies: Hole UGCU26-08 intersected 1,100 g/t Ag over 10.3 metres, including 6,350 g/t Ag and 16.15 g/t Au over 0.7 metres, which are exceptionally high grades well above the deposit-type norm.
Evidence · text
“UGCU26-08 - 1,100 g/t Ag, 1.61 g/t Au, 0.80% Pb and 0.52% Zn or 1,080 g/t AgEq over 10.3 metres , including 6,452 g/t AgEq over 0.7 metres”
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: The document states that true widths are estimated at ~82% on average based on vein orientation observed in drill core and modelled veins.
Evidence · text
“True widths are estimated at ~82% on average based on vein orientation observed in drill core and modelled veins”
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The release details QA/QC procedures, including the use of ALS Minerals (an ISO/IEC 17025 certified lab), certified reference standards, analytical blanks, and duplicates, with sign-off by a Qualified Person.
Evidence · text
“All diamond drill core from the 2026 program at the Cusi Project is logged, photographed, and sawn in half using a diamond blade core saw. One half of the core is submitted for geochemical analysis, while the other half is retained in secure storage for reference. Sampling intervals are determined based on geological boundaries and typically range from 0.3- 1.5 metres. Control samples comprise approximately 18% of all samples submitted, including certified reference standards, analytical blanks, field duplicates, preparation duplicates and analytical duplicates. QA/QC results are reviewed in real time, and all data is verified as meeting acceptable thresholds for accuracy, precision, and contamination before inclusion in this release. Drill core and rock samples are sent to ALS Minerals for analysis with sample preparation in Chihuahua, Mexico and analysis in North Vancouver, British Columbia. Samples remain under Company custody until delivery to ALS; sealed bags are transported by Company personnel to ALS Chihuahua. The ALS Chihuahua and North Vancouver facilities are ISO/IEC 17025 certified.”
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: The drill program is explicitly focused on infilling highly prospective areas that are planned for mining in the first year of operations and optimizing mine planning.
Evidence · text
“Drilling in this zone has been focused on infilling highly prospective areas that are planned for mining in the first year of operations which required additional drilling to be included in the resource and mine plan.”
Extracted facts
Stored fact records: 68. Some facts used in scoring do not have a stored record.
Drill Results (68)
UGCU26-05Cusi · silverGrade: 150Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 150
- Grade Unit
- g/t
- Intercept
- 2.6 m
- True Width
- 2.132 m
- From
- 36.3 m
- To
- 38.9 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:36.3-38.9
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 159
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade of 150 g/t over 2.6 metres, contributing to the infill drilling data for the Promontorio zone.
Positive factors
- Moderate silver grade
- Supports infill drilling objectives
Evidence · table
“150”
Context: 2.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.132
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · goldGrade: 0.02Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.02
- Grade Unit
- g/t
- Intercept
- 2.6 m
- True Width
- 2.132 m
- From
- 36.3 m
- To
- 38.9 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:36.3-38.9
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 159
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low gold grade of 0.02 g/t over 2.6 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.02”
Context: 2.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.132
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · leadGrade: 0.4Grade Unit: %Intercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.4
- Grade Unit
- %
- Intercept
- 2.6 m
- True Width
- 2.132 m
- From
- 36.3 m
- To
- 38.9 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:36.3-38.9
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 159
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low lead grade of 0.40% over 2.6 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.40”
Context: 2.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.132
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · zincGrade: 0.77Grade Unit: %Intercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.77
- Grade Unit
- %
- Intercept
- 2.6 m
- True Width
- 2.132 m
- From
- 36.3 m
- To
- 38.9 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:36.3-38.9
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 159
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low zinc grade of 0.77% over 2.6 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.77”
Context: 2.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.132
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · silverGrade: 247Grade Unit: g/tIntercept: 5.4 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 247
- Grade Unit
- g/t
- Intercept
- 5.4 m
- True Width
- 4.428 m
- From
- 45.3 m
- To
- 50.6 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:45.3-50.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 236
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade of 247 g/t over 5.4 metres, which is a positive result for infill drilling in the Promontorio zone.
