# Total Metals Reports Positive Results at its Electrolode Critical Metals Project - Including High-Grade intercepts up to 38.20% Zinc over 0.42m and 3.59% Copper over 1.91m

Canonical Atlas analysis: https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028

Original source: https://money.tmx.com/en/quote/TT/news/7565568727135462/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project

Publisher: tmx

Original announcement: 2026-06-22T08:00:00.000Z

Analysis by Minestarters Atlas

Atlas analysis published: Unknown date

Atlas analysis updated: Unknown date

- Company: Total Metals Corp.

- Ticker: TT

- Exchange: TSX

- Region: Northwestern Ontario

- Primary commodity: Zinc

- Secondary commodities: Copper, Gold, Silver, Gallium, Indium

- Document categories: Drill results, Resource update

- Extracted: 2026-09-17 02:46:32 UTC

Narrative sentiment: 0.80 · Bullish

## Minestarters Atlas summary

Total Metals Corp. announced positive drill results from its winter 2026 program at the Electrolode Critical Metals Project in Northwestern Ontario. Several intercepts in the Arrow Zone and its hanging wall returned high-grade zinc and copper, with subintervals reaching up to 38.20% Zinc over 0.42m and 3.59% Copper over 1.91m, significantly exceeding the project's current inferred resource grades. The company also noted elevated gallium and indium values, indicating potential for additional critical metals, and confirmed robust QA/QC procedures.

Reasoning: The announcement reports new high-grade drill results for zinc and copper from the Electrolode project, with several intercepts significantly exceeding the existing inferred resource grades. The presence of elevated gallium and indium adds potential value. Strong QA/QC procedures support the results. While some targets were downgraded, the overall results are highly positive for the project's potential.

- Positive factor: High-grade zinc and copper intercepts significantly exceed the existing resource grade.

- Positive factor: Discovery of a highly mineralized zone in the hanging wall with significant copper values.

- Positive factor: Elevated gallium and indium values indicate potential for additional critical metals.

- Positive factor: Comprehensive QA/QC procedures including certified lab, standards, blanks, and third-party verification.

- Negative factor: True thickness is estimated, not precisely measured for all intercepts.

- Negative factor: Garnet Zone drilling downgraded potential for continuity with Arrow Zone.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 141

## Classification and evidence

No classification tags are available.

## Extracted facts

Stored fact records: 141. Some facts used in scoring do not have a stored record.

## Drill Results (141)

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-0)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.91
- Grade Unit: %
- Intercept: 2.55 m
- True Width: 2.04 m
- From: 335.25 m
- To: 337.8 m
- Hole Depth: 405 m
- Intercept Depth: 335.25 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:335.25-337.8
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

> 0.91

Context: 2.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.04

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-1)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.02
- Grade Unit: %
- Intercept: 2.55 m
- True Width: 2.04 m
- From: 335.25 m
- To: 337.8 m
- Hole Depth: 405 m
- Intercept Depth: 335.25 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:335.25-337.8
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

> 0.02

Context: 2.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.04

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-2)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.16
- Grade Unit: g/t
- Intercept: 2.55 m
- True Width: 2.04 m
- From: 335.25 m
- To: 337.8 m
- Hole Depth: 405 m
- Intercept Depth: 335.25 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:335.25-337.8
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

> 0.16

Context: 2.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.04

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-3)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 24.93
- Grade Unit: g/t
- Intercept: 2.55 m
- True Width: 2.04 m
- From: 335.25 m
- To: 337.8 m
- Hole Depth: 405 m
- Intercept Depth: 335.25 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:335.25-337.8
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

> 24.93

Context: 2.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.04

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-4)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 49.14
- Grade Unit: ppm
- Intercept: 2.55 m
- True Width: 2.04 m
- From: 335.25 m
- To: 337.8 m
- Hole Depth: 405 m
- Intercept Depth: 335.25 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:335.25-337.8
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 49.14

Context: 2.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.04

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-5)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.34
- Grade Unit: ppm
- Intercept: 2.55 m
- True Width: 2.04 m
- From: 335.25 m
- To: 337.8 m
- Hole Depth: 405 m
- Intercept Depth: 335.25 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:335.25-337.8
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 0.34

Context: 2.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.04

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-6)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.95
- Grade Unit: %
- Intercept: 1.9 m
- True Width: 1.52 m
- From: 369 m
- To: 370.9 m
- Hole Depth: 405 m
- Intercept Depth: 369 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:369-370.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

> 0.95

Context: 1.90

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.52

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-7)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.09
- Grade Unit: %
- Intercept: 1.9 m
- True Width: 1.52 m
- From: 369 m
- To: 370.9 m
- Hole Depth: 405 m
- Intercept Depth: 369 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:369-370.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

> 0.09

Context: 1.90

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.52

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-8)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 1.9 m
- True Width: 1.52 m
- From: 369 m
- To: 370.9 m
- Hole Depth: 405 m
- Intercept Depth: 369 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:369-370.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

> 0.03

Context: 1.90

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.52

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-9)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1.21
- Grade Unit: g/t
- Intercept: 1.9 m
- True Width: 1.52 m
- From: 369 m
- To: 370.9 m
- Hole Depth: 405 m
- Intercept Depth: 369 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:369-370.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

> 1.21

Context: 1.90

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.52

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-10)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 80.06
- Grade Unit: ppm
- Intercept: 1.9 m
- True Width: 1.52 m
- From: 369 m
- To: 370.9 m
- Hole Depth: 405 m
- Intercept Depth: 369 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:369-370.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 80.06

Context: 1.90

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.52

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-11)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 4.99
- Grade Unit: ppm
- Intercept: 1.9 m
- True Width: 1.52 m
- From: 369 m
- To: 370.9 m
- Hole Depth: 405 m
- Intercept Depth: 369 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:369-370.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 4.99

Context: 1.90

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.52

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-12)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 5.1
- Grade Unit: %
- Intercept: 4.55 m
- True Width: 3.64 m
- From: 374.85 m
- To: 379.4 m
- Hole Depth: 405 m
- Intercept Depth: 374.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:374.85-379.4
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Significant zinc intercept in the Arrow Zone, exceeding the average resource grade.

- Positive factor: Strong zinc grade for VMS deposit.

