VIZSLA COPPER INTERSECTS 49.2 METERS GRADING 4.7% COPPER EQUIVALENT AT ITS PALMER PROJECT IN SOUTHEAST ALASKA

Original announcement by cnw on

Company
Vizsla Copper Corp.
Ticker
VCU
Exchange
Unavailable
Region
Southeast Alaska
Primary commodity
Copper
Secondary commodities
Zinc, Silver, Gold, Lead
Document categories
Drill results
Extracted
2026-09-12 00:20:09 UTC

Analysis by Minestarters Atlas

Minestarters Atlas analysis

Summary

Vizsla Copper has announced high-grade drill results from its Palmer VMS Project in Alaska, featuring a 49.2m intercept at 4.7% CuEq in hole CMR26-199. The results confirm the continuity of the high-grade copper core in South Wall Zone 1 and demonstrate downdip extension.

Reasoning: The drill results report exceptionally high-grade copper and zinc intercepts (up to 9.03% Cu) over significant widths, confirming the high-grade core and extending mineralization downdip in a VMS system.

Positive factors

  • exceptional copper grades
  • broad high-grade intervals
  • confirmed downdip continuity
  • VMS deposit style high-grade core

Facts used in scoring: 35

Extracted facts

Stored fact records: 35. Some facts used in scoring do not have a stored record.

Drill Results (35)

CMR26-199Palmer · copperGrade: 3.05Grade Unit: %Intercept: 49.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
copper
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
3.05
Grade Unit
%
Intercept
49.2 m
From
305 m
To
354.2 m
Intercept Depth
305 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
CMR26-199:305-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: 49.2m at 3.05% Cu is a strong intercept for a VMS deposit.

Positive factors

  • strong copper grade

Evidence · table

“3.05”

Context: 49.2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · zincGrade: 4.85Grade Unit: %Intercept: 49.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
zinc
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
4.85
Grade Unit
%
Intercept
49.2 m
From
305 m
To
354.2 m
Intercept Depth
305 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
CMR26-199:305-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Significant zinc component in a polymetallic VMS intercept.

Positive factors

  • strong zinc grade

Evidence · table

“4.85”

Context: 49.2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · silverGrade: 21.88Grade Unit: g/tIntercept: 49.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
silver
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
21.88
Grade Unit
g/t
Intercept
49.2 m
From
305 m
To
354.2 m
Intercept Depth
305 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
CMR26-199:305-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Silver byproduct in a high-grade copper-zinc intercept.

Evidence · table

“21.88”

Context: 49.2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · goldGrade: 0.33Grade Unit: g/tIntercept: 49.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
gold
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.33
Grade Unit
g/t
Intercept
49.2 m
From
305 m
To
354.2 m
Intercept Depth
305 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
CMR26-199:305-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Gold byproduct in a high-grade copper-zinc intercept.

Evidence · table

“0.33”

Context: 49.2

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · copperGrade: 5.46Grade Unit: %Intercept: 27 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
copper
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
5.46
Grade Unit
%
Intercept
27 m
From
327.2 m
To
354.2 m
Intercept Depth
327.2 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
CMR26-199:327.2-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: High-grade core intersection.

Positive factors

  • exceptional copper grade

Evidence · table

“5.46”

Context: 27.0

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · copperGrade: 9.03Grade Unit: %Intercept: 13.1 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
copper
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
9.03
Grade Unit
%
Intercept
13.1 m
From
331.6 m
To
344.7 m
Intercept Depth
331.6 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
CMR26-199:331.6-344.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Extremely high-grade core intersection.

Positive factors

  • exceptional copper grade

Evidence · table

“9.03”

Context: 13.1

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · copperGrade: 2.14Grade Unit: %Intercept: 40.4 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
copper
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
2.14
Grade Unit
%
Intercept
40.4 m
From
349.3 m
To
389.7 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Program
exploration
Sample Type
drill
Group ID
CMR26-201:349.3-389.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Confirms high-grade core downdip.

