VIZSLA COPPER INTERSECTS 49.2 METERS GRADING 4.7% COPPER EQUIVALENT AT ITS PALMER PROJECT IN SOUTHEAST ALASKA
Original announcement by cnw on
- Company
- Vizsla Copper Corp.
- Ticker
- VCU
- Exchange
- Unavailable
- Region
- Southeast Alaska
- Primary commodity
- Copper
- Secondary commodities
- Zinc, Silver, Gold, Lead
- Document categories
- Drill results
- Extracted
- 2026-09-12 00:20:09 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Vizsla Copper has announced high-grade drill results from its Palmer VMS Project in Alaska, featuring a 49.2m intercept at 4.7% CuEq in hole CMR26-199. The results confirm the continuity of the high-grade copper core in South Wall Zone 1 and demonstrate downdip extension.
Reasoning: The drill results report exceptionally high-grade copper and zinc intercepts (up to 9.03% Cu) over significant widths, confirming the high-grade core and extending mineralization downdip in a VMS system.
Positive factors
- exceptional copper grades
- broad high-grade intervals
- confirmed downdip continuity
- VMS deposit style high-grade core
Facts used in scoring: 35
Extracted facts
Stored fact records: 35. Some facts used in scoring do not have a stored record.
Drill Results (35)
CMR26-199Palmer · copperGrade: 3.05Grade Unit: %Intercept: 49.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 3.05
- Grade Unit
- %
- Intercept
- 49.2 m
- From
- 305 m
- To
- 354.2 m
- Intercept Depth
- 305 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- CMR26-199:305-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: 49.2m at 3.05% Cu is a strong intercept for a VMS deposit.
Positive factors
- strong copper grade
Evidence · table
“3.05”
Context: 49.2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · zincGrade: 4.85Grade Unit: %Intercept: 49.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 4.85
- Grade Unit
- %
- Intercept
- 49.2 m
- From
- 305 m
- To
- 354.2 m
- Intercept Depth
- 305 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- CMR26-199:305-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Significant zinc component in a polymetallic VMS intercept.
Positive factors
- strong zinc grade
Evidence · table
“4.85”
Context: 49.2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · silverGrade: 21.88Grade Unit: g/tIntercept: 49.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 21.88
- Grade Unit
- g/t
- Intercept
- 49.2 m
- From
- 305 m
- To
- 354.2 m
- Intercept Depth
- 305 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- CMR26-199:305-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Silver byproduct in a high-grade copper-zinc intercept.
Evidence · table
“21.88”
Context: 49.2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · goldGrade: 0.33Grade Unit: g/tIntercept: 49.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.33
- Grade Unit
- g/t
- Intercept
- 49.2 m
- From
- 305 m
- To
- 354.2 m
- Intercept Depth
- 305 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- CMR26-199:305-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Gold byproduct in a high-grade copper-zinc intercept.
Evidence · table
“0.33”
Context: 49.2
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · copperGrade: 5.46Grade Unit: %Intercept: 27 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 5.46
- Grade Unit
- %
- Intercept
- 27 m
- From
- 327.2 m
- To
- 354.2 m
- Intercept Depth
- 327.2 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- CMR26-199:327.2-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.4
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: High-grade core intersection.
Positive factors
- exceptional copper grade
Evidence · table
“5.46”
Context: 27.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · copperGrade: 9.03Grade Unit: %Intercept: 13.1 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 9.03
- Grade Unit
- %
- Intercept
- 13.1 m
- From
- 331.6 m
- To
- 344.7 m
- Intercept Depth
- 331.6 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- CMR26-199:331.6-344.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 10.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Extremely high-grade core intersection.
Positive factors
- exceptional copper grade
Evidence · table
“9.03”
Context: 13.1
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · copperGrade: 2.14Grade Unit: %Intercept: 40.4 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 2.14
- Grade Unit
- %
- Intercept
- 40.4 m
- From
- 349.3 m
- To
- 389.7 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Program
- exploration
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-389.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Confirms high-grade core downdip.
Positive factors
- confirmed downdip continuity
Evidence · table
“2.14”
Context: 40.4
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · leadGrade: 0.06Grade Unit: %Intercept: 49.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.06
- Grade Unit
- %
- Intercept
- 49.2 m
- From
- 305 m
- To
- 354.2 m
- Intercept Depth
- 305 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-199:305-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.06 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 3.0 %·m is below.
Negative factors
- 0.06 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.06”
Context: CMR26-199
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · zincGrade: 8.55Grade Unit: %Intercept: 27 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 8.55
- Grade Unit
- %
- Intercept
- 27 m
- From
- 327.2 m
- To
- 354.2 m
- Intercept Depth
- 327.2 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-199:327.2-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.4
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 8.55 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 230.9 %·m is strong (grade alone is moderate; the better of the two is used).
