Xali Gold Continues to Demonstrate the Scale and Grade of Gold Mineralization at Pico Machay 
Original announcement by tmx on
- Company
- Xali Gold Corp.
- Ticker
- XGC
- Exchange
- TSX
- Region
- Central Peru
- Primary commodity
- Gold
- Secondary commodities
- None reported
- Document categories
- Drill results
- Extracted
- 2026-09-17 06:34:21 UTC
Analysis by Minestarters Atlas
Minestarters Atlas analysis
Summary
Xali Gold reported new assay results from surface channel, rock chip, and underground sampling at its Pico Machay Gold Project in Peru. The program confirmed high-grade gold mineralization, including 13.76 g/t Au over 4.5m from a surface channel, and extended the known mineralized system with new intercepts from underground workings up to 1,000m from the historical resource area. The results will support an upcoming resource update and future exploration.
Reasoning: Xali Gold reported new assay results from surface and underground sampling at its Pico Machay Gold Project, confirming high-grade gold mineralization and extending the known mineralized system. The results are supported by disclosed QA/QC procedures.
Positive factors
- High-grade gold intercepts
- Expansion of mineralized footprint
- Confirmation of epithermal system
- QA/QC disclosed
Negative factors
- Apparent width only
- Cut-off grade for compositing not disclosed
Facts used in scoring: 71
Classification and evidence
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: The news release states that all scientific and technical information has been reviewed and approved by a P.Geo., and samples were submitted to SGS for analysis, with field duplicate results reviewed.
Evidence · text
“All scientific and technical information in this news release has been reviewed and approved by Joanne Freeze, P.Geo. ... The 197 samples were submitted to SGS in Lima, Peru for gold and silver analysis ... reviewing the variance in field duplicate results”
Step-Out Extensionpositive
Mineralization extended beyond the previously known limit.
Why it applies: The results include anomalous gold from underground workings and surface samples outside the resource area, highlighting potential to expand the known mineralized system.
Evidence · text
“Equally important are the numerous anomalous gold results returned from underground workings and surface samples outside the resource area. While several of these areas are beyond the scope of the upcoming resource update, the results highlight the potential to expand the known mineralized system and provide compelling targets for future exploration.”
Apparent Width Onlynegative
Interval given as downhole width with no true width or drill orientation — apparent width may overstate true thickness.
Why it applies: The reported intercepts are given with 'Dimensions (m)' or 'over X meters' without stating true width or drill orientation.
Evidence · text
“2.92 grams per tonne (“g/t”) gold (“Au”) over 31.5 meters (“m”) from Surface Channel 1 including 13.76 g/t Au over 4.5m”
Extracted facts
Stored fact records: 71. Some facts used in scoring do not have a stored record.
Drill Results (71)
Fact 1Pico Machay · goldGrade: 2.92Grade Unit: g/tIntercept: 31.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.92
- Grade Unit
- g/t
- Intercept
- 31.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: High-grade gold intercept over a significant length from surface channel sampling, confirming vertical continuity within the historical resource area.
Positive factors
- Strong gold grade
- Moderate grade-thickness product
- Significant intercept length
- Confirms vertical continuity
Negative factors
- Apparent width only
- Cut-off grade for compositing not disclosed
Evidence · text
“Surface Channel 1 returned 2.92 g/t Au over 31.5 m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 2Pico Machay · goldGrade: 13.76Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 13.76
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Bonanza-grade gold intercept within a broader zone, indicating high-grade mineralization.
Positive factors
- Exceptional gold grade
- Moderate grade-thickness product
- Confirms vertical continuity
Negative factors
- Apparent width only
- Cut-off grade for compositing not disclosed
Evidence · text
“including 13.76 g/t Au over 4.5m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 3Pico Machay · goldGrade: 1.49Grade Unit: g/tIntercept: 41.1 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.49
- Grade Unit
- g/t
- Intercept
- 41.1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-06-25T00:00:00.000Z
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Previously reported moderate-grade gold intercept over a significant length from underground channel sampling.
Positive factors
- Moderate gold grade
- Moderate grade-thickness product
- Significant intercept length
Negative factors
- Stale data re-release
- Apparent width only
- Cut-off grade for compositing not disclosed
Evidence · text
“As previously reported, UG Channel 3 NS returned 1.49 g/t Au over 41.1m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 4Pico Machay · goldGrade: 3.44Grade Unit: g/tIntercept: 8 mHistorical resultNeeds review: historical_restatementView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 3.44
- Grade Unit
- g/t
- Intercept
- 8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 3 NS
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- Yes
- Review Reason
- historical_restatement
- Interp. Status
- scored
- Historical
- Yes
- Historical Source Date
- 2026-06-25T00:00:00.000Z
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Previously reported strong-grade gold intercept within a broader historical zone.
