Total Metals Reports Positive Results at its Electrolode Critical Metals Project - Including High-Grade intercepts up to 38.20% Zinc over 0.42m and 3.59% Copper over 1.91m

Original announcement by tmx on

Company
Total Metals Corp.
Ticker
TT
Exchange
TSX
Region
Northwestern Ontario
Primary commodity
Zinc
Secondary commodities
Copper, Gold, Silver, Gallium, Indium
Document categories
Drill results, Resource update
Extracted
2026-09-17 02:46:32 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Total Metals Corp. announced positive drill results from its winter 2026 program at the Electrolode Critical Metals Project in Northwestern Ontario. Several intercepts in the Arrow Zone and its hanging wall returned high-grade zinc and copper, with subintervals reaching up to 38.20% Zinc over 0.42m and 3.59% Copper over 1.91m, significantly exceeding the project's current inferred resource grades. The company also noted elevated gallium and indium values, indicating potential for additional critical metals, and confirmed robust QA/QC procedures.

Reasoning: The announcement reports new high-grade drill results for zinc and copper from the Electrolode project, with several intercepts significantly exceeding the existing inferred resource grades. The presence of elevated gallium and indium adds potential value. Strong QA/QC procedures support the results. While some targets were downgraded, the overall results are highly positive for the project's potential.

Positive factors

  • High-grade zinc and copper intercepts significantly exceed the existing resource grade.
  • Discovery of a highly mineralized zone in the hanging wall with significant copper values.
  • Elevated gallium and indium values indicate potential for additional critical metals.
  • Comprehensive QA/QC procedures including certified lab, standards, blanks, and third-party verification.

Negative factors

  • True thickness is estimated, not precisely measured for all intercepts.
  • Garnet Zone drilling downgraded potential for continuity with Arrow Zone.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 141

Extracted facts

Stored fact records: 141. Some facts used in scoring do not have a stored record.

Drill Results (141)

EL-26-002Electrolode Critical Metals · zincGrade: 0.91Grade Unit: %Intercept: 2.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.91
Grade Unit
%
Intercept
2.55 m
True Width
2.04 m
From
335.25 m
To
337.8 m
Hole Depth
405 m
Intercept Depth
335.25 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:335.25-337.8
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

“0.91”

Context: 2.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.04

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · copperGrade: 0.02Grade Unit: %Intercept: 2.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.02
Grade Unit
%
Intercept
2.55 m
True Width
2.04 m
From
335.25 m
To
337.8 m
Hole Depth
405 m
Intercept Depth
335.25 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:335.25-337.8
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

“0.02”

Context: 2.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.04

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · goldGrade: 0.16Grade Unit: g/tIntercept: 2.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.16
Grade Unit
g/t
Intercept
2.55 m
True Width
2.04 m
From
335.25 m
To
337.8 m
Hole Depth
405 m
Intercept Depth
335.25 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:335.25-337.8
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

“0.16”

Context: 2.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.04

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · silverGrade: 24.93Grade Unit: g/tIntercept: 2.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
24.93
Grade Unit
g/t
Intercept
2.55 m
True Width
2.04 m
From
335.25 m
To
337.8 m
Hole Depth
405 m
Intercept Depth
335.25 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:335.25-337.8
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

“24.93”

Context: 2.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.04

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · galliumGrade: 49.14Grade Unit: ppmIntercept: 2.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
49.14
Grade Unit
ppm
Intercept
2.55 m
True Width
2.04 m
From
335.25 m
To
337.8 m
Hole Depth
405 m
Intercept Depth
335.25 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:335.25-337.8
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“49.14”

Context: 2.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.04

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · indiumGrade: 0.34Grade Unit: ppmIntercept: 2.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.34
Grade Unit
ppm
Intercept
2.55 m
True Width
2.04 m
From
335.25 m
To
337.8 m
Hole Depth
405 m
Intercept Depth
335.25 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:335.25-337.8
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“0.34”

Context: 2.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.04

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · zincGrade: 0.95Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.95
Grade Unit
%
Intercept
1.9 m
True Width
1.52 m
From
369 m
To
370.9 m
Hole Depth
405 m
Intercept Depth
369 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:369-370.9
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

“0.95”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · copperGrade: 0.09Grade Unit: %Intercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.09
Grade Unit
%
Intercept
1.9 m
True Width
1.52 m
From
369 m
To
370.9 m
Hole Depth
405 m
Intercept Depth
369 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:369-370.9
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

“0.09”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · goldGrade: 0.03Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
1.9 m
True Width
1.52 m
From
369 m
To
370.9 m
Hole Depth
405 m
Intercept Depth
369 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:369-370.9
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

“0.03”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · silverGrade: 1.21Grade Unit: g/tIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.21
Grade Unit
g/t
Intercept
1.9 m
True Width
1.52 m
From
369 m
To
370.9 m
Hole Depth
405 m
Intercept Depth
369 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:369-370.9
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

“1.21”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · galliumGrade: 80.06Grade Unit: ppmIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
80.06
Grade Unit
ppm
Intercept
1.9 m
True Width
1.52 m
From
369 m
To
370.9 m
Hole Depth
405 m
Intercept Depth
369 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:369-370.9
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“80.06”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · indiumGrade: 4.99Grade Unit: ppmIntercept: 1.9 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
4.99
Grade Unit
ppm
Intercept
1.9 m
True Width
1.52 m
From
369 m
To
370.9 m
Hole Depth
405 m
Intercept Depth
369 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:369-370.9
Mining Method
unknown

Location

Location
HW
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“4.99”

Context: 1.90

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.52

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · zincGrade: 5.1Grade Unit: %Intercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
5.1
Grade Unit
%
Intercept
4.55 m
True Width
3.64 m
From
374.85 m
To
379.4 m
Hole Depth
405 m
Intercept Depth
374.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:374.85-379.4
Mining Method
unknown

Location

Location
Arrow
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Significant zinc intercept in the Arrow Zone, exceeding the average resource grade.

Positive factors

  • Strong zinc grade for VMS deposit.

Evidence · table

“5.10”

Context: 4.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.64

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · copperGrade: 0.5Grade Unit: %Intercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.5
Grade Unit
%
Intercept
4.55 m
True Width
3.64 m
From
374.85 m
To
379.4 m
Hole Depth
405 m
Intercept Depth
374.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:374.85-379.4
Mining Method
unknown

Location

Location
Arrow
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

Positive factors

  • Moderate copper grade for VMS deposit.

