Total Metals Reports Remaining Results from Winter 2026 Exploration Program at its Electrolode Critical Metals Project

Original announcement by tmx on

Company
Total Metals Corp.
Ticker
TT
Exchange
TSX
Region
northwestern Ontario
Primary commodity
Zinc
Secondary commodities
Copper, Gold, Silver, Gallium, Indium
Document categories
Drill results
Extracted
2026-09-17 02:42:58 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Total Metals Corp. announced the remaining drill results from its winter 2026 exploration program at the Electrolode Critical Metals Project in northwestern Ontario. The program, comprising 25 holes totaling 8,408 metres, targeted VMS deposits in the Copperlode area and other exploration targets. Highlights include a high-grade intercept in hole EL-26-013 from the Hornet Zone, returning 2.90% Zn, 1.15% Cu, 0.06 g/t Au, and 13.30 g/t Ag over 7.67 metres. The company noted that the program successfully upgraded the geological model and confirmed significant expansion potential for the Arrow and Hornet Zones, with plans for further exploration.

Reasoning: The drill program successfully identified significant mineralization, particularly a high-grade copper-zinc intercept in hole EL-26-013, and confirmed the potential for resource expansion at the Electrolode project. The results are supported by robust QA/QC, though the lack of true width estimates is a minor drawback.

Positive factors

  • High-grade copper-zinc intercept in EL-26-013 from the Hornet Zone, which is strong for VMS copper and moderate for VMS zinc.
  • Confirmation of expansion potential for the Arrow and Hornet Zones, indicating future resource growth.
  • Detailed QA/QC procedures disclosed, including certified lab, standards, blanks, umpire, and check assays, enhancing data credibility.
  • Identification of new targets and successful testing of geophysical anomalies.

Negative factors

  • True thickness estimates are not available for reported intercepts, which may overstate actual widths.
  • Several holes returned no significant assay results (NSV), indicating some barren or low-grade intercepts.

Low confidence — this extraction should be reviewed alongside the original source.

Facts used in scoring: 107

Classification and evidence

Step-Out Extensionpositive

Mineralization extended beyond the previously known limit.

Why it applies: The company explicitly states that the 'Arrow and Hornet Zones remain wide open for expansion' and that the project has 'considerable potential remaining for increasing metal resources'.

Evidence · text

“Arrow and Hornet Zones remain wide open for expansion”

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: The release details QA/QC protocols, including the use of certified reference material standards, blanks, and analysis by AGAT Laboratories Ltd., with a subset verified by a third-party lab.

Evidence · text

“Protocols for core logging, sampling and QAQC were developed together with Bayside Geoscience Inc., who managed project site exploration activities on behalf of and under direction of the Company during the duration of the winter drilling program. Drilling was contracted to Platinum Diamond Drilling Inc. with NQ2 size core produced. Once the core was logged and marked for sampling, samples were sawn in half. Certified reference material standards and blanks were inserted into the sample sequence on a rotating basis and together combined with sealed samples in zip tie secured rice bags and securely delivered by Bayside personnel to AGAT Laboratories Ltd. All sample preparation and 30 g fire assay ICP-OES finish was completed in Thunder Bay and all 4-Acid digestion and 48 multi-element analysis (ICP-OES/ICP-MS finish) was done at AGAT’s Calgary location. Samples >1% Zn, >1% Cu and >100 g/t Ag were reanalyzed as over limit with AGAT’s 4-Acid Metals Package (ICP-OES and/or ICP-MS finish). Internal laboratory standards and blanks were also analyzed by AGAT and reported with the certified assay results. A selected subset of mineralized sample pulps and additional CRMs were shipped and analyzed by a third-party lab independent of AGAT for further verification.”

Apparent Width Onlynegative

Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.

Why it applies: The document explicitly states that reported lengths are 'core length' and 'True thickness estimates not available'.

Evidence · text

“*Reported as core length. True thickness estimates not available.”

Extracted facts

Stored fact records: 107. Some facts used in scoring do not have a stored record.

Drill Results (107)

EL-26-011ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-011
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
345 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Copperlode
Easting
507499
Northing
5645662
CRS
NAD83 / Zone 15
Elevation
390.2 m
Azimuth
149 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc and copper mineralization over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc and copper.
  • True thickness not available.

Evidence · table

“EL-26-011”

Context: 507499

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-012ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-012
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
345 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
S-CL Fault
Easting
507100
Northing
5645462
CRS
NAD83 / Zone 15
Elevation
391.5 m
Azimuth
153 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This hole returned no significant assay results, which is a negative outcome for an exploration target, though it may provide geological information.

Negative factors

  • No significant assay results reported, indicating a barren or very low-grade intercept.

Evidence · table

“EL-26-012”

Context: 507100

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
516 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Copperlode
Easting
508096
Northing
5645799
CRS
NAD83 / Zone 15
Elevation
390.9 m
Azimuth
154 °
Dip
-62 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept represents a strong result for VMS copper and moderate for VMS zinc over a good width, indicating significant mineralization in the Hornet Zone, further enhanced by critical metal byproducts.

Positive factors

  • High-grade copper and moderate-grade zinc for a VMS deposit.
  • Significant intercept length of 7.67m.
  • Elevated gallium and indium values, indicating potential for critical metals.

Negative factors

  • True thickness not available.

Evidence · table

“EL-26-013”

Context: 508096

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-014ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-014
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
450 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Copperlode
Easting
507302
Northing
5645601
CRS
NAD83 / Zone 15
Elevation
387.8 m
Azimuth
195 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc and copper mineralization over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc and copper.
  • True thickness not available.

Evidence · table

“EL-26-014”

Context: 507302

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-015ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-015
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
336 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
L13 Target
Easting
507109
Northing
5645018
CRS
NAD83 / Zone 15
Elevation
383.7 m
Azimuth
145 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This hole returned no significant assay results, which is a negative outcome for an exploration target, though it may provide geological information.