Evidence · table

> 5.10

Context: 4.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-13)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.5
- Grade Unit: %
- Intercept: 4.55 m
- True Width: 3.64 m
- From: 374.85 m
- To: 379.4 m
- Hole Depth: 405 m
- Intercept Depth: 374.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:374.85-379.4
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

- Positive factor: Moderate copper grade for VMS deposit.

Evidence · table

> 0.50

Context: 4.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-14)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.41
- Grade Unit: g/t
- Intercept: 4.55 m
- True Width: 3.64 m
- From: 374.85 m
- To: 379.4 m
- Hole Depth: 405 m
- Intercept Depth: 374.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:374.85-379.4
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

> 0.41

Context: 4.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-15)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 18.21
- Grade Unit: g/t
- Intercept: 4.55 m
- True Width: 3.64 m
- From: 374.85 m
- To: 379.4 m
- Hole Depth: 405 m
- Intercept Depth: 374.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:374.85-379.4
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Arrow Zone.

Evidence · table

> 18.21

Context: 4.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-16)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 71.11
- Grade Unit: ppm
- Intercept: 4.55 m
- True Width: 3.64 m
- From: 374.85 m
- To: 379.4 m
- Hole Depth: 405 m
- Intercept Depth: 374.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:374.85-379.4
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 71.11

Context: 4.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-002

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-17)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-002
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 40.15
- Grade Unit: ppm
- Intercept: 4.55 m
- True Width: 3.64 m
- From: 374.85 m
- To: 379.4 m
- Hole Depth: 405 m
- Intercept Depth: 374.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-002:374.85-379.4
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512588
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.5 m
- Azimuth: 135 °
- Dip: -70 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 40.15

Context: 4.55

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.64

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-18)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1.13
- Grade Unit: %
- Intercept: 0.86 m
- True Width: 0.688 m
- From: 330.14 m
- To: 331 m
- Hole Depth: 387 m
- Intercept Depth: 330.14 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:330.14-331
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

> 1.13

Context: 0.86

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.688

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-19)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.19
- Grade Unit: %
- Intercept: 0.86 m
- True Width: 0.688 m
- From: 330.14 m
- To: 331 m
- Hole Depth: 387 m
- Intercept Depth: 330.14 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:330.14-331
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

> 0.19

Context: 0.86

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.688

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-20)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 0.86 m
- True Width: 0.688 m
- From: 330.14 m
- To: 331 m
- Hole Depth: 387 m
- Intercept Depth: 330.14 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:330.14-331
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

> 0.10

Context: 0.86

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.688

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-21)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 5.03
- Grade Unit: g/t
- Intercept: 0.86 m
- True Width: 0.688 m
- From: 330.14 m
- To: 331 m
- Hole Depth: 387 m
- Intercept Depth: 330.14 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:330.14-331
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

> 5.03

Context: 0.86

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.688

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-22)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 63.3
- Grade Unit: ppm
- Intercept: 0.86 m
- True Width: 0.688 m
- From: 330.14 m
- To: 331 m
- Hole Depth: 387 m
- Intercept Depth: 330.14 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:330.14-331
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 63.30

Context: 0.86

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.688

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-23)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 16.2
- Grade Unit: ppm
- Intercept: 0.86 m
- True Width: 0.688 m
- From: 330.14 m
- To: 331 m
- Hole Depth: 387 m
- Intercept Depth: 330.14 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:330.14-331
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 16.20

Context: 0.86

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.688

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-24)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 7
- Grade Unit: %
- Intercept: 7.18 m
- True Width: 5.744 m
- From: 341 m
- To: 348.18 m
- Hole Depth: 387 m
- Intercept Depth: 341 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:341-348.18
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Significant zinc intercept in the Arrow Zone, exceeding the average resource grade over a good length.

- Positive factor: Strong zinc grade for VMS deposit.

- Positive factor: Good intercept length.

Evidence · table

> 7.00

Context: 7.18

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.744

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-25)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.47
- Grade Unit: %
- Intercept: 7.18 m
- True Width: 5.744 m
- From: 341 m
- To: 348.18 m
- Hole Depth: 387 m
- Intercept Depth: 341 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:341-348.18
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

- Positive factor: Moderate copper grade for VMS deposit.

Evidence · table

> 0.47

Context: 7.18

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.744

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-26)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.25
- Grade Unit: g/t
- Intercept: 7.18 m
- True Width: 5.744 m
- From: 341 m
- To: 348.18 m
- Hole Depth: 387 m
- Intercept Depth: 341 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:341-348.18
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

> 0.25

Context: 7.18

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.744

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-27)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 32.73
- Grade Unit: g/t
- Intercept: 7.18 m
- True Width: 5.744 m
- From: 341 m
- To: 348.18 m
- Hole Depth: 387 m
- Intercept Depth: 341 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:341-348.18
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Arrow Zone.

Evidence · table

> 32.73

Context: 7.18

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.744

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-28)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 83.29
- Grade Unit: ppm
- Intercept: 7.18 m
- True Width: 5.744 m
- From: 341 m
- To: 348.18 m
- Hole Depth: 387 m
- Intercept Depth: 341 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:341-348.18
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 83.29

Context: 7.18

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.744

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-29)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 23.78
- Grade Unit: ppm
- Intercept: 7.18 m
- True Width: 5.744 m
- From: 341 m
- To: 348.18 m
- Hole Depth: 387 m
- Intercept Depth: 341 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:341-348.18
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 23.78

Context: 7.18

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 5.744

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-30)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 20.14
- Grade Unit: %
- Intercept: 1.7 m
- True Width: 1.36 m
- From: 342.8 m
- To: 344.5 m
- Hole Depth: 387 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:342.8-344.5
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade zinc intercept in the Arrow Zone, significantly above the average resource grade.

- Positive factor: Exceptional zinc grade for VMS deposit.

- Positive factor: Bonanza Intercept

Evidence · table

> 20.14

Context: 1.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.36

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-31)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.89
- Grade Unit: %
- Intercept: 1.7 m
- True Width: 1.36 m
- From: 342.8 m
- To: 344.5 m
- Hole Depth: 387 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:342.8-344.5
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

- Positive factor: Moderate copper grade for VMS deposit.