Positive factors
- Strong silver grade
- Good intercept width
- Supports infill drilling objectives
Evidence · table
“247”
Context: 5.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.428
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · goldGrade: 0.07Grade Unit: g/tIntercept: 5.4 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.07
- Grade Unit
- g/t
- Intercept
- 5.4 m
- True Width
- 4.428 m
- From
- 45.3 m
- To
- 50.6 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:45.3-50.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 236
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low gold grade of 0.07 g/t over 5.4 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.07”
Context: 5.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.428
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · leadGrade: 0.27Grade Unit: %Intercept: 5.4 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.27
- Grade Unit
- %
- Intercept
- 5.4 m
- True Width
- 4.428 m
- From
- 45.3 m
- To
- 50.6 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:45.3-50.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 236
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low lead grade of 0.27% over 5.4 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.27”
Context: 5.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.428
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · zincGrade: 0.31Grade Unit: %Intercept: 5.4 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.31
- Grade Unit
- %
- Intercept
- 5.4 m
- True Width
- 4.428 m
- From
- 45.3 m
- To
- 50.6 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:45.3-50.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 236
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low zinc grade of 0.31% over 5.4 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.31”
Context: 5.4
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.428
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · silverGrade: 93Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 93
- Grade Unit
- g/t
- Intercept
- 1.5 m
- True Width
- 1.23 m
- From
- 112.7 m
- To
- 114.2 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:112.7-114.2
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 119
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade of 93 g/t over 1.5 metres, contributing to the infill drilling data for the Promontorio zone.
Positive factors
- Moderate silver grade
Evidence · table
“93”
Context: 1.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.23
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · goldGrade: 0.17Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.17
- Grade Unit
- g/t
- Intercept
- 1.5 m
- True Width
- 1.23 m
- From
- 112.7 m
- To
- 114.2 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:112.7-114.2
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 119
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low gold grade of 0.17 g/t over 1.5 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.17”
Context: 1.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.23
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · leadGrade: 0.43Grade Unit: %Intercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.43
- Grade Unit
- %
- Intercept
- 1.5 m
- True Width
- 1.23 m
- From
- 112.7 m
- To
- 114.2 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:112.7-114.2
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 119
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low lead grade of 0.43% over 1.5 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.43”
Context: 1.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.23
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · zincGrade: 1.09Grade Unit: %Intercept: 1.5 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.09
- Grade Unit
- %
- Intercept
- 1.5 m
- True Width
- 1.23 m
- From
- 112.7 m
- To
- 114.2 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:112.7-114.2
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 119
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low zinc grade of 1.09% over 1.5 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“1.09”
Context: 1.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.23
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · silverGrade: 76Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 76
- Grade Unit
- g/t
- Intercept
- 2.6 m
- True Width
- 2.132 m
- From
- 212 m
- To
- 214.6 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:212-214.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 194
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade of 76 g/t over 2.6 metres, contributing to the infill drilling data for the Promontorio zone.
Positive factors
- Moderate silver grade
Evidence · table
“76”
Context: 2.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.132
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · goldGrade: 0.09Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 2.6 m
- True Width
- 2.132 m
- From
- 212 m
- To
- 214.6 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:212-214.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 194
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low gold grade of 0.09 g/t over 2.6 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.09”
Context: 2.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.132
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · leadGrade: 4.4Grade Unit: %Intercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 4.4
- Grade Unit
- %
- Intercept
- 2.6 m
- True Width
- 2.132 m
- From
- 212 m
- To
- 214.6 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:212-214.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 194
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a moderate lead grade of 4.40% over 2.6 metres, contributing to the polymetallic potential of the zone.
Positive factors
- Moderate lead grade
Evidence · table
“4.40”
Context: 2.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.132
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · zincGrade: 1.71Grade Unit: %Intercept: 2.6 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.71
- Grade Unit
- %
- Intercept
- 2.6 m
- True Width
- 2.132 m
- From
- 212 m
- To
- 214.6 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:212-214.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 194
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low zinc grade of 1.71% over 2.6 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“1.71”
Context: 2.6
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.132
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · silverGrade: 106Grade Unit: g/tIntercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 106
- Grade Unit
- g/t
- Intercept
- 3.3 m
- True Width
- 2.706 m
- From
- 224 m
- To
- 227.3 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:224-227.3
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 143
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade of 106 g/t over 3.3 metres, contributing to the infill drilling data for the Promontorio zone.