Negative factors

  • No significant assay results reported, indicating a barren or very low-grade intercept.

Evidence · table

“EL-26-015”

Context: 507109

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
513.44 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Copperlode
Easting
508157
Northing
5645850
CRS
NAD83 / Zone 15
Elevation
392.5 m
Azimuth
152 °
Dip
-59 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc and copper mineralization over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc and copper.
  • True thickness not available.

Evidence · table

“EL-26-016”

Context: 508157

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-017ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-017
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
303 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
L5 Target
Easting
508207
Northing
5646570
CRS
NAD83 / Zone 15
Elevation
403.2 m
Azimuth
295 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows a strong copper grade over a narrow width, which is a positive indicator for VMS mineralization, but the zinc grade is low.

Positive factors

  • Strong copper grade for a VMS deposit.

Negative factors

  • Narrow intercept length.
  • Low zinc grade.
  • True thickness not available.

Evidence · table

“EL-26-017”

Context: 508207

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-018ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-018
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
390 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Far East
Easting
510459
Northing
5647966
CRS
NAD83 / Zone 15
Elevation
402.1 m
Azimuth
155 °
Dip
-63 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows a moderate zinc grade over a narrow width, which is a positive indicator, especially as it's associated with a newly identified deep conductor, suggesting exploration upside.

Positive factors

  • Moderate zinc grade for a VMS deposit.
  • Identified a previously unknown deep conductor.

Negative factors

  • Narrow intercept length.
  • Low copper grade.
  • True thickness not available.

Evidence · table

“EL-26-018”

Context: 510459

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-019ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-019
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
528 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Copperlode
Easting
508212
Northing
5645866
CRS
NAD83 / Zone 15
Elevation
390.3 m
Azimuth
158 °
Dip
-65 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc and copper mineralization over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc and copper.
  • True thickness not available.

Evidence · table

“EL-26-019”

Context: 508212

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
318 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Far East
Easting
510747
Northing
5648113
CRS
NAD83 / Zone 15
Elevation
400.3 m
Azimuth
135 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: These intercepts show low-grade zinc and copper mineralization over narrow to moderate widths, which are not highly significant but confirm mineralization in the Far East L1 and L2 targets.

Negative factors

  • Low grades for VMS zinc and copper.
  • True thickness not available.

Evidence · table

“EL-26-020”

Context: 510747

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-021ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-021
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
201 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Far East
Easting
510834
Northing
5647965
CRS
NAD83 / Zone 15
Elevation
396.4 m
Azimuth
135 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc and copper mineralization over a narrow width, which is not highly significant but confirms mineralization in the Far East L1 target.

Negative factors

  • Low grades for VMS zinc and copper.
  • True thickness not available.

Evidence · table

“EL-26-021”

Context: 510834

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-022ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-022
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
354 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Far East
Easting
510949
Northing
5648280
CRS
NAD83 / Zone 15
Elevation
404.3 m
Azimuth
131 °
Dip
-45 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This hole returned no significant assay results, which is a negative outcome for an exploration target, though it may provide geological information.

Negative factors

  • No significant assay results reported, indicating a barren or very low-grade intercept.

Evidence · table

“EL-26-022”

Context: 510949

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-023ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-023
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
129 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Copperlode
Easting
508308
Northing
5645873
CRS
NAD83 / Zone 15
Elevation
390.3 m
Azimuth
153 °
Dip
-67 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This hole was abandoned before reaching its target and yielded no significant results, representing a clear negative outcome for this specific drill attempt.

Negative factors

  • Hole abandoned before reaching target, indicating a failed drill attempt.
  • No significant assay results reported.

Evidence · table

“EL-26-023*”

Context: 508308

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-024ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-024
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
458 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Copperlode
Easting
508309
Northing
5645874
CRS
NAD83 / Zone 15
Elevation
390.6 m
Azimuth
139 °
Dip
-66 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc and copper mineralization over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc and copper.
  • True thickness not available.

Evidence · table

“EL-26-024”

Context: 508309

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-025ElectrolodeView all details
Link to this fact

Identity

Hole ID
EL-26-025
Project
Electrolode
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Hole Depth
240 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Mining Method
underground

Location

Location
Garnet Lake
Easting
511606
Northing
5648579
CRS
NAD83 / Zone 15
Elevation
401.2 m
Azimuth
142 °
Dip
-50 °
Loc. Confidence
high
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc and copper mineralization over a moderate width, which is not highly significant but confirms mineralization in the GL-3 Plate target.

Negative factors

  • Low grades for VMS zinc and copper.
  • True thickness not available.

Evidence · table

“EL-26-025”

Context: 511606

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-011Electrolode · zincGrade: 0.78Grade Unit: %Intercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
EL-26-011
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.78
Grade Unit
%
Intercept
2.95 m
From
119.05 m
To
122 m
Intercept Depth
119.05 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-011:119.05-122
Mining Method
underground

Location

Location
C Zone / CL-N
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.78”

Context: EL-26-011

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-011Electrolode · copperGrade: 0.05Grade Unit: %Intercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
EL-26-011
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.05
Grade Unit
%
Intercept
2.95 m
From
119.05 m
To
122 m
Intercept Depth
119.05 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-011:119.05-122
Mining Method
underground

Location

Location
C Zone / CL-N
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.05”

Context: EL-26-011

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-011Electrolode · goldGrade: 0Grade Unit: ppmIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
EL-26-011
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0
Grade Unit
ppm
Intercept
2.95 m
From
119.05 m
To
122 m
Intercept Depth
119.05 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-011:119.05-122
Mining Method
underground

Location

Location
C Zone / CL-N
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows no gold grade, which is not significant, and true thickness is not provided.