Positive factors

  • confirmed downdip continuity

Evidence · table

“2.14”

Context: 40.4

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · leadGrade: 0.06Grade Unit: %Intercept: 49.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
lead
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.06
Grade Unit
%
Intercept
49.2 m
From
305 m
To
354.2 m
Intercept Depth
305 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-199:305-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.06 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 3.0 %·m is below.

Negative factors

  • 0.06 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.06”

Context: CMR26-199

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · zincGrade: 8.55Grade Unit: %Intercept: 27 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
zinc
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
8.55
Grade Unit
%
Intercept
27 m
From
327.2 m
To
354.2 m
Intercept Depth
327.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-199:327.2-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 8.55 % zinc is strong against the default band [18, 10, 5, 2] %. Grade×width 230.9 %·m is strong (grade alone is moderate; the better of the two is used).

Positive factors

  • 8.55 % zinc is strong on the default band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“8.55”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · leadGrade: 0.1Grade Unit: %Intercept: 27 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
lead
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.1
Grade Unit
%
Intercept
27 m
From
327.2 m
To
354.2 m
Intercept Depth
327.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-199:327.2-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.1 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.7 %·m is below.

Negative factors

  • 0.1 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.10”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · silverGrade: 39.12Grade Unit: g/tIntercept: 27 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
silver
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
39.12
Grade Unit
g/t
Intercept
27 m
From
327.2 m
To
354.2 m
Intercept Depth
327.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-199:327.2-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 39.12 g/t silver is moderate against the default band [500, 200, 100, 30] g/t. Grade×width 1056.2 g/t·m is moderate (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“39.12”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · goldGrade: 0.58Grade Unit: g/tIntercept: 27 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
gold
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.58
Grade Unit
g/t
Intercept
27 m
From
327.2 m
To
354.2 m
Intercept Depth
327.2 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-199:327.2-354.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
8.4
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.58 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 15.7 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.58”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · zincGrade: 1.83Grade Unit: %Intercept: 13.1 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
zinc
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
1.83
Grade Unit
%
Intercept
13.1 m
From
331.6 m
To
344.7 m
Intercept Depth
331.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-199:331.6-344.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 1.83 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 24.0 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.83”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · leadGrade: 0.01Grade Unit: %Intercept: 13.1 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
lead
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.01
Grade Unit
%
Intercept
13.1 m
From
331.6 m
To
344.7 m
Intercept Depth
331.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-199:331.6-344.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.1 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · silverGrade: 42.74Grade Unit: g/tIntercept: 13.1 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
silver
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
42.74
Grade Unit
g/t
Intercept
13.1 m
From
331.6 m
To
344.7 m
Intercept Depth
331.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-199:331.6-344.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 42.74 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 559.9 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“42.74”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-199Palmer · goldGrade: 0.78Grade Unit: g/tIntercept: 13.1 mView all details
Link to this fact

Identity

Hole ID
CMR26-199
Project
Palmer
Commodity
gold
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.78
Grade Unit
g/t
Intercept
13.1 m
From
331.6 m
To
344.7 m
Intercept Depth
331.6 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-199:331.6-344.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
10.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.78 g/t gold is weak against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 10.2 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.78”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · zincGrade: 2.43Grade Unit: %Intercept: 40.4 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
zinc
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
2.43
Grade Unit
%
Intercept
40.4 m
From
349.3 m
To
389.7 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-389.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 2.43 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 98.2 %·m is moderate (grade alone is weak; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“2.43”

Context: CMR26-201

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · leadGrade: 0.05Grade Unit: %Intercept: 40.4 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
lead
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.05
Grade Unit
%
Intercept
40.4 m
From
349.3 m
To
389.7 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-389.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.05 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 2.0 %·m is below.