Evidence · table

“0.50”

Context: 4.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.64

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · goldGrade: 0.41Grade Unit: g/tIntercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.41
Grade Unit
g/t
Intercept
4.55 m
True Width
3.64 m
From
374.85 m
To
379.4 m
Hole Depth
405 m
Intercept Depth
374.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:374.85-379.4
Mining Method
unknown

Location

Location
Arrow
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

“0.41”

Context: 4.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.64

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · silverGrade: 18.21Grade Unit: g/tIntercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
18.21
Grade Unit
g/t
Intercept
4.55 m
True Width
3.64 m
From
374.85 m
To
379.4 m
Hole Depth
405 m
Intercept Depth
374.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:374.85-379.4
Mining Method
unknown

Location

Location
Arrow
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Arrow Zone.

Evidence · table

“18.21”

Context: 4.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.64

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · galliumGrade: 71.11Grade Unit: ppmIntercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
71.11
Grade Unit
ppm
Intercept
4.55 m
True Width
3.64 m
From
374.85 m
To
379.4 m
Hole Depth
405 m
Intercept Depth
374.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:374.85-379.4
Mining Method
unknown

Location

Location
Arrow
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“71.11”

Context: 4.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.64

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-002Electrolode Critical Metals · indiumGrade: 40.15Grade Unit: ppmIntercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-002
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
40.15
Grade Unit
ppm
Intercept
4.55 m
True Width
3.64 m
From
374.85 m
To
379.4 m
Hole Depth
405 m
Intercept Depth
374.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-002:374.85-379.4
Mining Method
unknown

Location

Location
Arrow
Easting
512588
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.5 m
Azimuth
135 °
Dip
-70 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“40.15”

Context: 4.55

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.64

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · zincGrade: 1.13Grade Unit: %Intercept: 0.86 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.13
Grade Unit
%
Intercept
0.86 m
True Width
0.688 m
From
330.14 m
To
331 m
Hole Depth
387 m
Intercept Depth
330.14 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:330.14-331
Mining Method
unknown

Location

Location
HW
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

“1.13”

Context: 0.86

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.688

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · copperGrade: 0.19Grade Unit: %Intercept: 0.86 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.19
Grade Unit
%
Intercept
0.86 m
True Width
0.688 m
From
330.14 m
To
331 m
Hole Depth
387 m
Intercept Depth
330.14 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:330.14-331
Mining Method
unknown

Location

Location
HW
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

“0.19”

Context: 0.86

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.688

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · goldGrade: 0.1Grade Unit: g/tIntercept: 0.86 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
0.86 m
True Width
0.688 m
From
330.14 m
To
331 m
Hole Depth
387 m
Intercept Depth
330.14 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:330.14-331
Mining Method
unknown

Location

Location
HW
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

“0.10”

Context: 0.86

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.688

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · silverGrade: 5.03Grade Unit: g/tIntercept: 0.86 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
5.03
Grade Unit
g/t
Intercept
0.86 m
True Width
0.688 m
From
330.14 m
To
331 m
Hole Depth
387 m
Intercept Depth
330.14 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:330.14-331
Mining Method
unknown

Location

Location
HW
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

“5.03”

Context: 0.86

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.688

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · galliumGrade: 63.3Grade Unit: ppmIntercept: 0.86 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
63.3
Grade Unit
ppm
Intercept
0.86 m
True Width
0.688 m
From
330.14 m
To
331 m
Hole Depth
387 m
Intercept Depth
330.14 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:330.14-331
Mining Method
unknown

Location

Location
HW
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“63.30”

Context: 0.86

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.688

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · indiumGrade: 16.2Grade Unit: ppmIntercept: 0.86 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
16.2
Grade Unit
ppm
Intercept
0.86 m
True Width
0.688 m
From
330.14 m
To
331 m
Hole Depth
387 m
Intercept Depth
330.14 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:330.14-331
Mining Method
unknown

Location

Location
HW
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“16.20”

Context: 0.86

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.688

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · zincGrade: 7Grade Unit: %Intercept: 7.18 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
7
Grade Unit
%
Intercept
7.18 m
True Width
5.744 m
From
341 m
To
348.18 m
Hole Depth
387 m
Intercept Depth
341 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:341-348.18
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Significant zinc intercept in the Arrow Zone, exceeding the average resource grade over a good length.

Positive factors

  • Strong zinc grade for VMS deposit.
  • Good intercept length.

Evidence · table

“7.00”

Context: 7.18

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.744

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · copperGrade: 0.47Grade Unit: %Intercept: 7.18 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.47
Grade Unit
%
Intercept
7.18 m
True Width
5.744 m
From
341 m
To
348.18 m
Hole Depth
387 m
Intercept Depth
341 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:341-348.18
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

Positive factors

  • Moderate copper grade for VMS deposit.

Evidence · table

“0.47”

Context: 7.18

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.744

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · goldGrade: 0.25Grade Unit: g/tIntercept: 7.18 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.25
Grade Unit
g/t
Intercept
7.18 m
True Width
5.744 m
From
341 m
To
348.18 m
Hole Depth
387 m
Intercept Depth
341 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:341-348.18
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

“0.25”

Context: 7.18

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.744

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · silverGrade: 32.73Grade Unit: g/tIntercept: 7.18 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
32.73
Grade Unit
g/t
Intercept
7.18 m
True Width
5.744 m
From
341 m
To
348.18 m
Hole Depth
387 m
Intercept Depth
341 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:341-348.18
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Arrow Zone.

Evidence · table

“32.73”

Context: 7.18

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.744

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · galliumGrade: 83.29Grade Unit: ppmIntercept: 7.18 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
83.29
Grade Unit
ppm
Intercept
7.18 m
True Width
5.744 m
From
341 m
To
348.18 m
Hole Depth
387 m
Intercept Depth
341 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:341-348.18
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“83.29”

Context: 7.18

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.744

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · indiumGrade: 23.78Grade Unit: ppmIntercept: 7.18 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
23.78
Grade Unit
ppm
Intercept
7.18 m
True Width
5.744 m
From
341 m
To
348.18 m
Hole Depth
387 m
Intercept Depth
341 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:341-348.18
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“23.78”

Context: 7.18

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 5.744

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · zincGrade: 20.14Grade Unit: %Intercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
20.14
Grade Unit
%
Intercept
1.7 m
True Width
1.36 m
From
342.8 m
To
344.5 m
Hole Depth
387 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:342.8-344.5
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade zinc intercept in the Arrow Zone, significantly above the average resource grade.