Negative factors

  • No gold grade reported.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.00”

Context: EL-26-011

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-011Electrolode · silverGrade: 2.72Grade Unit: ppmIntercept: 2.95 mView all details
Link to this fact

Identity

Hole ID
EL-26-011
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
2.72
Grade Unit
ppm
Intercept
2.95 m
From
119.05 m
To
122 m
Intercept Depth
119.05 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-011:119.05-122
Mining Method
underground

Location

Location
C Zone / CL-N
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“2.72”

Context: EL-26-011

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · zincGrade: 1.24Grade Unit: %Intercept: 1.01 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.24
Grade Unit
%
Intercept
1.01 m
From
410.6 m
To
411.17 m
Intercept Depth
410.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:410.6-411.17
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc over a very narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“1.24”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · copperGrade: 0.06Grade Unit: %Intercept: 1.01 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.06
Grade Unit
%
Intercept
1.01 m
From
410.6 m
To
411.17 m
Intercept Depth
410.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:410.6-411.17
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a very narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.06”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · goldGrade: 0.01Grade Unit: ppmIntercept: 1.01 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
ppm
Intercept
1.01 m
From
410.6 m
To
411.17 m
Intercept Depth
410.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:410.6-411.17
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.01”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · silverGrade: 10.35Grade Unit: ppmIntercept: 1.01 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
10.35
Grade Unit
ppm
Intercept
1.01 m
From
410.6 m
To
411.17 m
Intercept Depth
410.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:410.6-411.17
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver over a very narrow width, which is not particularly significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“10.35”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · zincGrade: 2.9Grade Unit: %Intercept: 7.67 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
2.9
Grade Unit
%
Intercept
7.67 m
From
470.72 m
To
478.39 m
Intercept Depth
470.72 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:470.72-478.39
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows a moderate zinc grade over a good width, indicating significant mineralization in the Hornet Zone, further enhanced by critical metal byproducts.

Positive factors

  • Moderate grade for VMS zinc.
  • Significant intercept length of 7.67m.
  • Elevated gallium and indium values, indicating potential for critical metals.

Negative factors

  • True thickness not available.

Evidence · table

“2.90”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · copperGrade: 1.15Grade Unit: %Intercept: 7.67 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.15
Grade Unit
%
Intercept
7.67 m
From
470.72 m
To
478.39 m
Intercept Depth
470.72 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:470.72-478.39
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows a strong copper grade over a good width, indicating significant mineralization in the Hornet Zone, further enhanced by critical metal byproducts.

Positive factors

  • Strong grade for VMS copper.
  • Significant intercept length of 7.67m.
  • Elevated gallium and indium values, indicating potential for critical metals.

Negative factors

  • True thickness not available.

Evidence · table

“1.15”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · goldGrade: 0.06Grade Unit: ppmIntercept: 7.67 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.06
Grade Unit
ppm
Intercept
7.67 m
From
470.72 m
To
478.39 m
Intercept Depth
470.72 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:470.72-478.39
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade gold, which is not particularly significant, and true thickness is not provided.

Negative factors

  • Low gold grade.
  • True thickness not available.

Evidence · table

“0.06”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · silverGrade: 13.3Grade Unit: ppmIntercept: 7.67 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
13.3
Grade Unit
ppm
Intercept
7.67 m
From
470.72 m
To
478.39 m
Intercept Depth
470.72 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:470.72-478.39
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not particularly significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • True thickness not available.

Evidence · table

“13.30”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · zincGrade: 4.02Grade Unit: %Intercept: 3.36 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
4.02
Grade Unit
%
Intercept
3.36 m
From
475.03 m
To
478.39 m
Intercept Depth
475.03 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:475.03-478.39
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This sub-interval shows a moderate zinc grade over a good width, contributing positively to the overall intercept, though true thickness is not provided.

Positive factors

  • Moderate grade for VMS zinc.
  • Good intercept length for a sub-interval.

Negative factors

  • True thickness not available.

Evidence · table

“4.02”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · copperGrade: 1.25Grade Unit: %Intercept: 3.36 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.25
Grade Unit
%
Intercept
3.36 m
From
475.03 m
To
478.39 m
Intercept Depth
475.03 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:475.03-478.39
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This sub-interval shows a strong copper grade over a good width, significantly contributing to the overall intercept, though true thickness is not provided.

Positive factors

  • Strong grade for VMS copper.
  • Good intercept length for a sub-interval.

Negative factors

  • True thickness not available.

Evidence · table

“1.25”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · goldGrade: 0.11Grade Unit: ppmIntercept: 3.36 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.11
Grade Unit
ppm
Intercept
3.36 m
From
475.03 m
To
478.39 m
Intercept Depth
475.03 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:475.03-478.39
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This sub-interval shows low-grade gold, which is not particularly significant, and true thickness is not provided.

Negative factors

  • Low gold grade.
  • True thickness not available.

Evidence · table

“0.11”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · silverGrade: 15.38Grade Unit: ppmIntercept: 3.36 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
15.38
Grade Unit
ppm
Intercept
3.36 m
From
475.03 m
To
478.39 m
Intercept Depth
475.03 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:475.03-478.39
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This sub-interval shows low-grade silver, which is not particularly significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • True thickness not available.

Evidence · table

“15.38”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · zincGrade: 3.62Grade Unit: %Intercept: 1.74 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.62
Grade Unit
%
Intercept
1.74 m
From
474.58 m
To
476.32 m
Intercept Depth
474.58 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:474.58-476.32
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This sub-interval shows a moderate zinc grade over a good width, contributing positively to the overall intercept, though true thickness is not provided.

Positive factors

  • Moderate grade for VMS zinc.
  • Good intercept length for a sub-interval.