Positive factors
- Moderate silver grade
- Supports infill drilling objectives
Evidence · table
“106”
Context: 3.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.706
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · goldGrade: 0.09Grade Unit: g/tIntercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.09
- Grade Unit
- g/t
- Intercept
- 3.3 m
- True Width
- 2.706 m
- From
- 224 m
- To
- 227.3 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:224-227.3
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 143
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low gold grade of 0.09 g/t over 3.3 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.09”
Context: 3.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.706
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · leadGrade: 0.63Grade Unit: %Intercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.63
- Grade Unit
- %
- Intercept
- 3.3 m
- True Width
- 2.706 m
- From
- 224 m
- To
- 227.3 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:224-227.3
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 143
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low lead grade of 0.63% over 3.3 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.63”
Context: 3.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.706
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-05Cusi · zincGrade: 1.68Grade Unit: %Intercept: 3.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-05
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.68
- Grade Unit
- %
- Intercept
- 3.3 m
- True Width
- 2.706 m
- From
- 224 m
- To
- 227.3 m
- Hole Depth
- 93 m
- Intercept Depth
- 36.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-05:224-227.3
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 293 °
- Dip
- -33 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 143
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low zinc grade of 1.68% over 3.3 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“1.68”
Context: 3.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 2.706
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-06Cusi · silverGrade: 134Grade Unit: g/tIntercept: 8.2 mView all detailsHide details
Identity
- Hole ID
- UGCU26-06
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 134
- Grade Unit
- g/t
- Intercept
- 8.2 m
- True Width
- 6.724 m
- From
- 39.9 m
- To
- 48.1 m
- Hole Depth
- 88.5 m
- Intercept Depth
- 39.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-06:39.9-48.1
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319453
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 13 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 148
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade of 134 g/t over a good width of 8.2 metres, which is a positive result for infill drilling in the Promontorio zone.
Positive factors
- Moderate silver grade
- Good intercept width
- Supports infill drilling objectives
Evidence · table
“134”
Context: 8.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.724
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-06Cusi · goldGrade: 0.11Grade Unit: g/tIntercept: 8.2 mView all detailsHide details
Identity
- Hole ID
- UGCU26-06
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.11
- Grade Unit
- g/t
- Intercept
- 8.2 m
- True Width
- 6.724 m
- From
- 39.9 m
- To
- 48.1 m
- Hole Depth
- 88.5 m
- Intercept Depth
- 39.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-06:39.9-48.1
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319453
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 13 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 148
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low gold grade of 0.11 g/t over 8.2 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.11”
Context: 8.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.724
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-06Cusi · leadGrade: 0.59Grade Unit: %Intercept: 8.2 mView all detailsHide details
Identity
- Hole ID
- UGCU26-06
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.59
- Grade Unit
- %
- Intercept
- 8.2 m
- True Width
- 6.724 m
- From
- 39.9 m
- To
- 48.1 m
- Hole Depth
- 88.5 m
- Intercept Depth
- 39.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-06:39.9-48.1
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319453
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 13 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 148
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low lead grade of 0.59% over 8.2 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.59”
Context: 8.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.724
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-06Cusi · zincGrade: 0.6Grade Unit: %Intercept: 8.2 mView all detailsHide details
Identity
- Hole ID
- UGCU26-06
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.6
- Grade Unit
- %
- Intercept
- 8.2 m
- True Width
- 6.724 m
- From
- 39.9 m
- To
- 48.1 m
- Hole Depth
- 88.5 m
- Intercept Depth
- 39.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-06:39.9-48.1
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319453
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 13 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 148
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low zinc grade of 0.60% over 8.2 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.60”
Context: 8.2
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.724
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-06Cusi · silverGrade: 443Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-06
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 443
- Grade Unit
- g/t
- Intercept
- 0.3 m
- True Width
- 0.246 m
- From
- 43.3 m
- To
- 43.6 m
- Hole Depth
- 88.5 m
- Intercept Depth
- 39.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-06:43.3-43.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319453
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 13 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 611
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a strong silver grade of 443 g/t over 0.3 metres, indicating a high-grade zone within the broader intercept.