Positive factors

  • Exceptional zinc grade for VMS deposit.
  • Bonanza Intercept

Evidence · table

“20.14”

Context: 1.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · copperGrade: 0.89Grade Unit: %Intercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.89
Grade Unit
%
Intercept
1.7 m
True Width
1.36 m
From
342.8 m
To
344.5 m
Hole Depth
387 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:342.8-344.5
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

Positive factors

  • Moderate copper grade for VMS deposit.

Evidence · table

“0.89”

Context: 1.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · goldGrade: 0.37Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.37
Grade Unit
g/t
Intercept
1.7 m
True Width
1.36 m
From
342.8 m
To
344.5 m
Hole Depth
387 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:342.8-344.5
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

“0.37”

Context: 1.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · silverGrade: 112.29Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
112.29
Grade Unit
g/t
Intercept
1.7 m
True Width
1.36 m
From
342.8 m
To
344.5 m
Hole Depth
387 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:342.8-344.5
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate silver intercept in the Arrow Zone.

Positive factors

  • Moderate silver grade for VMS deposit.

Evidence · table

“112.29”

Context: 1.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · galliumGrade: 105.92Grade Unit: ppmIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
105.92
Grade Unit
ppm
Intercept
1.7 m
True Width
1.36 m
From
342.8 m
To
344.5 m
Hole Depth
387 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:342.8-344.5
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“105.92”

Context: 1.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-003AElectrolode Critical Metals · indiumGrade: 38.58Grade Unit: ppmIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-003A
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
38.58
Grade Unit
ppm
Intercept
1.7 m
True Width
1.36 m
From
342.8 m
To
344.5 m
Hole Depth
387 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-003A:342.8-344.5
Mining Method
unknown

Location

Location
Arrow
Easting
512589
Northing
5649252
CRS
NAD83 / Zone 15
Elevation
402.6 m
Azimuth
134 °
Dip
-64 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“38.58”

Context: 1.70

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.36

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · zincGrade: 0.99Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.99
Grade Unit
%
Intercept
1.5 m
True Width
1.2 m
From
348.4 m
To
349.9 m
Hole Depth
411 m
Intercept Depth
348.4 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:348.4-349.9
Mining Method
unknown

Location

Location
HW
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

“0.99”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · copperGrade: 0.26Grade Unit: %Intercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.26
Grade Unit
%
Intercept
1.5 m
True Width
1.2 m
From
348.4 m
To
349.9 m
Hole Depth
411 m
Intercept Depth
348.4 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:348.4-349.9
Mining Method
unknown

Location

Location
HW
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

“0.26”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · goldGrade: 0.06Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.06
Grade Unit
g/t
Intercept
1.5 m
True Width
1.2 m
From
348.4 m
To
349.9 m
Hole Depth
411 m
Intercept Depth
348.4 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:348.4-349.9
Mining Method
unknown

Location

Location
HW
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

“0.06”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · silverGrade: 2.41Grade Unit: g/tIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
2.41
Grade Unit
g/t
Intercept
1.5 m
True Width
1.2 m
From
348.4 m
To
349.9 m
Hole Depth
411 m
Intercept Depth
348.4 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:348.4-349.9
Mining Method
unknown

Location

Location
HW
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

“2.41”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · galliumGrade: 38.53Grade Unit: ppmIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
38.53
Grade Unit
ppm
Intercept
1.5 m
True Width
1.2 m
From
348.4 m
To
349.9 m
Hole Depth
411 m
Intercept Depth
348.4 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:348.4-349.9
Mining Method
unknown

Location

Location
HW
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“38.53”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · indiumGrade: 0.1Grade Unit: ppmIntercept: 1.5 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.1
Grade Unit
ppm
Intercept
1.5 m
True Width
1.2 m
From
348.4 m
To
349.9 m
Hole Depth
411 m
Intercept Depth
348.4 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:348.4-349.9
Mining Method
unknown

Location

Location
HW
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“0.10”

Context: 1.50

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.2

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · zincGrade: 3.85Grade Unit: %Intercept: 9.75 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.85
Grade Unit
%
Intercept
9.75 m
True Width
7.8 m
From
371.8 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
371.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:371.8-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate zinc intercept in the Arrow Zone over a good length.

Positive factors

  • Moderate zinc grade for VMS deposit.
  • Good intercept length.

Evidence · table

“3.85”

Context: 9.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · copperGrade: 0.5Grade Unit: %Intercept: 9.75 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.5
Grade Unit
%
Intercept
9.75 m
True Width
7.8 m
From
371.8 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
371.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:371.8-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

Positive factors

  • Moderate copper grade for VMS deposit.

Evidence · table

“0.50”

Context: 9.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · goldGrade: 0.19Grade Unit: g/tIntercept: 9.75 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.19
Grade Unit
g/t
Intercept
9.75 m
True Width
7.8 m
From
371.8 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
371.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:371.8-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

“0.19”

Context: 9.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · silverGrade: 18.59Grade Unit: g/tIntercept: 9.75 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
18.59
Grade Unit
g/t
Intercept
9.75 m
True Width
7.8 m
From
371.8 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
371.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:371.8-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Arrow Zone.

Evidence · table

“18.59”

Context: 9.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · galliumGrade: 40.9Grade Unit: ppmIntercept: 9.75 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
40.9
Grade Unit
ppm
Intercept
9.75 m
True Width
7.8 m
From
371.8 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
371.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:371.8-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“40.90”

Context: 9.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · indiumGrade: 11.45Grade Unit: ppmIntercept: 9.75 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
11.45
Grade Unit
ppm
Intercept
9.75 m
True Width
7.8 m
From
371.8 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
371.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:371.8-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“11.45”

Context: 9.75

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 7.8

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · zincGrade: 20.44Grade Unit: %Intercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
20.44
Grade Unit
%
Intercept
1.45 m
True Width
1.16 m
From
380.1 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:380.1-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade zinc intercept in the Arrow Zone, significantly above the average resource grade.

Positive factors

  • Exceptional zinc grade for VMS deposit.
  • Bonanza Intercept

Evidence · table

“20.44”

Context: 1.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.16

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · copperGrade: 0.98Grade Unit: %Intercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.98
Grade Unit
%
Intercept
1.45 m
True Width
1.16 m
From
380.1 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:380.1-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

Positive factors

  • Moderate copper grade for VMS deposit.

Evidence · table

“0.98”

Context: 1.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.16

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · goldGrade: 0.21Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.21
Grade Unit
g/t
Intercept
1.45 m
True Width
1.16 m
From
380.1 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:380.1-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

“0.21”

Context: 1.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.16

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · silverGrade: 39.07Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
39.07
Grade Unit
g/t
Intercept
1.45 m
True Width
1.16 m
From
380.1 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:380.1-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Arrow Zone.