Negative factors

  • True thickness not available.

Evidence · table

“3.62”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · copperGrade: 3.19Grade Unit: %Intercept: 1.74 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.19
Grade Unit
%
Intercept
1.74 m
From
474.58 m
To
476.32 m
Intercept Depth
474.58 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:474.58-476.32
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This sub-interval shows an exceptional copper grade over a good width, significantly enhancing the overall intercept and indicating very high-grade mineralization, though true thickness is not provided.

Positive factors

  • Exceptional grade for VMS copper.
  • Good intercept length for a sub-interval.

Negative factors

  • True thickness not available.

Evidence · table

“3.19”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · goldGrade: 0.23Grade Unit: ppmIntercept: 1.74 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.23
Grade Unit
ppm
Intercept
1.74 m
From
474.58 m
To
476.32 m
Intercept Depth
474.58 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:474.58-476.32
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This sub-interval shows low-grade gold, which is not particularly significant, and true thickness is not provided.

Negative factors

  • Low gold grade.
  • True thickness not available.

Evidence · table

“0.23”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · silverGrade: 37.29Grade Unit: ppmIntercept: 1.74 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
37.29
Grade Unit
ppm
Intercept
1.74 m
From
474.58 m
To
476.32 m
Intercept Depth
474.58 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:474.58-476.32
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This sub-interval shows low-grade silver, which is not particularly significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • True thickness not available.

Evidence · table

“37.29”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · zincGrade: 4.29Grade Unit: %Intercept: 0.74 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
4.29
Grade Unit
%
Intercept
0.74 m
From
495.2 m
To
495.94 m
Intercept Depth
495.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:495.2-495.94
Mining Method
underground

Location

Location
FW to Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows a moderate zinc grade, but over a very narrow width, limiting its overall significance, and true thickness is not provided.

Positive factors

  • Moderate grade for VMS zinc.

Negative factors

  • Very narrow intercept length.
  • True thickness not available.

Evidence · table

“4.29”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · copperGrade: 0.07Grade Unit: %Intercept: 0.74 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.07
Grade Unit
%
Intercept
0.74 m
From
495.2 m
To
495.94 m
Intercept Depth
495.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:495.2-495.94
Mining Method
underground

Location

Location
FW to Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a very narrow width, which is not significant, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Very narrow intercept length.
  • True thickness not available.

Evidence · table

“0.07”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · goldGrade: 0.01Grade Unit: ppmIntercept: 0.74 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
ppm
Intercept
0.74 m
From
495.2 m
To
495.94 m
Intercept Depth
495.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:495.2-495.94
Mining Method
underground

Location

Location
FW to Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Very narrow intercept length.
  • True thickness not available.

Evidence · table

“0.01”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-013Electrolode · silverGrade: 4.82Grade Unit: ppmIntercept: 0.74 mView all details
Link to this fact

Identity

Hole ID
EL-26-013
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
4.82
Grade Unit
ppm
Intercept
0.74 m
From
495.2 m
To
495.94 m
Intercept Depth
495.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-013:495.2-495.94
Mining Method
underground

Location

Location
FW to Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Very narrow intercept length.
  • True thickness not available.

Evidence · table

“4.82”

Context: EL-26-013

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-014Electrolode · zincGrade: 1.02Grade Unit: %Intercept: 3.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-014
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.02
Grade Unit
%
Intercept
3.7 m
From
131.3 m
To
135 m
Intercept Depth
131.3 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-014:131.3-135
Mining Method
underground

Location

Location
C Zone / CL-S
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“1.02”

Context: EL-26-014

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-014Electrolode · copperGrade: 0.06Grade Unit: %Intercept: 3.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-014
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.06
Grade Unit
%
Intercept
3.7 m
From
131.3 m
To
135 m
Intercept Depth
131.3 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-014:131.3-135
Mining Method
underground

Location

Location
C Zone / CL-S
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.06”

Context: EL-26-014

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-014Electrolode · goldGrade: 0Grade Unit: ppmIntercept: 3.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-014
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0
Grade Unit
ppm
Intercept
3.7 m
From
131.3 m
To
135 m
Intercept Depth
131.3 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-014:131.3-135
Mining Method
underground

Location

Location
C Zone / CL-S
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows no gold grade, which is not significant, and true thickness is not provided.

Negative factors

  • No gold grade reported.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.00”

Context: EL-26-014

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-014Electrolode · silverGrade: 3.06Grade Unit: ppmIntercept: 3.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-014
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.06
Grade Unit
ppm
Intercept
3.7 m
From
131.3 m
To
135 m
Intercept Depth
131.3 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-014:131.3-135
Mining Method
underground

Location

Location
C Zone / CL-S
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“3.06”

Context: EL-26-014

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-014Electrolode · zincGrade: 0.38Grade Unit: %Intercept: 2.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-014
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.38
Grade Unit
%
Intercept
2.7 m
From
140.4 m
To
143.1 m
Intercept Depth
140.4 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-014:140.4-143.1
Mining Method
underground

Location

Location
FW to C Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade zinc over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.38”

Context: EL-26-014

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-014Electrolode · copperGrade: 0.1Grade Unit: %Intercept: 2.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-014
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.1
Grade Unit
%
Intercept
2.7 m
From
140.4 m
To
143.1 m
Intercept Depth
140.4 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-014:140.4-143.1
Mining Method
underground

Location

Location
FW to C Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.10”

Context: EL-26-014

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-014Electrolode · goldGrade: 0Grade Unit: ppmIntercept: 2.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-014
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0
Grade Unit
ppm
Intercept
2.7 m
From
140.4 m
To
143.1 m
Intercept Depth
140.4 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-014:140.4-143.1
Mining Method
underground

Location

Location
FW to C Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows no gold grade, which is not significant, and true thickness is not provided.