Positive factors
- Strong gold grade
Negative factors
- Stale data re-release
- Apparent width only
- Cut-off grade for compositing not disclosed
Evidence · text
“including 3.44 g/t Au over 8.0m”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Stale Data Re-releasenegative
Historical results re-announced with no new assays or reinterpretation — low genuine novelty.
Why it applies: the fact restates a prior release
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 5Pico Machay · goldGrade: 1.18Grade Unit: g/tIntercept: 4.3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.18
- Grade Unit
- g/t
- Intercept
- 4.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 8
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate-grade gold intercept from an underground working, extending mineralization 800m northeast of the historical resource area.
Positive factors
- Moderate gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · text
“UG Channel 8, the northeastern most working, is located approximately 800m northeast of the centre of the historical resource area and returned 1.18 g/t Au over 4.3m.”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 6Pico Machay · goldGrade: 2.1Grade Unit: g/tIntercept: 1.35 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.1
- Grade Unit
- g/t
- Intercept
- 1.35 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- UG Channel 9
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong-grade gold intercept from an underground working, indicating mineralization in a new area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · text
“At UG Channel 9, 2.10 g/t Au was returned over 1.35m from vuggy silica.”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 7Pico Machay · goldGrade: 0.276Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.276
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface channel sampling.
Negative factors
- Weak gold grade
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.276”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 8Pico Machay · goldGrade: 0.425Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.425
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface channel sampling.
Negative factors
- Weak gold grade
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.425”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 9Pico Machay · goldGrade: 0.286Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.286
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface channel sampling.
Negative factors
- Weak gold grade
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.286”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 10Pico Machay · goldGrade: 13.76Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 13.76
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Exceptional gold grade from surface channel sampling.
Positive factors
- Exceptional gold grade
- Moderate grade-thickness product
Negative factors
- Apparent width only
Evidence · table
“13.760”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 11Pico Machay · goldGrade: 1.015Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.015
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface channel sampling.
Positive factors
- Moderate gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.015”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 12Pico Machay · goldGrade: 0.303Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.303
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface channel sampling.
Positive factors
- Weak gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.303”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 13Pico Machay · goldGrade: 0.917Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.917
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface channel sampling.
Negative factors
- Weak gold grade
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.917”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 14Pico Machay · goldGrade: 0.965Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.965
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface channel sampling.
Negative factors
- Weak gold grade
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.965”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 15Pico Machay · goldGrade: 1.759Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.759
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface channel sampling.
Positive factors
- Moderate gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.759”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 16Pico Machay · goldGrade: 1.728Grade Unit: g/tIntercept: 4.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.728
- Grade Unit
- g/t
- Intercept
- 4.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- unknown
Location
- Location
- Surface Channel 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface channel sampling.
Positive factors
- Moderate gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.728”
Context: 4.50 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 17Pico Machay · goldGrade: 1.045Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.045
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- in Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface sampling within the resource area.
Positive factors
- Moderate gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.045”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 18Pico Machay · goldGrade: 1.329Grade Unit: g/tIntercept: 2.6 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.329
- Grade Unit
- g/t
- Intercept
- 2.6 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- in Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface sampling within the resource area.
Positive factors
- Moderate gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.329”
Context: 2.60 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 19Pico Machay · goldGrade: 1.204Grade Unit: g/tIntercept: 2.8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.204
- Grade Unit
- g/t
- Intercept
- 2.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- in Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface sampling within the resource area.
Positive factors
- Moderate gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.204”
Context: 2.80 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 20Pico Machay · goldGrade: 0.694Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.694
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- in Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface sampling within the resource area.
Negative factors
- Weak gold grade
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.694”
Context: 3.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 21Pico Machay · goldGrade: 0.865Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.865
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- in Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface sampling within the resource area.
Negative factors
- Weak gold grade
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.865”
Context: 3.00 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 22Pico Machay · goldGrade: 0.693Grade Unit: g/tIntercept: 2.8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.693
- Grade Unit
- g/t
- Intercept
- 2.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- in Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface sampling within the resource area.
Negative factors
- Weak gold grade
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.693”
Context: 2.80 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 23Pico Machay · goldGrade: 2.687Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.687
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- in Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling within the resource area.