Evidence · table

> 0.89

Context: 1.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.36

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-32)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.37
- Grade Unit: g/t
- Intercept: 1.7 m
- True Width: 1.36 m
- From: 342.8 m
- To: 344.5 m
- Hole Depth: 387 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:342.8-344.5
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

> 0.37

Context: 1.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.36

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-33)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 112.29
- Grade Unit: g/t
- Intercept: 1.7 m
- True Width: 1.36 m
- From: 342.8 m
- To: 344.5 m
- Hole Depth: 387 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:342.8-344.5
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate silver intercept in the Arrow Zone.

- Positive factor: Moderate silver grade for VMS deposit.

Evidence · table

> 112.29

Context: 1.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.36

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-34)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 105.92
- Grade Unit: ppm
- Intercept: 1.7 m
- True Width: 1.36 m
- From: 342.8 m
- To: 344.5 m
- Hole Depth: 387 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:342.8-344.5
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 105.92

Context: 1.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.36

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-003A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-35)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-003A
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 38.58
- Grade Unit: ppm
- Intercept: 1.7 m
- True Width: 1.36 m
- From: 342.8 m
- To: 344.5 m
- Hole Depth: 387 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-003A:342.8-344.5
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512589
- Northing: 5649252
- CRS: NAD83 / Zone 15
- Elevation: 402.6 m
- Azimuth: 134 °
- Dip: -64 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 38.58

Context: 1.70

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.36

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-36)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.99
- Grade Unit: %
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 348.4 m
- To: 349.9 m
- Hole Depth: 411 m
- Intercept Depth: 348.4 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:348.4-349.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

> 0.99

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-37)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.26
- Grade Unit: %
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 348.4 m
- To: 349.9 m
- Hole Depth: 411 m
- Intercept Depth: 348.4 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:348.4-349.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

> 0.26

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-38)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.06
- Grade Unit: g/t
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 348.4 m
- To: 349.9 m
- Hole Depth: 411 m
- Intercept Depth: 348.4 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:348.4-349.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

> 0.06

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-39)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 2.41
- Grade Unit: g/t
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 348.4 m
- To: 349.9 m
- Hole Depth: 411 m
- Intercept Depth: 348.4 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:348.4-349.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

> 2.41

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-40)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 38.53
- Grade Unit: ppm
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 348.4 m
- To: 349.9 m
- Hole Depth: 411 m
- Intercept Depth: 348.4 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:348.4-349.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 38.53

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-41)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.1
- Grade Unit: ppm
- Intercept: 1.5 m
- True Width: 1.2 m
- From: 348.4 m
- To: 349.9 m
- Hole Depth: 411 m
- Intercept Depth: 348.4 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:348.4-349.9
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 0.10

Context: 1.50

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.2

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-42)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 3.85
- Grade Unit: %
- Intercept: 9.75 m
- True Width: 7.8 m
- From: 371.8 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 371.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:371.8-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate zinc intercept in the Arrow Zone over a good length.

- Positive factor: Moderate zinc grade for VMS deposit.

- Positive factor: Good intercept length.

Evidence · table

> 3.85

Context: 9.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 7.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-43)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.5
- Grade Unit: %
- Intercept: 9.75 m
- True Width: 7.8 m
- From: 371.8 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 371.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:371.8-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

- Positive factor: Moderate copper grade for VMS deposit.

Evidence · table

> 0.50

Context: 9.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 7.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-44)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.19
- Grade Unit: g/t
- Intercept: 9.75 m
- True Width: 7.8 m
- From: 371.8 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 371.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:371.8-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

> 0.19

Context: 9.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 7.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-45)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 18.59
- Grade Unit: g/t
- Intercept: 9.75 m
- True Width: 7.8 m
- From: 371.8 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 371.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:371.8-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Arrow Zone.

Evidence · table

> 18.59

Context: 9.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 7.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-46)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 40.9
- Grade Unit: ppm
- Intercept: 9.75 m
- True Width: 7.8 m
- From: 371.8 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 371.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:371.8-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 40.90

Context: 9.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 7.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-47)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 11.45
- Grade Unit: ppm
- Intercept: 9.75 m
- True Width: 7.8 m
- From: 371.8 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 371.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:371.8-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 11.45

Context: 9.75

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 7.8

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-48)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 20.44
- Grade Unit: %
- Intercept: 1.45 m
- True Width: 1.16 m
- From: 380.1 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:380.1-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade zinc intercept in the Arrow Zone, significantly above the average resource grade.

- Positive factor: Exceptional zinc grade for VMS deposit.

- Positive factor: Bonanza Intercept

Evidence · table

> 20.44

Context: 1.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-49)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.98
- Grade Unit: %
- Intercept: 1.45 m
- True Width: 1.16 m
- From: 380.1 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:380.1-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the Arrow Zone.

- Positive factor: Moderate copper grade for VMS deposit.

Evidence · table

> 0.98

Context: 1.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-50)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.21
- Grade Unit: g/t
- Intercept: 1.45 m
- True Width: 1.16 m
- From: 380.1 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:380.1-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Arrow Zone.

Evidence · table

> 0.21

Context: 1.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-51)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 39.07
- Grade Unit: g/t
- Intercept: 1.45 m
- True Width: 1.16 m
- From: 380.1 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:380.1-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Arrow Zone.

Evidence · table

> 39.07

Context: 1.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-52)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 66.79
- Grade Unit: ppm
- Intercept: 1.45 m
- True Width: 1.16 m
- From: 380.1 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:380.1-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 66.79

Context: 1.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-004

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-53)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-004
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 19.27
- Grade Unit: ppm
- Intercept: 1.45 m
- True Width: 1.16 m
- From: 380.1 m
- To: 381.55 m
- Hole Depth: 411 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-004:380.1-381.55
- Mining Method: unknown

#### Location

- Location: Arrow
- Easting: 512531
- Northing: 5649226
- CRS: NAD83 / Zone 15
- Elevation: 402.1 m
- Azimuth: 133 °
- Dip: -66 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 19.27

Context: 1.45

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.16

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-54)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-005
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 2.93
- Grade Unit: %
- Intercept: 3.17 m
- True Width: 2.536 m
- From: 88.7 m
- To: 91.87 m
- Hole Depth: 120 m
- Intercept Depth: 88.7 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-005:88.7-91.87
- Mining Method: unknown

#### Location

- Location: Garnet
- Easting: 512828
- Northing: 5649207
- CRS: NAD83 / Zone 15
- Elevation: 401 m
- Azimuth: 139 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate zinc intercept in the Garnet Zone, but overall potential for continuity with Arrow Zone was downgraded.