Negative factors

  • No gold grade reported.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.00”

Context: EL-26-014

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-014Electrolode · silverGrade: 5.79Grade Unit: ppmIntercept: 2.7 mView all details
Link to this fact

Identity

Hole ID
EL-26-014
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
5.79
Grade Unit
ppm
Intercept
2.7 m
From
140.4 m
To
143.1 m
Intercept Depth
140.4 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-014:140.4-143.1
Mining Method
underground

Location

Location
FW to C Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“5.79”

Context: EL-26-014

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · zincGrade: 0.85Grade Unit: %Intercept: 2.02 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.85
Grade Unit
%
Intercept
2.02 m
From
130.48 m
To
132.5 m
Intercept Depth
130.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:130.48-132.5
Mining Method
underground

Location

Location
E Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.85”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · copperGrade: 0.16Grade Unit: %Intercept: 2.02 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.16
Grade Unit
%
Intercept
2.02 m
From
130.48 m
To
132.5 m
Intercept Depth
130.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:130.48-132.5
Mining Method
underground

Location

Location
E Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.16”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · goldGrade: 0.04Grade Unit: ppmIntercept: 2.02 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.04
Grade Unit
ppm
Intercept
2.02 m
From
130.48 m
To
132.5 m
Intercept Depth
130.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:130.48-132.5
Mining Method
underground

Location

Location
E Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.04”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · silverGrade: 6.85Grade Unit: ppmIntercept: 2.02 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
6.85
Grade Unit
ppm
Intercept
2.02 m
From
130.48 m
To
132.5 m
Intercept Depth
130.48 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:130.48-132.5
Mining Method
underground

Location

Location
E Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“6.85”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · zincGrade: 1.89Grade Unit: %Intercept: 2.56 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.89
Grade Unit
%
Intercept
2.56 m
From
435.44 m
To
438 m
Intercept Depth
435.44 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:435.44-438
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“1.89”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · copperGrade: 0.04Grade Unit: %Intercept: 2.56 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.04
Grade Unit
%
Intercept
2.56 m
From
435.44 m
To
438 m
Intercept Depth
435.44 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:435.44-438
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.04”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · goldGrade: 0.01Grade Unit: ppmIntercept: 2.56 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
ppm
Intercept
2.56 m
From
435.44 m
To
438 m
Intercept Depth
435.44 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:435.44-438
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.01”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · silverGrade: 9.17Grade Unit: ppmIntercept: 2.56 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
9.17
Grade Unit
ppm
Intercept
2.56 m
From
435.44 m
To
438 m
Intercept Depth
435.44 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:435.44-438
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“9.17”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · zincGrade: 2.19Grade Unit: %Intercept: 1.95 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
2.19
Grade Unit
%
Intercept
1.95 m
From
466.26 m
To
468.21 m
Intercept Depth
466.26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:466.26-468.21
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows a weak zinc grade over a narrow width, which is a positive indicator but not highly significant, and true thickness is not provided.

Positive factors

  • Weak grade for VMS zinc.

Negative factors

  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“2.19”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · copperGrade: 0.12Grade Unit: %Intercept: 1.95 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.12
Grade Unit
%
Intercept
1.95 m
From
466.26 m
To
468.21 m
Intercept Depth
466.26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:466.26-468.21
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.12”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · goldGrade: 0.01Grade Unit: ppmIntercept: 1.95 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
ppm
Intercept
1.95 m
From
466.26 m
To
468.21 m
Intercept Depth
466.26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:466.26-468.21
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.01”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-016Electrolode · silverGrade: 22.98Grade Unit: ppmIntercept: 1.95 mView all details
Link to this fact

Identity

Hole ID
EL-26-016
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
22.98
Grade Unit
ppm
Intercept
1.95 m
From
466.26 m
To
468.21 m
Intercept Depth
466.26 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-016:466.26-468.21
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“22.98”

Context: EL-26-016

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-019Electrolode · zincGrade: 0.91Grade Unit: %Intercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-019
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.91
Grade Unit
%
Intercept
4.55 m
From
433.35 m
To
437.9 m
Intercept Depth
433.35 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-019:433.35-437.9
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc over a moderate width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc.
  • True thickness not available.

Evidence · table

“0.91”

Context: EL-26-019

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-019Electrolode · copperGrade: 0.18Grade Unit: %Intercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-019
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.18
Grade Unit
%
Intercept
4.55 m
From
433.35 m
To
437.9 m
Intercept Depth
433.35 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-019:433.35-437.9
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a moderate width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • True thickness not available.

Evidence · table

“0.18”

Context: EL-26-019

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-019Electrolode · goldGrade: 0.01Grade Unit: ppmIntercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-019
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
ppm
Intercept
4.55 m
From
433.35 m
To
437.9 m
Intercept Depth
433.35 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-019:433.35-437.9
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • True thickness not available.

Evidence · table

“0.01”

Context: EL-26-019

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-019Electrolode · silverGrade: 22.4Grade Unit: ppmIntercept: 4.55 mView all details
Link to this fact

Identity

Hole ID
EL-26-019
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
22.4
Grade Unit
ppm
Intercept
4.55 m
From
433.35 m
To
437.9 m
Intercept Depth
433.35 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-019:433.35-437.9
Mining Method
underground

Location

Location
D Zone
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • True thickness not available.

Evidence · table

“22.4”

Context: EL-26-019

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-019Electrolode · zincGrade: 3.19Grade Unit: %Intercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
EL-26-019
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.19
Grade Unit
%
Intercept
1.15 m
From
464.35 m
To
465.5 m
Intercept Depth
464.35 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-019:464.35-465.5
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows a moderate zinc grade over a narrow width, which is a positive indicator but not highly significant, and true thickness is not provided.

Positive factors

  • Moderate grade for VMS zinc.