Evidence · table

“39.07”

Context: 1.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.16

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · galliumGrade: 66.79Grade Unit: ppmIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
66.79
Grade Unit
ppm
Intercept
1.45 m
True Width
1.16 m
From
380.1 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:380.1-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“66.79”

Context: 1.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.16

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-004Electrolode Critical Metals · indiumGrade: 19.27Grade Unit: ppmIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-004
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
19.27
Grade Unit
ppm
Intercept
1.45 m
True Width
1.16 m
From
380.1 m
To
381.55 m
Hole Depth
411 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-004:380.1-381.55
Mining Method
unknown

Location

Location
Arrow
Easting
512531
Northing
5649226
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
133 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“19.27”

Context: 1.45

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.16

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-005Electrolode Critical Metals · zincGrade: 2.93Grade Unit: %Intercept: 3.17 mView all details
Link to this fact

Identity

Hole ID
EL-26-005
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
2.93
Grade Unit
%
Intercept
3.17 m
True Width
2.536 m
From
88.7 m
To
91.87 m
Hole Depth
120 m
Intercept Depth
88.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-005:88.7-91.87
Mining Method
unknown

Location

Location
Garnet
Easting
512828
Northing
5649207
CRS
NAD83 / Zone 15
Elevation
401 m
Azimuth
139 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate zinc intercept in the Garnet Zone, but overall potential for continuity with Arrow Zone was downgraded.

Positive factors

  • Moderate zinc grade for VMS deposit.

Negative factors

  • Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

“2.93”

Context: 3.17

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.536

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-005Electrolode Critical Metals · copperGrade: 0.05Grade Unit: %Intercept: 3.17 mView all details
Link to this fact

Identity

Hole ID
EL-26-005
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.05
Grade Unit
%
Intercept
3.17 m
True Width
2.536 m
From
88.7 m
To
91.87 m
Hole Depth
120 m
Intercept Depth
88.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-005:88.7-91.87
Mining Method
unknown

Location

Location
Garnet
Easting
512828
Northing
5649207
CRS
NAD83 / Zone 15
Elevation
401 m
Azimuth
139 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the Garnet Zone, but overall potential for continuity with Arrow Zone was downgraded.

Negative factors

  • Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

“0.05”

Context: 3.17

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.536

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-005Electrolode Critical Metals · goldGrade: 0.03Grade Unit: g/tIntercept: 3.17 mView all details
Link to this fact

Identity

Hole ID
EL-26-005
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
3.17 m
True Width
2.536 m
From
88.7 m
To
91.87 m
Hole Depth
120 m
Intercept Depth
88.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-005:88.7-91.87
Mining Method
unknown

Location

Location
Garnet
Easting
512828
Northing
5649207
CRS
NAD83 / Zone 15
Elevation
401 m
Azimuth
139 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Garnet Zone, but overall potential for continuity with Arrow Zone was downgraded.

Negative factors

  • Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

“0.03”

Context: 3.17

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.536

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-005Electrolode Critical Metals · silverGrade: 8.7Grade Unit: g/tIntercept: 3.17 mView all details
Link to this fact

Identity

Hole ID
EL-26-005
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
8.7
Grade Unit
g/t
Intercept
3.17 m
True Width
2.536 m
From
88.7 m
To
91.87 m
Hole Depth
120 m
Intercept Depth
88.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-005:88.7-91.87
Mining Method
unknown

Location

Location
Garnet
Easting
512828
Northing
5649207
CRS
NAD83 / Zone 15
Elevation
401 m
Azimuth
139 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Garnet Zone, but overall potential for continuity with Arrow Zone was downgraded.

Negative factors

  • Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

“8.70”

Context: 3.17

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.536

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-005Electrolode Critical Metals · galliumGrade: 51.51Grade Unit: ppmIntercept: 3.17 mView all details
Link to this fact

Identity

Hole ID
EL-26-005
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
51.51
Grade Unit
ppm
Intercept
3.17 m
True Width
2.536 m
From
88.7 m
To
91.87 m
Hole Depth
120 m
Intercept Depth
88.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-005:88.7-91.87
Mining Method
unknown

Location

Location
Garnet
Easting
512828
Northing
5649207
CRS
NAD83 / Zone 15
Elevation
401 m
Azimuth
139 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value, but overall potential for continuity with Arrow Zone was downgraded.

Negative factors

  • Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

“51.51”

Context: 3.17

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.536

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-005Electrolode Critical Metals · indiumGrade: 10.45Grade Unit: ppmIntercept: 3.17 mView all details
Link to this fact

Identity

Hole ID
EL-26-005
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
10.45
Grade Unit
ppm
Intercept
3.17 m
True Width
2.536 m
From
88.7 m
To
91.87 m
Hole Depth
120 m
Intercept Depth
88.7 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-005:88.7-91.87
Mining Method
unknown

Location

Location
Garnet
Easting
512828
Northing
5649207
CRS
NAD83 / Zone 15
Elevation
401 m
Azimuth
139 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value, but overall potential for continuity with Arrow Zone was downgraded.

Negative factors

  • Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

“10.45”

Context: 3.17

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 2.536

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · zincGrade: 7.81Grade Unit: %Intercept: 4.3 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
7.81
Grade Unit
%
Intercept
4.3 m
True Width
3.44 m
From
409.2 m
To
413.5 m
Hole Depth
456 m
Intercept Depth
409.2 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:409.2-413.5
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Significant zinc intercept in the hanging wall zone.

Positive factors

  • Strong zinc grade for VMS deposit.

Evidence · table

“7.81”

Context: 4.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · copperGrade: 1.9Grade Unit: %Intercept: 4.3 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.9
Grade Unit
%
Intercept
4.3 m
True Width
3.44 m
From
409.2 m
To
413.5 m
Hole Depth
456 m
Intercept Depth
409.2 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:409.2-413.5
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Strong copper intercept in the hanging wall zone.

Positive factors

  • Strong copper grade for VMS deposit.