- Positive factor: Moderate zinc grade for VMS deposit.

- Negative factor: Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

> 2.93

Context: 3.17

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.536

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-55)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-005
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 3.17 m
- True Width: 2.536 m
- From: 88.7 m
- To: 91.87 m
- Hole Depth: 120 m
- Intercept Depth: 88.7 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-005:88.7-91.87
- Mining Method: unknown

#### Location

- Location: Garnet
- Easting: 512828
- Northing: 5649207
- CRS: NAD83 / Zone 15
- Elevation: 401 m
- Azimuth: 139 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the Garnet Zone, but overall potential for continuity with Arrow Zone was downgraded.

- Negative factor: Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

> 0.05

Context: 3.17

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.536

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-56)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-005
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 3.17 m
- True Width: 2.536 m
- From: 88.7 m
- To: 91.87 m
- Hole Depth: 120 m
- Intercept Depth: 88.7 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-005:88.7-91.87
- Mining Method: unknown

#### Location

- Location: Garnet
- Easting: 512828
- Northing: 5649207
- CRS: NAD83 / Zone 15
- Elevation: 401 m
- Azimuth: 139 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the Garnet Zone, but overall potential for continuity with Arrow Zone was downgraded.

- Negative factor: Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

> 0.03

Context: 3.17

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.536

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-57)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-005
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 8.7
- Grade Unit: g/t
- Intercept: 3.17 m
- True Width: 2.536 m
- From: 88.7 m
- To: 91.87 m
- Hole Depth: 120 m
- Intercept Depth: 88.7 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-005:88.7-91.87
- Mining Method: unknown

#### Location

- Location: Garnet
- Easting: 512828
- Northing: 5649207
- CRS: NAD83 / Zone 15
- Elevation: 401 m
- Azimuth: 139 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the Garnet Zone, but overall potential for continuity with Arrow Zone was downgraded.

- Negative factor: Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

> 8.70

Context: 3.17

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.536

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-58)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-005
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 51.51
- Grade Unit: ppm
- Intercept: 3.17 m
- True Width: 2.536 m
- From: 88.7 m
- To: 91.87 m
- Hole Depth: 120 m
- Intercept Depth: 88.7 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-005:88.7-91.87
- Mining Method: unknown

#### Location

- Location: Garnet
- Easting: 512828
- Northing: 5649207
- CRS: NAD83 / Zone 15
- Elevation: 401 m
- Azimuth: 139 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value, but overall potential for continuity with Arrow Zone was downgraded.

- Negative factor: Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

> 51.51

Context: 3.17

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.536

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-005

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-59)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-005
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 10.45
- Grade Unit: ppm
- Intercept: 3.17 m
- True Width: 2.536 m
- From: 88.7 m
- To: 91.87 m
- Hole Depth: 120 m
- Intercept Depth: 88.7 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-005:88.7-91.87
- Mining Method: unknown

#### Location

- Location: Garnet
- Easting: 512828
- Northing: 5649207
- CRS: NAD83 / Zone 15
- Elevation: 401 m
- Azimuth: 139 °
- Dip: -50 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value, but overall potential for continuity with Arrow Zone was downgraded.

- Negative factor: Garnet Zone downgraded potential for continuity with Arrow Zone.

Evidence · table

> 10.45

Context: 3.17

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 2.536

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-60)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 7.81
- Grade Unit: %
- Intercept: 4.3 m
- True Width: 3.44 m
- From: 409.2 m
- To: 413.5 m
- Hole Depth: 456 m
- Intercept Depth: 409.2 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:409.2-413.5
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Significant zinc intercept in the hanging wall zone.

- Positive factor: Strong zinc grade for VMS deposit.

Evidence · table

> 7.81

Context: 4.30

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.44

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-61)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1.9
- Grade Unit: %
- Intercept: 4.3 m
- True Width: 3.44 m
- From: 409.2 m
- To: 413.5 m
- Hole Depth: 456 m
- Intercept Depth: 409.2 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:409.2-413.5
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Strong copper intercept in the hanging wall zone.

- Positive factor: Strong copper grade for VMS deposit.

Evidence · table

> 1.90

Context: 4.30

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.44

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-62)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.72
- Grade Unit: g/t
- Intercept: 4.3 m
- True Width: 3.44 m
- From: 409.2 m
- To: 413.5 m
- Hole Depth: 456 m
- Intercept Depth: 409.2 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:409.2-413.5
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

> 0.72

Context: 4.30

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.44

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-63)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 56.51
- Grade Unit: g/t
- Intercept: 4.3 m
- True Width: 3.44 m
- From: 409.2 m
- To: 413.5 m
- Hole Depth: 456 m
- Intercept Depth: 409.2 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:409.2-413.5
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

> 56.51

Context: 4.30

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.44

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-64)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 51.09
- Grade Unit: ppm
- Intercept: 4.3 m
- True Width: 3.44 m
- From: 409.2 m
- To: 413.5 m
- Hole Depth: 456 m
- Intercept Depth: 409.2 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:409.2-413.5
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 51.09

Context: 4.30

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.44

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-65)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 9.98
- Grade Unit: ppm
- Intercept: 4.3 m
- True Width: 3.44 m
- From: 409.2 m
- To: 413.5 m
- Hole Depth: 456 m
- Intercept Depth: 409.2 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:409.2-413.5
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 9.98

Context: 4.30

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 3.44

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-66)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 16.91
- Grade Unit: %
- Intercept: 1.91 m
- True Width: 1.528 m
- From: 410.8 m
- To: 412.71 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-412.71
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade zinc intercept in the hanging wall zone.

- Positive factor: Exceptional zinc grade for VMS deposit.

- Positive factor: Bonanza Intercept

Evidence · table

> 16.91

Context: 1.91

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.528

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-67)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 3.59
- Grade Unit: %
- Intercept: 1.91 m
- True Width: 1.528 m
- From: 410.8 m
- To: 412.71 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-412.71
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade copper intercept in the hanging wall zone.