Positive factors
- Strong silver grade
- High-grade sub-interval
Evidence · table
“443”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.246
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-06Cusi · goldGrade: 0.28Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-06
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.28
- Grade Unit
- g/t
- Intercept
- 0.3 m
- True Width
- 0.246 m
- From
- 43.3 m
- To
- 43.6 m
- Hole Depth
- 88.5 m
- Intercept Depth
- 39.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-06:43.3-43.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319453
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 13 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a low gold grade of 0.28 g/t over 0.3 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.28”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.246
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-06Cusi · leadGrade: 7.91Grade Unit: %Intercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-06
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 7.91
- Grade Unit
- %
- Intercept
- 0.3 m
- True Width
- 0.246 m
- From
- 43.3 m
- To
- 43.6 m
- Hole Depth
- 88.5 m
- Intercept Depth
- 39.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-06:43.3-43.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319453
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 13 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a strong lead grade of 7.91% over 0.3 metres, indicating a high-grade zone within the broader intercept.
Positive factors
- Strong lead grade
- High-grade sub-interval
Evidence · table
“7.91”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.246
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-06Cusi · zincGrade: 2.09Grade Unit: %Intercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-06
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 2.09
- Grade Unit
- %
- Intercept
- 0.3 m
- True Width
- 0.246 m
- From
- 43.3 m
- To
- 43.6 m
- Hole Depth
- 88.5 m
- Intercept Depth
- 39.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-06:43.3-43.6
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319453
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 13 °
- Dip
- -56 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a weak zinc grade of 2.09% over 0.3 metres, contributing to the polymetallic potential of the zone.
Positive factors
- Weak zinc grade
Evidence · table
“2.09”
Context: 0.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.246
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-07Cusi · silverGrade: 198Grade Unit: g/tIntercept: 7.7 mView all detailsHide details
Identity
- Hole ID
- UGCU26-07
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 198
- Grade Unit
- g/t
- Intercept
- 7.7 m
- True Width
- 6.314 m
- From
- 35.9 m
- To
- 43.5 m
- Hole Depth
- 81 m
- Intercept Depth
- 35.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-07:35.9-43.5
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 282 °
- Dip
- -59 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 217
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a moderate silver grade of 198 g/t over a good width of 7.7 metres, which is a positive result for infill drilling in the Promontorio zone.
Positive factors
- Moderate silver grade
- Good intercept width
- Supports infill drilling objectives
Evidence · table
“198”
Context: 7.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.314
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-07Cusi · goldGrade: 0.31Grade Unit: g/tIntercept: 7.7 mView all detailsHide details
Identity
- Hole ID
- UGCU26-07
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.31
- Grade Unit
- g/t
- Intercept
- 7.7 m
- True Width
- 6.314 m
- From
- 35.9 m
- To
- 43.5 m
- Hole Depth
- 81 m
- Intercept Depth
- 35.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-07:35.9-43.5
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 282 °
- Dip
- -59 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 217
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade of 0.31 g/t over 7.7 metres, contributing to the polymetallic potential of the zone.