Negative factors

  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“3.19”

Context: EL-26-019

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-019Electrolode · copperGrade: 0.1Grade Unit: %Intercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
EL-26-019
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.1
Grade Unit
%
Intercept
1.15 m
From
464.35 m
To
465.5 m
Intercept Depth
464.35 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-019:464.35-465.5
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.10”

Context: EL-26-019

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-019Electrolode · goldGrade: 0.01Grade Unit: ppmIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
EL-26-019
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
ppm
Intercept
1.15 m
From
464.35 m
To
465.5 m
Intercept Depth
464.35 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-019:464.35-465.5
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.01”

Context: EL-26-019

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-019Electrolode · silverGrade: 12.41Grade Unit: ppmIntercept: 1.15 mView all details
Link to this fact

Identity

Hole ID
EL-26-019
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
12.41
Grade Unit
ppm
Intercept
1.15 m
From
464.35 m
To
465.5 m
Intercept Depth
464.35 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-019:464.35-465.5
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“12.41”

Context: EL-26-019

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-024Electrolode · zincGrade: 1.69Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
EL-26-024
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.69
Grade Unit
%
Intercept
1.05 m
From
404.45 m
To
405.5 m
Intercept Depth
404.45 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-024:404.45-405.5
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“1.69”

Context: EL-26-024

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-024Electrolode · copperGrade: 0.01Grade Unit: %Intercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
EL-26-024
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
%
Intercept
1.05 m
From
404.45 m
To
405.5 m
Intercept Depth
404.45 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-024:404.45-405.5
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.01”

Context: EL-26-024

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-024Electrolode · goldGrade: 0.01Grade Unit: ppmIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
EL-26-024
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
ppm
Intercept
1.05 m
From
404.45 m
To
405.5 m
Intercept Depth
404.45 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-024:404.45-405.5
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.01”

Context: EL-26-024

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-024Electrolode · silverGrade: 5.18Grade Unit: ppmIntercept: 1.05 mView all details
Link to this fact

Identity

Hole ID
EL-26-024
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
5.18
Grade Unit
ppm
Intercept
1.05 m
From
404.45 m
To
405.5 m
Intercept Depth
404.45 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-024:404.45-405.5
Mining Method
underground

Location

Location
Hornet
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“5.18”

Context: EL-26-024

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-017Electrolode · zincGrade: 0.122Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
EL-26-017
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.122
Grade Unit
%
Intercept
1 m
From
7 m
To
8 m
Intercept Depth
7 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-017:7-8
Mining Method
underground

Location

Location
L5
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade zinc over a very narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS zinc.
  • Very narrow intercept length.
  • True thickness not available.

Evidence · table

“1220”

Context: EL-26-017

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-017Electrolode · copperGrade: 1.6Grade Unit: %Intercept: 1 mView all details
Link to this fact

Identity

Hole ID
EL-26-017
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.6
Grade Unit
%
Intercept
1 m
From
7 m
To
8 m
Intercept Depth
7 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-017:7-8
Mining Method
underground

Location

Location
L5
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows a strong copper grade, but over a very narrow width, limiting its overall significance, and true thickness is not provided.

Positive factors

  • Strong grade for VMS copper.

Negative factors

  • Very narrow intercept length.
  • True thickness not available.

Evidence · table

“16000”

Context: EL-26-017

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-017Electrolode · goldGrade: 0.12Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
EL-26-017
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.12
Grade Unit
ppm
Intercept
1 m
From
7 m
To
8 m
Intercept Depth
7 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-017:7-8
Mining Method
underground

Location

Location
L5
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Very narrow intercept length.
  • True thickness not available.

Evidence · table

“0.12”

Context: EL-26-017

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-017Electrolode · silverGrade: 19.5Grade Unit: ppmIntercept: 1 mView all details
Link to this fact

Identity

Hole ID
EL-26-017
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
19.5
Grade Unit
ppm
Intercept
1 m
From
7 m
To
8 m
Intercept Depth
7 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-017:7-8
Mining Method
underground

Location

Location
L5
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver over a very narrow width, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Very narrow intercept length.
  • True thickness not available.

Evidence · table

“19.50”

Context: EL-26-017

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-018Electrolode · zincGrade: 1.422Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-018
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.422
Grade Unit
%
Intercept
1.2 m
From
342.2 m
To
343.4 m
Intercept Depth
342.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-018:342.2-343.4
Mining Method
underground

Location

Location
Far East L6070
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade zinc over a narrow width, which is not particularly significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“14220”

Context: EL-26-018

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-018Electrolode · copperGrade: 0.0732Grade Unit: %Intercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-018
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.0732
Grade Unit
%
Intercept
1.2 m
From
342.2 m
To
343.4 m
Intercept Depth
342.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-018:342.2-343.4
Mining Method
underground

Location

Location
Far East L6070
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“732”

Context: EL-26-018

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-018Electrolode · goldGrade: 0.03Grade Unit: ppmIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-018
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.03
Grade Unit
ppm
Intercept
1.2 m
From
342.2 m
To
343.4 m
Intercept Depth
342.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-018:342.2-343.4
Mining Method
underground

Location

Location
Far East L6070
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.03”

Context: EL-26-018

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-018Electrolode · silverGrade: 8.85Grade Unit: ppmIntercept: 1.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-018
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
8.85
Grade Unit
ppm
Intercept
1.2 m
From
342.2 m
To
343.4 m
Intercept Depth
342.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-018:342.2-343.4
Mining Method
underground

Location

Location
Far East L6070
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“8.85”

Context: EL-26-018

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · zincGrade: 0.2085Grade Unit: %Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.2085
Grade Unit
%
Intercept
4.2 m
From
51 m
To
55.2 m
Intercept Depth
51 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:51-55.2
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade zinc over a moderate width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS zinc.
  • True thickness not available.