Evidence · table

“1.90”

Context: 4.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · goldGrade: 0.72Grade Unit: g/tIntercept: 4.3 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.72
Grade Unit
g/t
Intercept
4.3 m
True Width
3.44 m
From
409.2 m
To
413.5 m
Hole Depth
456 m
Intercept Depth
409.2 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:409.2-413.5
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

“0.72”

Context: 4.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · silverGrade: 56.51Grade Unit: g/tIntercept: 4.3 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
56.51
Grade Unit
g/t
Intercept
4.3 m
True Width
3.44 m
From
409.2 m
To
413.5 m
Hole Depth
456 m
Intercept Depth
409.2 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:409.2-413.5
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

“56.51”

Context: 4.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · galliumGrade: 51.09Grade Unit: ppmIntercept: 4.3 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
51.09
Grade Unit
ppm
Intercept
4.3 m
True Width
3.44 m
From
409.2 m
To
413.5 m
Hole Depth
456 m
Intercept Depth
409.2 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:409.2-413.5
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“51.09”

Context: 4.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · indiumGrade: 9.98Grade Unit: ppmIntercept: 4.3 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
9.98
Grade Unit
ppm
Intercept
4.3 m
True Width
3.44 m
From
409.2 m
To
413.5 m
Hole Depth
456 m
Intercept Depth
409.2 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:409.2-413.5
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“9.98”

Context: 4.30

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 3.44

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · zincGrade: 16.91Grade Unit: %Intercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
16.91
Grade Unit
%
Intercept
1.91 m
True Width
1.528 m
From
410.8 m
To
412.71 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-412.71
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade zinc intercept in the hanging wall zone.

Positive factors

  • Exceptional zinc grade for VMS deposit.
  • Bonanza Intercept

Evidence · table

“16.91”

Context: 1.91

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.528

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · copperGrade: 3.59Grade Unit: %Intercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.59
Grade Unit
%
Intercept
1.91 m
True Width
1.528 m
From
410.8 m
To
412.71 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-412.71
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade copper intercept in the hanging wall zone.

Positive factors

  • Exceptional copper grade for VMS deposit.
  • Bonanza Intercept

Evidence · table

“3.59”

Context: 1.91

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.528

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · goldGrade: 1.33Grade Unit: g/tIntercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.33
Grade Unit
g/t
Intercept
1.91 m
True Width
1.528 m
From
410.8 m
To
412.71 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-412.71
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate gold intercept in the hanging wall zone.

Positive factors

  • Moderate gold grade for VMS deposit.

Evidence · table

“1.33”

Context: 1.91

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.528

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · silverGrade: 116.77Grade Unit: g/tIntercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
116.77
Grade Unit
g/t
Intercept
1.91 m
True Width
1.528 m
From
410.8 m
To
412.71 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-412.71
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate silver intercept in the hanging wall zone.

Positive factors

  • Moderate silver grade for VMS deposit.

Evidence · table

“116.77”

Context: 1.91

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.528

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · galliumGrade: 37.03Grade Unit: ppmIntercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
37.03
Grade Unit
ppm
Intercept
1.91 m
True Width
1.528 m
From
410.8 m
To
412.71 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-412.71
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“37.03”

Context: 1.91

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.528

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · indiumGrade: 17.12Grade Unit: ppmIntercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
17.12
Grade Unit
ppm
Intercept
1.91 m
True Width
1.528 m
From
410.8 m
To
412.71 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-412.71
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“17.12”

Context: 1.91

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 1.528

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · zincGrade: 38.2Grade Unit: %Intercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
38.2
Grade Unit
%
Intercept
0.42 m
True Width
0.336 m
From
410.8 m
To
411.22 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-411.22
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade zinc intercept in the hanging wall zone, representing a bonanza grade.

Positive factors

  • Exceptional zinc grade for VMS deposit.
  • Bonanza Intercept

Evidence · table

“38.20”

Context: 0.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.336

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · copperGrade: 0.14Grade Unit: %Intercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.14
Grade Unit
%
Intercept
0.42 m
True Width
0.336 m
From
410.8 m
To
411.22 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-411.22
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

“0.14”

Context: 0.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.336

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · goldGrade: 0.41Grade Unit: g/tIntercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.41
Grade Unit
g/t
Intercept
0.42 m
True Width
0.336 m
From
410.8 m
To
411.22 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-411.22
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

“0.41”

Context: 0.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.336

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · silverGrade: 88.1Grade Unit: g/tIntercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
88.1
Grade Unit
g/t
Intercept
0.42 m
True Width
0.336 m
From
410.8 m
To
411.22 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-411.22
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate silver intercept in the hanging wall zone.

Positive factors

  • Moderate silver grade for VMS deposit.

Evidence · table

“88.10”

Context: 0.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.336

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · galliumGrade: 54.7Grade Unit: ppmIntercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
54.7
Grade Unit
ppm
Intercept
0.42 m
True Width
0.336 m
From
410.8 m
To
411.22 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-411.22
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“54.70”

Context: 0.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.336

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · indiumGrade: 8.58Grade Unit: ppmIntercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
8.58
Grade Unit
ppm
Intercept
0.42 m
True Width
0.336 m
From
410.8 m
To
411.22 m
Hole Depth
456 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:410.8-411.22
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“8.58”

Context: 0.42

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.336

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · zincGrade: 1.13Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.13
Grade Unit
%
Intercept
5 m
True Width
4 m
From
416 m
To
421 m
Hole Depth
456 m
Intercept Depth
416 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:416-421
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

“1.13”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · copperGrade: 0.05Grade Unit: %Intercept: 5 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.05
Grade Unit
%
Intercept
5 m
True Width
4 m
From
416 m
To
421 m
Hole Depth
456 m
Intercept Depth
416 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:416-421
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

“0.05”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · goldGrade: 0.08Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.08
Grade Unit
g/t
Intercept
5 m
True Width
4 m
From
416 m
To
421 m
Hole Depth
456 m
Intercept Depth
416 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:416-421
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

“0.08”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · silverGrade: 14.65Grade Unit: g/tIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
14.65
Grade Unit
g/t
Intercept
5 m
True Width
4 m
From
416 m
To
421 m
Hole Depth
456 m
Intercept Depth
416 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:416-421
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

“14.65”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · galliumGrade: 39.13Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
39.13
Grade Unit
ppm
Intercept
5 m
True Width
4 m
From
416 m
To
421 m
Hole Depth
456 m
Intercept Depth
416 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:416-421
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“39.13”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · indiumGrade: 1.42Grade Unit: ppmIntercept: 5 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
indium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.42
Grade Unit
ppm
Intercept
5 m
True Width
4 m
From
416 m
To
421 m
Hole Depth
456 m
Intercept Depth
416 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:416-421
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

“1.42”

Context: 5.00

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 4

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · zincGrade: 1.38Grade Unit: %Intercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.38
Grade Unit
%
Intercept
1.15 m
True Width
0.92 m
From
425.85 m
To
427 m
Hole Depth
456 m
Intercept Depth
425.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:425.85-427
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

“1.38”

Context: 1.15

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.92

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · copperGrade: 0.54Grade Unit: %Intercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.54
Grade Unit
%
Intercept
1.15 m
True Width
0.92 m
From
425.85 m
To
427 m
Hole Depth
456 m
Intercept Depth
425.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:425.85-427
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the hanging wall zone.