- Positive factor: Exceptional copper grade for VMS deposit.

- Positive factor: Bonanza Intercept

Evidence · table

> 3.59

Context: 1.91

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.528

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-68)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1.33
- Grade Unit: g/t
- Intercept: 1.91 m
- True Width: 1.528 m
- From: 410.8 m
- To: 412.71 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-412.71
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate gold intercept in the hanging wall zone.

- Positive factor: Moderate gold grade for VMS deposit.

Evidence · table

> 1.33

Context: 1.91

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.528

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-69)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 116.77
- Grade Unit: g/t
- Intercept: 1.91 m
- True Width: 1.528 m
- From: 410.8 m
- To: 412.71 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-412.71
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate silver intercept in the hanging wall zone.

- Positive factor: Moderate silver grade for VMS deposit.

Evidence · table

> 116.77

Context: 1.91

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.528

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-70)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 37.03
- Grade Unit: ppm
- Intercept: 1.91 m
- True Width: 1.528 m
- From: 410.8 m
- To: 412.71 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-412.71
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 37.03

Context: 1.91

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.528

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-71)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 17.12
- Grade Unit: ppm
- Intercept: 1.91 m
- True Width: 1.528 m
- From: 410.8 m
- To: 412.71 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-412.71
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 17.12

Context: 1.91

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 1.528

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-72)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 38.2
- Grade Unit: %
- Intercept: 0.42 m
- True Width: 0.336 m
- From: 410.8 m
- To: 411.22 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-411.22
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Exceptional high-grade zinc intercept in the hanging wall zone, representing a bonanza grade.

- Positive factor: Exceptional zinc grade for VMS deposit.

- Positive factor: Bonanza Intercept

Evidence · table

> 38.20

Context: 0.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.336

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-73)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 0.42 m
- True Width: 0.336 m
- From: 410.8 m
- To: 411.22 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-411.22
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

> 0.14

Context: 0.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.336

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-74)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.41
- Grade Unit: g/t
- Intercept: 0.42 m
- True Width: 0.336 m
- From: 410.8 m
- To: 411.22 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-411.22
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

> 0.41

Context: 0.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.336

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-75)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 88.1
- Grade Unit: g/t
- Intercept: 0.42 m
- True Width: 0.336 m
- From: 410.8 m
- To: 411.22 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-411.22
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate silver intercept in the hanging wall zone.

- Positive factor: Moderate silver grade for VMS deposit.

Evidence · table

> 88.10

Context: 0.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.336

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-76)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 54.7
- Grade Unit: ppm
- Intercept: 0.42 m
- True Width: 0.336 m
- From: 410.8 m
- To: 411.22 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-411.22
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 54.70

Context: 0.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.336

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-77)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 8.58
- Grade Unit: ppm
- Intercept: 0.42 m
- True Width: 0.336 m
- From: 410.8 m
- To: 411.22 m
- Hole Depth: 456 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:410.8-411.22
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 8.58

Context: 0.42

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.336

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-78)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1.13
- Grade Unit: %
- Intercept: 5 m
- True Width: 4 m
- From: 416 m
- To: 421 m
- Hole Depth: 456 m
- Intercept Depth: 416 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:416-421
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

> 1.13

Context: 5.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-79)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 5 m
- True Width: 4 m
- From: 416 m
- To: 421 m
- Hole Depth: 456 m
- Intercept Depth: 416 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:416-421
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade copper intercept in the hanging wall zone.

Evidence · table

> 0.05

Context: 5.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-80)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.08
- Grade Unit: g/t
- Intercept: 5 m
- True Width: 4 m
- From: 416 m
- To: 421 m
- Hole Depth: 456 m
- Intercept Depth: 416 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:416-421
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

> 0.08

Context: 5.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-81)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 14.65
- Grade Unit: g/t
- Intercept: 5 m
- True Width: 4 m
- From: 416 m
- To: 421 m
- Hole Depth: 456 m
- Intercept Depth: 416 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:416-421
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

> 14.65

Context: 5.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-82)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 39.13
- Grade Unit: ppm
- Intercept: 5 m
- True Width: 4 m
- From: 416 m
- To: 421 m
- Hole Depth: 456 m
- Intercept Depth: 416 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:416-421
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 39.13

Context: 5.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-83)

Electrolode Critical Metals · indium

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: indium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1.42
- Grade Unit: ppm
- Intercept: 5 m
- True Width: 4 m
- From: 416 m
- To: 421 m
- Hole Depth: 456 m
- Intercept Depth: 416 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:416-421
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated indium values, indicating potential for additional value.

Evidence · table

> 1.42

Context: 5.00

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 4

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-84)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1.38
- Grade Unit: %
- Intercept: 1.15 m
- True Width: 0.92 m
- From: 425.85 m
- To: 427 m
- Hole Depth: 456 m
- Intercept Depth: 425.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:425.85-427
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade zinc intercept in the hanging wall zone.

Evidence · table

> 1.38

Context: 1.15

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-85)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.54
- Grade Unit: %
- Intercept: 1.15 m
- True Width: 0.92 m
- From: 425.85 m
- To: 427 m
- Hole Depth: 456 m
- Intercept Depth: 425.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:425.85-427
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Moderate copper intercept in the hanging wall zone.

- Positive factor: Moderate copper grade for VMS deposit.

Evidence · table

> 0.54

Context: 1.15

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-86)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.1
- Grade Unit: g/t
- Intercept: 1.15 m
- True Width: 0.92 m
- From: 425.85 m
- To: 427 m
- Hole Depth: 456 m
- Intercept Depth: 425.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:425.85-427
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade gold intercept in the hanging wall zone.

Evidence · table

> 0.10

Context: 1.15

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-87)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 9.75
- Grade Unit: g/t
- Intercept: 1.15 m
- True Width: 0.92 m
- From: 425.85 m
- To: 427 m
- Hole Depth: 456 m
- Intercept Depth: 425.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:425.85-427
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Low-grade silver intercept in the hanging wall zone.