Positive factors
- 8.55 % zinc is strong on the default band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“8.55”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · leadGrade: 0.1Grade Unit: %Intercept: 27 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.1
- Grade Unit
- %
- Intercept
- 27 m
- From
- 327.2 m
- To
- 354.2 m
- Intercept Depth
- 327.2 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-199:327.2-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.4
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.7 %·m is below.
Negative factors
- 0.1 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.10”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · silverGrade: 39.12Grade Unit: g/tIntercept: 27 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 39.12
- Grade Unit
- g/t
- Intercept
- 27 m
- From
- 327.2 m
- To
- 354.2 m
- Intercept Depth
- 327.2 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-199:327.2-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.4
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 39.12 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 1056.2 g/t·m is moderate (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“39.12”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · goldGrade: 0.58Grade Unit: g/tIntercept: 27 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.58
- Grade Unit
- g/t
- Intercept
- 27 m
- From
- 327.2 m
- To
- 354.2 m
- Intercept Depth
- 327.2 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-199:327.2-354.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 8.4
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.58 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 15.7 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.58”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · zincGrade: 1.83Grade Unit: %Intercept: 13.1 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 1.83
- Grade Unit
- %
- Intercept
- 13.1 m
- From
- 331.6 m
- To
- 344.7 m
- Intercept Depth
- 331.6 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-199:331.6-344.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 10.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.83 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 24.0 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.83”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · leadGrade: 0.01Grade Unit: %Intercept: 13.1 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 13.1 m
- From
- 331.6 m
- To
- 344.7 m
- Intercept Depth
- 331.6 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-199:331.6-344.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 10.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.
Negative factors
- 0.01 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · silverGrade: 42.74Grade Unit: g/tIntercept: 13.1 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 42.74
- Grade Unit
- g/t
- Intercept
- 13.1 m
- From
- 331.6 m
- To
- 344.7 m
- Intercept Depth
- 331.6 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-199:331.6-344.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 10.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 42.74 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 559.9 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“42.74”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-199Palmer · goldGrade: 0.78Grade Unit: g/tIntercept: 13.1 mView all detailsHide details
Identity
- Hole ID
- CMR26-199
- Project
- Palmer
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.78
- Grade Unit
- g/t
- Intercept
- 13.1 m
- From
- 331.6 m
- To
- 344.7 m
- Intercept Depth
- 331.6 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-199:331.6-344.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 10.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.78 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 10.2 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.78”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · zincGrade: 2.43Grade Unit: %Intercept: 40.4 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 2.43
- Grade Unit
- %
- Intercept
- 40.4 m
- From
- 349.3 m
- To
- 389.7 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-389.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 2.43 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 98.2 %·m is moderate (grade alone is weak; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“2.43”
Context: CMR26-201
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · leadGrade: 0.05Grade Unit: %Intercept: 40.4 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.05
- Grade Unit
- %
- Intercept
- 40.4 m
- From
- 349.3 m
- To
- 389.7 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-389.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.05 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.0 %·m is below.
Negative factors
- 0.05 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.05”
Context: CMR26-201
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · silverGrade: 17.28Grade Unit: g/tIntercept: 40.4 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 17.28
- Grade Unit
- g/t
- Intercept
- 40.4 m
- From
- 349.3 m
- To
- 389.7 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-389.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 17.28 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 698.1 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“17.28”
Context: CMR26-201
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · goldGrade: 0.21Grade Unit: g/tIntercept: 40.4 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 40.4 m
- From
- 349.3 m
- To
- 389.7 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-389.7
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.21 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 8.5 g/t·m is below.
Negative factors
- 0.21 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.21”
Context: CMR26-201
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · copperGrade: 3.14Grade Unit: %Intercept: 25.6 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 3.14
- Grade Unit
- %
- Intercept
- 25.6 m
- From
- 349.3 m
- To
- 374.9 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-374.9
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 3.14 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 80.4 %·m is moderate (grade alone is exceptional; the better of the two is used).
Positive factors
- 3.14 % copper is exceptional on the vms deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“3.14”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · zincGrade: 1.32Grade Unit: %Intercept: 25.6 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 1.32
- Grade Unit
- %
- Intercept
- 25.6 m
- From
- 349.3 m
- To
- 374.9 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-374.9
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.32 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 33.8 %·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.32”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · leadGrade: 0.01Grade Unit: %Intercept: 25.6 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.01
- Grade Unit
- %
- Intercept
- 25.6 m
- From
- 349.3 m
- To
- 374.9 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-374.9
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.
Negative factors
- 0.01 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.01”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · silverGrade: 13.95Grade Unit: g/tIntercept: 25.6 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 13.95
- Grade Unit
- g/t
- Intercept
- 25.6 m
- From
- 349.3 m
- To
- 374.9 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-374.9
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 13.95 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 357.1 g/t·m is weak (grade alone is below; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“13.95”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · goldGrade: 0.21Grade Unit: g/tIntercept: 25.6 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.21
- Grade Unit
- g/t
- Intercept
- 25.6 m
- From
- 349.3 m
- To
- 374.9 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-374.9
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.7
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.21 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 5.4 g/t·m is below.