Positive factors
- Strong gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“2.687”
Context: 3.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 24Pico Machay · goldGrade: 1.823Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.823
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- in Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface sampling within the resource area.
Positive factors
- Moderate gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.823”
Context: 3.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 25Pico Machay · goldGrade: 1.231Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.231
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- in Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface sampling within the resource area.
Positive factors
- Moderate gold grade
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.231”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 26Pico Machay · goldGrade: 4.472Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 4.472
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- In Resource
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling within the resource area.
Positive factors
- Strong gold grade
- Weak grade-thickness product
Negative factors
- Apparent width only
Evidence · table
“4.472”
Context: 3.00 X 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 27Pico Machay · goldGrade: 2.538Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.538
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 5
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling in an exploration target area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“2.538”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 28Pico Machay · goldGrade: 3.787Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 3.787
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 5
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling in an exploration target area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“3.787”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 29Pico Machay · goldGrade: 2.849Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.849
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 5
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling in an exploration target area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“2.849”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 30Pico Machay · goldGrade: 0.53Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.53
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 5
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface sampling in an exploration target area.
Positive factors
- Weak gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.530”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 31Pico Machay · goldGrade: 0.789Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.789
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 5
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from surface sampling in an exploration target area.
Positive factors
- Weak gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.789”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 32Pico Machay · goldGrade: 2.452Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.452
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 6
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling in an exploration target area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“2.452”
Context: 3.00 X 0.34
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 33Pico Machay · goldGrade: 4.208Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 4.208
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 6
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling in an exploration target area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“4.208”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 34Pico Machay · goldGrade: 2.57Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.57
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 6
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling in an exploration target area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“2.570”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 35Pico Machay · goldGrade: 2.135Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.135
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 6
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling in an exploration target area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“2.135”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 36Pico Machay · goldGrade: 1.248Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.248
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface sampling in an exploration target area.
Positive factors
- Moderate gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.248”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 37Pico Machay · goldGrade: 1.256Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.256
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface sampling in an exploration target area.
Positive factors
- Moderate gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.256”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 38Pico Machay · goldGrade: 1.256Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.256
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface sampling in an exploration target area.
Positive factors
- Moderate gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.256”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 39Pico Machay · goldGrade: 5.781Grade Unit: g/tIntercept: 2 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 5.781
- Grade Unit
- g/t
- Intercept
- 2 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Exceptional gold grade from surface sampling in an exploration target area.
Positive factors
- Exceptional gold grade
- Weak grade-thickness product
- Step-out extension
Negative factors
- Apparent width only
Evidence · table
“5.781”
Context: 2.00 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 40Pico Machay · goldGrade: 1.001Grade Unit: g/tIntercept: 3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.001
- Grade Unit
- g/t
- Intercept
- 3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 1
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from surface sampling in an exploration target area.
Positive factors
- Moderate gold grade
- Step-out extension
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.001”
Context: 3.00 X 0.39
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 41Pico Machay · goldGrade: 2.607Grade Unit: g/tIntercept: 1.1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.607
- Grade Unit
- g/t
- Intercept
- 1.1 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 3
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling in an exploration target area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“2.607”
Context: 1.10 x 0.10
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 42Pico Machay · goldGrade: 3.349Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 3.349
- Grade Unit
- g/t
- Intercept
- 1 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- surface
- Mining Method
- unknown
Location
- Location
- Exploration Target 9
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Strong gold grade from surface sampling in an exploration target area.
Positive factors
- Strong gold grade
- Step-out extension
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“3.349”
Context: 1.0
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 43Pico Machay · goldGrade: 3.225Grade Unit: g/tIntercept: 1 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 3.225
- Grade Unit
- g/t
- Intercept
- 1 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Resource UG 5
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling within the resource area.
Positive factors
- Weak gold grade (underground)
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“3.225”
Context: 1.00 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 44Pico Machay · goldGrade: 2.748Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.748
- Grade Unit
- g/t
- Intercept
- 5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Exploration Target 5 UG 6
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling in an exploration target area.