Positive factors
- Weak gold grade
Evidence · table
“0.31”
Context: 7.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.314
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-07Cusi · leadGrade: 0.76Grade Unit: %Intercept: 7.7 mView all detailsHide details
Identity
- Hole ID
- UGCU26-07
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.76
- Grade Unit
- %
- Intercept
- 7.7 m
- True Width
- 6.314 m
- From
- 35.9 m
- To
- 43.5 m
- Hole Depth
- 81 m
- Intercept Depth
- 35.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-07:35.9-43.5
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 282 °
- Dip
- -59 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 217
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low lead grade of 0.76% over 7.7 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.76”
Context: 7.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.314
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-07Cusi · zincGrade: 0.59Grade Unit: %Intercept: 7.7 mView all detailsHide details
Identity
- Hole ID
- UGCU26-07
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.59
- Grade Unit
- %
- Intercept
- 7.7 m
- True Width
- 6.314 m
- From
- 35.9 m
- To
- 43.5 m
- Hole Depth
- 81 m
- Intercept Depth
- 35.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-07:35.9-43.5
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 282 °
- Dip
- -59 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 217
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low zinc grade of 0.59% over 7.7 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.59”
Context: 7.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 6.314
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-07Cusi · silverGrade: 973Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- UGCU26-07
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 973
- Grade Unit
- g/t
- Intercept
- 0.9 m
- True Width
- 0.738 m
- From
- 36.8 m
- To
- 37.7 m
- Hole Depth
- 81 m
- Intercept Depth
- 35.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-07:36.8-37.7
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 282 °
- Dip
- -59 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1002
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional silver grade of 973 g/t over 0.9 metres, indicating a very high-grade zone within the broader intercept.
Positive factors
- Exceptional silver grade
- High-grade sub-interval
Evidence · table
“973”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.738
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-07Cusi · goldGrade: 1.83Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- UGCU26-07
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.83
- Grade Unit
- g/t
- Intercept
- 0.9 m
- True Width
- 0.738 m
- From
- 36.8 m
- To
- 37.7 m
- Hole Depth
- 81 m
- Intercept Depth
- 35.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-07:36.8-37.7
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 282 °
- Dip
- -59 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a moderate gold grade of 1.83 g/t over 0.9 metres, contributing to the polymetallic potential of the zone.
Positive factors
- Moderate gold grade
Evidence · table
“1.83”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.738
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-07Cusi · leadGrade: 1.37Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- UGCU26-07
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.37
- Grade Unit
- %
- Intercept
- 0.9 m
- True Width
- 0.738 m
- From
- 36.8 m
- To
- 37.7 m
- Hole Depth
- 81 m
- Intercept Depth
- 35.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-07:36.8-37.7
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 282 °
- Dip
- -59 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a weak lead grade of 1.37% over 0.9 metres, contributing to the polymetallic potential of the zone.
Positive factors
- Weak lead grade
Evidence · table
“1.37”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.738
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-07Cusi · zincGrade: 1.39Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- UGCU26-07
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.39
- Grade Unit
- %
- Intercept
- 0.9 m
- True Width
- 0.738 m
- From
- 36.8 m
- To
- 37.7 m
- Hole Depth
- 81 m
- Intercept Depth
- 35.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-07:36.8-37.7
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319450
- Northing
- 3125951
- Elevation
- 1676 m
- Azimuth
- 282 °
- Dip
- -59 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a low zinc grade of 1.39% over 0.9 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“1.39”
Context: 0.9
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.738
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · silverGrade: 1100Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1100
- Grade Unit
- g/t
- Intercept
- 10.3 m
- True Width
- 8.446 m
- From
- 46.2 m
- To
- 56.5 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:46.2-56.5
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1080
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows an exceptional silver grade of 1,100 g/t over 10.3 metres, representing a bonanza grade that significantly enhances the project's economics and supports mine planning.
Positive factors
- Exceptional silver grade
- Significant intercept width
- Bonanza intercept
- Supports mine plan optimization
Evidence · table
“1,100”
Context: 10.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.446
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · goldGrade: 1.61Grade Unit: g/tIntercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.61
- Grade Unit
- g/t
- Intercept
- 10.3 m
- True Width
- 8.446 m
- From
- 46.2 m
- To
- 56.5 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:46.2-56.5
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1080
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a moderate gold grade of 1.61 g/t over 10.3 metres, adding significant value to the polymetallic intercept.
Positive factors
- Moderate gold grade
- Significant intercept width
Evidence · table
“1.61”
Context: 10.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.446
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · leadGrade: 0.8Grade Unit: %Intercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.8
- Grade Unit
- %
- Intercept
- 10.3 m
- True Width
- 8.446 m
- From
- 46.2 m
- To
- 56.5 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:46.2-56.5
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1080
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low lead grade of 0.80% over 10.3 metres, contributing to the overall polymetallic context.