Positive factors

  • Moderate copper grade for VMS deposit.

Evidence · table

“0.54”

Context: 1.15

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.92

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · goldGrade: 0.1Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.1
Grade Unit
g/t
Intercept
1.15 m
True Width
0.92 m
From
425.85 m
To
427 m
Hole Depth
456 m
Intercept Depth
425.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:425.85-427
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

“0.10”

Context: 1.15

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.92

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · silverGrade: 9.75Grade Unit: g/tIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
9.75
Grade Unit
g/t
Intercept
1.15 m
True Width
0.92 m
From
425.85 m
To
427 m
Hole Depth
456 m
Intercept Depth
425.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:425.85-427
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

“9.75”

Context: 1.15

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.92

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

EL-26-006Electrolode Critical Metals · galliumGrade: 30.5Grade Unit: ppmIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gallium
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
30.5
Grade Unit
ppm
Intercept
1.15 m
True Width
0.92 m
From
425.85 m
To
427 m
Hole Depth
456 m
Intercept Depth
425.85 m

Classification

Deposit Type
vms
Program
mixed
Sample Type
drill
Group ID
EL-26-006:425.85-427
Mining Method
unknown

Location

Location
HW
Easting
512426
Northing
5649233
CRS
NAD83 / Zone 15
Elevation
401.8 m
Azimuth
138 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Deleterious

Deleterious Flag
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

“30.50”

Context: 1.15

Tags used in scoring

True Width Disclosedpositive

Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true_width_m is 0.92

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Infill Drillingneutral

Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill_program_type is "mixed"

IncludesElectrolode Critical Metals · zincGrade: 20.14Grade Unit: %Intercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
20.14
Grade Unit
%
Intercept
1.7 m
From
342.8 m
To
344.5 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:342.8-344.5
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 20.14 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 34.2 %·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 20.14 % zinc is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“20.14”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · copperGrade: 0.89Grade Unit: %Intercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.89
Grade Unit
%
Intercept
1.7 m
From
342.8 m
To
344.5 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:342.8-344.5
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.89 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.5 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.89”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · goldGrade: 0.37Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.37
Grade Unit
g/t
Intercept
1.7 m
From
342.8 m
To
344.5 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:342.8-344.5
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.37 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.6 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.37”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · silverGrade: 112.29Grade Unit: g/tIntercept: 1.7 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
112.29
Grade Unit
g/t
Intercept
1.7 m
From
342.8 m
To
344.5 m
Intercept Depth
342.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:342.8-344.5
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 112.29 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 190.9 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“112.29”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · zincGrade: 20.44Grade Unit: %Intercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
20.44
Grade Unit
%
Intercept
1.45 m
From
380.1 m
To
381.55 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:380.1-381.55
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 20.44 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 29.6 %·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 20.44 % zinc is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“20.44”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · copperGrade: 0.98Grade Unit: %Intercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.98
Grade Unit
%
Intercept
1.45 m
From
380.1 m
To
381.55 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:380.1-381.55
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.98 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.4 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.98”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · goldGrade: 0.21Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.21
Grade Unit
g/t
Intercept
1.45 m
From
380.1 m
To
381.55 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:380.1-381.55
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below.

Negative factors

  • 0.21 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.21”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · silverGrade: 39.07Grade Unit: g/tIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
39.07
Grade Unit
g/t
Intercept
1.45 m
From
380.1 m
To
381.55 m
Intercept Depth
380.1 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:380.1-381.55
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 39.07 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 56.7 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“39.07”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · zincGrade: 16.91Grade Unit: %Intercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
16.91
Grade Unit
%
Intercept
1.91 m
From
410.8 m
To
412.71 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:410.8-412.71
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 16.91 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 32.3 %·m is weak (grade alone is strong; the better of the two is used).

Positive factors

  • 16.91 % zinc is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“16.91”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · copperGrade: 3.59Grade Unit: %Intercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.59
Grade Unit
%
Intercept
1.91 m
From
410.8 m
To
412.71 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:410.8-412.71
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 3.59 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 6.9 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 3.59 % copper is exceptional on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.59”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · goldGrade: 1.33Grade Unit: g/tIntercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.33
Grade Unit
g/t
Intercept
1.91 m
From
410.8 m
To
412.71 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:410.8-412.71
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 1.33 g/t gold is moderate against the default band [5, 2, 1, 0.3] g/t. Grade×width 2.5 g/t·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.33”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · silverGrade: 116.77Grade Unit: g/tIntercept: 1.91 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
116.77
Grade Unit
g/t
Intercept
1.91 m
From
410.8 m
To
412.71 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:410.8-412.71
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 116.77 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 223.0 g/t·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“116.77”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode Critical Metals · zincGrade: 38.2Grade Unit: %Intercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
38.2
Grade Unit
%
Intercept
0.42 m
From
410.8 m
To
411.22 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:410.8-411.22
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 38.2 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 16.0 %·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 38.2 % zinc is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“38.20”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode Critical Metals · copperGrade: 0.14Grade Unit: %Intercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.14
Grade Unit
%
Intercept
0.42 m
From
410.8 m
To
411.22 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:410.8-411.22
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.14 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.14”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode Critical Metals · goldGrade: 0.41Grade Unit: g/tIntercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.41
Grade Unit
g/t
Intercept
0.42 m
From
410.8 m
To
411.22 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:410.8-411.22
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.41 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.2 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.41”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode Critical Metals · silverGrade: 88.1Grade Unit: g/tIntercept: 0.42 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
88.1
Grade Unit
g/t
Intercept
0.42 m
From
410.8 m
To
411.22 m
Intercept Depth
410.8 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:410.8-411.22
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 88.1 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 37.0 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“88.10”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-006Electrolode Critical Metals · zincGrade: 8.4Grade Unit: %Intercept: 4 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
8.4
Grade Unit
%
Intercept
4 m
From
433 m
To
437 m
Intercept Depth
433 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-006:433-437
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 8.4 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 33.6 %·m is weak (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.40”

Context: EL-26-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-006Electrolode Critical Metals · copperGrade: 0.4Grade Unit: %Intercept: 4 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.4
Grade Unit
%
Intercept
4 m
From
433 m
To
437 m
Intercept Depth
433 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-006:433-437
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 1.6 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.40”

Context: EL-26-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-006Electrolode Critical Metals · goldGrade: 0.35Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.35
Grade Unit
g/t
Intercept
4 m
From
433 m
To
437 m
Intercept Depth
433 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-006:433-437
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.35 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 1.4 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.35”

Context: EL-26-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-006Electrolode Critical Metals · silverGrade: 21.88Grade Unit: g/tIntercept: 4 mView all details
Link to this fact

Identity

Hole ID
EL-26-006
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
21.88
Grade Unit
g/t
Intercept
4 m
From
433 m
To
437 m
Intercept Depth
433 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-006:433-437
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 21.88 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 87.5 g/t·m is below.