Negative factors
- 0.21 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.21”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · copperGrade: 4.63Grade Unit: %Intercept: 12.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 4.63
- Grade Unit
- %
- Intercept
- 12.2 m
- From
- 349.3 m
- To
- 361.5 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-361.5
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.9
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 4.63 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 56.5 %·m is weak (grade alone is exceptional; the better of the two is used).
Positive factors
- 4.63 % copper is exceptional on the vms deposit band.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“4.63”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · zincGrade: 0.19Grade Unit: %Intercept: 12.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.19
- Grade Unit
- %
- Intercept
- 12.2 m
- From
- 349.3 m
- To
- 361.5 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-361.5
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.9
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.19 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 2.3 %·m is below.
Negative factors
- 0.19 % zinc is below the weak threshold (2 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.19”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · leadGrade: 0Grade Unit: %Intercept: 12.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0
- Grade Unit
- %
- Intercept
- 12.2 m
- From
- 349.3 m
- To
- 361.5 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-361.5
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.9
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.
Negative factors
- 0 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.00”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · silverGrade: 13.43Grade Unit: g/tIntercept: 12.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 13.43
- Grade Unit
- g/t
- Intercept
- 12.2 m
- From
- 349.3 m
- To
- 361.5 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-361.5
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.9
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 13.43 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 163.8 g/t·m is below.
Negative factors
- 13.43 g/t silver is below the weak threshold (30 g/t) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“13.43”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · goldGrade: 0.22Grade Unit: g/tIntercept: 12.2 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.22
- Grade Unit
- g/t
- Intercept
- 12.2 m
- From
- 349.3 m
- To
- 361.5 m
- Intercept Depth
- 349.3 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:349.3-361.5
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 4.9
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.22 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.7 g/t·m is below.
Negative factors
- 0.22 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.22”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · copperGrade: 1.03Grade Unit: %Intercept: 11.3 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- copper
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 1.03
- Grade Unit
- %
- Intercept
- 11.3 m
- From
- 367.9 m
- To
- 379.2 m
- Intercept Depth
- 367.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:367.9-379.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 1.03 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 11.6 %·m is below (grade alone is moderate; the better of the two is used).
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“1.03”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · zincGrade: 6.66Grade Unit: %Intercept: 11.3 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- zinc
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 6.66
- Grade Unit
- %
- Intercept
- 11.3 m
- From
- 367.9 m
- To
- 379.2 m
- Intercept Depth
- 367.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:367.9-379.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 6.66 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 75.3 %·m is moderate.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“6.66”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · leadGrade: 0.13Grade Unit: %Intercept: 11.3 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- lead
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.13
- Grade Unit
- %
- Intercept
- 11.3 m
- From
- 367.9 m
- To
- 379.2 m
- Intercept Depth
- 367.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:367.9-379.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.13 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.5 %·m is below.
Negative factors
- 0.13 % lead is below the weak threshold (1 %) on the default band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.13”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · silverGrade: 36.45Grade Unit: g/tIntercept: 11.3 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- silver
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 36.45
- Grade Unit
- g/t
- Intercept
- 11.3 m
- From
- 367.9 m
- To
- 379.2 m
- Intercept Depth
- 367.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:367.9-379.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 36.45 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 411.9 g/t·m is weak.
Negative factors
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“36.45”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
CMR26-201Palmer · goldGrade: 0.36Grade Unit: g/tIntercept: 11.3 mView all detailsHide details
Identity
- Hole ID
- CMR26-201
- Project
- Palmer
- Commodity
- gold
- Region
- usa_ak
- Reported Region
- usa_ak
- Ticker
- VCU
Geometry
- Grade
- 0.36
- Grade Unit
- g/t
- Intercept
- 11.3 m
- From
- 367.9 m
- To
- 379.2 m
- Intercept Depth
- 367.9 m
Classification
- Deposit Type
- vms
- Sample Type
- drill
- Group ID
- CMR26-201:367.9-379.2
- Mining Method
- underground
QA/QC
- Laboratory
- ALS
- QA/QC Disclosed
- Yes
- Lab Certified
- Yes
- QP Signed
- Yes
- QA/QC Methods
- standards, blanks, duplicates
Metal Equivalent
- Metal Eq. Grade
- 3.3
- Metal Eq. Unit
- % Cu-Eq
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-09-11T00:00:00.000Z
Reasoning: Expanded from assay table. 0.36 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 4.1 g/t·m is below.
Negative factors
- 0.36 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
- Scored from rubric bands during table expansion, not from document context.
Evidence · table
“0.36”
Context: Including
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Metal Equivalent Opaquenegative
Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.
Why it applies: an equivalent grade is reported without its assumptions
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.