Evidence · table
“0.80”
Context: 10.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.446
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · zincGrade: 0.52Grade Unit: %Intercept: 10.3 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.52
- Grade Unit
- %
- Intercept
- 10.3 m
- True Width
- 8.446 m
- From
- 46.2 m
- To
- 56.5 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:46.2-56.5
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1080
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low zinc grade of 0.52% over 10.3 metres, contributing to the overall polymetallic context.
Evidence · table
“0.52”
Context: 10.3
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 8.446
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · silverGrade: 3199Grade Unit: g/tIntercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 3199
- Grade Unit
- g/t
- Intercept
- 2.1 m
- True Width
- 1.722 m
- From
- 51 m
- To
- 53.1 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:51-53.1
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3178
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional silver grade of 3,199 g/t over 2.1 metres, representing a bonanza grade that significantly enhances the project's economics.
Positive factors
- Exceptional silver grade
- Bonanza intercept
- High-grade sub-interval
Evidence · table
“3,199”
Context: 2.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.722
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · goldGrade: 6.01Grade Unit: g/tIntercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 6.01
- Grade Unit
- g/t
- Intercept
- 2.1 m
- True Width
- 1.722 m
- From
- 51 m
- To
- 53.1 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:51-53.1
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional gold grade of 6.01 g/t over 2.1 metres, adding significant value to the polymetallic intercept.
Positive factors
- Exceptional gold grade
- High-grade sub-interval
Evidence · table
“6.01”
Context: 2.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.722
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · leadGrade: 1.69Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.69
- Grade Unit
- %
- Intercept
- 2.1 m
- True Width
- 1.722 m
- From
- 51 m
- To
- 53.1 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:51-53.1
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a weak lead grade of 1.69% over 2.1 metres, contributing to the polymetallic potential of the zone.
Positive factors
- Weak lead grade
Evidence · table
“1.69”
Context: 2.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.722
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · zincGrade: 1.26Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.26
- Grade Unit
- %
- Intercept
- 2.1 m
- True Width
- 1.722 m
- From
- 51 m
- To
- 53.1 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:51-53.1
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a low zinc grade of 1.26% over 2.1 metres, contributing to the overall polymetallic context.
Evidence · table
“1.26”
Context: 2.1
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 1.722
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · silverGrade: 6350Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 6350
- Grade Unit
- g/t
- Intercept
- 0.7 m
- True Width
- 0.574 m
- From
- 52 m
- To
- 52.7 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:52-52.7
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6452
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional silver grade of 6,350 g/t over 0.7 metres, representing a bonanza grade that is highly material and significantly enhances the project's economics.
Positive factors
- Exceptional silver grade
- Bonanza intercept
- Highest-grade sub-interval
Evidence · table
“6,350”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.574
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · goldGrade: 16.15Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 16.15
- Grade Unit
- g/t
- Intercept
- 0.7 m
- True Width
- 0.574 m
- From
- 52 m
- To
- 52.7 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:52-52.7
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows an exceptional gold grade of 16.15 g/t over 0.7 metres, representing a bonanza grade that is highly material and significantly enhances the project's economics.
Positive factors
- Exceptional gold grade
- Bonanza intercept
- Highest-grade sub-interval
Evidence · table
“16.15”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.574
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · leadGrade: 2.49Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 2.49
- Grade Unit
- %
- Intercept
- 0.7 m
- True Width
- 0.574 m
- From
- 52 m
- To
- 52.7 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:52-52.7
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a weak lead grade of 2.49% over 0.7 metres, contributing to the polymetallic potential of the zone.
Positive factors
- Weak lead grade
Evidence · table
“2.49”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.574
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · zincGrade: 2.14Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 2.14
- Grade Unit
- %
- Intercept
- 0.7 m
- True Width
- 0.574 m
- From
- 52 m
- To
- 52.7 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:52-52.7
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This sub-interval shows a weak zinc grade of 2.14% over 0.7 metres, contributing to the polymetallic potential of the zone.