Evidence · table

> 9.75

Context: 1.15

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-88)

Electrolode Critical Metals · gallium

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gallium
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 30.5
- Grade Unit: ppm
- Intercept: 1.15 m
- True Width: 0.92 m
- From: 425.85 m
- To: 427 m
- Hole Depth: 456 m
- Intercept Depth: 425.85 m

#### Classification

- Deposit Type: vms
- Program: mixed
- Sample Type: drill
- Group ID: EL-26-006:425.85-427
- Mining Method: unknown

#### Location

- Location: HW
- Easting: 512426
- Northing: 5649233
- CRS: NAD83 / Zone 15
- Elevation: 401.8 m
- Azimuth: 138 °
- Dip: -65 °
- Loc. Confidence: high
- Loc. Source: document

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Deleterious

- Deleterious Flag: No

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Elevated gallium values, indicating potential for additional value.

Evidence · table

> 30.50

Context: 1.15

#### Tags used in scoring

**True Width Disclosed**

Polarity: positive

Definition: Actual thickness perpendicular to structure is stated, not just downhole length.

Why it applies: true\_width\_m is 0.92

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

**Infill Drilling**

Polarity: neutral

Definition: Confirmatory drilling to raise resource confidence, not new discovery.

Why it applies: drill\_program\_type is "mixed"

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-89)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 20.14
- Grade Unit: %
- Intercept: 1.7 m
- From: 342.8 m
- To: 344.5 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:342.8-344.5
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 20.14 % zinc is exceptional against the default band \[18, 10, 5, 2\] %. Grade×width 34.2 %·m is weak \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 20.14 % zinc is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 20.14

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-90)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.89
- Grade Unit: %
- Intercept: 1.7 m
- From: 342.8 m
- To: 344.5 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:342.8-344.5
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.89 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.5 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.89

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-91)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.37
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 342.8 m
- To: 344.5 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:342.8-344.5
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.37 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.6 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.37

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-92)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 112.29
- Grade Unit: g/t
- Intercept: 1.7 m
- From: 342.8 m
- To: 344.5 m
- Intercept Depth: 342.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:342.8-344.5
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 112.29 g/t silver is moderate against the default band \[500, 200, 100, 30\] g/t. Grade×width 190.9 g/t·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 112.29

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-93)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 20.44
- Grade Unit: %
- Intercept: 1.45 m
- From: 380.1 m
- To: 381.55 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:380.1-381.55
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 20.44 % zinc is exceptional against the default band \[18, 10, 5, 2\] %. Grade×width 29.6 %·m is weak \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 20.44 % zinc is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 20.44

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-94)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.98
- Grade Unit: %
- Intercept: 1.45 m
- From: 380.1 m
- To: 381.55 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:380.1-381.55
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.98 % copper is moderate against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.4 %·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.98

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-95)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.21
- Grade Unit: g/t
- Intercept: 1.45 m
- From: 380.1 m
- To: 381.55 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:380.1-381.55
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.3 g/t·m is below.

- Negative factor: 0.21 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.21

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-96)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 39.07
- Grade Unit: g/t
- Intercept: 1.45 m
- From: 380.1 m
- To: 381.55 m
- Intercept Depth: 380.1 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:380.1-381.55
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 39.07 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 56.7 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 39.07

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-97)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 16.91
- Grade Unit: %
- Intercept: 1.91 m
- From: 410.8 m
- To: 412.71 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:410.8-412.71
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 16.91 % zinc is strong against the default band \[18, 10, 5, 2\] %. Grade×width 32.3 %·m is weak \(grade alone is strong; the better of the two is used\).

- Positive factor: 16.91 % zinc is strong on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 16.91

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-98)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 3.59
- Grade Unit: %
- Intercept: 1.91 m
- From: 410.8 m
- To: 412.71 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:410.8-412.71
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 3.59 % copper is exceptional against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 6.9 %·m is below \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 3.59 % copper is exceptional on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 3.59

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-99)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1.33
- Grade Unit: g/t
- Intercept: 1.91 m
- From: 410.8 m
- To: 412.71 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:410.8-412.71
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 1.33 g/t gold is moderate against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 2.5 g/t·m is below \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.33

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-100)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 116.77
- Grade Unit: g/t
- Intercept: 1.91 m
- From: 410.8 m
- To: 412.71 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:410.8-412.71
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 116.77 g/t silver is moderate against the default band \[500, 200, 100, 30\] g/t. Grade×width 223.0 g/t·m is weak \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 116.77

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Also Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-101)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: Also Incl.
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 38.2
- Grade Unit: %
- Intercept: 0.42 m
- From: 410.8 m
- To: 411.22 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Also Incl.:410.8-411.22
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 38.2 % zinc is exceptional against the default band \[18, 10, 5, 2\] %. Grade×width 16.0 %·m is weak \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 38.2 % zinc is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 38.20

Context: Also Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Also Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-102)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: Also Incl.
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.14
- Grade Unit: %
- Intercept: 0.42 m
- From: 410.8 m
- To: 411.22 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Also Incl.:410.8-411.22
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.14 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.14 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.14

Context: Also Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Also Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-103)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: Also Incl.
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.41
- Grade Unit: g/t
- Intercept: 0.42 m
- From: 410.8 m
- To: 411.22 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Also Incl.:410.8-411.22
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.41 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.2 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.41

Context: Also Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Also Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-104)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: Also Incl.
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 88.1
- Grade Unit: g/t
- Intercept: 0.42 m
- From: 410.8 m
- To: 411.22 m
- Intercept Depth: 410.8 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Also Incl.:410.8-411.22
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 88.1 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 37.0 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 88.10

Context: Also Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-105)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 8.4
- Grade Unit: %
- Intercept: 4 m
- From: 433 m
- To: 437 m
- Intercept Depth: 433 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-006:433-437
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 8.4 % zinc is moderate against the default band \[18, 10, 5, 2\] %. Grade×width 33.6 %·m is weak \(grade alone is moderate; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.40

Context: EL-26-006

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-106)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.4
- Grade Unit: %
- Intercept: 4 m
- From: 433 m
- To: 437 m
- Intercept Depth: 433 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-006:433-437
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.4 % copper is weak against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 1.6 %·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.40

Context: EL-26-006

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-107)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.35
- Grade Unit: g/t
- Intercept: 4 m
- From: 433 m
- To: 437 m
- Intercept Depth: 433 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-006:433-437
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.35 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 1.4 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.35

Context: EL-26-006

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-006

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-108)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-006
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 21.88
- Grade Unit: g/t
- Intercept: 4 m
- From: 433 m
- To: 437 m
- Intercept Depth: 433 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-006:433-437
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 21.88 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 87.5 g/t·m is below.