Negative factors

  • 0.05 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.05”

Context: CMR26-201

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · silverGrade: 17.28Grade Unit: g/tIntercept: 40.4 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
silver
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
17.28
Grade Unit
g/t
Intercept
40.4 m
From
349.3 m
To
389.7 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-389.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 17.28 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 698.1 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“17.28”

Context: CMR26-201

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · goldGrade: 0.21Grade Unit: g/tIntercept: 40.4 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
gold
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.21
Grade Unit
g/t
Intercept
40.4 m
From
349.3 m
To
389.7 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-389.7
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 8.5 g/t·m is below.

Negative factors

  • 0.21 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.21”

Context: CMR26-201

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · copperGrade: 3.14Grade Unit: %Intercept: 25.6 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
copper
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
3.14
Grade Unit
%
Intercept
25.6 m
From
349.3 m
To
374.9 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-374.9
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 3.14 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 80.4 %·m is moderate (grade alone is exceptional; the better of the two is used).

Positive factors

  • 3.14 % copper is exceptional on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“3.14”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · zincGrade: 1.32Grade Unit: %Intercept: 25.6 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
zinc
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
1.32
Grade Unit
%
Intercept
25.6 m
From
349.3 m
To
374.9 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-374.9
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 1.32 % zinc is weak against the default band [18, 10, 5, 2] %. Grade×width 33.8 %·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.32”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · leadGrade: 0.01Grade Unit: %Intercept: 25.6 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
lead
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.01
Grade Unit
%
Intercept
25.6 m
From
349.3 m
To
374.9 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-374.9
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.01 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.3 %·m is below.

Negative factors

  • 0.01 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.01”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · silverGrade: 13.95Grade Unit: g/tIntercept: 25.6 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
silver
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
13.95
Grade Unit
g/t
Intercept
25.6 m
From
349.3 m
To
374.9 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-374.9
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 13.95 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 357.1 g/t·m is weak (grade alone is below; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“13.95”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · goldGrade: 0.21Grade Unit: g/tIntercept: 25.6 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
gold
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.21
Grade Unit
g/t
Intercept
25.6 m
From
349.3 m
To
374.9 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-374.9
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.7
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.21 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 5.4 g/t·m is below.

Negative factors

  • 0.21 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.21”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · copperGrade: 4.63Grade Unit: %Intercept: 12.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
copper
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
4.63
Grade Unit
%
Intercept
12.2 m
From
349.3 m
To
361.5 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-361.5
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.9
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 4.63 % copper is exceptional against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 56.5 %·m is weak (grade alone is exceptional; the better of the two is used).

Positive factors

  • 4.63 % copper is exceptional on the vms deposit band.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“4.63”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · zincGrade: 0.19Grade Unit: %Intercept: 12.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
zinc
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.19
Grade Unit
%
Intercept
12.2 m
From
349.3 m
To
361.5 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-361.5
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.9
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.19 % zinc is below against the default band [18, 10, 5, 2] %. Grade×width 2.3 %·m is below.

Negative factors

  • 0.19 % zinc is below the weak threshold (2 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.19”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · leadGrade: 0Grade Unit: %Intercept: 12.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
lead
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0
Grade Unit
%
Intercept
12.2 m
From
349.3 m
To
361.5 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-361.5
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.9
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 0.0 %·m is below.

Negative factors

  • 0 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.00”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · silverGrade: 13.43Grade Unit: g/tIntercept: 12.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
silver
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
13.43
Grade Unit
g/t
Intercept
12.2 m
From
349.3 m
To
361.5 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-361.5
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.9
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 13.43 g/t silver is below against the default band [500, 200, 100, 30] g/t. Grade×width 163.8 g/t·m is below.

Negative factors

  • 13.43 g/t silver is below the weak threshold (30 g/t) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“13.43”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · goldGrade: 0.22Grade Unit: g/tIntercept: 12.2 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
gold
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.22
Grade Unit
g/t
Intercept
12.2 m
From
349.3 m
To
361.5 m
Intercept Depth
349.3 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:349.3-361.5
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
4.9
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.22 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 2.7 g/t·m is below.