Positive factors
- Weak zinc grade
Evidence · table
“2.14”
Context: 0.7
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 0.574
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · silverGrade: 234Grade Unit: g/tIntercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 234
- Grade Unit
- g/t
- Intercept
- 5.5 m
- True Width
- 4.51 m
- From
- 78.3 m
- To
- 83.8 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:78.3-83.8
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 260
- Metal Eq. Unit
- g/t AgEq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a strong silver grade of 234 g/t over 5.5 metres, which is a positive result for infill drilling in the Promontorio zone.
Positive factors
- Strong silver grade
- Good intercept width
- Supports infill drilling objectives
Evidence · table
“234”
Context: 5.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.51
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · goldGrade: 0.89Grade Unit: g/tIntercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.89
- Grade Unit
- g/t
- Intercept
- 5.5 m
- True Width
- 4.51 m
- From
- 78.3 m
- To
- 83.8 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:78.3-83.8
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 260
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a weak gold grade of 0.89 g/t over 5.5 metres, contributing to the polymetallic potential of the zone.
Positive factors
- Weak gold grade
Evidence · table
“0.89”
Context: 5.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.51
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · leadGrade: 0.34Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.34
- Grade Unit
- %
- Intercept
- 5.5 m
- True Width
- 4.51 m
- From
- 78.3 m
- To
- 83.8 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:78.3-83.8
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 260
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low lead grade of 0.34% over 5.5 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.34”
Context: 5.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.51
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
UGCU26-08Cusi · zincGrade: 0.36Grade Unit: %Intercept: 5.5 mView all detailsHide details
Identity
- Hole ID
- UGCU26-08
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.36
- Grade Unit
- %
- Intercept
- 5.5 m
- True Width
- 4.51 m
- From
- 78.3 m
- To
- 83.8 m
- Hole Depth
- 159 m
- Intercept Depth
- 46.2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- drill
- Group ID
- UGCU26-08:78.3-83.8
- Mining Method
- underground
Location
- Location
- Promontorio
- Easting
- 319457
- Northing
- 3125951
- Elevation
- 1677 m
- Azimuth
- 356 °
- Dip
- -39 °
- Loc. Confidence
- high
- Loc. Source
- document
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 260
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: This intercept shows a low zinc grade of 0.36% over 5.5 metres, which is not significant on its own but contributes to the overall polymetallic context.
Evidence · table
“0.36”
Context: 5.5
Tags used in scoring
True Width Disclosedpositive
Actual thickness perpendicular to structure is stated, not just downhole length.
Why it applies: true_width_m is 4.51
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
incl.Cusi · silverGrade: 443Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 443
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 43.3 m
- To
- 43.6 m
- Intercept Depth
- 43.3 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:43.3-43.6
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 611
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 443 g/t silver is strong against the default band [500, 200, 100, 30] g/t. Grade×width 132.9 g/t·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 443 g/t silver is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“443”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · goldGrade: 0.28Grade Unit: g/tIntercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 0.28
- Grade Unit
- g/t
- Intercept
- 0.3 m
- From
- 43.3 m
- To
- 43.6 m
- Intercept Depth
- 43.3 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:43.3-43.6
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 611
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 0.28 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 0.1 g/t·m is below.
Negative factors
- 0.28 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.28”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · leadGrade: 7.91Grade Unit: %Intercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 7.91
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 43.3 m
- To
- 43.6 m
- Intercept Depth
- 43.3 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:43.3-43.6
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 611
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 7.91 % lead is strong against the default band [10, 6, 3, 1] %. Grade×width 2.4 %·m is below (grade alone is strong; the better of the two is used).
Positive factors
- 7.91 % lead is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“7.91”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · zincGrade: 2.09Grade Unit: %Intercept: 0.3 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 2.09
- Grade Unit
- %
- Intercept
- 0.3 m
- From
- 43.3 m
- To
- 43.6 m
- Intercept Depth
- 43.3 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:43.3-43.6
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 611
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 2.09 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 0.6 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.09”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · silverGrade: 973Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 973
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 36.8 m
- To
- 37.7 m
- Intercept Depth
- 36.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:36.8-37.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1002
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 973 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 875.7 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 973 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“973”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · goldGrade: 1.83Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.83
- Grade Unit
- g/t
- Intercept
- 0.9 m
- From
- 36.8 m
- To
- 37.7 m
- Intercept Depth
- 36.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:36.8-37.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1002
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 1.83 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 1.6 g/t·m is below.