Evidence · table

“2085”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · copperGrade: 0.031Grade Unit: %Intercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.031
Grade Unit
%
Intercept
4.2 m
From
51 m
To
55.2 m
Intercept Depth
51 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:51-55.2
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a moderate width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • True thickness not available.

Evidence · table

“310”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · goldGrade: 0.04Grade Unit: ppmIntercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.04
Grade Unit
ppm
Intercept
4.2 m
From
51 m
To
55.2 m
Intercept Depth
51 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:51-55.2
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • True thickness not available.

Evidence · table

“0.04”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · silverGrade: 1.8Grade Unit: ppmIntercept: 4.2 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.8
Grade Unit
ppm
Intercept
4.2 m
From
51 m
To
55.2 m
Intercept Depth
51 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:51-55.2
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Very low silver grade.
  • True thickness not available.

Evidence · table

“1.80”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · zincGrade: 0.3298Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.3298
Grade Unit
%
Intercept
1.8 m
From
75.2 m
To
77 m
Intercept Depth
75.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:75.2-77
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade zinc over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“3298”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · copperGrade: 0.0763Grade Unit: %Intercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.0763
Grade Unit
%
Intercept
1.8 m
From
75.2 m
To
77 m
Intercept Depth
75.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:75.2-77
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“763”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · goldGrade: 0.13Grade Unit: ppmIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.13
Grade Unit
ppm
Intercept
1.8 m
From
75.2 m
To
77 m
Intercept Depth
75.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:75.2-77
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.13”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · silverGrade: 4.7Grade Unit: ppmIntercept: 1.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
4.7
Grade Unit
ppm
Intercept
1.8 m
From
75.2 m
To
77 m
Intercept Depth
75.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:75.2-77
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“4.70”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · zincGrade: 0.1755Grade Unit: %Intercept: 6.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.1755
Grade Unit
%
Intercept
6.8 m
From
208 m
To
214.8 m
Intercept Depth
208 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:208-214.8
Mining Method
underground

Location

Location
Far East L2
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade zinc over a good width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS zinc.
  • True thickness not available.

Evidence · table

“1755”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · copperGrade: 0.1167Grade Unit: %Intercept: 6.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.1167
Grade Unit
%
Intercept
6.8 m
From
208 m
To
214.8 m
Intercept Depth
208 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:208-214.8
Mining Method
underground

Location

Location
Far East L2
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a good width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • True thickness not available.

Evidence · table

“1167”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · goldGrade: 0.05Grade Unit: ppmIntercept: 6.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.05
Grade Unit
ppm
Intercept
6.8 m
From
208 m
To
214.8 m
Intercept Depth
208 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:208-214.8
Mining Method
underground

Location

Location
Far East L2
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • True thickness not available.

Evidence · table

“0.05”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-020Electrolode · silverGrade: 3.61Grade Unit: ppmIntercept: 6.8 mView all details
Link to this fact

Identity

Hole ID
EL-26-020
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.61
Grade Unit
ppm
Intercept
6.8 m
From
208 m
To
214.8 m
Intercept Depth
208 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-020:208-214.8
Mining Method
underground

Location

Location
Far East L2
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Very low silver grade.
  • True thickness not available.

Evidence · table

“3.61”

Context: EL-26-020

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-021Electrolode · zincGrade: 0.4299Grade Unit: %Intercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-021
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.4299
Grade Unit
%
Intercept
1.45 m
From
67.95 m
To
69.4 m
Intercept Depth
67.95 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-021:67.95-69.4
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade zinc over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS zinc.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“4299”

Context: EL-26-021

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-021Electrolode · copperGrade: 0.034Grade Unit: %Intercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-021
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.034
Grade Unit
%
Intercept
1.45 m
From
67.95 m
To
69.4 m
Intercept Depth
67.95 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-021:67.95-69.4
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a narrow width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“340”

Context: EL-26-021

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-021Electrolode · goldGrade: 0.05Grade Unit: ppmIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-021
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.05
Grade Unit
ppm
Intercept
1.45 m
From
67.95 m
To
69.4 m
Intercept Depth
67.95 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-021:67.95-69.4
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“0.05”

Context: EL-26-021

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-021Electrolode · silverGrade: 2.96Grade Unit: ppmIntercept: 1.45 mView all details
Link to this fact

Identity

Hole ID
EL-26-021
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
2.96
Grade Unit
ppm
Intercept
1.45 m
From
67.95 m
To
69.4 m
Intercept Depth
67.95 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-021:67.95-69.4
Mining Method
underground

Location

Location
Far East L1
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Very low silver grade.
  • Narrow intercept length.
  • True thickness not available.

Evidence · table

“2.96”

Context: EL-26-021

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-025Electrolode · zincGrade: 0.1844Grade Unit: %Intercept: 5.85 mView all details
Link to this fact

Identity

Hole ID
EL-26-025
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.1844
Grade Unit
%
Intercept
5.85 m
From
196.3 m
To
202.15 m
Intercept Depth
196.3 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-025:196.3-202.15
Mining Method
underground

Location

Location
GL-3 Plate
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade zinc over a good width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS zinc.
  • True thickness not available.

Evidence · table

“1844”

Context: EL-26-025

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-025Electrolode · copperGrade: 0.0174Grade Unit: %Intercept: 5.85 mView all details
Link to this fact

Identity

Hole ID
EL-26-025
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.0174
Grade Unit
%
Intercept
5.85 m
From
196.3 m
To
202.15 m
Intercept Depth
196.3 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-025:196.3-202.15
Mining Method
underground

Location

Location
GL-3 Plate
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade copper over a good width, which is not significant for a VMS deposit, and true thickness is not provided.