Negative factors

  • 21.88 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“21.88”

Context: EL-26-006

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · zincGrade: 20.05Grade Unit: %Intercept: 1.54 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
20.05
Grade Unit
%
Intercept
1.54 m
From
435 m
To
436.54 m
Intercept Depth
435 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:435-436.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 20.05 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 30.9 %·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 20.05 % zinc is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“20.05”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · copperGrade: 0.23Grade Unit: %Intercept: 1.54 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.23
Grade Unit
%
Intercept
1.54 m
From
435 m
To
436.54 m
Intercept Depth
435 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:435-436.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.4 %·m is below.

Negative factors

  • 0.23 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.23”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · goldGrade: 0.33Grade Unit: g/tIntercept: 1.54 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.33
Grade Unit
g/t
Intercept
1.54 m
From
435 m
To
436.54 m
Intercept Depth
435 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:435-436.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.33”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode Critical Metals · silverGrade: 27.54Grade Unit: g/tIntercept: 1.54 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
27.54
Grade Unit
g/t
Intercept
1.54 m
From
435 m
To
436.54 m
Intercept Depth
435 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:435-436.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 27.54 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 42.4 g/t·m is below.

Negative factors

  • 27.54 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“27.54”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode Critical Metals · zincGrade: 37.38Grade Unit: %Intercept: 0.73 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
37.38
Grade Unit
%
Intercept
0.73 m
From
435.81 m
To
436.54 m
Intercept Depth
435.81 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:435.81-436.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 37.38 % zinc is exceptional against the default band [18, 10, 5, 2] %. Grade×width 27.3 %·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 37.38 % zinc is exceptional on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“37.38”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode Critical Metals · copperGrade: 0.27Grade Unit: %Intercept: 0.73 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.27
Grade Unit
%
Intercept
0.73 m
From
435.81 m
To
436.54 m
Intercept Depth
435.81 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:435.81-436.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.27 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.27”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode Critical Metals · goldGrade: 0.45Grade Unit: g/tIntercept: 0.73 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.45
Grade Unit
g/t
Intercept
0.73 m
From
435.81 m
To
436.54 m
Intercept Depth
435.81 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:435.81-436.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.45 g/t gold is weak against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.3 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.45”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode Critical Metals · silverGrade: 40.35Grade Unit: g/tIntercept: 0.73 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
40.35
Grade Unit
g/t
Intercept
0.73 m
From
435.81 m
To
436.54 m
Intercept Depth
435.81 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:435.81-436.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 40.35 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 29.5 g/t·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“40.35”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-007Electrolode Critical Metals · zincGrade: 0.52Grade Unit: %Intercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
EL-26-007
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.52
Grade Unit
%
Intercept
1.4 m
From
100 m
To
101.4 m
Intercept Depth
100 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-007:100-101.4
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.52 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.7 %·m is below.

Negative factors

  • 0.52 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.52”

Context: EL-26-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-007Electrolode Critical Metals · copperGrade: 0.05Grade Unit: %Intercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
EL-26-007
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.05
Grade Unit
%
Intercept
1.4 m
From
100 m
To
101.4 m
Intercept Depth
100 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-007:100-101.4
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.05 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: EL-26-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-007Electrolode Critical Metals · goldGrade: 0.03Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
EL-26-007
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.03
Grade Unit
g/t
Intercept
1.4 m
From
100 m
To
101.4 m
Intercept Depth
100 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-007:100-101.4
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.03 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: EL-26-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-007Electrolode Critical Metals · silverGrade: 8.23Grade Unit: g/tIntercept: 1.4 mView all details
Link to this fact

Identity

Hole ID
EL-26-007
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
8.23
Grade Unit
g/t
Intercept
1.4 m
From
100 m
To
101.4 m
Intercept Depth
100 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-007:100-101.4
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 8.23 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 11.5 g/t·m is below.

Negative factors

  • 8.23 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.23”

Context: EL-26-007

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-008AElectrolode Critical Metals · zincGrade: 0.32Grade Unit: %Intercept: 1.04 mView all details
Link to this fact

Identity

Hole ID
EL-26-008A
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.32
Grade Unit
%
Intercept
1.04 m
From
120.5 m
To
121.54 m
Intercept Depth
120.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-008A:120.5-121.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.32 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.32”

Context: EL-26-008A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-008AElectrolode Critical Metals · copperGrade: 0.01Grade Unit: %Intercept: 1.04 mView all details
Link to this fact

Identity

Hole ID
EL-26-008A
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
%
Intercept
1.04 m
From
120.5 m
To
121.54 m
Intercept Depth
120.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-008A:120.5-121.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: EL-26-008A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-008AElectrolode Critical Metals · goldGrade: 0.01Grade Unit: g/tIntercept: 1.04 mView all details
Link to this fact

Identity

Hole ID
EL-26-008A
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
1.04 m
From
120.5 m
To
121.54 m
Intercept Depth
120.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-008A:120.5-121.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.01 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: EL-26-008A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-008AElectrolode Critical Metals · silverGrade: 0.66Grade Unit: g/tIntercept: 1.04 mView all details
Link to this fact

Identity

Hole ID
EL-26-008A
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.66
Grade Unit
g/t
Intercept
1.04 m
From
120.5 m
To
121.54 m
Intercept Depth
120.5 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-008A:120.5-121.54
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.66 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 0.7 g/t·m is below.