- Negative factor: 21.88 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 21.88

Context: EL-26-006

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-109)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 20.05
- Grade Unit: %
- Intercept: 1.54 m
- From: 435 m
- To: 436.54 m
- Intercept Depth: 435 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:435-436.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 20.05 % zinc is exceptional against the default band \[18, 10, 5, 2\] %. Grade×width 30.9 %·m is weak \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 20.05 % zinc is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 20.05

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-110)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.23
- Grade Unit: %
- Intercept: 1.54 m
- From: 435 m
- To: 436.54 m
- Intercept Depth: 435 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:435-436.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.23 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.4 %·m is below.

- Negative factor: 0.23 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.23

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-111)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.33
- Grade Unit: g/t
- Intercept: 1.54 m
- From: 435 m
- To: 436.54 m
- Intercept Depth: 435 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:435-436.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.33 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.5 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.33

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Includes

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-112)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: Includes
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 27.54
- Grade Unit: g/t
- Intercept: 1.54 m
- From: 435 m
- To: 436.54 m
- Intercept Depth: 435 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Includes:435-436.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 27.54 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 42.4 g/t·m is below.

- Negative factor: 27.54 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 27.54

Context: Includes

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Also Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-113)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: Also Incl.
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 37.38
- Grade Unit: %
- Intercept: 0.73 m
- From: 435.81 m
- To: 436.54 m
- Intercept Depth: 435.81 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Also Incl.:435.81-436.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 37.38 % zinc is exceptional against the default band \[18, 10, 5, 2\] %. Grade×width 27.3 %·m is weak \(grade alone is exceptional; the better of the two is used\).

- Positive factor: 37.38 % zinc is exceptional on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 37.38

Context: Also Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Also Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-114)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: Also Incl.
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.27
- Grade Unit: %
- Intercept: 0.73 m
- From: 435.81 m
- To: 436.54 m
- Intercept Depth: 435.81 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Also Incl.:435.81-436.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.27 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.27 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.27

Context: Also Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Also Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-115)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: Also Incl.
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.45
- Grade Unit: g/t
- Intercept: 0.73 m
- From: 435.81 m
- To: 436.54 m
- Intercept Depth: 435.81 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Also Incl.:435.81-436.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.45 g/t gold is weak against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.3 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.45

Context: Also Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### Also Incl.

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-116)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: Also Incl.
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 40.35
- Grade Unit: g/t
- Intercept: 0.73 m
- From: 435.81 m
- To: 436.54 m
- Intercept Depth: 435.81 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: Also Incl.:435.81-436.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 40.35 g/t silver is weak against the default band \[500, 200, 100, 30\] g/t. Grade×width 29.5 g/t·m is below \(grade alone is weak; the better of the two is used\).

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 40.35

Context: Also Incl.

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-117)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-007
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.52
- Grade Unit: %
- Intercept: 1.4 m
- From: 100 m
- To: 101.4 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-007:100-101.4
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.52 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.7 %·m is below.

- Negative factor: 0.52 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.52

Context: EL-26-007

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-118)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-007
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.05
- Grade Unit: %
- Intercept: 1.4 m
- From: 100 m
- To: 101.4 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-007:100-101.4
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.05 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.05

Context: EL-26-007

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-119)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-007
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.03
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 100 m
- To: 101.4 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-007:100-101.4
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.03 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: EL-26-007

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-007

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-120)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-007
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 8.23
- Grade Unit: g/t
- Intercept: 1.4 m
- From: 100 m
- To: 101.4 m
- Intercept Depth: 100 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-007:100-101.4
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 8.23 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 11.5 g/t·m is below.

- Negative factor: 8.23 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 8.23

Context: EL-26-007

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-008A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-121)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-008A
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.32
- Grade Unit: %
- Intercept: 1.04 m
- From: 120.5 m
- To: 121.54 m
- Intercept Depth: 120.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-008A:120.5-121.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.32 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.3 %·m is below.

- Negative factor: 0.32 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.32

Context: EL-26-008A

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-008A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-122)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-008A
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 1.04 m
- From: 120.5 m
- To: 121.54 m
- Intercept Depth: 120.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-008A:120.5-121.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: EL-26-008A

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-008A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-123)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-008A
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 1.04 m
- From: 120.5 m
- To: 121.54 m
- Intercept Depth: 120.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-008A:120.5-121.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: EL-26-008A

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-008A

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-124)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-008A
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.66
- Grade Unit: g/t
- Intercept: 1.04 m
- From: 120.5 m
- To: 121.54 m
- Intercept Depth: 120.5 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-008A:120.5-121.54
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.66 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 0.7 g/t·m is below.

- Negative factor: 0.66 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.66

Context: EL-26-008A

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-125)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-009
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.1
- Grade Unit: %
- Intercept: 0.58 m
- From: 132.3 m
- To: 132.88 m
- Intercept Depth: 132.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-009:132.3-132.88
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 0.1 %·m is below.

- Negative factor: 0.1 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.10

Context: EL-26-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-126)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-009
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.01
- Grade Unit: %
- Intercept: 0.58 m
- From: 132.3 m
- To: 132.88 m
- Intercept Depth: 132.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-009:132.3-132.88
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.0 %·m is below.

- Negative factor: 0.01 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: EL-26-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-127)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-009
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 0.58 m
- From: 132.3 m
- To: 132.88 m
- Intercept Depth: 132.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-009:132.3-132.88
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.0 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: EL-26-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-009

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-128)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-009
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 2.15
- Grade Unit: g/t
- Intercept: 0.58 m
- From: 132.3 m
- To: 132.88 m
- Intercept Depth: 132.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-009:132.3-132.88
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 2.15 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 1.2 g/t·m is below.

- Negative factor: 2.15 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 2.15

Context: EL-26-009

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-129)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-010
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.28
- Grade Unit: %
- Intercept: 6.8 m
- From: 87 m
- To: 93.8 m
- Intercept Depth: 87 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-010:87-93.8
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.28 % zinc is below against the default band \[18, 10, 5, 2\] %. Grade×width 1.9 %·m is below.