Negative factors

  • Very low grade for VMS copper.
  • True thickness not available.

Evidence · table

“174”

Context: EL-26-025

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-025Electrolode · goldGrade: 0.01Grade Unit: ppmIntercept: 5.85 mView all details
Link to this fact

Identity

Hole ID
EL-26-025
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.01
Grade Unit
ppm
Intercept
5.85 m
From
196.3 m
To
202.15 m
Intercept Depth
196.3 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-025:196.3-202.15
Mining Method
underground

Location

Location
GL-3 Plate
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade gold, which is not significant, and true thickness is not provided.

Negative factors

  • Very low gold grade.
  • True thickness not available.

Evidence · table

“0.01”

Context: EL-26-025

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

EL-26-025Electrolode · silverGrade: 1.05Grade Unit: ppmIntercept: 5.85 mView all details
Link to this fact

Identity

Hole ID
EL-26-025
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.05
Grade Unit
ppm
Intercept
5.85 m
From
196.3 m
To
202.15 m
Intercept Depth
196.3 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
EL-26-025:196.3-202.15
Mining Method
underground

Location

Location
GL-3 Plate
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: This intercept shows very low-grade silver, which is not significant, and true thickness is not provided.

Negative factors

  • Very low silver grade.
  • True thickness not available.

Evidence · table

“1.05”

Context: EL-26-025

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode · zincGrade: 4.02Grade Unit: %Intercept: 3.36 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
4.02
Grade Unit
%
Intercept
3.36 m
From
475.03 m
To
478.39 m
Intercept Depth
475.03 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:475.03-478.39
Mining Method
underground

Location

Location
East Zone
CRS
NAD83 / Zone 15
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: Expanded from assay table. 4.02 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 13.5 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.02”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode · copperGrade: 1.25Grade Unit: %Intercept: 3.36 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
1.25
Grade Unit
%
Intercept
3.36 m
From
475.03 m
To
478.39 m
Intercept Depth
475.03 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:475.03-478.39
Mining Method
underground

Location

Location
East Zone
CRS
NAD83 / Zone 15
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: Expanded from assay table. 1.25 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 4.2 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.25”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode · goldGrade: 0.11Grade Unit: ppmIntercept: 3.36 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.11
Grade Unit
ppm
Intercept
3.36 m
From
475.03 m
To
478.39 m
Intercept Depth
475.03 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:475.03-478.39
Mining Method
underground

Location

Location
East Zone
CRS
NAD83 / Zone 15
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: Expanded from assay table: 0.11 ppm gold, reported in a unit the rubric does not cover (g/t).

Negative factors

  • Grade unit ppm does not match the gold rubric unit g/t; not scored.

Evidence · table

“0.11”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

IncludesElectrolode · silverGrade: 15.38Grade Unit: ppmIntercept: 3.36 mView all details
Link to this fact

Identity

Hole ID
Includes
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
15.38
Grade Unit
ppm
Intercept
3.36 m
From
475.03 m
To
478.39 m
Intercept Depth
475.03 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Includes:475.03-478.39
Mining Method
underground

Location

Location
East Zone
CRS
NAD83 / Zone 15
Loc. Source
document

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: Expanded from assay table: 15.38 ppm silver, reported in a unit the rubric does not cover (g/t).

Negative factors

  • Grade unit ppm does not match the silver rubric unit g/t; not scored.

Evidence · table

“15.38”

Context: Includes

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode · zincGrade: 3.62Grade Unit: %Intercept: 1.74 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode
Commodity
zinc
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.62
Grade Unit
%
Intercept
1.74 m
From
474.58 m
To
476.32 m
Intercept Depth
474.58 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:474.58-476.32
Mining Method
underground

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: Expanded from assay table. 3.62 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 6.3 %·m is below (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.62”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode · copperGrade: 3.19Grade Unit: %Intercept: 1.74 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode
Commodity
copper
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
3.19
Grade Unit
%
Intercept
1.74 m
From
474.58 m
To
476.32 m
Intercept Depth
474.58 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:474.58-476.32
Mining Method
underground

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: Expanded from assay table. 3.19 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 5.6 %·m is below (grade alone is exceptional; the better of the two is used).

Positive factors

  • 3.19 % copper is exceptional on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.19”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode · goldGrade: 0.23Grade Unit: ppmIntercept: 1.74 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode
Commodity
gold
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
0.23
Grade Unit
ppm
Intercept
1.74 m
From
474.58 m
To
476.32 m
Intercept Depth
474.58 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:474.58-476.32
Mining Method
underground

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: Expanded from assay table: 0.23 ppm gold, reported in a unit the rubric does not cover (g/t).

Negative factors

  • Grade unit ppm does not match the gold rubric unit g/t; not scored.

Evidence · table

“0.23”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Also Incl.Electrolode · silverGrade: 37.29Grade Unit: ppmIntercept: 1.74 mView all details
Link to this fact

Identity

Hole ID
Also Incl.
Project
Electrolode
Commodity
silver
Region
canada_on
Reported Region
canada_on
Ticker
TT

Geometry

Grade
37.29
Grade Unit
ppm
Intercept
1.74 m
From
474.58 m
To
476.32 m
Intercept Depth
474.58 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
Also Incl.:474.58-476.32
Mining Method
underground

Location

CRS
NAD83 / Zone 15

QA/QC

Laboratory
AGAT Laboratories Ltd.
QA/QC Disclosed
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks

Metal Equivalent

Assumptions Disclosed
No

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-07-13T00:00:00.000Z

Reasoning: Expanded from assay table: 37.29 ppm silver, reported in a unit the rubric does not cover (g/t).

Negative factors

  • Grade unit ppm does not match the silver rubric unit g/t; not scored.

Evidence · table

“37.29”

Context: Also Incl.

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.