Positive factors
- Weak gold grade (underground)
- Weak grade-thickness product
- Step-out extension
Negative factors
- Apparent width only
Evidence · table
“2.748”
Context: 5.00 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 45Pico Machay · goldGrade: 0.888Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.888
- Grade Unit
- g/t
- Intercept
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- SE UG 7
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“0.888”
Context: 0.90 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 46Pico Machay · goldGrade: 0.292Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.292
- Grade Unit
- g/t
- Intercept
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- SE UG 7
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“0.292”
Context: 0.70 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 47Pico Machay · goldGrade: 2.992Grade Unit: g/tIntercept: 0.55 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.992
- Grade Unit
- g/t
- Intercept
- 0.55 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 650m from Resource Centre UG 8
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Weak gold grade (underground)
- Step-out extension
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“2.992”
Context: 0.55 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 48Pico Machay · goldGrade: 0.852Grade Unit: g/tIntercept: 3.05 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.852
- Grade Unit
- g/t
- Intercept
- 3.05 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 650m from Resource Centre UG 8
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.852”
Context: 3.05 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 49Pico Machay · goldGrade: 0.614Grade Unit: g/tView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.614
- Grade Unit
- g/t
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 650m from Resource Centre UG 8
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area, with unspecified intercept length.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Intercept length not stated
- Apparent width only
Evidence · table
“0.614”
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 50Pico Machay · goldGrade: 0.974Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.974
- Grade Unit
- g/t
- Intercept
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 650m from Resource Centre UG 8
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“0.974”
Context: 0.70 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 51Pico Machay · goldGrade: 1.02Grade Unit: g/tIntercept: 0.7 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.02
- Grade Unit
- g/t
- Intercept
- 0.7 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 650m from Resource Centre UG 8
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“1.020”
Context: 0.70 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 52Pico Machay · goldGrade: 1.102Grade Unit: g/tIntercept: 1.15 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.102
- Grade Unit
- g/t
- Intercept
- 1.15 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 650m from Resource Centre UG 8
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“1.102”
Context: 1.15 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 53Pico Machay · goldGrade: 1.078Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.078
- Grade Unit
- g/t
- Intercept
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 650m from Resource Centre UG 8
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“1.078”
Context: 0.90 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 54Pico Machay · goldGrade: 2.57Grade Unit: g/tIntercept: 0.45 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.57
- Grade Unit
- g/t
- Intercept
- 0.45 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 1,000m from Resource Centre UG 9
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Weak gold grade (underground)
- Step-out extension
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“2.570”
Context: 0.45 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 55Pico Machay · goldGrade: 1.409Grade Unit: g/tIntercept: 0.4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.409
- Grade Unit
- g/t
- Intercept
- 0.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 1,000m from Resource Centre UG 9
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“1.409”
Context: 0.40 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 56Pico Machay · goldGrade: 2.229Grade Unit: g/tIntercept: 0.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 2.229
- Grade Unit
- g/t
- Intercept
- 0.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- NE 1,000m from Resource Centre UG 9
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Weak gold grade (underground)
- Step-out extension
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“2.229”
Context: 0.50 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 57Pico Machay · goldGrade: 4.138Grade Unit: g/tIntercept: 0.6 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 4.138
- Grade Unit
- g/t
- Intercept
- 0.6 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- SW ~500m from Resource Centre UG 10
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Weak gold grade (underground)
- Step-out extension
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“4.138”
Context: 0.60 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 58Pico Machay · goldGrade: 0.681Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.681
- Grade Unit
- g/t
- Intercept
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- SW ~500m from Resource Centre UG 10
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“0.681”
Context: 1.30 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 59Pico Machay · goldGrade: 0.847Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.847
- Grade Unit
- g/t
- Intercept
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- SW ~500m from Resource Centre UG 10
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in a step-out area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“0.847”
Context: 1.30 x 0.30
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 60Pico Machay · goldGrade: 0.23Grade Unit: g/tIntercept: 3.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.23
- Grade Unit
- g/t
- Intercept
- 3.5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Resource UG 12
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling within the resource area.
Negative factors
- Below weak gold grade (underground)
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.230”
Context: 3.50 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 61Pico Machay · goldGrade: 0.357Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.357
- Grade Unit
- g/t
- Intercept
- 3.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Resource UG 12
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling within the resource area.
Positive factors
- Weak gold grade (underground)
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.357”
Context: 3.80 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 62Pico Machay · goldGrade: 0.386Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.386
- Grade Unit
- g/t
- Intercept
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Resource UG 12
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling within the resource area.
Positive factors
- Weak gold grade (underground)
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“0.386”
Context: 0.90 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 63Pico Machay · goldGrade: 0.855Grade Unit: g/tIntercept: 3.8 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.855
- Grade Unit
- g/t
- Intercept
- 3.8 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Resource UG 12
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling within the resource area.