- Negative factor: 0.28 % zinc is below the weak threshold \(2 %\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.28

Context: EL-26-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-130)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-010
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.03
- Grade Unit: %
- Intercept: 6.8 m
- From: 87 m
- To: 93.8 m
- Intercept Depth: 87 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-010:87-93.8
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.03 % copper is below against the vms deposit band \[2.5, 1.5, 0.8, 0.4\] %. Grade×width 0.2 %·m is below.

- Negative factor: 0.03 % copper is below the weak threshold \(0.4 %\) on the vms deposit band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.03

Context: EL-26-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-131)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-010
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.01
- Grade Unit: g/t
- Intercept: 6.8 m
- From: 87 m
- To: 93.8 m
- Intercept Depth: 87 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-010:87-93.8
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 g/t gold is below against the default band \[5, 2, 1, 0.3\] g/t. Grade×width 0.1 g/t·m is below.

- Negative factor: 0.01 g/t gold is below the weak threshold \(0.3 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 0.01

Context: EL-26-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-010

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-132)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-010
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1.92
- Grade Unit: g/t
- Intercept: 6.8 m
- From: 87 m
- To: 93.8 m
- Intercept Depth: 87 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-010:87-93.8
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table. 1.92 g/t silver is below against the default band \[500, 200, 100, 30\] g/t. Grade×width 13.1 g/t·m is below.

- Negative factor: 1.92 g/t silver is below the weak threshold \(30 g/t\) on the default band.

- Negative factor: Scored from rubric bands during table expansion, not from document context.

Evidence · table

> 1.92

Context: EL-26-010

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-133)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-001
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 38
- Grade Unit: ppm
- Intercept: 1.2 m
- From: 339.3 m
- To: 340.5 m
- Intercept Depth: 339.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-001:339.3-340.5
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 38 ppm zinc, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the zinc rubric unit %; not scored.

Evidence · table

> 38

Context: EL-26-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-134)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-001
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 3270
- Grade Unit: ppm
- Intercept: 1.2 m
- From: 339.3 m
- To: 340.5 m
- Intercept Depth: 339.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-001:339.3-340.5
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 3270 ppm copper, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the copper rubric unit %; not scored.

Evidence · table

> 3270

Context: EL-26-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-135)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-001
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.68
- Grade Unit: ppm
- Intercept: 1.2 m
- From: 339.3 m
- To: 340.5 m
- Intercept Depth: 339.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-001:339.3-340.5
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 0.68 ppm gold, reported in a unit the rubric does not cover \(g/t\).

- Negative factor: Grade unit ppm does not match the gold rubric unit g/t; not scored.

Evidence · table

> 0.68

Context: EL-26-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-136)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-001
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 5.35
- Grade Unit: ppm
- Intercept: 1.2 m
- From: 339.3 m
- To: 340.5 m
- Intercept Depth: 339.3 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-001:339.3-340.5
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 5.35 ppm silver, reported in a unit the rubric does not cover \(g/t\).

- Negative factor: Grade unit ppm does not match the silver rubric unit g/t; not scored.

Evidence · table

> 5.35

Context: EL-26-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-137)

Electrolode Critical Metals · zinc

#### Identity

- Hole ID: EL-26-001
- Project: Electrolode Critical Metals
- Commodity: zinc
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 1530
- Grade Unit: ppm
- Intercept: 3 m
- From: 486 m
- To: 489 m
- Intercept Depth: 486 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-001:486-489
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 1530 ppm zinc, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the zinc rubric unit %; not scored.

Evidence · table

> 1530

Context: EL-26-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-138)

Electrolode Critical Metals · copper

#### Identity

- Hole ID: EL-26-001
- Project: Electrolode Critical Metals
- Commodity: copper
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 59
- Grade Unit: ppm
- Intercept: 3 m
- From: 486 m
- To: 489 m
- Intercept Depth: 486 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-001:486-489
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 59 ppm copper, reported in a unit the rubric does not cover \(%\).

- Negative factor: Grade unit ppm does not match the copper rubric unit %; not scored.

Evidence · table

> 59

Context: EL-26-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-139)

Electrolode Critical Metals · gold

#### Identity

- Hole ID: EL-26-001
- Project: Electrolode Critical Metals
- Commodity: gold
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0
- Grade Unit: ppm
- Intercept: 3 m
- From: 486 m
- To: 489 m
- Intercept Depth: 486 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-001:486-489
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 0 ppm gold, reported in a unit the rubric does not cover \(g/t\).

- Negative factor: Grade unit ppm does not match the gold rubric unit g/t; not scored.

Evidence · table

> 0.00

Context: EL-26-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

### EL-26-001

[Link to this fact](https://atlas-extractions.minestarters.com/news/total-metals-reports-positive-results-at-its-electrolode-critical-metals-project--a11f85e2-12c3-4de3-8996-ebf24b387028#fact-drill-facts-140)

Electrolode Critical Metals · silver

#### Identity

- Hole ID: EL-26-001
- Project: Electrolode Critical Metals
- Commodity: silver
- Region: canada\_on
- Reported Region: canada\_on
- Ticker: TT

#### Geometry

- Grade: 0.21
- Grade Unit: ppm
- Intercept: 3 m
- From: 486 m
- To: 489 m
- Intercept Depth: 486 m

#### Classification

- Deposit Type: vms
- Sample Type: drill
- Group ID: EL-26-001:486-489
- Mining Method: unknown

#### Location

- CRS: NAD83 / Zone 15

#### QA/QC

- Laboratory: AGAT Laboratories Ltd.
- QA/QC Disclosed: Yes
- QP Signed: Yes
- QA/QC Methods: standards, blanks

#### Review

- Needs Review: No
- Interp. Status: scored
- Historical: No

#### Dates

- Event date: 2026-06-22T00:00:00.000Z

Reasoning: Expanded from assay table: 0.21 ppm silver, reported in a unit the rubric does not cover \(g/t\).

- Negative factor: Grade unit ppm does not match the silver rubric unit g/t; not scored.

Evidence · table

> 0.21

Context: EL-26-001

#### Tags used in scoring

**QA/QC Disclosed**

Polarity: positive

Definition: Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods \(blanks, standards, duplicates\).

Why it applies: qaqc\_disclosed is true

**Cut-off Undisclosed**

Polarity: negative

Definition: High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff\_grade was stated

## How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.