Negative factors

  • 0.22 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.22”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · copperGrade: 1.03Grade Unit: %Intercept: 11.3 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
copper
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
1.03
Grade Unit
%
Intercept
11.3 m
From
367.9 m
To
379.2 m
Intercept Depth
367.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:367.9-379.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 1.03 % copper is moderate against the vms deposit band [2.5, 1.5, 0.8, 0.4] %. Grade×width 11.6 %·m is below (grade alone is moderate; the better of the two is used).

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“1.03”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · zincGrade: 6.66Grade Unit: %Intercept: 11.3 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
zinc
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
6.66
Grade Unit
%
Intercept
11.3 m
From
367.9 m
To
379.2 m
Intercept Depth
367.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:367.9-379.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 6.66 % zinc is moderate against the default band [18, 10, 5, 2] %. Grade×width 75.3 %·m is moderate.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“6.66”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · leadGrade: 0.13Grade Unit: %Intercept: 11.3 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
lead
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.13
Grade Unit
%
Intercept
11.3 m
From
367.9 m
To
379.2 m
Intercept Depth
367.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:367.9-379.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.13 % lead is below against the default band [10, 6, 3, 1] %. Grade×width 1.5 %·m is below.

Negative factors

  • 0.13 % lead is below the weak threshold (1 %) on the default band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.13”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · silverGrade: 36.45Grade Unit: g/tIntercept: 11.3 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
silver
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
36.45
Grade Unit
g/t
Intercept
11.3 m
From
367.9 m
To
379.2 m
Intercept Depth
367.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:367.9-379.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 36.45 g/t silver is weak against the default band [500, 200, 100, 30] g/t. Grade×width 411.9 g/t·m is weak.

Negative factors

  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“36.45”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

CMR26-201Palmer · goldGrade: 0.36Grade Unit: g/tIntercept: 11.3 mView all details
Link to this fact

Identity

Hole ID
CMR26-201
Project
Palmer
Commodity
gold
Region
usa_ak
Reported Region
usa_ak
Ticker
VCU

Geometry

Grade
0.36
Grade Unit
g/t
Intercept
11.3 m
From
367.9 m
To
379.2 m
Intercept Depth
367.9 m

Classification

Deposit Type
vms
Sample Type
drill
Group ID
CMR26-201:367.9-379.2
Mining Method
underground

QA/QC

Laboratory
ALS
QA/QC Disclosed
Yes
Lab Certified
Yes
QP Signed
Yes
QA/QC Methods
standards, blanks, duplicates

Metal Equivalent

Metal Eq. Grade
3.3
Metal Eq. Unit
% Cu-Eq

Review

Needs Review
No
Interp. Status
scored
Historical
No

Dates

Event date
2026-09-11T00:00:00.000Z

Reasoning: Expanded from assay table. 0.36 g/t gold is below against the underground mining band [15, 7, 4, 2.5] g/t. Grade×width 4.1 g/t·m is below.

Negative factors

  • 0.36 g/t gold is below the weak threshold (2.5 g/t) on the underground mining band.
  • Scored from rubric bands during table expansion, not from document context.

Evidence · table

“0.36”

Context: Including

Tags used in scoring

QA/QC Disclosedpositive

Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).

Why it applies: qaqc_disclosed is true

Cut-off Undisclosednegative

High-grade interval reported without stating the cut-off grade used for compositing.

Why it applies: no cutoff_grade was stated

Metal Equivalent Opaquenegative

Metal equivalent grade reported without disclosing the price, recovery, or payability assumptions used. Requires an actual metal equivalent grade; a combined elemental basket such as PGE is not a metal equivalent.

Why it applies: an equivalent grade is reported without its assumptions

How Atlas produces this analysis

Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.