Negative factors

  • 0.66 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.66”

Context: EL-26-008A

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-009Electrolode Critical Metals · zincGrade: 0.1Grade Unit: %Intercept: 0.58 mView all details
Link to this fact

Identity

Hole ID
EL-26-009
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.1
Grade Unit
%
Intercept
0.58 m
From
132.3 m
To
132.88 m
Intercept Depth
132.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-009:132.3-132.88
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.1 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.10”

Context: EL-26-009

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-009Electrolode Critical Metals · copperGrade: 0.01Grade Unit: %Intercept: 0.58 mView all details
Link to this fact

Identity

Hole ID
EL-26-009
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
%
Intercept
0.58 m
From
132.3 m
To
132.88 m
Intercept Depth
132.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-009:132.3-132.88
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0.01 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: EL-26-009

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-009Electrolode Critical Metals · goldGrade: 0.01Grade Unit: g/tIntercept: 0.58 mView all details
Link to this fact

Identity

Hole ID
EL-26-009
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
0.58 m
From
132.3 m
To
132.88 m
Intercept Depth
132.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-009:132.3-132.88
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.0 g/t·m is below.

Negative factors

  • 0.01 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: EL-26-009

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-009Electrolode Critical Metals · silverGrade: 2.15Grade Unit: g/tIntercept: 0.58 mView all details
Link to this fact

Identity

Hole ID
EL-26-009
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
2.15
Grade Unit
g/t
Intercept
0.58 m
From
132.3 m
To
132.88 m
Intercept Depth
132.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-009:132.3-132.88
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 2.15 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 1.2 g/t·m is below.

Negative factors

  • 2.15 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.15”

Context: EL-26-009

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-010Electrolode Critical Metals · zincGrade: 0.28Grade Unit: %Intercept: 6.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-010
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.28
Grade Unit
%
Intercept
6.8 m
From
87 m
To
93.8 m
Intercept Depth
87 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-010:87-93.8
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 1.9 %·m is below.

Negative factors

  • 0.28 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.28”

Context: EL-26-010

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-010Electrolode Critical Metals · copperGrade: 0.03Grade Unit: %Intercept: 6.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-010
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.03
Grade Unit
%
Intercept
6.8 m
From
87 m
To
93.8 m
Intercept Depth
87 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-010:87-93.8
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % copper is below against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 0.2 %·m is below.

Negative factors

  • 0.03 % copper is below the weak threshold (0.4 %) on the vms deposit band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.03”

Context: EL-26-010

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-010Electrolode Critical Metals · goldGrade: 0.01Grade Unit: g/tIntercept: 6.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-010
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
g/t
Intercept
6.8 m
From
87 m
To
93.8 m
Intercept Depth
87 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-010:87-93.8
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band [5, 2, 1, 0.3] g/t. Grade×width 0.1 g/t·m is below.

Negative factors

  • 0.01 g/t gold is below the weak threshold (0.3 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: EL-26-010

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-010Electrolode Critical Metals · silverGrade: 1.92Grade Unit: g/tIntercept: 6.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-010
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.92
Grade Unit
g/t
Intercept
6.8 m
From
87 m
To
93.8 m
Intercept Depth
87 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-010:87-93.8
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 1.92 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 13.1 g/t·m is below.

Negative factors

  • 1.92 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.92”

Context: EL-26-010

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-001Electrolode Critical Metals · zincGrade: 38Grade Unit: ppmIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-001
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
38
Grade Unit
ppm
Intercept
1.2 m
From
339.3 m
To
340.5 m
Intercept Depth
339.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-001:339.3-340.5
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 38 ppm zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit ppm does not match the zinc rubric unit %; not scored.

Evidence · table

“38”

Context: EL-26-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-001Electrolode Critical Metals · copperGrade: 3270Grade Unit: ppmIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-001
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3270
Grade Unit
ppm
Intercept
1.2 m
From
339.3 m
To
340.5 m
Intercept Depth
339.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-001:339.3-340.5
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 3270 ppm copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit ppm does not match the copper rubric unit %; not scored.

Evidence · table

“3270”

Context: EL-26-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-001Electrolode Critical Metals · goldGrade: 0.68Grade Unit: ppmIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-001
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.68
Grade Unit
ppm
Intercept
1.2 m
From
339.3 m
To
340.5 m
Intercept Depth
339.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-001:339.3-340.5
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 0.68 ppm gold, reported in a unit the rubric does not cover (g/t).

Negative factors

  • Grade unit ppm does not match the gold rubric unit g/t; not scored.

Evidence · table

“0.68”

Context: EL-26-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-001Electrolode Critical Metals · silverGrade: 5.35Grade Unit: ppmIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-001
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
5.35
Grade Unit
ppm
Intercept
1.2 m
From
339.3 m
To
340.5 m
Intercept Depth
339.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-001:339.3-340.5
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 5.35 ppm silver, reported in a unit the rubric does not cover (g/t).

Negative factors

  • Grade unit ppm does not match the silver rubric unit g/t; not scored.

Evidence · table

“5.35”

Context: EL-26-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-001Electrolode Critical Metals · zincGrade: 1530Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
EL-26-001
Project
Electrolode Critical Metals
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1530
Grade Unit
ppm
Intercept
3 m
From
486 m
To
489 m
Intercept Depth
486 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-001:486-489
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 1530 ppm zinc, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit ppm does not match the zinc rubric unit %; not scored.

Evidence · table

“1530”

Context: EL-26-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-001Electrolode Critical Metals · copperGrade: 59Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
EL-26-001
Project
Electrolode Critical Metals
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
59
Grade Unit
ppm
Intercept
3 m
From
486 m
To
489 m
Intercept Depth
486 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-001:486-489
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 59 ppm copper, reported in a unit the rubric does not cover (%).

Negative factors

  • Grade unit ppm does not match the copper rubric unit %; not scored.

Evidence · table

“59”

Context: EL-26-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-001Electrolode Critical Metals · goldGrade: 0Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
EL-26-001
Project
Electrolode Critical Metals
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0
Grade Unit
ppm
Intercept
3 m
From
486 m
To
489 m
Intercept Depth
486 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-001:486-489
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 0 ppm gold, reported in a unit the rubric does not cover (g/t).

Negative factors

  • Grade unit ppm does not match the gold rubric unit g/t; not scored.

Evidence · table

“0.00”

Context: EL-26-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-001Electrolode Critical Metals · silverGrade: 0.21Grade Unit: ppmIntercept: 3 mView all details
Link to this fact

Identity

Hole ID
EL-26-001
Project
Electrolode Critical Metals
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.21
Grade Unit
ppm
Intercept
3 m
From
486 m
To
489 m
Intercept Depth
486 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
EL-26-001:486-489
Mining Method
unknown

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 0.21 ppm silver, reported in a unit the rubric does not cover (g/t).

Negative factors

  • Grade unit ppm does not match the silver rubric unit g/t; not scored.

Evidence · table

“0.21”

Context: EL-26-001

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.