Negative factors
- Below weak gold grade (underground)
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.855”
Context: 3.80 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 64Pico Machay · goldGrade: 0.48Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.48
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Resource UG 12
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling within the resource area.
Positive factors
- Weak gold grade (underground)
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.480”
Context: 4.00 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 65Pico Machay · goldGrade: 0.82Grade Unit: g/tIntercept: 4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.82
- Grade Unit
- g/t
- Intercept
- 4 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Resource UG 12
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling within the resource area.
Negative factors
- Below weak gold grade (underground)
- Low grade-thickness product
- Apparent width only
Evidence · table
“0.820”
Context: 4.00 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 66Pico Machay · goldGrade: 1.031Grade Unit: g/tIntercept: 5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.031
- Grade Unit
- g/t
- Intercept
- 5 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Resource UG 12
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from underground channel sampling within the resource area.
Positive factors
- Moderate gold grade (underground)
Negative factors
- Low grade-thickness product
- Apparent width only
Evidence · table
“1.031”
Context: 5.00 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 67Pico Machay · goldGrade: 0.386Grade Unit: g/tIntercept: 1.3 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.386
- Grade Unit
- g/t
- Intercept
- 1.3 m
Classification
- Deposit Type
- epithermal
- Program
- mixed
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Resource UG 12
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Weak gold grade from underground channel sampling within the resource area.
Positive factors
- Weak gold grade (underground)
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“0.386”
Context: 1.30 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Infill Drillingneutral
Confirmatory drilling to raise resource confidence, not new discovery.
Why it applies: drill_program_type is "mixed"
Fact 68Pico Machay · goldGrade: 1.953Grade Unit: g/tIntercept: 0.9 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.953
- Grade Unit
- g/t
- Intercept
- 0.9 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Exploration Target 6 UG 13
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from underground channel sampling in an exploration target area.
Positive factors
- Moderate gold grade (underground)
- Step-out extension
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“1.953”
Context: 0.90 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 69Pico Machay · goldGrade: 0.284Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.284
- Grade Unit
- g/t
- Intercept
- 1.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Exploration Target 6 UG 13
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in an exploration target area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“0.284”
Context: 1.50 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 70Pico Machay · goldGrade: 1.045Grade Unit: g/tIntercept: 1.4 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 1.045
- Grade Unit
- g/t
- Intercept
- 1.4 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Exploration Target 6 UG 13
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Moderate gold grade from underground channel sampling in an exploration target area.
Positive factors
- Moderate gold grade (underground)
- Step-out extension
Negative factors
- Very low grade-thickness product
- Apparent width only
Evidence · table
“1.045”
Context: 1.40 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
Fact 71Pico Machay · goldGrade: 0.669Grade Unit: g/tIntercept: 1.5 mView all detailsHide details
Identity
- Project
- Pico Machay
- Commodity
- gold
- Region
- peru
- Reported Region
- peru
- Ticker
- XGC
Geometry
- Grade
- 0.669
- Grade Unit
- g/t
- Intercept
- 1.5 m
Classification
- Deposit Type
- epithermal
- Program
- exploration
- Sample Type
- channel
- Mining Method
- underground
Location
- Location
- Exploration Target 6 UG 13
- Loc. Source
- document
QA/QC
- Laboratory
- SGS
- QA/QC Disclosed
- Yes
- QP Signed
- Yes
Review
- Needs Review
- No
- Interp. Status
- scored
- Historical
- No
Dates
- Event date
- 2026-07-28T00:00:00.000Z
Reasoning: Below weak gold grade from underground channel sampling in an exploration target area.
Positive factors
- Step-out extension
Negative factors
- Below weak gold grade (underground)
- Very low grade-thickness product
- Apparent width only
Evidence · table
“0.669”
Context: 1.50 x 0.20
Tags used in scoring
QA/QC Disclosedpositive
Release includes QA/QC disclosure — certified lab, QP sign-off, or stated methods (blanks, standards, duplicates).
Why it applies: qaqc_disclosed is true
Cut-off Undisclosednegative
High-grade interval reported without stating the cut-off grade used for compositing.
Why it applies: no cutoff_grade was stated
How Atlas produces this analysis
Minestarters Atlas uses automated extraction to summarize mining announcements, identify reported measurements, and classify supporting evidence. Sentiment reflects the extracted narrative and classification rules; it is an interpretation, not a reported measurement. Evidence quotes and context are provided where available. Missing data, low-confidence results, and review flags indicate limitations. Check the original publisher announcement before relying on an interpretation.