Negative factors
- 1.83 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.83”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · leadGrade: 1.37Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.37
- Grade Unit
- %
- Intercept
- 0.9 m
- From
- 36.8 m
- To
- 37.7 m
- Intercept Depth
- 36.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:36.8-37.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1002
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 1.37 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 1.2 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.37”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · zincGrade: 1.39Grade Unit: %Intercept: 0.9 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.39
- Grade Unit
- %
- Intercept
- 0.9 m
- From
- 36.8 m
- To
- 37.7 m
- Intercept Depth
- 36.8 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:36.8-37.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 1002
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 1.39 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.3 %·m is below.
Negative factors
- 1.39 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.39”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · silverGrade: 3199Grade Unit: g/tIntercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 3199
- Grade Unit
- g/t
- Intercept
- 2.1 m
- From
- 51 m
- To
- 53.1 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:51-53.1
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3178
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 3199 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 6717.9 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 3199 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3,199”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · goldGrade: 6.01Grade Unit: g/tIntercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 6.01
- Grade Unit
- g/t
- Intercept
- 2.1 m
- From
- 51 m
- To
- 53.1 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:51-53.1
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3178
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 6.01 g/t gold is moderate against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 12.6 g/t·m is weak (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.01”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · leadGrade: 1.69Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.69
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 51 m
- To
- 53.1 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:51-53.1
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3178
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 1.69 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 3.5 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.69”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · zincGrade: 1.26Grade Unit: %Intercept: 2.1 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 1.26
- Grade Unit
- %
- Intercept
- 2.1 m
- From
- 51 m
- To
- 53.1 m
- Intercept Depth
- 51 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:51-53.1
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3178
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 1.26 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 2.6 %·m is below.
Negative factors
- 1.26 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.26”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · silverGrade: 6350Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- silver
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 6350
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 52 m
- To
- 52.7 m
- Intercept Depth
- 52 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:52-52.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6452
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 6350 g/t silver is exceptional against the default band [500, 200, 100, 30] g/t. Grade×width 4445.0 g/t·m is strong (grade alone is exceptional; the better of the two is used).
Positive factors
- 6350 g/t silver is exceptional on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6,350”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · goldGrade: 16.15Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- gold
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 16.15
- Grade Unit
- g/t
- Intercept
- 0.7 m
- From
- 52 m
- To
- 52.7 m
- Intercept Depth
- 52 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:52-52.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6452
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 16.15 g/t gold is exceptional against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 11.3 g/t·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 16.15 g/t gold is exceptional on the underground mining band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“16.15”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · leadGrade: 2.49Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- lead
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 2.49
- Grade Unit
- %
- Intercept
- 0.7 m
- From
- 52 m
- To
- 52.7 m
- Intercept Depth
- 52 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:52-52.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6452
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 2.49 % lead is weak against the default band [10, 6, 3, 1] %. Grade×width 1.7 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.49”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
incl.Cusi · zincGrade: 2.14Grade Unit: %Intercept: 0.7 mView all detailsHide details
Identity
- Hole ID
- incl.
- Project
- Cusi
- Commodity
- zinc
- Region
- mexico
- Reported Region
- mexico
- Ticker
- SICO
Geometry
- Grade
- 2.14
- Grade Unit
- %
- Intercept
- 0.7 m
- From
- 52 m
- To
- 52.7 m
- Intercept Depth
- 52 m
Classification
- Deposit Type
- epithermal
- Sample Type
- drill
- Group ID
- incl.:52-52.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS Minerals
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 6452
- Metal Eq. Unit
- g/t Eq
- Assumptions Disclosed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-07T00:00:00.000Z
Reasoning: Expanded from assay table. 2.14 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 1.5 %·m is below (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.14”
Context: incl.
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.